Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

Similar documents
Installation and commissioning guide SmartLink Host Communication Module (HCM-GPU)

Engauge Quick Start Guide

SmartLink Configuration Manual

Power Supply HARTING pcon

Power Supply HARTING pcon

MINI-PS AC/10-15DC/8

Instruction manual XPU-2 option RS-232C / RS-485

Operating instructions. Speed monitor D / / 2014

CPCI-PS24 24V-Power Supply

Redundancy Module QUINT-DIODE/40

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating and mounting instructions

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

FLEX Ex Spring Clamp Terminal Base

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and functional description

Installation manual for for Schleifenbauer DPM3

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Product and functional description

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Extension module for lighting control

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

Redundancy unit CP-A RU

Language of the manual

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 07/2006

Installation Instructions

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Resistance measuring module

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Power supply module, bus connection module

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Operating instructions. Standstill monitor A / / 2011

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

PTC/PT100 board 2.0 Option

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

PanelView Plus/VersaView CE Terminals and Display Modules

DC562, digital input/output module,

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

DC561, digital input/output module,

PI-EX-ME-2NAM/COC-24VDC

PRODUCT SPECIFICATION. PC Board Relays. Series.

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

Ultra Slim Relays 24

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Priva Blue ID Analogue output module with manual override AO2m/AO4m

DIN Rail. user manual Models , & INT /503556/ UM

Digital input modules

DI561 Digital Input Module

Installation manual plugs and connectors with screw connection (16/32 A)

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

Installation guide Ensite Pro Configuration Tool

Priva Blue ID Digital input module DI4/DI8/DI16

Power supply CP-C 24/5.0

Product and functional description

Power Supply, Primary Switch Mode for Universal Use QUINT-PS AC/48DC/5

Rhino PSM Power Supplies. Operating Instructions


DX561 Digital Input/Output Module

Priva Blue ID Communication module RS485 SC44

Installation Instructions

PI-EX-ME-2NAM/COC-120VAC

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Product and functional description

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

TXM1.8RB. TX-I/O Blinds module

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

SITOP in the SIMATIC Design

ETD-BL-1T-OFF-CC- 10S

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

AI561 Analog Input Module

Standard-Signal Isolation Amplifiers. VariTrans A 21000

Input Voltage Range AC Input. Input Frequency Range. Output Power natural convection. Operating Temperature Range. Model Selection

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

ABL8MEM12020 regulated SMPS - 1 or 2-phase V AC - 12 V - 2 A

CMC III Universal Sensor

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

EX-RC1 Remote I/O Adapter

Simple but elegant look and ease of installation make it ideal for various industrial applications.

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

PHOENIX CONTACT - 05/2007

ABL8MEM12020 regulated SMPS - 1 or 2-phase V AC - 12 V - 2 A

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Priva Blue ID Relay output module DOR4/DOR8

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG MANUEL D INSTALLATION RD-48 LV/HV. RS-422/485 Repeater Répéteur RS-422/485

Transcription:

Installation and commissioning guide SmartLink PSD Power Supply Module (DC) Rev. 1 September 2012 Part No. 4417551 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com Website : http://www.honeywell.com SmartLink PSD Page 1

Copyright 2012 Enraf BV All rights reserved. Reproduction in any form without the prior consent of Enraf BV is not allowed. This manual is for information only. The contents, descriptions and specifications are subject to change without notice. Enraf BV accepts no responsibility for any errors that may appear in this manual. The warranty terms and conditions applicable in the country of purchase in respect to Enraf BV products are available from your supplier. Please retain them with your proof of purchase. Page 2 SmartLink PSD

1 Preface This manual describes the installation and commissioning procedure of the SmartLink PSD power supply module. It contains all the necessary information for installation, commissioning and maintenance of this product. Safety and prevention of damage Always adhere to the instructions in this manual. In case of doubt, or problems, always consult your Enraf representative. Refer to the front cover for contact information. Additional information Please do not hesitate to contact Enraf or its representative if you require additional information. Declaration of conformity This device fulfills the requirements of the following directives low voltage directive 73/23EEC EMC directive 89/336EEC CSA approval conform CAN/CSA 60950-1-03 and UL 60950-1 Legal aspects The information in this manual is copyright property of Enraf BV, Netherlands. Enraf BV disclaims any responsibility for personal injury or damage to equipment caused by: Deviation from any of the prescribed procedures; Execution of activities that are not clearly documented. SmartLink PSD Page 3

Table of contents 1 Preface... 3 2 Introduction... 5 2.1 The SmartLink modular concept.. 5 2.2 Preparation before installation.. 5 2.3 Identification. 5 2.4 Functional description. 6 3 Safety... 7 3.1 EMC... 7 3.2 Special conditions for use.. 8 4 Mechanical specifications... 9 4.1 Dimensions.. 9 4.2 Weight.. 9 4.3 Climatic Conditions 10 5 Mechanical installation... 11 5.1 Installation of the DIN-rail. 11 5.1.1 Using the DIN-rail connectors. 11 5.1.2 Clicking the connector onto the rail 11 5.1.3 Compiling a SmartLink system 11 5.2 Mounting the SmartLink module. 13 5.3 Dismounting the SmartLink module 14 6 Electrical specifications... 15 6.1 Supply parameters 15 7 Electrical installation... 16 7.1 Connecting the PSD module 16 7.2 Removing the connection. 18 7.3 Configuration.. 18 7.4 LED.. 18 8 Disposal... 19 9 Maintenance... 19 Page 4 SmartLink PSD

2 Introduction 2.1 The SmartLink modular concept The 780 SmartLink provides a gateway to terminal automation related field instrumentation. With the modular design of the SmartLink this bridge concept is scalable from small to medium tank terminal installations. The SmartLink modular concepts consist of separate modules on a DIN-rail. Available modules include: PSD (Power Supply DC), HCM (Host Communication Module) for communication with the PC, and FCM (Field Communication module) for communication with the field instruments. 2.2 Preparation before installation Visually check the product for damage. Contact your Enraf representative in case of damage. Check the delivery for completeness. The package should contain: - the SmartLink power module - 1 DIN-rail connector - 1 termination clip Immediately contact your Enraf representative if the delivery is incomplete. 2.3 Identification The SmartLink module is equipped with a label on the right side (front of the unit toward viewer) of the casing. The label is shown below. The following label is attached to the DC Power Supply SmartLink module: SmartLink PSD Page 5

Figure 1 SmartLink PSD label The following label is attached to the connector: Figure 2 PSD connector layout 2.4 Functional description The SmartLink PSD is a plug-and-play DC power supply module that converts the DC-power into a 15 VDC power for the other SmartLink modules that are installed on the DIN-rail. Page 6 SmartLink PSD

3 Safety The module, when integrated in a system, complies with the safety specifications as denoted in the table below: Applied (safety, approval) standards Item Specification Low voltage EN-IEC60950-1:2000 + A11 : 2004 directive CAN/CSA 60950-1-03 UL 60950-1 Definitions Pollution degree = 2 Installation Category = I Permanent equipment type A Secondary side is SELV Restricted access area Class I equipment Over voltage category = II (2500V transient) This module must only be installed by sufficiently trained and experienced personnel, taking into account the relevant national, local and company regulations. 3.1 EMC The PSD power supply module complies with the EMC specifications according to the following standards: Type Item Standard Specific level/criteria Emission General emission EN-IEC61000-6-4: Immunity General immunity EN-IEC61000-6-2 Ensure that the module is installed by sufficiently trained personnel, aware of the EMC aspects. SmartLink PSD Page 7

3.2 Special conditions for use When using the power supplies in a system, the following integration requirements must be met: 1. The modules must be mounted on the DIN-rail, which must comply with EN-50022 and should have the following dimensions: Height = 7.5 mm; width = 35 mm 2. All modules may only be used in a restricted access area as defined by EN60950 and that requires a warning label in this area and a cover or door as specified by IEC60950. The modules should be installed in a fire enclosure with a minimal protection class 5VB. 3. The safety is only prolonged and guaranteed by connecting the earth terminal to earth with proper wire and bonding as specified by EN60950. 4. The unit may not supply an Ex i circuit in the context of EN50020/EN60079-11 because GND is connected to earth and cannot provide for isolation of the output V dc and GND to earth. 5. The SmartLink Power Supply module has bus termination and thus must be placed at the beginning of the bus DIN rail (on the left). 6. If connected to an IT power system, a double pole disconnect and protective device must be placed between the building installation and the PSD unit. 7. The DIN rail must also be connected to the system earth. 8. The terminal/connector screws must be fastened properly (due to the protection class). 9. Wire diameter should be 1.5mm 2 minimum or 2.5mm 2 maximum. Page 8 SmartLink PSD

4 Mechanical specifications 4.1 Dimensions Figure 3 Dimensions SmartLink module A = 114 mm (4.49 ) B = 117 mm (4.61 ) The width is 45 mm (1.77 ) Note: Take into account that an additional space of appr. 35 mm is required above a SmartLink module for mounting / dismounting purposes. (Refer to section 5.3). 4.2 Weight The PSD module weighs 242 grams. SmartLink PSD Page 9

4.3 Climatic Conditions The SmartLink Power Supplies comply with the environmental conditions as defined in the table below. Operating temperature -20 o C to +60 o C (-4 o F to +140 o F) Storage temperature -40 o C to +85 o C (-40 o F to +185 o F) Protection class (SmartLink) IP 20 (EN 60529:2000, NEMA) Relative humidity 20-95%, non condensing Page 10 SmartLink PSD

5 Mechanical installation 5.1 Installation of the DIN-rail 5.1.1 Using the DIN-rail connectors The SmartLink PSD module can only be installed onto the connector supplied with the delivery. Do not use any other connectors. 5.1.2 Clicking the connector onto the rail Click the connector onto the rail. Take into account that any additional modules should be added to the right hand side of this module, so click the connector onto the DIN-rail as far left as possible and convenient. To ensure adequate heat dissipation, a space of 5 cm (2 ) left of the power supply module should be kept clear. Also click the connectors of any additional SmartLink modules that are also to be installed onto the DIN-rail and make sure they are properly linked together. Figure 4 Connectors on DIN-rail 5.1.3 Compiling a SmartLink system As mentioned in section 2.1, the SmartLink system consists of a power supply module, a HCM and 1-3 FCM s. The modules are added from left to right in the sequence as indicated in the figure below. SmartLink PSD Page 11

Always place a termination clip at the far right hand side, i.e. to the right hand side of the rightmost FCM. Without this termination the SmartLink system will not work properly. Also refer to the relevant manuals. Figure 5 SmartLink modules on DIN-rail From left to right: 1 The power supply unit 2 The host module (HCM) 3 Field communication module(s) (FCM) 4 Termination clip (also shown in picture below) Page 12 SmartLink PSD

Figure 6 Termination NOTE! Always adhere to this sequence. Ensure the Termination clip is in place, otherwise the system will not operate. 5.2 Mounting the SmartLink module The PSD module is fitted with a fixed bus termination and must therefore always be placed as the first module on the rail, on the left hand side. Ensure that it is placed onto the connector in such a way, that the connector is no longer visible from the left hand side. Hold the module upright, place the base on the connector that is fitted onto the DIN-rail. Ensure that the notch marked 1 is engaged first and click the module onto the DIN-rail with the tilting movement as indicated by arrow 2 (refer to figures 7 ad 8). SmartLink PSD Page 13

Figure 7 Side view of module Figure 8 Clicking the module onto the connector on the DIN-rail 5.3 Dismounting the SmartLink module Figure 9 Removing the module from the DIN-rail A module that is mounted on the DIN-rail can be removed by placing a blade screwdriver under the notch (refer to the figure) and making a slight upward leveraging movement, lifting the module of the rail at the same time. Do NOT use excessive force. Page 14 SmartLink PSD

6 Electrical specifications 6.1 Supply parameters Parameter Specification V dc, Output Voltage 15.0V DC ± 4% Continuous Output current 1 A. Input Voltage 24-65 VDC (±10%) F, Input Fuse Value 1 AT (internal fuse on PCB may only be replaced by Enraf!) Ripple and noise Load Regulation Minimum Load Max. C Load Short circuit current Start up time Isolation Voltage Operation Temperature Range < 1.5 % of V dc < 1% of V dc 50 ma. 2000 μf 1.2A peak hick-up mode, restart time 1.5[s] < 1 s > 500 VDC -20 C - +60 C (-4 F - +140 F) SmartLink PSD Page 15

7 Electrical installation Warning: Do not connect anything else to the DIN-rail connectors but the SmartLink modules. Ensure the power supply is switched off or disconnected, and secured against switching on again, before commencing the installation. Ensure that the local power supply voltage matches the voltage stated on the module. In order to ensure a safe operation of the module, it should only be connected to a mains supply that is fused with a maximum value of 35A. Safety depends on the correct earthing of the instrument. Therefore check the resistance of the earth connection immediately after installation; the maximum resistance should correspond with the local earth resistance requirements. The module is equipped with an internal fuse, which may only be replaced by the manufacturer. 7.1 Connecting the PSD module First ensure that the module has been properly mounted onto the rail as defined in section 5.2. The PSD module is connected via the four pin external connector CN2, which can be accessed by opening the green hinged cover. Although not necessary for the electrical installation, the connector can be removed if required by using a small blade screwdriver, see figure 10: Page 16 SmartLink PSD

Figure 10 Removing the connector block First connect the safety earth on the connector terminal marked: to prevent leakage currents. Next connect the correct power supply to the terminals marked: + (positive) and - (negative) as indicated in Figure 2. The connector is placed again by inserting it and pushing upwards. Close the cover. It is not allowed to place or remove the connector when power is supplied to the module. In the direct vicinity of the power supply, a clearly recognisable on/off switch must be installed to control the power supply for the module. Use the correct wire (insulation thickness and core diameter) for the power supply voltage used. Take into account the local regulations. After the power supply is activated, the blue LED should be on, indicating the power supply module is working correctly. The underside of the module is designed in such a way that it can act as an open cable duct for the power supply cable, providing the core is 1.5 2.5 mm 2. SmartLink PSD Page 17

Figure 11 Underside of the module 7.2 Removing the connection Use the reverse of the above described procedure in order to disconnect the module. 7.3 Configuration The power supply module PSD does not require any configuration. 7.4 LED The power supply module is equipped with a blue LED on the front. The LED indicates the following: LED Meaning Required action OFF No power is supplied to the module or Ensure proper power supply to the module. ON Module is not working properly Power is supplied to the module and it is working properly Replace module. None Page 18 SmartLink PSD

8 Disposal The SmartLink module contains electronic components and should therefore, when defect or no longer used, be disposed of as electronic equipment according to the local regulations for this type of waste. 9 Maintenance The SmartLink module does not require any specific maintenance. Simply keep the module clean and remove dust when it accumulates. SmartLink PSD Page 19

Delftechpark 39 2628 XJ Delft Tel. :+31 15 2701 100 E-mail : enraf-nl@honeywell.com Website: http://www.honeywellenraf.com PO Box 812 2600 AV Delft The Netherlands We at Honeywell Enraf are committed to excellence. Information in this publication is subject to change without notice Enraf is a registered trade mark. Enraf B.V. Netherlands Page 20 SmartLink PSD