CF2SCSI Disk Bridge User Guide

Similar documents
PCard2SCSI Flash-Tape User Guide

Intelligent Devices IDI 1100 Series Technical Manual

Product Specification for CANbus to DeviceNet Transducer Gateway

UPDATING THE FIRMWARE IN FRAME BASED MODULES...

Getting Started with your D3000M Series Module

Serial Interface Module

SVMi-8E/SVMi-16E Installation

GW1000 User s Guide. Revision 1.04 Mar 30, 2008

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

OptiStep Hardware Manual

NL6000 Wireless Modem NL6000 User Manual Rev 1.1

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

DIGITAL TRANSDUCER TESTER & PC-INTERFACE (AVA-03) 16-APR-2015 PAGE 1 OF 9 1. GENERAL

Intelligent Devices IDI 6005 Speed Sign Controller Technical Manual

ESPSX3 Ethernet Serial Port Server X 3 Users Guide

DL4000. User s Guide

Select a Data Communication Interface

Technical Description

Quick Start Installation Guide

AirCare General Purpose ModBus Interface ACM1001. OptiDrive Modbus Module Product Specification. For assistance call

BV4531U. I2C or Serial 6 Way Relay

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

CLCD1 Serial 1 wire RS232 LCD development board

HandsOn Technology -- HT-MC-02 MODEL: HT-MC-02

EQ-DCM User Manual Revision 1.02 Sep 10, 2013

DPS INC ASCII MUX. Operation Guide. Table Of Contents. Overview. T/kda

USER MANUAL FOR GS100/GS1003G

V40 Single Board Computer with A-to-D Converter SBC2040

iup-200aliup-201a UNIVERSAL PROM PROGRAMMERS

RTU560 Remote Terminal Unit Connections and Settings

Mega128-DEVelopment Board Progressive Resources LLC 4105 Vincennes Road Indianapolis, IN (317) (317) FAX

GP1 LCD RS232 Terminal Kit 2003 by AWC

P/N Operation & Installation Manual Serial Control Transfer Switch Model TM-STS

Multi-IQ. Firmware: RS232-Data Manager for UPS 4 x RS232 / 1 x LAN-Contacts flash upgradeable. User manual. (Serial Number / Seriennummer)

Setting Up Your Cisco Unified Videoconferencing 3515 MCU

ASCII Read Driver Programmable Serial Interface Card Series 1

Quick Start Installation Guide

Industrial Serial Device Server

DEBUGGING SERIAL COMMUNICATIONS WITH OTHER DEVICES

WiFi to RS-232 adapter user manual

RS-232 to RS-422/485 Converter with 3KV Isolation Protection

TOA IC-100 Institutional Intercom. Remote Control and Monitoring Programmer's Guide

Peter Norberg Consulting, Inc. Professional Solutions to Professional Problems P.O. Box Ferguson, MO (314)

Canlan INSTALLATION MANUAL

rdczbk User Manual ZigBee to RS-232 / RS-485 Converter

Model UD2A-EDID DVI Extender with EDID Management, Serial & GUI Control

DL2000. User s Guide

ThunderBolt Display. by Adam Maurer, VK4GHZ

AF Upgrade Instructions

Document Name: User Manual for SC10MK, Modbus RTU to Modbus TCP Converter

CANopen IO X4 Fact sheet

ICN Mini Link/External. User s Guide. 1733N Model A Mini Link/EXT (Version 1) 1732N Model A ICN Interface Board (Version 1)

MS Protocol Converter. User Manual. Firmware version 2.0 ISI. Instrumental Solutions, Inc.

Getting started with your DGH module:

icharger Synchronous Balance Charger/Discharger Contents

melabs Serial LCD Firmware Version 1.0 2/7/07

CPM Series. Control Port Manager. User's Guide. Models CPM-1600 and CPM-800

+ (5~27 VDC) GND. Bluetooth V4.1 BLE RS-232 Serial Adapter. Model: BLE-232B. 1. Package content: BLE RS-232 adapter

2001 by NEC America. All Rights Reserved. Printed in U.S.A.

Product Brief M68340EVS EVALUATION SYSTEM

CAMit I Camera with built in Modem

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

Intelligent Time Code Distribution Amplifier IBU-160i. Operation and Maintenance Manual P/N: REV A

melabs Serial LCD Firmware Version 1.1 3/5/07

CMS-8GP32. A Motorola MC68HC908GP32 Microcontroller Board. xiom anufacturing

Serial Communication Converters & Adapters Instruction Manual

I/O Interface DNA300

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM-1.0 Version /8/2011 USER MANUAL

LCD Module with I2C / Serial Interface and Keypad Control «LCD I2C/Serial» User s Guide. Copyright 2008 IMS

DataBridge Serial Multiplexer (SDR-MUX) User's Manual

3.1 I-7560 Pin Assignment and Specifications: Introduction

HART / EtherNet/IP Gateway GT200-HT-EI User Manual V 1.0 REV A SST Automation

MPA FLASH PROGRAMMING

CHAPTER 2 SETUP AND INSTALLATION

A3-TFFCBL-02 USB-to-UART Adapter User Manual

ALE/PROG# is pulsed low during programming,

Features: Analog to Digital: 12 bit resolution TTL outputs, RS-232 tolerant inputs 4.096V reference (1mV/count) 115K max speed

um-fpu Application Note 9 Adding a Serial Connection to um-fpu V2

PFCS/Qualifier Interface

Installation and Programming Manual

QUASAR PROJECT KIT # ATMEL AVR PROGRAMMER

SERVICE INSTRUCTION. Updating the firmware and software on the RCS-2

Lumio Release Note Lumio Multi-Touch Communication Protocol

Industrial 1-port RS422/485 Modbus Gateway IMG-110T

Model DVS-2A 2-Port DVI Switch with Audio, Serial Control & Long Cable Equalization

Validator Update Instructions for Rowe BC1200 $1 - $20

OEM-MICODE (MIFARE ICODE)

TinyTrak4 v7 Hardware Manual

Eagle PT-MP1 Pan Tilt Communications Multiplexer Installation and Operations Manual Revision 3.0 August 20, 2001

User Manual Revision: A04 June 23, QuEST Rail LLC.

SB72EX User's Manual

RS-232 Driver Module

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

Soekris Engineering. net4501 series boards and systems. User s Manual

What s in the box. Connection Please see also a video tutorial at Securing wire. 4 pin adapter.

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 3.30 and greater

LIN bus board datasheet EB

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem

Transcription:

CF2SCSI Disk Bridge User Guide

Overview The CF2SCSI bridge PCB is a general purpose SCSI bridge PCB for a Compact Flash (CF) Card. A regular CF card is plugged into the 3M CF socket at the end of the PCB and this is presented as a regular SCSI disk to a SCSI Host via the standard SCSI interface the other end of the board. The PCB mounts in a standard 3.5 form factor tray. It requires 5V only which is supplied via a standard disk power connector When connected to a SCSI Host, the Host sees the PCB as a regular SCSI disk CF2SCSI bridge CF Card HOST SCSI INTERFACE The SCSI bridge PCB carries its microcode in Flash, that can be simply updated via the SCSI or Serial ports. It has an optional standard display module interface to drive a 2 line by16 character backlit, LCD display. Features 3.5 inch form factor Standard 50 pin SCSI1/2 interface 10 Mbytes/sec SCSI burst rate Internal active SCSI termination, disabled/enabled by jumper Optional HVD SCSI interface Compatible with most CF cards Various emulations available.- SCSI2/SCSI1 or SASI Can emulate a standard SCSI tape drive DAT/DLT or 3490 etc consult the factory

Power connector only 5V required Quick install SET SCSI ID J6 positions 1,3,5 Ensure CF card is inserted and home Heartbeat LED SCSI connector NOTE pin 1 Serial port Display connector Disk coming ready LED (green) Disk Activity LED (red) Disable termination LK2 jumper installed = termination enabled Export Termination power jumper LK1 Termination Power present LED1

Set the SCSI ID as required at J6 Serial port enable Unused positions J6 position 1 SCSI ID = 0 no jumpers SCSI ID = 1 jumper position 1 SCSI ID = 2 jumper position 2 SCSI ID = 3 jumper position 1 & 2 SCSI ID = 4 jumper position 3 SCSI ID = 5 jumper position 1 & 3 SCSI ID = 6 jumper position 2 &3 SCSI ID = 7 jumper position 1,2 &3 CF SOCKET Display connector pin 1 J4 Serial Connector Tx,Gnd, Rx Set Termination Disable/Enable at LK2 -- If jumpered termination is ENABLED Do you need to export termination power? -- This is generally not necessary If so jumper LK1. Note that the internal terminators always have power. Connect the SCSI cable Note that pin 1 of the cable is at the edge of the PCB. Connect the 5V power. Note that a standard 5V/12V disk power lead can be used here as the 12V pin is a no-connect on the board. Note the green heartbeat LED will flash. Also note that the 5mm front panel green LED will briefly flash while the CF card is being initialised.

Installation: Use M3x6mm screws ( and no longer) to install the tray INTERNAL DIAGNOSTICS The Diagnostic Feature is accessed via the RS232 port of the CF2SCSI Board. This feature is most useful to gain insight into unexpected operating system exceptions. This section of the manual assumes that problems with SCSI ID, SCSI Termination and other hardware issues have been solved, but system problems which have to do with software, timing or protocol are present. Connect a TTL compatible RS232 terminal or a PC running a terminal emulation to the 9-pin bulkhead connector on the enclosure or direct to the 3-pin header at location JP4 on the board. Set the terminal at 19200 baud, 8 bits and no parity. The cable contacts are as follows: Signal name J4 RS232 9-Pin Connector RS232 25-Pin Connector Receive in 1 3 2 Ground 2 5 7 Transmit out 3 2 3 After the problem has occurred, key in (Control Z) on the terminal to enter the diagnostic mode. The Diagnostic Menu will appear on the terminal screen. The Diagnostics are designed to run as a background task to the foreground operation of the SCSI handling routines. This means that the user may dial into the diagnostic menu options at any time without any significant degradation of SCSI performance in order to activate the real-time SCSI trace. The diagnostic command list shown below is by no means complete. Other commands: Display, Modify and Fill memory; Execute from Specified Address and Download Intel Hex code are for use by factory personnel only. These additional specialised commands listed may prove useful to isolate problems where the Real Time Trace fails to provide an answer. Diagnostic Command Function A C F H Z Activate SCSI Real Time Trace Display Firmware Revision and Checksum Firmware Upload from Serial Port using Intel HEX Format Display this Diagnostic Menu Execute a Power-on Reset

The command prompt is PV> Menu Choice A: Activate SCSI Real Time Trace This option requires special firmware The SCSI Real Time Trace consists of three modes of operation: (a) Print mode = nothing (power-on default) (b) Print mode = only errors (c) Print mode = all These options may be cycled and advanced to the next mode by the keying of the A character. PV> A Real time trace, print mode = nothing This effectively disables the logging and display capability of the Real Time Trace. PV> A Real time trace, print mode = only errors This mode displays both the command which caused the drive to generate a check condition status and the corresponding Request Sense command with bytes 2, 12 and 13 extracted from the sense data returned. PV> CDB=00 00 00 00 00 00, STS=02. CDB=03 00 00 00 FF 00, SENSE=06, ASC=2900. CDB=00 00 00 00 00 00, STS=02. CDB=03 00 00 00 FF 00, SENSE=02, ASC=0401. PV> A Real time trace, print mode = all This mode displays all logged commands with their associated data phases. PV> CDB=00 00 00 00 00 00, STS=02. CDB=03 00 00 00 FF 00, SENSE=02, ASC=0401. CDB=12 00 00 00 FF 00. CDB=1A 00 00 00 FF 00 MODE DATA=10 85 10 08 8C 45 F8 40 00 00 00 00 0E 00 80 80 07. CDB=15 00 00 00 0C 00 MODE DATA=00 00 10 08 8C 00 00 00 00 00 00 00. NB: Logging the data for diagnostic purposes - In order to redirect the displayed information from the standard output device, ie VDU, the user may copy the output to a log file on a local disk by keying Alt-F1.

Menu Choice C: Display Firmware Revision and Checksum Entering a C at the command prompt will display the revision level and checksum of the electronics firmware. PV> Checksum=66A8, code revision = B01f Menu Choice D: Download Intel HEX Code from EPROM to Serial Port This option is available for use by factory personnel only. Menu Choice F: Firmware Upload from Serial Port using Intel HEX Format The CF2SCSI card has a Flash PROM installed. In order to update the code on this PROM, the card needs to be connected to the serial port on a PC and the code downloaded, as follows. 1 Run Procomm or a Terminal Emulator of your choice. 2 Set Baud rate to 19.2 K, no parity, 8 data bits, one stop bit. 3 Switch on CF2SCSI card. Reset message will appear together with Enter a CONTROL-Z to invoke the Diagnostic Mode! 4 Get the Diagnostic Utility, and select F - Firmware upload from serial port using INTEL HEX format. PV> F Firmware upload using Intel HEX transfer. Backing up FLASH in case serial transfer fails! To stop the transfer press ESCAPE if using PROCOMM then press ^C to restore FLASH and reset PG card. Relocating Code... Validating Code... 5 Message appears Start your ASCII upload of the HEX file now : HEX ADDR = 0000 6 Initiate upload - selecting ASCII transfer (filename ******.HEX).

7 When complete ADDR = FFFF, then Checksum test is carried out. If Checksum test passes, board is reset. If Checksum test fails, backup of code is restored at the end of the PROM and the old code is restored for use (if one line fails during upload, then need to exit transfer and old code will be restored). Flash Programming Done Checksum test PASSED. RESET! *** Enter a "CONTROL-Z" to invoke the Diagnostic Mode! *** +++AT E0 B1 X1 M1 L2 &C0 &D0 S0=1 S7=60 S11=55 O Menu Choice G: Go (Execute) from Specified Address This option is available for use by factory personnel only. Menu Choice H: Display this Diagnostic Menu Typing an h or H will cause the diagnostic menu to be re-displayed. Menu Choice M: Display/Modify/Fill/Tabulate Memory This option is available for use by factory personnel only. Menu Choice Q: Quit Diagnostics Hang up modem phone. Menu Choice Z: Execute a Power-on Reset Exits the diagnostic mode by executing a power on reset.

FIRMWARE UPGRADES FOR CF2SCSI UNITS Firmware can be upgraded via the serial port, or by replacing the flash/eprom memory. New code can be sent via e-mail. Connect to J4 to the computer's serial port with a standard serial (extension) cable. If you have some other configuration without the DB9 connector a three wire cable assembly can be configured as follows: DB25 female or DB9 female to J4 2 3 1 (rx in) 7 5 2 (gnd) 3 2 3 (tx out) Start a communications program such as Procomm with the parameters 19200,N,8,1 (19200 baud is the factory (default) standard as shipped, if you have changed it with the Setup menu, please use that value - we suggest 19200). The terminal communications for the CF2SCSI product REQUIRES xon/xoff control. Please refer to the hints below for configuration. Power up the CF2SCSI board. Make a note of the firmware level displayed on the bottom line of the LCD display. This will be used to confirm the firmware upgrade. The communication program should show a menu of items. Select F for firmware upgrade. Start the ASCII file upload (for ProComm type page-up, select ASCII format, and specify the file.hex to transfer). When the transfer is done the screen will show the outcome of the transfer and then reset the unit. Observe the Revision level of the firmware now displayed on the LCD display to verify the new firmware is running. PROBLEMS: If installing an EPROM observe the white outline on the PCB for orientation. HINTS: ProComm should be set up as follows Terminal Setup/Flow Control=xon/xoff Ascii Transfer/Character pacing=0, line pacing=0