HYPERFRAME CABINET & ENCLOSURE SOLUTIONS
PERFECT BALANCE OF FORM, FIT AND FUNCTION CABINET & ENCLOSURE SOLUTIONS Our philosophy is simple, to provide you with a complete and innovative solution that meets 100% of your needs. Specific network architectures, hardware requirements and site related challenges dictate an individualized solution that often requires extreme creativity in designs and product solutions. AFL Hyperscale s Cabinet & Enclosure Systems provide you with speed and flexibility in customization to keep pace with rapidly evolving Data Center infrastructure requirements. Our process and design address rapid deployment and cable management challenges associated with the ever increasing cabling densities required in data center environments. www.aflhyperscale.com KEY FEATURES Pre-configured to your specific cabinet, power, security and cable management requirements Complimentary pre-installation of AFL Hyperscale PDUs Standard & Customizable Sizes & Configurations 1st Article creation for Customer specific applications Up to 3000 lb Static & 2250 lb Dynamic Load Capacity Affordable Electronic Access Control Perforated doors are 78% open to maximize airflow Wide range of thermal & cable management accessories APPLICATIONS Years of developing customer specific applications has evolved into a systematic and innovative approach to help you respond faster to lights on deployments. Hyperscale, Colocation & Enterprise Data Centers High Count Optical Fiber Cable Management POD Applications & Data Center Labs Meet-Me Rooms (MMR) & Fiber Entry Solutions Data Center Inter-Hall and Intra-Hall Distribution 02
CUSTOMIZED TO SUIT YOUR NEEDS Pre-configured to your specific applications & deployment requirements POWER Pre-installation of PDUs configured to your specific power requirements SECURITY & ENVIRONMENTAL Integration with electronic locks & environmental monitoring CABLE MANAGEMENT INTRA-RACK CABLING RAPID DEPLOYMENT Pre-installation of cable management accessories Harness Kits for switch port distribution, replication and server deployments Simplified ordering & reduced packaging, waste and installation time 03
04 SPECIFICATIONS INCLUDES EQUIPMENT SPACE LOAD CAPACITY, 6-SLIDE FRAME (PER UL2416) LOAD CAPACITY, 4-SLIDE FRAME (PER UL2416) CERTIFICATIONS MATERIAL FINISH ENVIRONMENT CONSTRUCTION DOORS/LOCK KITS RAILS GROUNDING/BONDING STANDARD SIZES Welded steel and bolted aluminum four - post frame Equipment mounting rails, two pairs Grounding/bonding system and ground lug Leveling feet and casters Floor attachment brackets Baying kit, for 600mm or 24 spacing PDU brackets, one pair, for mounting two vertical PDUs Equipment mounting hardware, (50) M6 cage nuts and screws See Height, Width and Depth tables under Ordering Information/Dimensions 3000 lb (1360 kg), static load on leveling feet 2250 lb (1020 kg), rolling load on casters 2000 lb (907.2 kg), shipping on shock pallet 2500 lb (1134 kg), static load on leveling feet 2000 lb (907.2 kg), rolling load on casters EIA-310-E compliant UL Listed 2416, NWIN Steel frame, rails and panels Aluminum slides Plastic grommets/seals Epoxy-polyester hybrid powder coat paint on frame, rails, panels in Black or Glacier White Grommets/seals, door handles/hinges are black For indoor use only, in environmentally controlled areas, not harsh environments Welded/bolted frame Mounting rails bolt to frame Perforated front door Choice of solid or double perforated rear door Perforated area is 78% open Solid door includes a perimeter seal Front door opens to 120 when bayed, 145 when not bayed Rear door opens to 180 when bayed or not bayed Hinge pins allow easy removal during maintenance Reversible to open from the right or left, must move hinges/latch Interchangeable front or rear, must move hinges/latch Swing handle with keyed lock Two pairs of mounting rails in the cabinet Adjustable depth, rails slide front-to-back, marks on frame for easy vertical alignment 1-3/4 H (44.45 mm) U spacing, marked and numbered on all rails 19 W, EIA-310-E Universal 5/8-5/8-1/2 (15.9 mm 15.9 mm 12.7 mm) vertical hole spacing Mounting rails, top panel, side panels and doors are electrically bonded to the cabinet frame Prepared location for ground lug at the top and bottom of the cabinet frame A grounding lug is included to attach the frame to ground Heights: 42U - 52U (Above 52U is a custom option) Widths: 600mm (23.6 in) to 800mm (31.5 in) Depths (without Doors): 800mm (31.5 in) to 1200 (47.2 in) Depths (with Doors): 900mm (35.4 in) to 1300 (51.2 in)
Our experienced Sales and Engineering Team will work with you to develop a flexible engineered solution for your current applications, challenges and future requirements. DIMENSION DRAWINGS DIMENSION TABLES (Other sizes available) TOP VIEW Height Dimensions - in (mm) RACK MOUNT SPACES (U) OVERALL WITH CASTERS FRAME ONLY NO CASTERS FRONT OPENING 42 79.4 (2016) 77.4 (1965) 73.9 (1876) 45 84.6 (2149) 82.6 (2099) 79.1 (2010) 48 89.9 (2282) 87.9 (2232) 84.4 (2143) 52 96.9 (2460) 94.9 (2410) 91.4 (2321) Casters add approximately 2 (51 mm) to frame and are factory installed on the cabinet. NOMINAL WIDTH Width Dimensions - in (mm) OVERALL WITH SIDE PANELS FRONT OPENING RACK-MOUNT PANEL WIDTH FRONT VIEW SIDE VIEW 600 23.6 (600) 19.6 (498) 19 (482.6) 700 27.6 (700) 23.5 (598) 19 (482.6) 750 29.5 (750) 25.5 (648) 19 (482.6) 800 31.5 (800) 27.5 (698) 19 (482.6) Mounting Rail clearance is 17.8 (452 mm), mounting hole spacing is 18.3 (465 mm). NOMINAL DEPTH Depth Dimensions - in (mm) OVERALL WITH DOORS FRAME ONLY NO DOORS MAXIMUM RAIL DEPTH 800 35.4 (900) 19.6 (498) 19 (482.6) 1000 43.3 (1100) 23.5 (598) 19 (482.6) 1050 45.3 (1150) 25.5 (648) 19 (482.6) Overall Height (includes casters) Frame Opening Rail Height (U) Panel Width Frame Opening Max. Rail Depth 1100 47.3 (1200) 43.3 (1100) 41.1 (1045) 1200 51.2 (1300) 47.2 (1200) 45.1 (1145) Front Door is approximately 2.4 D (61 mm), and Rear Door is approximately 1.5 D (38 mm) with hinges/latches. Minimum rail depth is 7 (178 mm), each rail is 3.5 D (89 mm). Rail depth is reduced when vertical accessories are placed in corners. Overall Width Frame Depth Overall Overall Depth 05 05
PRE-INSTALLED CABLE MANAGEMENT ACCESSORIES Our fully-welded frames and wide selection of accessories offer an aesthetically pleasing, high level customization enclosure with features integrated into the design assuring built in cable management. Our process gives you extreme flexibility in product creation, pre-installation and the unique ability to customize. FINGER CABLE MANAGERS Attaches to the equipment mounting rail creating a pathway for cables next to the rail, and includes plastic T-shaped cable guides (fingers) that organize cables by U. Two depths are available. RING CABLE MANAGERS Is independent of the equipment mounting rails creating a separate vertical pathway for cables and includes plastic cable rings to organize cables. CABLE LASHING BRACKETS Creates a simple, separate vertical pathway for a small bundle of cables and has multiple slots for straps or tie wraps to secure cables to the bracket. Full Height Dual PDU Bracket supports two vertical PDUs sidebyside and has multiple slots for straps or tie wraps to secure cords to the bracket. 06
PRE-INSTALLED POWER DISTRIBUTION APPLICATION BASIC METERED MONITORED MONITORED PRO SWITCHED SWITCHED PRO 6 Functionality Levels delivering safe & efficient power distribution to critical applications For high-density data center and equipment rooms that require reliable power distribution when no power monitoring is required. For high-density environments where networking of PDUs is not allowed. Metering functionality provides input current readings for accurate load balancing. For the remote power monitoring of PDUs. Ideal for use in data centers and equipment rooms where monitoring of power at the breaker/pdu level is important for availability purposes. For the remote power monitoring of PDUs and outlets. Ideal for use in data centers and equipment rooms where monitoring of power to individual IT equipment is important for power charge back reports. For the remote on/off power control of outlets and monitoring of PDUs. Ideal for use in lights out data centers For the remote on/ off power control and monitoring of PDUs and outlets. A complete power solution for colocation facilities, data centers and equipment rooms. CAPABLIITIES BASIC METERED MONITORED MONITORED PRO SWITCHED SWITCHED PRO Basic Power distribution ü ü ü ü ü ü Local Display NONE LED LCD LCD LCD LCD High ambient temperature ratings up to 149 f (65 c) ü ü ü ü ü ü Locking Outlets options available ü ü ü ü ü ü Complimentary Preinstallation in AFL Hyperscale Enclosure Systems ü ü ü ü ü ü UL/CE Listed ü ü ü ü ü ü Input Metering ü ü ü ü ü Remote Management ü ü ü ü Branch circuit level Metering ü ü ü ü IP Consolidation Utilizing Secure Array Technology ü ü ü ü Integrated Environmental Monitoring ü ü ü ü Integrated Access Control ü ü ü ü Outlet Level Metering ü ü Outlet Grouping and Naming ü ü Remote outlet switching with local, LED on/off ü ü 07
USA USA (WEST COAST) 8039 S. 192nd Street, Suite 100 Kent, WA 98032, USA +1 866 814 8615 usasales@aflhyperscale.com USA (EAST COAST) 260 Parkway East, Duncan, SC 29334, USA +1 800 790 9932 usasales@aflhyperscale.com EMEA UK Davy Avenue, Knowlhill, Milton Keynes, Buckinghamshire, MK5 8HJ, UK +44 (0) 1908 441 144 emeasales@aflhyperscale.com UAE Main Office 1601, Room 1602, 48 Burj Gate, Sheikh Zayed Road, PO Box 378978, Dubai, UAE +971 4404 9606 mesales@aflhyperscale.com APAC CHINA 7D, Block A, Hongsong Building, Tairan 6th Road Futian, Shenzhen, China, 518000A +86 755 2561 3694 INDIA Plot No 38-A1, First Floor, Doddanekundi Industrial Area, II Phase, Mahadevapura Post, Bangalore 560048 +91 804 687 4687 indiasales@aflhyperscale.com HONG KONG 7/F, Bonham Circus, 40 Bonham Strand, Sheung Wan, Hong Kong Copyright AFL Hyperscale 2018 All Rights Reserved E&OE AFLHSHYPERFRAMECAB V1 +852 3689 6396 apacsales@aflhyperscale.com