Assembly. Front view. LED yellow: Relay output I. LED yellow: Relay output II

Similar documents
Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Contact protection relay

Displays Transducers. Displays and transducers

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

Operating instructions. Switching amplifier DN0210 DN / / 2015

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

02/11/2015

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Amplifiers, Counters, Timers & Controls

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

02/11/2015

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs

Electronic timer CT-ERD.12

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

Process displays For current and voltage

02/11/2015

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

08/07/2015

Electronic timer CT-AHD.22

Safety controller unit B1 /

Dimensions. Model Number. Electrical connection emitter. Features. Electrical connection receiver. Product information. Pinout OBE12M-R100-S2EP-IO-V31

Time Counters mini "h", DC Version

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2

RM4JA01F current measurement relay RM4-J - range ma V AC

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Electronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts

Electronic timer CT-ERS.21

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

RM35LM33MW liquid level control relay RM35-L V AC/DC

XPSMCMDI Input expansion module with screw term

Technical Data. General specifications. Rated operating distance s n 3 mm

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

PSR-PS21. SIL coupling relay. Data sheet. 1 Description

02/11/2015

02/11/2015

RM4JA32MW current measurement relay RM4-J - range A V AC DC

MBM - Modular I/O system IP20

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

QUINT-PS/ 1AC/24DC/ 5

Assembly. Function 41

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

SYSMAC Remote Transistor Module

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

FACTORY AUTOMATION. Manual Speed Monitor KFU8-DW-1.D

Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

5 Fieldbus Technology

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

XPSMCMDO Digital output pairs expansion modules with screw term

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Electronic timer CT-ARS.11

RM4UA33M voltage measurement relay RM4-U - range V V AC

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

MINI MCR-SL-PT100-UI(-SP)(-NC)

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

Solid State Remote Power Controller E /627

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Zelio Control-modular measurement and control relays 1

RM35TF V AC

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

D5090S INSTRUCTION MANUAL. D A SIL 3 Relay Output Module for NE Load. DIN-Rail and Termination Board, Model D5090S

QUINT-PS AC/24DC/10

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PHOENIX CONTACT Features

Three-phase monitoring relay

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Transcription:

Switch Amplifier, Timer Relay Features 1-channel signal conditioner Universal usage at different power supplies 3-wire PNP/NPN sensor or push-pull input 2 relay contact outputs Adjustable energized/de-energized delay Function This signal conditioner converts the state of 3-wire sensors (PNP or NPN) or sensors with push-pull output stages into two relay outputs. It has one input and two form C changeover relay outputs. The switch amplifier has an adjustable energized/deenergized delay for the relay outputs. The start-up time of the device is as long as the time setting value + 500 ms. Assembly Front view Rotary switch S6, S7: Time adjustment LED yellow: Relay output I LED yellow: Relay output S1 S2 S3 S4 S5 1 2 3 4 5 6 OUT1 OUT2 PWR 7 8 9 10 11 12 13 14 15 Removable terminal green LED green: Power supply Switch S4: (mode of operation output I) Switch S1: I (sensor type) Switch S5: (mode of operation output ) Switch S2: (Time base 0.1 s/1 s) Switch S3: (energized/de-energized delay) Removable terminals green Connection 1+ 2 3-7 8 9 10 11 12 14 15 I AC/DC 1

General specifications Signal type Digital Input Supply Connection terminals 14, 15 Rated voltage U r 20... 48 V DC or 90... 253 V AC, 45... 65 Hz Rated current I r 230 ma Power dissipation 2.3 W Power consumption 4.5 W Input Connection side field side Connection terminals 1+, 2, 3- Rated values 22... 24 V DC / 100 ma, see additional information Short-circuit current 125 ma Switching point PNP: 0-signal: < 12.5 V 1-signal: > 13.5 V NPN and push-pull output: 0-signal: < 4.5 V 1-signal: > 5.5 V Output Connection side control side Additional functions Connection output I: terminals 7, 8, 9 output : terminals 10, 11, 12 Output I, signal, relay Contact loading 250 V AC / 2 A / cos φ 0.7 ; 125 V AC/4 A/ cos φ > 0.7 ; 40 V DC / 2 A Mechanical life 20 x 10 6 switching cycles Electrical life 0.2 x 10 6 switching cycles (40 V DC, 2 A, ohmic) 0.4 x 10 6 switching cycles (253 V AC, 2 A, cos φ = 1) 0.25 x 10 6 switching cycles (253 V AC, 2 A, cos φ = 0.7) Minimum load 50 mw, 5 V DC Energized/De-energized delay 90 ms / 90 ms Transfer characteristics Switching frequency 5 Hz for delay 0 s adjustable energized/de-energized delay: 0... 79 s Galvanic isolation Input/Output Input/power supply Output/power supply Output/Output Indicators/settings Display elements LEDs Control elements DIP-switch Configuration via DIP switches Labeling space for labeling at the front Directive conformity Electromagnetic compatibility Directive 2014/30/EU EN 61326-1:2013 (industrial locations) Low voltage Directive 2014/35/EU EN 61010-1:2010 Conformity Electromagnetic compatibility NE 21:2012 Degree of protection IEC 60529:2001 Ambient conditions Ambient temperature -20... 60 C (-4... 140 F) Mechanical specifications Degree of protection IP20 Connection screw terminals Mass approx. 166 g Dimensions 20 x 119 x 115 mm (0.8 x 4.7 x 4.5 inch), housing type B2 Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001 Data for application in connection with hazardous areas Supply 48 V DC Certificate PF 10 CERT 1417 X Marking 3G Ex na nc C T4 Gc 2

Output I, Contact loading 50 V AC/2 A/cos φ > 0.7; 40 V DC/1 A resistive load Directive conformity Directive 2014/34/EU EN 60079-0:2012+A11:2013, EN 60079-15:2010 General information Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. 3

Function The single-channel switch amplifier has one input and two relay outputs (change-over contacts). The input circuit can process signals from sensors that have either PNP/NPN output transistors or push-pull outputs. If sensors have NPN or push-pull outputs, switch S1 must be set to position I. If sensors have PNP output transistors, switch S1 must be set to position. The output switching characteristics (switch S4 for output I, switch S5 for output ) can be selected: Relay activated for closed sensor contact (for pull-push outputs, contact between terminals 2 and 3 closed) switch S4 or S5 in position I. Relay deactivated for open sensor contact (for pull-push outputs, contact between terminals 2 and 3 open) switch S4 or S5 in position. The switch amplifier has an adjustable energized/de-energized delay for the relay outputs. Switch S3 = I activates the energized delay and switch S3 = activates the de-energized delay. Depending on switch S2 (default time setting 0.1 s/1 s), the delay time can be set to between approx. 0.1 s and 7.9 s (for S2 = I) or between approx. 1 s and 79 s for (S2 = ) using switches S6 and S7. The delay times add up to the shortest possible response times and have a tolerance of 10 %. Switch S6 has a value range of 0 to 7, which is used to set the decimal power of the delay; switch S7 has a value range of 0... 9, which is used to set the single power of the delay. If the default time setting of S2 = I, S6 = 0 and S7 = 0, the response time constant of the switch amplifier for the undelayed slope (see switch position S3) is < 20 ms and for the delayed slope < 90 ms. These are the shortest possible response times. Sensor connection NPN output/contact S1 = I 2 3- PNP output/contact S1 = 1+ 2 Push-pull output S1 = I 1+ 2 3-4

Note The sensor currents are derated in line with the ambient temperature The maximum value of the sensor currents is controlled by a thermal overload protection on the device. The device measures the ambient temperature and limits the sensor currents accordingly (see figure). An inadmissibly high ambient temperature can limit the function of the sensors. Achtung 100 Current in ma 90 80 70 60 50 40 30 20 10 Attention! The maximum current for sensor supply is 100 ma. 10 20 30 40 50 60 Ambient temperature in C 5

Configuration Function of the DIP switch S1 S2 S3 S4 S5 1 2 3 4 5 6 OUT1 OUT2 PWR I 7 8 9 10 11 12 13 14 15 S1 S2 S3 S4 S5 1 2 3 4 5 I S Function Position 1 Sensor type Input: Push-pull output, NO contact, NPN I Input: PNP, NO contact 2 Default time Default time = 0.1 s x (time setting value of switches I S6 and S7) Default time = 1 s x (time setting value of switches S6 and S7) 3 Operating mode ON delay, minimum input pulse length I OFF delay, minimum output pulse length 4 Direction detection Output I activated if sensor closed I Output I activated if sensor open 5 Direction detection Output activated if sensor closed I Output activated if sensor open Default setting: switches 1, 3, 4 and 5 to position I and switch 2 to position Function of the rotary switch S Function Position 6 Time setting Decimal value 0... 7 x 10 x (default time setting value 0... 7 of switch S2) 7 Time setting Decimal value 0... 9 x (default time setting value of switch S2) 0... 9 Default setting: switches 6 and 7 to position 0 6