IBM TotalStorage SAN256B

Similar documents
IBM TotalStorage SAN256B

IBM TotalStorage SAN Switch M12

IBM TotalStorage SAN Switch F32

IBM TotalStorage SAN Switch F08

IBM System Storage SAN40B-4

IBM System Storage SAN80B-4

IBM System Storage SAN40B-4

IBM System Storage SAN24B-4 Express

IBM System Storage SAN768B

IBM System Storage. Tape Library. A highly scalable, tape solution for System z, IBM Virtualization Engine TS7700 and Open Systems.

IBM System Storage SAN06B-R extension switch

IBM TotalStorage Storage Switch L10

IBM Europe Announcement ZG , dated February 13, 2007

IBM System Storage SAN384B

Interoperability Matrix

IBM TotalStorage 3592 Tape Drive Model J1A

IBM To Resell Cisco Systems MDS 9000 Multilayer Switch and Director Family of Intelligent Storage Networking Products

IBM TotalStorage Enterprise Storage Server Model 800

IBM System Storage DS4800

IBM System Storage TS1120 Tape Drive

Cisco MDS 9000 Enhancements Fabric Manager Server Package Bundle, Mainframe Package Bundle, and 4 Port IP Storage Services Module

IBM System Storage N3000 Express series Modular Disk Storage Systems

Copyright International Business Machines Corporation 2008, 2009, 2010, 2011, 2012, 2013 All rights reserved.

Brocade 20-port 8Gb SAN Switch Modules for BladeCenter

IBM System Storage DS5020 Express

IBM System Storage DS6800

Interoperability Matrix

As enterprise organizations face the major

4 Gbps and 10 Gbps switching modules available for Cisco MDS 9000 family of products

IBM System Storage SAN768B and SAN384B

IBM System Storage DS5020 Express

IBM TotalStorage Enterprise Storage Server (ESS) Model 750

IBM TotalStorage Enterprise Storage Server Model 800

The IBM Systems Storage SAN768B announces native Fibre Channel routing

Flex System FC5024D 4-port 16Gb FC Adapter Lenovo Press Product Guide

Cisco MDS 9000 Series Switches

FUJITSU NETWORKING BROCADE 7800 EXTENSION SWITCH

Flex System FC port 16Gb FC Adapter Lenovo Press Product Guide

IBM TotalStorage FAStT900 Storage Server New Offering Expands IBM SAN Storage Solutions

IBM expands multiprotocol storage offerings with new products from Cisco Systems

QuickSpecs. HP StorageWorks SAN Switch 2/16-EL B-Series Family. Overview

IBM Ethernet Switch J08E and IBM Ethernet Switch J16E

Cisco MDS 9000 Series Switches

IBM and BROCADE Building the Data Center of the Future with IBM Systems Storage, DCF and IBM System Storage SAN768B Fabric Backbone

QuickSpecs. HP StorageWorks SAN Switch 2/8V and 2/8V Power Pack B-Series Family. Overview

QuickSpecs. StorageWorks SAN Switch 2/8-EL by Compaq. Overview

Cisco Systems 4 Gb 20-port and 10-port Fibre Channel Switch Modules for BladeCenter

New Cisco MDS 9020 Fabric Switch offers 4, 2 and 1 Gbps Fibre Channel switch connectivity

Flex System FC port 8Gb FC Adapter Lenovo Press Product Guide

IBM System Storage SAN768B-2 and SAN384B-2

IBM _` p5 570 servers

QuickSpecs. Key Features and Benefits. HP StorageWorks 4/16 SAN Switch and 4/16 SAN Switch Power Pack Family. Overview

Exam : S Title : Snia Storage Network Management/Administration. Version : Demo

BROCADE 8000 SWITCH FREQUENTLY ASKED QUESTIONS

IBM System Storage. Meeting the storage needs of SMB with modular systems and storage solutions from IBM

QuickSpecs. HP StorageWorks SAN Switch 2/32 & SAN Switch 2/32 Power Pack B-Series Family. Overview

CONNECTRIX DS-6500B SWITCHES

p5 520 server Robust entry system designed for the on demand world Highlights

IBM TotalStorage Enterprise Tape Library 3494

SMART SERVER AND STORAGE SOLUTIONS FOR GROWING BUSINESSES

Understanding FICON Performance

IBM System Storage SAN 384B and IBM System Storage SAN 768B add features

Why You Should Deploy Switched-FICON. David Lytle, BCAF Global Solutions Architect System z Technologies and Solutions Brocade

IBM System Storage SAN06B-R Extension Switch IBM Redbooks Product Guide

IBM IBM Open Systems Storage Solutions Version 4. Download Full Version :

IBM LTO Ultrium 5 Half High Tape Drive

Brocade s Mainframe and FICON Presentations and Seminars that are available to Customers and Partners

QuickSpecs. HP StorageWorks DC Backbone Director Overview

CONNECTRIX MDS-9250I SWITCH

IBM Storwize V5000 disk system

IBM TotalStorage Enterprise Tape Library 3494

IBM System p5 550 and 550Q Express servers

Large SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors

IBM Flex System FC5024D 4-port 16Gb FC Adapter IBM Redbooks Product Guide

IBM System p5 510 and 510Q Express Servers

QuickSpecs. HP StorageWorks DC Backbone Director Overview

IBM System p5 185 Express Server

Transport is now key for extended SAN applications. Main factors required in SAN interconnect transport solutions are:

IBM Z servers running Oracle Database 12c on Linux

IBM TS4300 Tape Library

SUN BLADE 6000 VIRTUALIZED 40 GbE NETWORK EXPRESS MODULE

Virtualisation, tiered storage, space management How does it all fit together?

Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide

WELCOME TO TIVOLI NOW!

IBM Flex System FC port 8Gb FC Adapter IBM Redbooks Product Guide

Over 70% of servers within a data center are not connected to Fibre Channel SANs for any of the following reasons:

How Smarter Systems Deliver Smarter Economics and Optimized Business Continuity

Brocade Technology Conference Call: Data Center Infrastructure Business Unit Breakthrough Capabilities for the Evolving Data Center Network

Quick Reference Guide

HP Converged Network Switches and Adapters. HP StorageWorks 2408 Converged Network Switch

Cisco MDS 9000 Port Analyzer Adapter, Enhanced: New version improves performance monitoring

Real Time COPY. Provide Disaster Recovery NOT to maintain two identical copies Provide I/O consistent copy of data

Cisco MDS 9513 Multilayer Director offers new levels of scalability for the MDS family, providing up to 528 ports at 1, 2, and 4 Gbps

EMC SYMMETRIX VMAX 40K STORAGE SYSTEM

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

Flex System FC port and FC port 16Gb FC Adapters Lenovo Press Product Guide

STORAGETEK SL150 MODULAR TAPE LIBRARY

CONNECTRIX ED-DCX8510B ENTERPRISE DIRECTORS

IBM TotalStorage SAN portfolio expands with a SAN24M-1 mid-range switch and a SAN12M-1 entry switch for infrastructure simplification

PrepAwayExam. High-efficient Exam Materials are the best high pass-rate Exam Dumps

Transcription:

High performance and scalability for the most demanding enterprise SAN requirements IBM TotalStorage SAN256B The IBM TotalStorage SAN256B is designed to provide outstanding performance, enhanced scalability and a design ready for high-performance 4 Gbps and 10 Gbps capable hardware and expanded capability features. The SAN256B is well suited to address enterprise SAN customer requirements for infrastructure simplification and improved business continuity. Improved port density enables up to 384 ports in 14U vertical rack space to maximize datacenter efficiency Highlights High availability with built-in iscsi blade enables servers redundancy designed to avoid to access storage over IP single points of failure (Ethernet) in a highly integrated, cost-effective manner Highly scalable director with for storage consolidation 16, 32 or 48 ports per port switch blade and from 16 to 10 Gbps Fibre Channel blade 384 ports in a single domain provides extended distance ISL connectivity between directors Multiprotocol router blade with over dark fibre or DWDM sixteen Fibre Channel (FC) ports and two Internet Protocol (IP) Sixteen and thirty-two port ports for SAN routing and distance extension over IP IBM FICON Director switching switch blades support with Fibre Channel/FICON intermix, FICON CUP (Control Unit Port) and FICON cascading The SAN256B director interoperates with other members of the IBM TotalStorage SAN b-type family. It can be configured with a wide range of highly scalable solutions that address demands for integrated IBM System z and open system server enterprise SANs. High availability design The SAN256B director is designed to provide director-class high availability with redundant, hot-pluggable components to avoid single points of

failure. Redundant control processors, power supplies and fans provide a design for concurrent hardware and firmware maintenance and upgrade without disruption to network operation. Fabric Operating System firmware is designed to enable non-disruptive stateful control processor failover and concurrent firmware activation. Advanced security features can enforce fabric-wide change control policies that can help reduce potential downtime due to operator errors. Optional Fabric Manager software provides Call Home capabilities. Enhanced performance The SAN256B director is built upon technology that provides Fibre Channel link speeds of 10, 4, 2 and 1 Gigabits per second (Gbps) (requires storage system hardware that supports 4 Gbps throughput). Each FC switch port supports 400 MBps, 200 MBps or 100 MBps full-duplex, non-blocking performance. Auto-sensing ports are capable of automatically negotiating to the highest speed supported by the attached server, storage system, switch, router or director. IP ports support one Gigabit Ethernet (GbE). Each iscsi blade can provide IP (Ethernet) access via GbE, while each 10 Gbps FC port can provide local or extended distance ISL connectivity between directors. The SAN256B can be used to expand an existing core-to-edge SAN fabric infrastructure. As SAN256B directors are added to the core, installed SAN switches or directors can be migrated to the edge. The high density of the SAN256B also makes it suitable for installation at the edge of the SAN for server aggregation. These approaches help support scalable network growth in a modular, cost-effective and non-disruptive manner while customers continue to derive benefit from installed SAN infrastructure devices. Enhanced scalability The SAN256B is scalable from 16 to 384 Fibre Channel (FC) ports, up to four Internet Protocol (IP) ports or up to 48 10 Gbps FC ISL ports in a single domain. This capability provides three times the number of switch ports compared to the prior generation IBM TotalStorage SAN Switch M14, making for fewer elements to manage in large-scale SANs. The M14/M48 16-port 4 Gbps Switch Blade feature expands connectivity in sixteen port increments. The M48 32-port 4 Gbps Switch Blade feature expands connectivity in thirty-two port increments. And the M48 48-port 4 Gbps Switch Blade expands connectivity in forty-eight port increments. The M48 FC Routing Blade expands connectivity in sixteen port increments plus adds two GbE IP ports. The two GbE ports enable reliable SAN extension across suboptimal Wide Area Networks (WANs) through the use of Fast Write, hardware-based compression and storage-optimized protocol enhancements. The M48 iscsi Blade provides cost-effective connectivity to servers over IP interfaces, and the M48 10 Gbps Fibre Channel Blade provides local and extended distance ISL connectivity. A mixture of shortwave and longwave SFP optical transceiver features can be installed on a portby-port basis. Advanced Inter-Switch Link (ISL) Trunking ISL Trunking enables as many as eight 4 Gbps Fibre Channel links to be combined to form a single logical ISL between IBM SAN256B directors and IBM System Storage SAN32B-3 or IBM System Storage SAN64B-2 switches or IBM System Storage SAN18B-R routers for an aggregate bandwidth of up to 32 Gbps. Up to four 4 Gbps links can be combined to form a single ISL between SAN256B directors and IBM TotalStorage SAN16B-2 or SAN16B-2 Express Model switches for an aggregate bandwidth of up to 16 Gbps. The SAN256B is also backward compatible with previous generation directors and switches

that operate at 2 Gbps. Connection to IBM M14 and M12 SAN directors and other IBM SAN switches enables up to four links to form a single logical ISL with an aggregate speed of up to 8 Gbps. Advanced ISL Trunking provides additional scalability by enabling SAN256B, M14 and M12 directors to be networked in an expandable core as part of a core-to-edge SAN fabric. High-speed ISL trunks are designed to automatically optimize bandwidth utilization and help enhance availability. ISL trunks can help simplify administration and provide more flexibility when connecting multiple high-performance devices to the SAN fabric because they eliminate the need to manage traffic over a single link between interconnected switches. Administrators only need to monitor performance of the ISL trunk rather than performance of specific devices routed across the trunk. Failures of individual links do not require rerouting of traffic, which can help increase network reliability and performance. Advanced multiprotocol routing Since the introduction of Storage Area Networks, customers have built multiple SAN networks (or islands) for different applications, often with fabric switch components from different manufacturers. Some islands were built by different departments within a company, while other islands resulted from mergers, acquisitions or reorganizations. Dissimilar SAN equipment with different capabilities or a desire to isolate important applications has constrained opportunities for enhanced infrastructure simplification and vital business continuity solutions. The M48 FC Routing Blade provides Fibre Channel FC-FC Routing Service, which allows the interconnection of multiple SAN islands without requiring that the separate fabrics be merged into a single large SAN. This capability can help create a tiered or extended enterprise SAN infrastructure without having to redesign or reconfigure the entire environment. FC-FC Routing Service is designed to allow devices located on separate SAN fabrics to communicate without merging the fabrics into a single large SAN environment. This routed network consists of multiple individual SAN fabrics for one large storage network, known as a MetaSAN. Local site infrastructure simplification solutions may be extended to one or many remote sites for enhanced data protection and disaster tolerance. The M48 FC Routing Blade provides Fibre Channel over IP and FCIP Tunneling Service for distance extension, which can enable cost effective and manageable metro and global business continuity solutions. The ability to encrypt data transmitted over an IP link is designed to provide additional security and data protection. This extended distance connectivity can help create consolidated remote tape vaulting data protection plus metro mirror and global mirror disk-based disaster tolerant solutions. FCIP Tunneling Service is designed to allow organizations to extend Fibre Channel SANs over longer distances using an IP-based Metropolitan Area Network (MAN) or Wide Area Network (WAN) infrastructure. This service can be integrated with the FC-FC Routing Service. Such integration helps prevent faults on MAN/WAN links from propagating between sites and can help enable a more secure distanceconnectivity infrastructure for disaster recovery applications. iscsi connection Many enterprises have a large number of lower-cost servers that are not connected to a consolidated SAN infrastructure primarily because of cost constraints. The M48 iscsi Blade

can provide a means to enable these servers to gain access to efficient, large-capacity fibre channel storage resources via a robust, highperformance, highly scalable SAN infrastructure. High-speed ISL connectivity The M48 10 Gbps Fibre Channel Blade is designed to provide ISL connectivity between local or remote directors. Full data-rate connection to 10 Gbps Dense Wave Division Multiplexor (DWDM) links are supported across extended distances. End-to-end performance monitoring Advanced switching technology across all IBM TotalStorage SAN b-type directors and switches features Frame Filtering, which is based on additional information contained in several fields in both a network packet header and payload. Frame Filtering enables intelligent fabric services such as end-to-end performance analysis. SAN256B directors with Frame Filtering can provide detailed information at the director, port and frame levels. This information can be used to monitor performance from a specific server to a specific storage device port across an entire core-to-edge SAN fabric. Performance Monitoring Performance Monitoring is a standard capability of SAN256B directors that leverages Frame Filtering capabilities for end-to-end performance monitoring. As core-to-edge SAN fabrics scale to thousands of devices, Advanced ISL Trunking and Frame Filtering can help simplify storage management and reduce the overall cost of the storage infrastructure. FICON Director operation IBM FICON Director switching supports FICON servers, intermixed FICON and Open servers and FICON cascading between two directors. M48 FICON CUP Activation feature provides Control Unit Port (CUP) inband management function designed to allow mainframe applications to perform configuration, monitoring, management and statistics collection. These applications include System Automation for IBM OS/390 (SA/390), Dynamic Channel Management Facility (DCM) and Resource Management Facility (RMF). Enhanced Call Home and RAS capabilities can help simplify management. Hardware-enforced FICON and FCP port zoning enhances separation with intermix operation. Advanced ISL Trunking with self-optimizing traffic management can help enhance the performance and availability of FICON cascading. M48 Advanced Security Activation feature is required for FICON cascading. M48 FICON with CUP, Advanced Security Bundle feature provides both capabilities in a robust package. (FICON and M48 FICON CUP Activation are not supported on the M48 48-port 4 Gbps Switch Blade.) Industry-standard Fibre Channel SAN256B directors support the interconnection of multiple IBM SAN switches and directors. The interconnection of IBM TotalStorage SAN b-type family members (2005, 2109, 3534) and compatible switches, directors and routers (Brocade Silkworm 200E, 2400, 2800, 3200, 3800, 3900, 4100, 4900, 7500, 12000, 24000, 48000 and Multiprotocol Routers) can support the creation of scalable, dual redundant core-to-edge SAN fabrics that can support high-performance, scalable and fault tolerant infrastructure simplification and business continuity solutions such as storage consolidation, data protection, disaster tolerance and data sharing. Common IBM SAN capabilities IBM TotalStorage SAN b-type switches and directors include universal ports that can automatically determine the

port type when connected to a fabric port (F_port), fabric loop port (FL_port) or expansion port (E_port). Fabric services include automatic self-discovery of new devices and dynamic path selection based upon Fabric Shortest Path First (FSPF), which is designed to select the most efficient routing in a SAN fabric. Common IBM SAN switch firmware Common switch firmware helps simplify SAN fabric expansion. Standardsbased Management Server and Simple Name Server support in-band discovery of SAN fabric changes. Management access of SNMP information is provided via an external Ethernet interface or in-band over a Fibre Channel link through a single fabric connection. Device-level zoning of the SAN fabric enables administrators to create separate segments or zones within the SAN fabric to separate different application servers and devices in heterogeneous SAN environments. Zones may be dynamically created and changed from any switch in a fabric. Basic security functions such as hardware-enforced zoning are standard. Open fabric management The IBM TotalStorage SAN b-type management framework is designed to support the widest range of solutions, from very small workgroup SANs up to very large enterprise SAN fabrics with thousands of devices. Small SANs require rapid deployment and plug-andplay simplicity. Very large SAN fabrics require centralized management and automated administration. IBM SAN b-type switch management options include browser-based Web Tools, Fabric Watch, Fabric Manager and open standards-based interfaces to enterprise SAN managers. Advanced Web Tools is a standard function designed to provide a Web browser interface for flexible, easyto-use integration into existing enterprise storage management structures. Web Tools is designed to support security and data integrity by limiting host system attachment to specific storage systems and devices through zoning. Fabric Watch is either a standard function or an optional feature on IBM TotalStorage SAN b-type family members. Fabric Watch threshold monitoring tracks the health of switches and SAN fabrics. It is designed to monitor fabric resources, port traffic, switch environmental values and operational values for Small Form-factor Pluggable (SFP) optical transceivers. This information is accessible from Web Tools and Fabric Manager. When used with IBM TotalStorage b-type family members, Web Tools provides an easy-to-use interface to intelligent fabric features such as end-to-end performance monitoring and ISL Trunking. Optional features M48 Remote Switch Activation Remote Switch Activation feature extends the distance of SAN fabrics by enabling two Fibre Channel switches to interconnect across a Wide Area Network (WAN). With this feature, one can stage and manage data transfers across a pair of Fibre Channel switches connected to a pair of CNT Storage Routers. M48 Extended Fabric Activation Extended Fabric Activation feature extends SAN fabrics beyond the Fibre Channel standard 10 km. This helps enable high performance over extended distances for data protection and business continuity solutions. Extended distance longwave SFP transceivers are available for 35 km and 80 km distances. Extended Fabric Activation helps optimize switch buffering to support high gateway switch ISL performance.

M48 Advanced Security Activation As entry level and departmental SAN islands evolve into large enterprise SANs within the datacenter and across Wide Area Networks (WANs), advanced security is required to control and manage fabric access. External threats and internal operational events can compromise valuable enterprise data assets and create data integrity exposures. Advanced Security Activation feature can help create a secure storage networking infrastructure required for SAN island consolidation. Advanced Security Activation extends basic fabric security provided by Advanced Zoning hardware-enforced World Wide Name (WWN) zoning. It provides a policybased security system for IBM SAN switch fabrics with Fabric OS versions 3, 4 and 5. Prior generation switch investment protection is provided with support for Fabric OS version 2.6.2. All switches in an Advanced Security fabric must be upgraded before Advanced Security can be deployed. M48 FICON with CUP Activation FICON with CUP Activation feature provides support for FICON on IBM System z servers. (FICON and M48 FICON CUP Activation are not supported on the M48 48-port 4 Gbps Switch Blade.) M48 FICON with CUP, Advanced Security Bundle FICON with CUP Activation and Advanced Security Bundle provides support for both FICON on IBM eserver zseries servers and Advanced Security in one package. M14/M48 N_Port ID Virtualization N_Port ID Virtualization (NPIV) provides support for selected attached IBM System z Fibre Channel Protocol (FCP) channels and is designed to allow the sharing of a single physical FCP channel among operating system images, whether in LPARs or as IBM z/vm guests in virtual machines. NPIV helps to improve I/O performance with increased resource sharing and channel utilization of FCP channels among operating system images in LPARs or virtual machines and helps to facilitate infrastructure simplification with virtual channel administration and management. M48 FCIP Activation M48 FCIP Activation enables organizations to extend their Fibre Channel SANs over longer distances that would be impractical or too expensive with native Fibre Channel or in situations where dark fibre resources are unavailable but in which IP connectivity already exists. Eight virtual FCIP tunnels per IP port help maximize scalability and utilization of MAN/WAN resources. Related products Fabric Manager Fabric Manager is a powerful tool to help simplify management, reduce cost of administration and accelerate deployment and provisioning. Fabric Manager provides a Java technology-based application that can help simplify management of a complex, multiple switch fabric. Web Tools and Fabric Manager work together on the same management server which can access any switch in a core-to-edge fabric. Fabric Manager requires a Microsoft Windows NT, Windows 2000 or Sun Solaris 7 server with a Netscape or Internet Explorer Web browser. Fabric Manager is available through IBM as a separate software program. IBM SAN Cabinet C36 The C36 Cabinet is based on a standard 19-inch rack and offers 36U vertical space. It is specifically designed to support up to two SAN256B, M14 or M12 directors with two power distribution units, each with three power outlets. Alternative configurations consisting of a SAN256B director plus other members of the IBM TotalStorage SAN b-type family are possible. Please consult the Web at ibm.com/storage/san/b_type for specific configuration options and attachment capabilities.

IBM TotalStorage SAN256B at a glance Product characteristics Product number Base fabric director Fibre Channel interfaces FICON interfaces IP interfaces Optical transceivers Fans and power supplies Hot-swap components Rack support Non-rack support Management software Servers supported Operating systems supported Storage products supported Fibre Channel switches supported Fibre optic cable Warranty (standard) Optional features Physical characteristics Height (rack mount) Width Depth (with door) Weight (without media) Operating environment Temperature Relative humidity Electrical requirement Power 2109-M48 Base chassis includes two control processor blades and slots for one to eight blades E-Port, F_Port, FL-Port 4 Gigabits per second (Gbps) 1 gigabite Ethernet 4 Gbps SFP and 10 Gbps XFP short wave and long wave Dual power supplies and blowers SFP and XFP optical transceivers, control processor blades, switch, routing, iscsi and 10 Gbps blades, power supplies, blowers IBM TotalStorage SAN Cabinet C36 only Non-rack installation is not supported Web Tools, Fabric Watch, Performance Monitor IBM System z and IBM eserver zseries servers; IBM System x and IBM eserver xseries servers; IBM System p and IBM eserver pseries servers; IBM System i and IBM eserver iseries servers; Other Intel processor-based servers; Selected Sun and HP servers; IBM System Storage SAN Volume Controller (SVC) IBM z/os, AIX and OS/400, Microsoft Windows 2000, Windows 2003; Red Hat Linux, Red Hat Linux Advanced Server; SUSE Linux, SUSE Linux Enterprise Server (SLES); United Linux; Novell NetWare IBM System Storage DS8000 series; IBM System Storage DS6000 series; IBM System Storage DS4000 series; IBM TotalStorage Enterprise Storage Server ; IBM TotalStorage 357x, 358x, and 359x Tape Drives and Libraries (not supported with 3590 or LTO ; Generation 1 Tape Drives); IBM TotalStorage 3494 Tape Library when using 3592 Tape Drives; Other selected storage systems IBM TotalStorage SAN b-type switches, directors and routers Other switches, directors and routers manufactured by Brocade Fibre optic cables are required and are available in various lengths in single mode and multimode formats 1-year; Customer Replaceable Unit (CRU) Service and IBM On-site Repair; warranty service upgrades are available M48 Remote Switch Activation; M48 Extended Fabric Activation; M48 Advanced Security Activation; M48 FICON with CUP Activation; M48 FICON with CUP, Advanced Security Bundle; M14/M48 N_Port ID Virtualization, M48 FCIP Activation, 2 Additional Power Supplies 61.24 cm/24.11 in 43.74 cm/17.22 in 74.20 cm/29.20 in 98 kg/216 lbs 0 to 40 degrees C 20% to 85% at 40 degrees C 240 or 208 VAC

For more information Contact your IBM representative or IBM Business Partner or visit: ibm.com/storage/san/b_type IBM is not responsible for the performance or interoperability of any non-ibm products discussed herein. Performance data for IBM and non-ibm products and services contained in this document was derived under specific operating and environmental conditions. The actual results obtained by any party implementing such products or services will depend on a large number of factors specific to such party s operating environment and may vary significantly. IBM makes no representation that these results can be expected or obtained in any implementation of any such products or services. MB, GB and TB equal 1,000,000, 1,000,000,000 and 1,000,000,000,000 bytes, respectively, where referring to storage capacity. Actual storage capacity will vary based upon many factors and may be less than stated. Some numbers given for storage capacities give capacity in native mode followed by capacity using data compression technology. THE INFORMATION IN THIS DOCUMENT IS PROVIDED AS-IS WITHOUT ANY WARRANTY, EITHER EXPRESSED OR IMPLIED. IBM EXPRESSLY DISCLAIMS ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT. IBM products are warranted according to the terms and conditions of the agreements (e.g., IBM Customer Agreement, Statement of Limited Warranty, International Program License Agreement, etc.) under which they are provided. References in this document to IBM products, programs or services do not imply that IBM intends to make such products, programs or services available in all countries in which IBM operates or does business. Any reference to an IBM program or product in this document is not intended to state or imply that only that program may be used. Any functionally equivalent program or product that does not infringe IBM s intellectual property rights may be used instead. It is the user s responsibility to evaluate and verify the operation of any non- IBM product, program or service. IBM s customer is responsible for ensuring its own compliance with legal requirements. It is the customer s sole responsibility to obtain advice of competent legal counsel as to the identification and interpretation of any relevant laws and regulatory requirements that may affect the customer s business and any actions the customer may need to take to comply with such laws. IBM does not provide legal advice or represent or warrant that its services or products will ensure that the customer is in compliance with any law. Copyright IBM Corporation 2007 IBM Systems and Technology Group Route 100 Somers, New York 10589 Produced in the United States August 2007 All Rights Reserved IBM, the IBM logo, eserver, iseries, pseries, System z, System x, System p, System i, AIX, DS4000, DS6000, DS8000, Enterprise Storage Server, FICON, OS/390, OS/400, System Storage, TotalStorage, xseries, zseries, z/vm and z/os are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries or both. Intel is a registered trademark of Intel Corporation in the United States, other countries or both. Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc. in the United States, other countries or both. Microsoft, Windows and Windows NT are registered trademarks of Microsoft Corporation in the United States, other countries or both. Novell and NetWare are registered trademarks of Novell, Inc., in the United States and other countries. Linear Tape Open, LTO and Ultrium are trademarks of Hewlett Packard, IBM and Certance in the United States, other countries or both. Linux is a trademark of Linus Torvalds in the United States, other countries or both. UNIX is a registered trademark of The Open Group in the United States and other countries. Other company, product and service names may be trademarks or service marks of others. This document could include technical inaccuracies or typographical errors. IBM may make changes, improvements or alterations to the products, programs and services described in this document, including termination of such products, programs and services, at any time and without notice. Any statements regarding IBM s future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only. The information contained in this document is current as of the initial date of publication only and is subject to change without notice. IBM shall have no responsibility to update such information. TSD01242-USEN-04