Operation Manual. Equipment. Operation Manual. Loctite RB30 Robot Camera. Part Number:

Similar documents
Loctite Light Intensity Monitor Part Number EQUIPMENT Operation Manual. Light Intensity Monitor. Item No Set to 100% Run Mode

Loctite CL20 LED ARRAY 4 CHANNEL SYSTEM. EQUIPMENT Operation Manual. CL20 Controller Part Number: CL20 Expansion Module Part Number:

EQUIPMENT Operation Manual

EQUIPMENT Operation Manual

EQUIPMENT Operation Manual

EQ CL30 LED Quad Controller. Operating Manual

Loctite Digital Multi-Functional Controller Part Number EQUIPMENT Operation Manual

EQ ACCE D-Series Robot Software Kit. Operating Manual

EQ ACCE Robot D-Series Junc Box 24V IDH #: Equipment Instructions

EQ RB40 BENCHTOP D-ROBOTS OPERATION MANUAL

REV: B BENCHTOP 24V D-ROBOTS OPERATION MANUAL

EQUIPMENT OPERATION MANUAL. Cartesian 200, 300, 400 and 500 Series. Setup. For Qualified Installer ONLY

User Guide. Control Box. RoscoLED TM.

USB Server User Manual

SP-C1 Mobile Docking Station Installation Guide

Woolich Racing. USB ECU Interface User Guide

THECHARGEHUB.COM. User Manual. For Square & Round Models

WCC100 IN-VEHICLE CHARGING CRADLE OWNER S MANUAL

DISCONTINUED PRODUCT DISCONTINUED PRODUCT

Start Here. All-in-One Printer. Print Copy Scan

Sonic Ruptor 400. User Manual

USB 3.0 Spectra

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE

HP Limited Warranty Statement Printers and Imaging Products

1X2 HDMI Splitter with 3D Support

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

PIM-Mini Pulsed Current Source Operation Manual

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

HDMI Extender over Cat5e/6

Piccola Smart Box Member of Modul MAS family

STAINLESS STEEL CAST FITTINGS 150lb 304 & 316 Stainless Steel Cast Fittings Specifications

Benchmark Plus Microplate Reader User Manual. This Instrument for Laboratory Use Only Rev C

200D BENCHTOP ROBOT OPERATION MANUAL

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

CubePro. Main PCB Replacement Guide. Prosumer 3D Printer. Original Instructions

What s in the Box? Weatherproof Camera transmitter with Antenna Power Cable 3m Sticker. 2 RVS SyStemS

TRENDnet User s Guide. Cover Page

User's Guide. Model High Precision Quad Output DC Power Supply

INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE

Logitech Alert 700i/750i System Requirements & Support Guide

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE

PCMCIA Flash Card User Guide

MPP200 User s Manual

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Wall. No opening (Example: LA-030-W)

TD 600 Thermo-Fastprinter

What s in the box. SUP paddle sensor. Paddle sensor mounting track. Charger. USB cable. In your Motionize SUP kit you will find:

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

Install Motor Controller User Manual

2 Welcome and Congratulations

EPSON PreferredSM Limited Warranty Program for the Epson Stylus

Card Enrollment Station. User Manual UD05870B

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

S82S (3/7.5-W Models)

PSA200 User s Manual

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

Start Here. All-in-One Printer. Print Copy Scan

Remote Refrigeration Control

iq 16 Sync Charge Box

WARRANTY & LIMITATION OF LIABILITY

Conductive Level Controller

User Manual TLS HDMI Switch Splitter 3/2

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

PCM-7140 Pulsed Current Source Operation Manual

SATA II HDD Canister KISS DA 435 Quick Reference Guide

COOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

Grundfos MAGNA, GENI Module

LAUNCH TECH CO., LTD.

The EB7-4W plugs onto one- or two-channel speaker or headset stations as illustrated in Figure 1. EB7-4W. Option. 4-Wire. Option

Proliphix EPA-60 Installation Guide

B/W PAN/TILT FIXED DOME CAMERA

Automated Tuner System Power Distribution Hub

Thermocouple Input Module

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

Everything in its place. OWNER S MANUAL. TRINITY 56 ROLLING WORKBENCH STAINLESS STEEL Model # TLS-4804 (Stainless Body) TLS-4805 (Black Body)

USB Transfer Cable. for Windows and Mac User s Guide

Quick Installation Guide TV-H510 H/W: V1

USB Ranger Fiber Optic USB 2.0 Extender. User Guide

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

E4C-UDA CSM_E4C-UDA_DS_E_12_2

Instruction and Operation Manual. CRMS Contact Resistance Measurement System. Model Number Caution!

User s Manual. PCI Bus Expansion Adapter for PCI Bus PC-Slot EAD(PCI)BE PCI Bus Expansion Adapter for Low Profile PCI PC-Slot EAD(LPCI)BE

FNet Repeater Installation & Operator s Instruction Manual

HDEXT50M USER MANUAL Extend HD Signals over CAT 5/5e/6 up to 164ft.(50m) All Rights Reserved Version: HDEXT50M_2017V1.2

PRODUCT INSTRUCTIONS D2 SERIES ENCLOSURES

FTC-200 X-ray Tube Controller Users Manual

62533 Ethernet Adapter

Warranty and Legal Information

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

PC-HELPER. Expansion Adapter for Express Card Slot EAD-CE-EC. User s Manual CONTEC CO.,LTD.

To purchase additional handsets (DCX640), visit our web site at

2014 MPE5 Covert Scouting Camera Instruction Manual

PREFACE. Thank you for choosing Zen Space Desks. We hope your desk helps you find your zen when being used. Zen Space Desks Team

MP3 Speaker USER GUIDE

ASUS Motherboard Warranty Card

Transcription:

Operation Manual Equipment Operation Manual Loctite RB30 Robot Camera Part Number: 1912406

Operation Manual 1 1.1 1.2 1.3 1.4 1.5 2 2.1 2.2 3 3.1 3.2 3.3 4 5 Table of Contents Please Observe the Following...3 Emphasized Sections...3 For Your Safety...3 Safety Precaution...4 Unpacking...4 Overview...4 Install Camera...6 Hardware Installation...6 Wire Connection...8 Get Started...9 CCD Setup...9 Tip Setup...10 Edit Path Mode...11 Accessories & Spare Parts...11 Equipment Warranty...12 - Page 2 -

1 Please Observe the Following 1.1 Emphasized Sections WARNING! Refers to safety regulations and required measures that protect the operator or other persons from injury or danger to life. Caution! Emphasizes what must be done or avoided so that the unit or other property is not damaged. Notice: Gives recommendations for better handling of the unit during operation or adjustment, as well as for service activities. 1.2 For Your Safety For safe and successful operation of the unit, read these instructions completely. If the instructions are not observed, the manufacturer can assume no responsibility. Be sure to retain this manual for future reference. WARNING! Always wear temperature resistance gloves before touch the housing of dispensing head or pre heater. WARNING! Never remove the cover of the unit without first switching the power off and unplugging the power cord. WARNING! Damage to the power cord or the housing can result in contact with live electrical parts. Check the power cord and housing before each use. If the power cord or unit is damaged, do not operate. The unit may be repaired only by a Loctite authorized service technician. - Page 3 -

1.3 Safety Precaution In order to meet the requirements of the European Community (CE) safety directives, the robot must be placed in an enclosure supplied by Henkel. Make sure the robot is connected to a properly grounded power source before operating. Keep away from any moving parts while the robot is running. Loading and unloading of parts and material must only be done when the robot is at a complete stop. Changing of fixtures or tooling must be done with the power source disconnected. The EQ RB30 Robot Camera should only be operated in an environment between 10 and 40 degrees Celsius with humidity of 20 to 95 percent and no visible condensation. Do not store or setup the robot in an area where it is directly exposed to sunlight. Do not operate the robot where electrical noise is present. Only use a neutral chemical for cleaning the robot. Do not use alcohol, benzene or thinner as it may damage the paint on the robot. 1.4 Unpacking Lift with care Remove all accessories from the shipping package before attempting to remove the camera. Place the camera on a stable workbench before operating. If you can, do not discard the packing material as these items may be needed if the robot camera is shipped or moved in the future. 1.5 Overview Note: Robot is not included. - Page 4 -

1. Power Inlet 2. Main Switch 3. 12VDC Port 4. 12VDC Port 5. Screen 6. Screen Bracket 7. Power Box 8. Bracket 9. CCD Bracket 10. CCD 11. Lens - Page 5 -

2 Install Camera 2.1 Hardware Installation Step 1. Remove X-axis s plate (1) of robot as below picture shown. Step 2. Follow below picture, install bracket (2). - Page 6 -

Step 3. Follow below picture, mount bracket (3) on D Robot Step 4. Mount other bracket and CCD. - Page 7 -

Step 5. Mount display and electrical cabinet. 2.2 Wire Connection - Page 8 -

3 Get Started A D-series robot with firmware version H6.1.1.293 is needed. You are required to teach in offset between CCD and Tip at beginning. Please go to menu F4 CCD Setup and Tip Setup. 3.1 CCD Setup A CCD system with camera can be mounted on robot. You can program path by CCD and run by tip. You will need to target an existing point by both CCD and tip, so system can calculate the offset between lens and needle tip. System will recognize the offset and switch between those 2 modes. Instruction F4 Menu Page 4 CCD Setup Display Shows [CCD Setup] X:0.00 Y:0.00 Z:0.00 1:Save 2:Move Select: Move CCD to an existing point and target it by lens, make the point in the cross point of CCD screen. Press numbers to select if you want to Save or Move. Then press ENTER. Save: System will record current coordinate as reference coordinate, and use this coordinate when calculate offset to Tip mode. [CCD Setup] X:0.00 Y:0.00 Z:0.00 1:Save 2:Move Select: Move: Robot will move to previous coordinate that have done tip setup before and have been saved in system. - Page 9 -

Instruction Select. Then press ENTER. Display Shows [CCD Setup] X:0.00 Y:0.00 Z:0.00 1:Save 2:Move Select:1 3.2 Tip Setup Instruction F4 Menu Page 4 Tip Setup Display Shows [Tip Setup] X:0.00 Y:0.00 Z:0.00 1:Save 2:Move Select: Move tip to the same point which was used when CCD setup and target it. Press numbers to select if you want to Save or Move. Then press ENTER. Save: System will record current coordinate as reference coordinate, and use this coordinate when calculate offset to CCD mode. Move: Robot will move to previous coordinate that have done tip setup before and have been saved in system. Select. Then press ENTER. [Tip Setup] X:0.00 Y:0.00 Z:0.00 1:Save 2:Move Select: [Tip Setup] X:0.00 Y:0.00 Z:0.00 1:Save 2:Move Select:1 - Page 10 -

3.3 Edit Path Mode System can run in both CCD and Tip mode. Mode can be switched in this command. Instruction F4 Menu Page 4 Edit Path Mode Display Shows [Edit Path Mode] Tip 1:Tip 2:CCD Select: Select running mode. Then press ENTER. I.e. To set running mode to CCD, press 2 then press ENTER. System will run path regarding CCD mode s coordinate Select. Then press ENTER. [Edit Path Mode] Tip 1:Tip 2:CCD Select: ---------- [Edit Path Mode] Tip 1:Tip 2:CCD Select:2 ---------- 4 Accessories & Spare Parts Loctite Item Number Description Robot 2103369 RB40 500D 24V Benchtop Robot 2104795 RB40 400D 24V Benchtop Robot 2104799 RB40 300D 24V Benchtop Robot 2104801 RB40 200D 24V Benchtop Robot 2112253 RB15 200D Gantry Robot - Page 11 -

5 Equipment Warranty Henkel expressly warrants that all products referred to in this Instruction Manual for 1912406 EQ RB30 Robot Camera (hereafter called Products ) shall be free from defects in materials and workmanship. Liability for Henkel shall be limited, as its option, to replacing those Products which are shown to be defective in either materials or workmanship or to credit the purchaser the amount of the purchase price thereof (plus freight and insurance charges paid therefor by the user). The purchaser s sole and exclusive remedy for breach of warranty shall be such replacement or credit. A claim of defect in materials or workmanship in any Products shall be allowed only when it is submitted in writing within one month after discovery of the defect or after the time the defect should reasonably have been discovered and in any event, within 12 months after the delivery of the Products to the purchaser. This warranty does not apply to perishable items, such as (fuses, filters, lights, etc.). No such claim shall be allowed in respect of products which have been neglected or improperly stored, transported, handled, installed, connected, operated, used or maintained. In the event of unauthorized modification of the Products including, where products, parts or attachments for use in connection with the Products are available from Henkel, the use of products, parts or attachments which are not manufactured by Henkel, no claim shall be allowed. No Products shall be returned to Henkel for any reason without prior written approval from Henkel. Products shall be returned freight prepaid, in accordance with instructions from Henkel. NO WARRANTY IS EXTENDED TO ANY EQUIPMENT WHICH HAS BEEN ALTERED, MISUSED, NEGLECTED, OR DAMAGED BY ACCIDENT. EXCEPT FOR THE EXPRESS WARRANTY CONTAINED IN THIS SECTION, HENKEL MAKES NO WARRANTY OF ANY KIND WHATSOEVER, EXPRESS OR IMPLIED, WITH RESPECT TO THE PRODUCTS. ALL WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND OTHER WARRANTIES OF WHATEVER KIND (INCLUDING AGAINST PATENT OR TRADEMARK INFRINGEMENT) ARE HEREBY DISCLAIMED BY HENKEL AND WAIVED BY THE PURCHASER. THIS SECTION SETS FORTH EXCLUSIVELY ALL OF LIABILITY FOR HENKEL TO THE PURCHASER IN CONTRACT, IN TORT OR OTHERWISE IN THE EVENT OF DEFECTIVE PRODUCTS. WITHOUT LIMITATION OF THE FOREGOING, TO THE FULLEST EXTENT POSSIBLE UNDER APPLICABLE LAWS, HENKEL EXPRESSLY DISCLAIMS ANY LIABILITY WHATSOEVER FOR ANY DAMAGES INCURRED DIRECTLY OR INDIRECTLY IN CONNECTION WITH THE SALE OR USE OF, OR OTHERWISE IN CONNECTION WITH, THE PRODUCTS, INCLUDING, WITHOUT LIMITATION, LOSS OF PROFITS AND SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER CAUSED BY NEGLIGENCE FROM HENKEL OR OTHERWISE. - Page 12 -

Henkel Corporation One Henkel Way Rocky Hill, CT 06067-3910 Henkel Corporation Automotive / Metals HQ 32100 Stephenson Hwy. Madison Heights, MI 48071 Henkel Canada Corporation 2515 Meadowpine Boulevard Mississauga, Ontario L5N 6C3 Henkel Ltda. Rua Karl Huller, 136 Jd. Canhema 09941-410 Diadema/SP, Brazil Henkel Capital, S.A. de C.V. Calzada de la Viga s/n Fracc. Los Laureles Loc. Tulpetlac, C.P. 55090 Ecatepac de Morelos, Edo. de México www.loctite.com and designate trademarks of Henkel Corporation or its affiliates. = registered in the U.S. and elsewhere. Henkel Corporation, 2009. All rights reserved. Data in this operation manual is subject to change without notice. Manual P/N: 8905179, Date: 01/16/2017 - Page 13 -