XSP / XSR DMX Splitter / RDM Hub. User Manual

Similar documents
XSW DMX Splitter / Booster, Wireless DMX Transmitter & Wireless DMX Receiver. User Manual

X-MG-51. DMX Merger User Manual

ISP Installation Splitter User Manual

DMX512-A 2.10 HUB. User Guide

DMX512-A 1.5 HUB. User Guide

USER MANUAL Table of Contents

XPD-28 2:8 DMX & RDM Splitter User Manual

LED SPIDER MOVING HEAD LIGHT

USER MANUAL Table of Contents

ZEPHYR Compact Haze Machine

Please read the instructions carefully before use LED PYRAMID LED-904D. Innovation, Quality, Performance 15-

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

Page 1 of 6 FXLD1218FRP5I LED FIXTURE Version 0.1 OWNERS MANUAL 08/01/2016

DMX Tool Splitter 1 to 5 User Manual

MATRIX LED LED User Manual Please read the instructions carefully before use

Blue Weapon Laser. User manual UK. Version 1.0

1 Channel Strobe Controller ORDERCODE 40226

Split2.8 RDM. 2 input DMX/RDM Splitter. User guide

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

Eternal Lighting. Premier150 Spot. User Manual

A double yoke enables the fixture to be operated in several positions.

Page 1 of 6 FXLD157FRP6I2 LED FIXTURE Version 0.2 OWNERS MANUAL 3/31/2017

User Manual Please read the instructions carefully before use

Light Brick ORDERCODE 50370

Spectrum Laser. User manual UK. Version 1.0

PX165. DMX Splitter INSTRUCTION MANUAL

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

LED Slimline PAR RGBW 7x8W

DarkFX Spot 670 User Manual English

LED PAR56 Order Code: P56-151

TB-1230 QW. User Manual Please read the instruc on carefully before use

LED W RGBA User Manual

Model DMX24DIM Installation and Operations Manual

Cluster FX-Bar. Portable performance lighting and laser rig

STAGE TRI-PAR 18TC CP-18TC. User Manual. Please read the instructions carefully before use

Models DMX12DIM ELV Installation and Operations Manual

LIGHT BRICK - 12 X 3W TRI-COLOUR

WDMX Wireless DMX Transmitter & Receiver. User s instruction manual

D-Pack 6 Classic ORDERCODE 50315

ETC Installation Guide

LED BEAM 300 LED-MB50. User. Guide. Professional Entertainment Technology

Professional Entertainment Technology LED BEAM 300 LED-MB50. Innovation, Quality, Performance 23-

Professional Entertainment Technology LED BEAM 300 LED-MB50. User. Guide

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

DSI-4. DMX Optically Isolated 1x4 Splitter. D Series. DSI_4 Users Manual r3.lwp copyright 2009, 2010, 2011 ELM V. T. Inc.

L1.2 & L2.2. LED Studio Light OPERATING INSTRUCTIONS

UV Power Flood. User Manual. Order code: EQLED029

CS2 DMX Distribution Splitter

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

OPERATING MANUAL. DMX Booster/Splitter 3404C-H RDM Mk6

User Guide. Please read these instructions carefully before use

DCS Infrared Transmitter. User Manual. Digital Conference System. Danish Interpretation Systems

GigaSwitch 8. User Guide

Gobo Projector XP 80W

HX1 Bluetooth Stereo Headset

LED Giga Bar 4. User Manual

FLEX BEAM V8. User Manual Please read the instruction carefully before use

MONOPRICE. ShowPony 12-Watt LED Derby FX Light (RGBW) User's Manual P/N

ALO Duo Roll DMX LED barrel scanner with dual light source

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

PROFESSIONAL SHOW LIGHT

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

Широкий ассортимент оборудования ACME на User Guide. Professional Entertainment Technology

Fog machine PT Users Manual

Blitzer Strobe. User Manual. Order code: EQLED366

CP 64 BD15 CP 64 PD15

Artistic Licence. Rail-Split RDM. User Guide. Serial nos and upwards. Rail-Split RDM User Guide. Version 5-0

Octostrip ORDERCODE 42220

User s manual. Easy Scan XT3 LED

LED Par 64 Short DMX ORDERCODE 42431

Check that the unit has not been damaged during transport

Magnum Club Smoke System

Kam StarWash Multicolour wash effects with green & red star cluster laser

Snapshot. Data Stream 4 USER MANUAL

Crossfire. User Manual. Order code: EQLED061

3D OBJECTS RGB LASER. Order ref: UK User Manual

RGB Power Batten. User Manual. Order code: EQLED032

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

Artistic Licence. Rail-Demux. User Guide. Rail-Demux User Guide. Version 2-7

Artistic Licence. Rail-Split extreme. User Guide. Serial numbers 151 upwards. Rail-Split extreme User Guide. Version 5-0

Promopar ORDERCODE 30120

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

TourPro RGBAW Stagebar USER MANUAL

imove 50SR LED-MS50A User Guide Professional Entertainment Technology

ITA100 MKII 100mW green DMX laser

Microbar COB System. User Manual. Order code: EQLED137

UV Spectra Batten 12 x 5W UV LEDs

N-E Color Par 64 USER MANUAL

User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch

USER MANUAL SES-FA4BAL

i.shine 1136 RGBW Color Stainer CN USER MANUAL

Z-380 Fazer Machine User Manual English

MX3 BT LED Party Tube

OPERATING MANUAL. DMX Booster/Splitter 3404C-H RDM Mk2

MICRON DJ Booth Tri-colour Starcloth

12X3W UV LEDS PROJECTOR LED- 12 USER GUIDE

7x15W 4IN1 Infinity Rotation LED Pixel Bar. This product manual contains important information about the safe

* * Agilent Power Distribution Unit (PDU) Installation Guide

Order code: EQLED53 User manual

Transcription:

XSP / XSR DMX Splitter & RDM Hub User Manual XSP / XSR DMX Splitter / RDM Hub User Manual Issue 4 (2010-06-15) Copyright 2010 SWISSON AG No part of this documentation may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, without the prior written permission of SWISSON AG. The information in this documentation is supplied without warranty of any kind, either directly or indirectly, and is subject to change without prior written notice. SWISSON its employees or appointed representatives will not be held responsible for any damages to software, hardware, or data, arising as a direct or indirect result of the product(s) mentioned herein. Dieses Dokument darf weder vollständig noch auszugsweise in irgendwelcher Form reproduziert, kopiert oder gespeichert werden, ohne das vorherige schriftliche Einverständnis der Firma SWISSON AG. Die Informationen in diesem Dokument sind ohne jegliche Gewähr und können ohne vorherige Ankündigung jederzeit im Sinne des technischen Fortschritts geändert werden. SWISSON und seine Angestellten oder seine Vertreter sind nicht verantwortlich für Schäden, welche direkt oder indirekt mit den in diesem Dokument beschriebenen Geräten entstanden sind. Issued by SWISSON AG SWISSON of AMERICA Corp. Fabrikstrasse 21 2419 East Harbor Blvd. #34 CH-3250 Lyss Ventura, CA 93001 Switzerland U.S.A. E-Mail: welcome@swisson.com

XSR and XSP DMX Splitter/Booster & RDM Hub Introduction The XSR and XSP series of RDM hubs and DMX splitter/boosters, from SWISSON can be easily and economically integrated into any lighting system where you wish to spilt and boost DMX and RDM signals. While the XSP spiltts and boost only DMX signals, the XSR also detect RDM Data and use its bidirectional functionality to report back to the Controller (Lighting Board). All output ports on both XSP and XSR are optically isolated. A strong power supply allows a reliable operation in a wide voltage range. A large program of XSR and XSP devices is available; consisting of different housings, different connector types and different numbers of input and output ports. Applications Concert Lighting Live Events Multimedia Shows Theater Typical Application TV Sets Theme Parks Achitectural Lighting DMX Light Board with or without RDM functionality DMX Fixtures with or without RDM functionality DMX Dimmers with or without RDM functionality The XSR works within DMX / RDM environments and works as well as in pure DMX environments. The XSR is a good solution for those who expect to use RDM in future because the XSR acts as a normal DMX splitter if there is no RDM Data. The XSP work only within DMX evironments. 2

Benefits using a XSP/XSR Splitter / Booster Boost On installations with excessively long cable runs the DMX and/or RDM signal can be compromised or significantly weakened by the distance. Good signal Weak signal bad signal The XSP/XSR boosts the signals thus eliminating signal interference Good signal Weak signal Good signal Regenerate In harsh environments DMX and RDM signals can be disturbed or corrupted. Good signal Disturbed signal bad signal disturbance disturbance The XSP/XSR cleans and regenerates the signals. Good signal Disturbed signal Good signal disturbance 3

Split A simple split of signal lines is not allowed. The bidirectional operation of RDM is even more sensitive to the split on that than DMX. not allowed A split of the signal lines is possible with the XSR / XSP by using different output ports Reduces reflection problems Signal reflection is a common problem on large DMX installations or on long signal lines. The bidirectional operation of RDM is more sensitive to reflections than DMX. Weak reflection with large delay. Signal OK Strong reflection with large delay. Bad signal! Strong reflection with small delay. Signal OK The XSP/XSR split the line into smaller segments with a regenerated signal, which reduces the delay of the reflection on each segment. Reflection with small delay. Signal OK Reflection with small delay. Signal OK 4

Protect In case of an over voltage on the DMX and RDM line(s), all devices on that line can be damaged. The XSP/XSR separate the line into multiple segments. The over voltage is restricted to the concerned segment. The XSP/XSR itself is well protected against transient over voltage and the optical isolation of each port prevents a damage of other ports and segments in case of a permanent over voltage. XSP Block Diagram Control Logic Receiver Line Termination Transmitter Transmitter Transmitter Transmitter Transmitter In Port Thru Port Termination Out Port 1 Out Port 2 Out Port 3 Out Port 4 Out Port 5 5

XSR Block Diagram Control Logic Teanceiver Line Termination Tranceiver Tranceiver Tranceiver Tranceiver Tranceiver In Port Thru Port Termination DMX Only Out Port 1 Out Port 2 Out Port 3 Out Port 4 Out Port 5 Mains Connection Two different Mains connections are available: The US versions are delivered by Swisson with a "Edison Plug" (NEMA-5-15). These models has a "-US" suffix at the end The International versions are delivered without any plug. Swisson distributors or dealers may deliver the devices with a country specific plug. Yellow/Green : Earth Brown : Phase Blue : Neutral US Versions (-US suffix) International Versions Input Section XSP Versions The Input section of the versions with XLR connectors 6

The Input section of the versions with terminals: The input and thru terminals are at the rear of the device. The Power LED shows if the device powered and if power supply unit of the XSP is working A green LED shows if a signal is available at the Input port. A red LED shows if the received signal is faulty The XSP has a built in line termination. This can be activatet by pressing the termination button. A LED shows if the termination is activated. Input Section XSR Versions The Input section of the XSR versions with XLR connectors The Input section of the XSR versions with terminals: The input and thru terminals are at the rear of the device. The Power LED shows if the device powered and if the power supply unit of the XSR is working A multicolor LED shows if a signal is available at the Input port. The LED has 3 different states: Off: No signal present Green: Signal is present and Ok Red: Signal is present but faulty 7

The RDM LED show if RDM data packets are preset. In a pure DMX environment this LED remains off. The XSR has a built in line termination. This can be activatet by pressing the termination button. A LED shows if the termination is activated. The "dmx only" function of the XSR allows removal off all RDM data from the outupt ports. A LED shows if the "dmx only" function is activated. Input and Thru Port The THRU port is hardwired with the INPUT port and allows to daisy-chain the devices even when the XSR is not powered. On all XSP and XSR models with 5- Pin XLR connector the pin 4 and 5 are also looped thru to the THRU port. On all other models pin 4 & 5 are not available. Line Termination Teanceiver Input Port 1 2 3 4 5 Thru Port 1 2 3 4 5 Line Termination All XSP and XSR splitters have a built-in line termination. The termination is activated by pressing the termination button. On terminal and Installation version the button is only accessible with a tool (such as a paper clip). 8

DMX Only (only on XSR models) The "DMX only" function removes all non DMX data before forwarding the data to the output ports. RDM data will be removed too. This can be helpfull when DMX devices are not compatible and do not check the data they receive as valid DMX. The "DMX only" function is activated by pressing the "DMX only" button. On terminal and Installation version the button is only accessible with a tool. Output Ports The output section of the versions with XLR connectors: The OUTPUT section of the versions with terminals: The OUTPUT terminals are at the rear of the devices. Each output port is individually optically isolated, meaning that it is totally isolated from the other output ports and the input selection. The Pins 4&5 on the models with 5-Pin XLR connectors are not connected. Controller Supply Port Supply Output Port Control Logic Tranceiver Bias Network n.c. 1 2 3 4 5 On the XSR the signal LED of the OUTPUT ports show if a valid signal is transmitted. It works bidirectionally: When sending DMX or RDM packets and when receiveing RDM responces. This LED is not available on the XSP models. 9

XSP / XSR Box Models 45mm 217.5mm 112mm Mains cable Mains plug (US-Versions only) cable length approx. 145cm M10 female threat for clamp Eye for savety wire The length of the M10 screw which enters the XSP/XSR should not exceed a maximum of 20mm. 20mm MAX Clamp is not included with the XSP/XSR. 10

Single Rack Models 482mm 45mm 112mm cable length approx. 145cm Mains plug (US-Versions only) Double Rack Models 482mm 45mm 112mm cable length approx. 145cm Mains plug (US-Versions only) 11

Single Rack Terminal Models 482mm 45mm 112mm Double Rack Terminal Models 482mm 45mm 112mm 12

Terminal Models The terminal models of the XSP/XSR comes with plugable treminal blocks. The terminal blocks are located at the rear of the device. XSP/XSR terminal models are shipped with the terminal blocks. They can accept wires up to AWG 17 (~1mm 2 ) Installation model The XSP/XSR installation modell is made to be installed by certified professionals. This version has no plugs. All connections are located inside of the device. thru port input port mains output ports cover grommets 13

XSP standard program 10 11 63 XSP-3B 11 11 63 XSP-3B-US (with NEMA 5-15) 10 11 74 XSP-3R 11 11 74 XSP-3R-US (with NEMA 5-15) 10 11 85 XSP-3R-3R 11 11 85 XSP-3R-3R-US (with NEMA 5-15) 10 11 62 XSP-5B 11 11 62 XSP-5B-US (with NEMA 5-15) 10 11 72 XSP-5R 11 11 72 XSP-5R-US (with NEMA 5-15) 10 11 82 XSP-5R-5R 11 11 82 XSP-5R-5R-US (with NEMA 5-15) 14

10 11 60 XSP-5B5 11 11 60 XSP-5B5-US (with NEMA 5-15) 10 11 70 XSP-5R5 11 11 70 XSP-5R5-US (with NEMA 5-15) 10 11 80 XSP-5R5-5R5 11 11 80 XSP-5R5-5R5-US (with NEMA 5-15) 10 11 87 XSP-5R2-5R2 11 11 87 XSP-5R2-5R2-US (with NEMA 5-15) 10 11 84 XSP-5R-5R5 11 11 84 XSP-5R-5R5-US (with NEMA 5-15) 10 11 86 XSP-5R-3R 11 11 86 XSP-5R-3R-US (with NEMA 5-15) 15

OUT 5 OUT 4 OUT 3 OUT 2 OUT 1 OUT 5 OUT 4 OUT 3 OUT 2 OUT 1 THRU IN OUT 5 OUT 4 OUT 3 OUT 2 OUT 1 THRU IN THRU IN 10 11 50 XSP-TR5 11 11 50 XSP-TR5-US (with NEMA 5-15) 10 11 51 XSP-TR5-TR5 11 11 51 XSP-TR5-TR5-US (with NEMA 5-15) 10 11 98 XSP-IB5-W XSR standard program 10 12 10 XSR-3B 11 12 10 XSR-3B-US (with NEMA 5-15) 10 12 20 XSR-3R 11 12 20 XSR-3R-US (with NEMA 5-15) 10 12 30 XSR-3R-3R 11 12 30 XSR-3R-3R-US (with NEMA 5-15) 16

10 12 11 XSR-5B 11 12 11 XSR-5B-US (with NEMA 5-15) 10 12 21 XSR-5R 11 12 21 XSR-5R-US (with NEMA 5-15) 10 12 31 XSR-5R-5R 11 12 31 XSR-5R-5R-US (with NEMA 5-15) 10 12 16 XSR-5B5 11 12 16 XSR-5B5-US (with NEMA 5-15) 10 12 26 XSR-5R5 11 12 26 XSR-5R5-US (with NEMA 5-15) 10 12 33 XSR-5R5-5R5 11 12 33 XSR-5R5-5R5-US (with NEMA 5-15) 17

OUT 5 OUT 4 OUT 3 OUT 2 OUT 1 OUT 5 OUT 4 OUT 3 OUT 2 OUT 1 THRU IN OUT 5 OUT 4 OUT 3 OUT 2 OUT 1 THRU IN THRU IN 10 12 35 XSR-5R2-5R2 11 12 35 XSR-5R2-5R2-US (with NEMA 5-15) 10 12 34 XSR-5R-5R5 11 12 34 XSR-5R-5R5-US (with NEMA 5-15) 10 12 32 XSR-5R-3R 11 12 32 XSR-5R-3R-US (with NEMA 5-15) 10 12 50 XSR-TR5 11 12 50 XSR-TR5-US (with NEMA 5-15) 10 12 51 XSR-TR5-TR5 11 12 51 XSR-TR5-TR5-US (with NEMA 5-15) 10 12 51 XSR-IB5-W 18

Technical Data Mains Voltage 110 / 230 [VAC] Main Frequency Current Consuption Single Units Current Consuption Double Units 50/60 [Hz] 0.25 [A] 0.5 [A] Operating Temperature 0F to 130F (-17C to 55C) Protocol Standard Safety Standards EMC emmision EMC immunity ANSI E1.11 (DMX-512) ANSI E1.20 (RDM) EN60950-1 UL????? EN50081-1 EN50081-2 EN50081-1 EN50081-2 Safety notes Consider the following notes absolutely when you set up, connect and use the XSP / XSR Connect the cables only with the proper plugs and sockets. Set the cables in an accident-proof fashion. Connected cables mustn't be stressed mechanically too much. Keep the device away from sources of electrical interference.. Only connect accessories certified for use with this device. Never open the device yourself. Don't touch the plug contacts with metal or sharp/pointed objects. Clean the XSP/XSR DMX Splitter only with a soft, damp cloth. Don't use chemicals or scrubbing means. Protect the device against against exposure to: excessive humidity, liquids, moisture, dust, direct sunlight. Do not use the device in areas where it is exposed to direct sunlight. Do not use the device in areas that are considered to be 'highly combustible'. 19

20