CI/SfB (35) Xy April Between us, ideas become reality AXIOM C CANOPY. Installation Guide

Similar documents
Fixed Blade External Louvre

Incorporating V2.2. Product spec >>> > Series CD - Ceiling diffusers

SOUNDSCAPES BLADES COLOR SELECTION

High-tech LED lighting system for interior architecture

Two Circuit Track Power System IS24 / IS26 / IS28

Technical Information DAMPA TILES Decorative Marine Ceiling System

PRELIMINARY. CR Series. Ceiling Rack Systems with AmbiTILT Equipment Loading

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176

Acoustic baffle system

Reduces installation time Locks tray into position - no hardware required

GOLDENI. Owners Manual & Safety Instructions. English. model# GOLDi600. Copyright 2017 Smart Grow Technologies, INC All Rights Reserved

Regolo Perimeter System Reveal the Texture

55mm Grid Systems CLEANROOM PRODUCTS DIVISION

NT-2300 Series Dual Circuit Track System & Accessories

UFR Cleanroom Ceiling Systems

New products spring 2018

IBIS. Duct diffuser with discs for supply air QUICK FACTS

LED Edge-Lit Flat Panels CCT Adjustable

LED Edge-Lit Flat Panels CCT Adjustable

Crease. pat e n t p e n d i n g 2

WIRE AND CABLE MANAGEMENT

EVOTEK ADVANCED CEILING TECHNOLOGY

PHL-H10.QXD :06 Pagina Waterproof and cleanroom luminaires

FLEXBOX. Installation Guide

IBISTM. Duct diffuser with discs for supply air

Suspension System CS-3000

oberonwireless.com Secure Infrastructure Solutions For Wireless Networks Product Catalog 2012

Aluminium Profile / Profilkönig

Dimensions in mm in mm in. R in mm in mm mm. Weight. Dimensions in.

w w w. r i n o x. i n

Durable Metal IP66 Housing

Quartz. Digital. Dual switch. Installation guide. Quartz Digital Dual switch installation instructions Page 1

POP SQUARE 22 LED RECESSED

LED CEILING & WALL LIGHTING

High-tech LED lighting system for interior architecture

2019 Data Center Solutions

CATALOGUE OF MATERIALS, TOOLS & ACCESSORIES METRIC (SI)

Display Products Catalogue. Rapid Delivery of Point of Sale Components

Nominal. Mounting. Length foot foot RUN Nominal Lengths* Suspension Bracket 1 Studs (Factory installed) Rotating Crossbar

AV mounting systems Q4-2009

Vertiv DCM Colocation Rack. Secure, Separate Server Hosting and Housing in Data Centers

Detailed Product Specifications

Service poles for industrial applications

AUREOL RECESSED BEAMSHAPER OPERATION MANUAL

CI/SfB 62 (x) Publication No Quick Fit Floor Service Outlet Boxes & Grommets

POP CORE ROUND 36 LED

WIRED REMOTE INSTALLATION GUIDE

Wireless Enclosures from Wiremold/Legrand

High-tech LED lighting system for interior architecture

Product Guide. Server Safes & Cabinets Modular Caging Security Walling Modular Enclosures

Area of use The Provita wall rail system is suitable for use

performance PowerBalance, surface mounted Benefits Features Application Specifications

HIGHLY EFFICIENT COOLING FOR YOUR DATA CENTRE

Primus-H. Primus-HV. Primus-HVA. Precise surveying and measuring. Made in Germany

Addendum to the Actalyst Interactive Digital Signage Installation and User s Guide

Modular Table Power System Installation for Runner Non-folding Plug and Play Tables

DRI. VARIZON Displacement unit with adjustable spread pattern

IRONRIDGE PRODUCT CATALOG

combitech system connect 23.5 mm

Durable Metal IP66 Housing

SECTION PROJECTOR LIFTS AND MOUNTS. A. Refer to Section [ Submittal Procedures] [Insert section number and title].

High-tech LED lighting system for interior architecture

Microsoft Azure StorSimple Appliance 8600 Hardware Installation Guide

PQM620 LED Panel luminaire EVO2

Introduction REAR VIEW SAFETY

The Tracking Magnet EVO Recessed High-tech LED lighting system for interior architecture

LASERMET SLIMJIM LED SIGN INSTRUCTION MANUAL LEDS-SJ XXX

AgriMet Weather Station

SW-PM POLE MOUNT BRACKET

SYSTEM 25 SYSTEM 50 AS SYSTEM 63 SYSTEM 75 SYSTEM 100. Alsident System 50. Antistatic (AS) Product Information

Visage. Digital. Remote control. Installation guide. Visage Digital remote control installation instructions Page 1

skyline 70 Fluid Head OPERATOR S MANUAL #1050 Skyline 70 Fluid Head

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)

Operation, installation and service instructions. Lucid nova pro LED luminaire

HBEAM 2 SPECIFICATIONS. QuickShip. HB2 Suspended, Wall. alwusa.com/hb2. Eligible. Find additional images and information at

03 - Aluminum Railing Systems

SECTION [13200] FRAMED 2000 CLEANROOM WALL SYSTEM

Webb Core Cleanroom Wall System

Fixings for Mobile Radio Base Stations

A.A.G. Stucchi TRACK LIGHTING SYSTEM

Product Brochure Edition 1. t: f: e: doncastercables.com

Accessories* NOTE*: order separately; NOTE 1 : 347V stepdown transformer to be installed in a box provided by the customer.

standard construction & overview

free it s as easy as.. and tool one... two... three... Air-Frame Fusion

SP-1800 OWNERS MANUAL

Assembly instructions

PEX Press EN_US_2014_V2.indb 79 2/7/ :15:37 AM

Starlit Dance Floor. User Manual

View Wall Interface. Dynamic Glass INSTALLATION GUIDE. Description. System Requirements. Installation Overview

CMS 503ICT BM. Optimised for Installation

it500 Internet Thermostat INSTALLER MANUAL

CMS 603ICT BM. Optimised for Installation

Instruction Manual. ICENI/TB-02 Terminal Block Module (Type 2) Pub_ Issue 1

A note about our online installation instructions:

3" LED SPECIFICATIONS LOW-PROFILE ADJUSTABLE DOWNLIGHT

Delta Unifence Kit Installation Instructions

HLS House Lighting System

xtablet T1600 Vehicle Holder Installation Guide

Delta Unifence Kit Installation Instructions

GALVANIZED-COATED SHELFING SYSTEM SHELVING FOR FOOD

Transcription:

CEILING & WALL SYSTEMS Between us, ideas become reality CI/SfB (35) Xy April 2011 AXIOM C CANOPY Installation Guide

1 PREPARATION SUSPENSION POINTS Suspension points should be determined before installing the Axiom C Canopy. A suspension point matrix for the different Axiom c modules is included in the cartons. The suspension points matrix is also available on request. Please contact your local ATS department. AXIOM C CANOPY ELEMENTS Item Nr. Description BP 55 14 11 G Axiom C Canopy profile BPC 3000 G BPA WDN 21 H Primary C channel T bar hanger BPA 345 G Axiom Vector MicroLook Tegular Profile corner post! Recommendations Axiom C Canopies should always be installed in accordance with all applicable building codes and regulations. Axiom C Canopy should only be installed on a horizontal plane. They are not approved for exterior installations. Axiom C Canopy should always be installed by a minimum of 2 people. Read the installation instructions included in the carton carefully before starting the installation. Make sure the installation is clean and safe. Any additional weights (such as luminaires...) must be independently suspended from the soffit. In order to avoid scratches or any other damage to the frame DO NOT remove its protective foam until the canopy is in the air. BPA 348 G BPCA 97 G BPA 347 G BPA 346 G BPA 339 H Channel Bracket for Canopy Clamp for C channel 24 mm XL 2 connector clip 15 mm XL 2 connector clip Axiom Universal T bar connector clip

2 THE CHASSIS ON THE FLOOR * The 1.8 x 3.0 m module is used as an example only 112 mm 112 mm Vector MicroLook Tegular Axiom C Canopy profile BP 55 14 11 G 4 Axiom profiles 4 Mitre corner pieces Axiom Profile Corner Post BPA 345 G 3 THE PRIMARY GRID ON THE FLOOR * The 1.8 x module is used as an example only Aircraft cables & Gripple connectors Corner Post BPA 345 G Primary C channel. BPC 3000 G - pre-punched holes at the ends for connector clip 1 Universal T bar connector clip BPA 339 H 3 C channels 6 Universal T bar connector clips Suspension options 1 Universal T bar connector clip BPA 339 H 2 3 OPTION 2 Quick hanger* OPTION 1 6 mm Threaded rod* OPTION 3 Aircraft cable & Gripple * not included in the kit

4 THE GRID - MAIN RUNNER IN THE AIR * The 1.8 x 3.00m module is used as an example only 2 Main runners 12 XL 2 Cross tees 10 Universal T bar connector clips 8 XL 2 Cross tee connector clips 6 Clamps for C channel Set of screws 6 Channel brackets 6 T Bar Hangers Push Main runner Pre cut according to cloud size Pre-punched holes at the end for alignment with Universal T bar connector clip Universal T bar connector clip BPA 339 H T bar hanger BPA WD N 21 H

5 THE GRID - CROSS TEES IN THE AIR Push XL 2 24 mm Cross Tee connector clip BPA 347 G XL 2 15 mm Cross Tee connector clip BPA 346 G 6 THE TILES IN THE AIR * The 1.8 x 3.0 m module is used as an example only 15 Tiles Ceiling Tile 600 x 600 mm

PHYSICAL DATA Material Extruded aluminium profiles Axiom C is made from extruded aluminium, offers better registration, handling capability and finished appearance compared with standard cold-rolled steel. Surface finish Polyester powder coated Armstrong Global White Fire performance Axiom C Canopies, as with other architectural features located in the ceiling plane, may obstruct or skew the existing or planned fire sprinkler water distribution pattern, or possibly delay the activation of the fire sprinkler or fire detection system. Designers and installers are advised to consult a fire protection engineer for guidance on the proper installation techniques where fire detection or suppression systems are present. Recycled content Axiom C Canopy : 50% Ceiling tiles : please contact your local Armstrong office. Warranty For more information, please contact your local Armstrong office. 4 tiles 6 tiles 8 tiles 9 tiles 10 tiles 12 tiles 15 tiles 16 tiles 20 pre-packed, ready-to-assemble Axiom C Canopy kits, in 10 standard modules, will be available either with 15 mm or 24 mm grid: 20 tiles 25 tiles Module Grid system 15 mm XL 2 Grid system 24 mm XL 2 Item Nr. Item Nr. 1200 x 1200 mm BP AX 22 G15 BP AX 22 G24 1800 x 1200 mm BP AX 32 G15 BP AX 32 G24 1800 x 1800 mm BP AX 33 G15 BP AX 33 G24 2400 x 1200 mm BP AX 42 G15 BP AX 42 G24 2400 x 1800 mm BP AX 43 G15 BP AX 43 G24 2400 x 2400 mm BP AX 44 G15 BP AX 44 G24 3000 x 1200 mm BP AX 52 G15 BP AX 52 G24 3000 x 1800 mm BP AX 53 G15 BP AX 53 G24 3000 x 2400 mm BP AX 54 G15 BP AX 54 G24 3000 x 3000 mm BP AX 55 G15 BP AX 55 G24 Main Runner C Channel Fixing Point Ceiling tiles are NOT included in the kit. United Kingdom / Republic of Ireland Armstrong World Industries Ltd. Building Products Division Armstrong House, 38 Market Square Uxbridge UB8 1NG 0800 371849 (UK) 1800 409002 (ROI) FREEFONE Fax: + 44 (0) 1895 274287 www.armstrong-ceilings.co.uk www.armstrong-ceilings.ie sales-support@armstrong.com Advisory note All photographic and design elements supplied in this brochure do not necessarily reflect any recommendation by any of the companies named in this brochure as to the proper use or recommended methods of installation of suspended ceilings and are supplied only as informative material. For technical reasons in printing, differences may appear between colours printed in this brochure and the actual product. The choice of colours should always be made from a sample of the product. All statements and technical information contained in this brochure, or any publication of the companies named in this brochure, relating to Armstrong ceilings are based on results obtained under laboratory test conditions. It is the responsibility of the user to verify with the seller of the products in writing that such statements and information are appropriate to the specific use intended. Sales of the products and liability of the selling companies are in accordance with the terms and conditions of sale of the selling company. All product specifications are subject to modifications without prior notice. PG1100 Job No. 22936 April 2011 Other countries : www.armstrong.eu Printed on chlorine free paper from sustainable resources