Lightning and Surge Arresters

Similar documents
Lightning and Surge Arresters

Overvoltage Protection Devices

Overvoltage Protection Devices

Overvoltage Protection Devices

Overvoltage Protection Devices

Overvoltage Protection Devices

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

Surge Protection Devices Ex9UE2

R3&A Limited, Cobourg, ON

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

6/2 Product overview. 6/3 Lightning arresters, type 1. 6/5 Combination surge arresters, type 1 and type 2. 6/7 Surge arresters, type 2

wietap wietap Overvoltage Protection Tensions running high

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

BETA Protecting Overvoltage Protection Devices

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

3 Design of the electrical installation protection system

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

Coordinated Surge Protection

PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION

Surge Protection Devices Type 1+2

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

Increased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Surge Protection Devices and Surge Protection Kit

Switch Disconnectors, Main and EMERGENCY-STOP Switches

SPM Series Plug-in Surge Protection

ETITEC - Lightning and Surge Arresters

Overvoltage Protection for low-voltage supplies

2 Principle of lightning protection

SPM Series. Plug-in Surge Protection

Overvoltage Protection

Application-optimised DEHNshield Combined Arrester

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

Surge protection for gutter heating systems

Surge protection for LED mast lights

Surge protection for frequency converters

NEW surge protective devices

The Wave Breaking Factor and it s Vital Role in Surge Protection Device Coordination. Hans Slagter, DEHN + SOHNE

Page 14-4 Page Page 14-4 SURGE PROTECTION DEVICES TYPE 2 VERSIONS WITH PLUG-IN CARTRIDGE 1P, 1P+N, 2P, 3P, 3P+N, 4P

voltage surge protectors low voltage type 1 (class I / B) voltage surge protectors low voltage type 2 (class II / C) Distribution board protection

Surge Protection for Surveillance Systems

Surge Protective Device

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

PT 3-PB-ST. Extract from the online catalog. Order No.:

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

US Catalog July 2016 SMISSLINE TP

US Catalog March Surge protective devices (SPDs) UL range

Surge Protection. Surge Protection

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

Lightning Current Equipotential Bonding SPDs

Deploying surge protective devices (SPDs) in photovoltaic systems. Technical Information

Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE. Surge Protection Device

Lightning and surge protection for electromobility

SURGE PROTECTION LIGHTNING & EARTHING EQUIPMENT

Product and functional description

Product and functional description

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

ENGR. MARITES R. PANGILINAN, P.E.E.

/60 ETITEC A 15/ /60 ETITEC A 15/440 Al/Fe connection*

VAL-CP-1S-175. Extract from the online catalog. Order No.:

Safety wherever needed

VAL-CP-3S-350. Extract from the online catalog. Order No.:

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

POWER SUPPLY SYSTEMS SPDs for low-voltage installations and equipment

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

Miniature Circuit Breakers for Railway Applications

STEP-PS/1AC/24DC/1.75

Residual Current Devices drcm Digital

Minia. Application manual Overvoltage protections

Type 1 Arresters. Use in installations with short-circuit currents up to 100 ka rms DEHN + SÖHNE / protected by ISO 16016

Type Code No. Weight Packaging [g] [pcs]

interface Overvoltage Protection

onlinecomponents.com Overvoltage protection Contents Overvoltage protection Overvoltage protection F.1

MINI-PS AC/10-15DC/8

Type of surge arrester

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

Surface-Mounting Product Ranges

Surge & Filter Protection Addressing your industrial power quality needs.

BS th Edition wiring regulations Furse overview

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

QUINT-PS/ 1AC/24DC/ 5

MCF lightning arrestor

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

LPI SG + SS480 Spark Gap Surge Filters

Surge Protective Device

When the voltage rises... The new V20/V50 arrestor series

Lightning and Surge Protection for PV Systems

OPTIMISED LUMINAIRE PROTECTION

mcbs, EQUIPMENT NEW PRODUCTS 2014 Voltage surge protectors & other control and signalling devices Time & light sensitive switches

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

Transcription:

Lightning and Surge Arresters 5/4 Product overview 5/5 Lightning arresters, requirement category I (B) 5/6 Combined arresters, requirement category I (B) and II (C) 5/7 Single-pole surge arrester, requirement category II (C) 5/9 Multi-pole surge arrester, requirement category II (C) 4 5 5/0 Surge arrester, requirement category III (D) 5/ Accessories 5/

Protected in a flash: Lightning current, overvoltage and device protection Every year there are around one million lightning strikes it's a risk you are well advised to avoid. Surge arresters offer reliable protection against overvoltage from the incoming supply through to the outlet. Even sensitive equipment is thus protected from damage. 5/2

Stay cool. 5 BETA lightning current, overvoltage and device protection 5/3

Program overview Q Overview Lightning arrester requirement category I (B) Combined arrester requirement category I (B) and II (C) Surge arrester requirement category II (C) Surge arrester requirement category III (D) Accessories 5/4 Siemens ET B 2005

Overview Supports inclusion of power lines in the lightning protection equipotential bonding For protection of low-voltage load systems against overvoltage, even in the case of direct lightning strikes Max. permissible operational voltage 255 V AC, 50/60 Hz Lightning impulse current test, wave-shaped 0/350 s Selection and ordering data Lightning arresters, requirement category I (B) The enclosed version can prevent ion emissions, as opposed to self-extinguishing measuring spark gaps: this facilitates the mounting of wiring next to other devices in the system. Supports energy coordination with surge arresters of requirement category II. 5 mm mounting depth 2 3 Lightning arresters 5SD7 3- Lightning arrester, -pole Discharge capacity MW Order No. Price PG Weight PS*/ item P.unit item kg Items unenclosed 75 ka 2 5SD7 3-0 0.353 N-PE unenclosed 00 ka 2 5SD7 3-0 0.295 enclosed 50 ka 2 5SD7 3-0.262 N-PE enclosed 00 ka 2 5SD7 3-0.26 Lightning arrester, 3-pole enclosed 00 ka 4 5SD7 33-0.620 Lightning arrester with increased follow current quenching capability, -pole safe disconnection of line-follow currents up to 50 ka eff without back-up fuse unenclosed 50 ka 2 5SD7 35-0 0.305 Accessories for 5SD7 3-0, 5SD7 3-0 and 5SD7 35-0 to ensure the required mounting dimensions: Molded plastic distribution system HP in box size and 2, see catalog LV 30. 5 6 7 9 0 2 3 Siemens ET B 2005 5/5

Combined arresters, requirement category I (B) und II (C) Q Overview Combined arresters are surge arresters that meet the basic requirement of requirement category I and II, i.e.: - have a lightning stroke current discharge capacity of 75 ka/00 ka (0/350 s) - can be energy-coordinated with surge arresters of Class II and III, as well as directly with data terminal equipment of overvoltage category l (Un = 230 V AC) Protection level <.5 kv, corresponding to withstand impulse voltage of overvoltage category I Compact unit for all three-phase systems which is ready for connection Connection system: double terminal design supports "V wiring" option Multifunction terminal in the outgoing circuit Visual operational voltage display Remote signaling using separate, overvoltage-protected display and remote signaling module Overvoltage and atmospheric lightning arrester in a single device Perfect "all in one" solution Cabled complete device for any distribution system (TT, TN-C and TN-S) Easy-to-use device selection thanks to simple description Up to 70 % more space saving than conventional solutions Simple installation on mounting rail 5 mm mounting depth Q Selection and ordering data MW Order No. Price PG item Weight item PS*/ P.unit kg Items Combination arrester TN-C 6 5SD7 343-0.070 TN-S 5SD7 344-0.3 TT 5SD7 343-.402 2P TT 5SD7 34-0.32 for combined arrester 5SD7 343-0, 5SD7 343- and 5SD7 344-0 with 4 connecting cables.5 5SD7 34-3 0.46 for combined arrester 5SD7 34- with 2 connecting cables 5SD7 34-0.3 5SD7 343- For technical data please refer to catalog ET B T 2005. 5SD7 34-3 The remote signaling module is placed on left-hand side of combined arrester and linked to the existing connecting cables. Contact: changeover 250 V AC, 0.5 A 250 V DC, 0. A 25 V DC, 0.2 A 75 V DC, 0.5 A Contact /2: Operating status /4: Fault scenario Remote signaling module 4 2.5 For technical data see catalog ET B T 2005. 5/6 Siemens ET B 2005

Overview For the protection of low-voltage load system against overvoltage High discharge capacity through powerful zinc oxide varistors/ spark gaps (N-PE surge arresters) High monitoring reliability through isolating arrester disconnector, type "Thermo Dynamic Control" with double monitoring Fault indication through red marking in inspection window Multi-function terminal for conductor and busbar connection Simple replacement of surge arrester connectors Single-pole surge arrester, requirement category II (C) Simple mounting on mounting rail with busbars Design as for multi-pole version Same connector as for multi-pole version No interaction limiting phase reactor with surge arrester Class III (formerly D) 2 3 Selection and ordering data MW Order No. Price PG Weight PS*/ item P.unit item kg Items Surge arrester, -pole Complies with E DIN VDE 0675, Part 6/.9 and Part 6/A/03.96 and Part 6/A2/0.96 Surge arresters High monitoring reliability through isolating arrester disconnector, type "Thermo Dynamic Control" with double monitoring function Fault indication by red marking in the inspection window Multifunction terminal for conductor and busbar connection -pole Surge arrester rated voltage U c = 275 V 5SD7 300-2 0.25 Surge arrester rated voltage U c = 35 V 5SD7 300-5 0.33 Surge arrester with remote display ) Design as for 5SD7 300-2, but with additional 3-pole terminal for connection of remote indication When the monitoring device responds (disconnection of the defective arrester from the line supply as a result of overload) the remote signaling connections are switched by means of a floating changeover contact. -pole Surge arrester rated voltage U c = 275 V 5SD7 30-2 0.32 5 6 7 9 0 2 3 Siemens ET B 2005 5/7

Single-pole surge arrester, requirement category II (C) Q Selection and ordering data MW Order No. Price PG item Weight item PS*/ P.unit kg Items Surge arrester, -pole, plug-in Plug-in surge arrester Design as 5SD7 300-2, but 2-piece, comprising basic element and plugged protective block -pole Surge arrester rated voltage Uc = 275 V Surge arrester rated voltage Uc = 335 V 5SD7 302-2 5SD7 302-4 0.34 0.34 5SD7 303-2 5SD7 303-4 5SD7 303-5 0.3 0.3 0.37 5SD7 30-0 0.7 5SD7 302-2 Plug-in surge arrester with remote display ) Design as 5SD7 302-2, but with additional 3-pole terminal for connection of remote indication When the monitoring device responds (disconnection of the defective arrester from the line supply as a result of overload) the remote signaling connections are switched by means of a floating changeover contact. 4 2 5SD7 303-2 Surge arrester rated voltage Uc = 275 V Surge arrester rated voltage Uc = 335 V Surge arrester rated voltage Uc = 35 V N-PE surge arrester for 3+ circuitry in the TT system Specially for use in TT system in "3+ circuit" according to DIN V VDE V 000-534: 999-04 between neutral wire N and PE conductor PE/equipotential bonding with lightning impulse current (0/350 s) 2 ka Surge arrester on the basis of spark gaps Multifunction terminal for conductor and busbar connection Surge arrester rated voltage Uc = 275 V For technical data see catalog ET B T 2005. ) The devices can be coupled to instabus KNX/EIB and AS-i bus or PROFIBUS through potential-free changeover contacts. in p u t I2 _ 0 7 6 6 2 a in s ta b u s K N X /E IB 5/ Siemens ET B 2005

Overview Design as surge arrester, but with additional 3-pole terminal for connecting remote indication. When the monitoring device responds (disconnection of the defective arrester from the line supply as a result of overload), the remote signaling terminals are switched by means of a floating changeover contact. Easy installation of the remote indication due to the plug-in terminal. Designs: TN-C, plug-in TN-C, plug-in with remote indication TN-S, plug-in TN-S, plug-in with remote indication TT plug-in type TT plug-in type with remote indication All device models are available for surge arrester rated voltages of 275 V, 335 V and 35 V (siehe Seite 5/9). Accessories: connector Models suitable for multi-pole surge arresters TN-C/TN-S/TT and single-pole surge arresters. The pluggable protective block can be replaced without the need to disconnect the supply voltage or remove the cover plate of the distribution board. Selection and ordering data Surge arrester, multi-pole, plug-in 5SD7 327-2 5SD7 32-2 Multi-pole surge arrester, requirement category II (C) Benefits Pre-wired complete units for conventional system types (TN-C, TN-S, TT), comprising a basic part and plug-in protective blocks High discharge capacity through powerful zinc oxide varistors or spark gaps for TT surge arresters High monitoring reliability through isolating arrester disconnector, type "Thermo Dynamic Control" with double monitoring Fault indication by red marking in the inspection window Multifunction terminals for conductor and busbar connection Simple replacement of surge arrester connectors Up to 70 % more space saving than conventional solutions Simple mounting on mounting rail with busbars Design as for -pole version No interaction limiting phase reactor with surge arresters Class III (corresp. D) Same male connectors as for -pole version Surge arrester rated voltage MW Order No. Price PG Weight PS*/ item P.unit U c item kg Items TN-C 275 V 3 5SD7 323-2 0.377 335 V 3 5SD7 323-4 0.377 35 V 3 5SD7 323-5 0.377 TN-C with remote indication 275 V 3 5SD7 324-2 0.4 335 V 3 5SD7 324-4 0.4 35 V 3 5SD7 324-5 0.369 TN-S 275 V 4 5SD7 325-2 0.45 335 V 4 5SD7 325-4 0.45 35 V 4 5SD7 325-5 0.43 TN-S with remote indication 275 V 4 5SD7 326-2 0.46 335 V 4 5SD7 326-4 0.46 35 V 4 5SD7 326-5 0.46 TT 275 V 4 5SD7 327-2 0.42 335 V 4 5SD7 327-4 0.42 35 V 4 5SD7 327-5 0.42 TT with remote indication 275 V 4 5SD7 32-2 0.50 335 V 4 5SD7 32-4 0.50 35 V 4 5SD7 32-5 0.50 2 3 5 6 7 9 0 2 3 Siemens ET B 2005 5/9

Surge arrester, requirement category III (D) Q Benefits For the protection of electronic device against overvoltages (overvoltage category II according to DIN VDE 00-:997-04) Surge arrester of requirement category D according to E DIN VDE 0675, Part 6/.9 and 6/A: 996-03 SPD Type 3 according to EN 6643-: 200 SPD class III according to IEC 6643-: 99-2 Optical function indication (green) Optical fault indication (red) 5 mm mounting depth Q Selection and ordering data MW Order No. Price PG item Weight item PS*/ P.unit kg Items Surge arresters Complies with E DIN VDE 0675, Part 6: 99- and -6/A: 996-03 Surge arrester, 2-pole 2-pole overvoltage protection with monitoring equipment and isolating arrester disconnector Floating communication contact (NC contact) for fault indication (no system shutdown) Rated voltage UN = 230 V Surge arrester rated voltage Uc = 255 V.5 5SD7 332-0 0.30 3 5SD7 334-0 0.30 5SD7 335-0 0.59 5SD7 335-0.20 Surge arrester, 4-pole 4-pole overvoltage protection with monitoring equipment and isolating arrester disconnector Optical function indication for 3 outer conductors (glow lamp green) Floating communication contact (NC contact) for fault indication (no system shutdown) Rated voltage UN = 230 V/400 V Surge arrester rated voltage Uc = 255 V/440 V Surge arrester (outlet devices) Complies with E DIN VDE 0675, Part 6: 99- and -6/A: 996-03 Siemens 5 outlet with overvoltage protection 5UB.../5UH...) With labeling field and function indications For the DELTA switch-outlet range Protective adapter Outlet adapter to protect electronic devices Can be plugged into 5 outlets With optical function indication/monitoring Rated current: 6 A Rated voltage: 230 V/50 Hz Nominal discharge current 2.5 ka Protective adapter with line filter Like 5SD7 335-0 protective adapter, but with additional line filter against high-frequency noise voltages Rated current: 4 A For technical data see catalog ET B T 2005. ) For prices and additional information, see the ET D catalog, "DELTA switches and outlets". 5/0 Siemens ET B 2005

Selection and ordering data 5SD7 392-2 Busbar Accessories MW Order No. Price PG Weight PS*/ item P.unit item kg Items Through-type terminal For simple wiring in the different circuit versions (see section, "Configuring aid") -pole 5SD7 360-0 0.20 Male connector for surge arresters Male connectors can be used for both single-pole and multipole surge arresters Male connector for L-N surge arrester Surge arrester rated voltage U c = 275 V 5SD7 392-2 0.049 Male connector for L-N surge arrester Surge arrester rated voltage U c = 335 V 5SD7 392-4 0.049 Male connector for L-N surge arrester Surge arrester rated voltage U c = 35 V 5SD7 392-5 0.049 Male connector for N-PE surge arrester (TT system) 5SD7 39-0 0.033 Busbar for lightning arrester -pole, single-phase 5SD7 36-0.039 Busbar for surge arrester 4-pole, single-phase 5SD7 36-0 0.020 Busbar for combined arrester TN-S/TT and 4-pole FI protective devices (5SM and 5SM3) 5SD7 04 0.33 Busbar for combined arrester TN-S/TT and 4-pole miniature circuit-breakers (5SY) 5SD7 05 0.43 Busbar for combined arrester TN-C and 3-pole FI protective devices (5SM and 5SM3) 5SD7 06 0.079 Busbar for combined arrester TN-C and 3-pole miniature circuit-breakers (5SY) 5SD7 07 0.04 Busbar for multi-pole surge arrester TN-S/TT and 4-pole miniature circuit-breakers (5SY) 5SD7 0 0.04 2 3 5 6 7 9 0 5SD7 390-0 Busbar for multi-pole surge arrester TN-C and 3-pole miniature circuit-breakers (5SY) 5SD7 090 0.064 Decoupling reactor For the energetic coordination of lightning and surge arresters in the event of a lightning impulse current of 0/350 s The concentrated inductance replaces the otherwise necessary cable length for decoupling lightning and surge arrester 5 mm mounting depth Rated voltage: 500 V, 50 Hz... 60 Hz Inductance: 5 H 20 % Rated current: 35 A 2 5SD7 390-0 0.355 Rated current: 63 A 4 5SD7 39-0 0.70 2 3 Siemens ET B 2005 5/

Notes 7 5/2 Siemens ET B 2005