Simplified information where and how you want it.

Similar documents
Simplified information where and how you want it.

High Voltage DC Meter

HIGH-VOLTAGE DC METER

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Trident and Trident X2 Digital Process and Temperature Panel Meter

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Process & Temperature Digital Panel Meter

CATALOG SHORT FORM. Digital Indicators & Controllers. th ANNIVERSARY PRECISION DIGITAL CORPORATION Since 1974

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

PD Helios Dual-Line 6-Digit Temperature Meter. Actual Size Digit

KVIEW10/100 Field Controllers. Quad and multi-channel controllers K-TEK Products

dual-line 6-dIGIt process MeteR

PRECISION DIGITAL CORPORATION Since 1974 Dual-Line Large Display

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.

PD7000. PROVU Dual-Line 6-Digit Temperature Meter SERIES.

PRECISION DIGITAL CORPORATION Since CATALOG. level temperature pressure.

DUAL-LINE TEMPERATURE METER

ScanView EX Software Programming Software for PD6730X & PD6830X Modbus Scanners

PDW30 Point-To-Point Wireless Bridge

PD Large Display Feet & Inches Process Meter. Feet & Inches process. Actual Size Digit

PD Helios Strain Gauge, Load Cell & mv Meter. Strain gauge. Actual Size Digit

Large DIspLay process Meters

PD2-6080/PD Helios Super Snooper Modbus Scanners

CATALOG. Digital Indicators & Controllers. Simplifi ed information where and how you want it. Short Form. predig.com/videos

PD Large Display Dual-Line 6-Digit Process Meter. process. Actual Size Digit

PD Large Display Dual-Line 6-Digit Process Meter. process. Actual Size Digit

PDW90 WIRELESS. Point To Multi-Point Wireless FEATURES BASE STATION FIELD UNITS

PD6080/PD6081 PROVU Super Snooper Modbus Scanners

Short Form Catalog. Watch product videos at

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

DPM-300. Large Display Modbus Scanner. Modbus Master, Slave, or Snooper. Features

DPM-500. Dual-Line 6-Digit Process Meter FEATURES

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

PD6088/PD6089 PROVU Super Snooper Modbus Scanners

PD6210 / PD6310. PROVU Dual-Line 6-Digit Batch Controllers BATCH CONTROL. PRECISION DIGITAL CORPORATION SERIES

DPM-100. Dual-Line On-Board Serial Modbus Display FEATURES

PD6210 / PD6310. PROVU Dual-Line 6-Digit Batch Controllers. Batch control SERIES. Precision Digital Corporation

PD6000. PROVU Dual-Line 6-Digit Process Meter. SERIES

Welcome to the Webinar

Serial Communication Converters & Adapters Instruction Manual

PD6200 / PD6300. PROVU Dual-Line 6-Digit Flow Rate/Totalizers SERIES. Precision Digital Corporation

Intrinsically Safe Temperature Concentrator System

Snooper Model PD865 Modbus Serial Input Instruction Manual

The LT1300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

SPECIFICATIONS SPECIFICATIONS. Input VDC. NEMA 4X/IP65 front VDC option. Temp SPECIFICATIONS

PD6060. PROVU Dual-Input Process Meter SERIES.

Helios Large Display Temperature Meter

PD6262 / PD6363 SERIES. PROVU Dual-Input Rate/Totalizers. flow rate/total. Precision Digital Corporation

Flow Rate/Totalization Indicators

PD ProtEX-MAX Strain Gauge, Load Cell & mv Meter. Strain gauge. IECEx MAX

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

Helios Large Display Analog Input Meter

PD ProtEX-MAX TM Explosion-Proof Process Meter. IECEx MAX

Dual-Input process meter

PD ProtEX-MAX Analog Input Feet & Inches Meter. IECEx MAX

PD8-6080/PD6081 ProtEX-MAX TM Super Snooper Modbus Scanners

Webinar Organizers. Ryan Shea. Bruce McDuffee. Joe Ryan. Webinar Moderator. Applications Specialist. Product Manager. Precision Digital Corporation

PD6262 / PD6363. PROVU Dual-Input Rate/Totalizers. flow rate/total SERIES. Precision Digital Corporation

Javelin D Model PD644 Instruction Manual

Precision Digital Corporation 233 South Street Hopkinton MA USA Tel (800) Fax (508)

PRO VPR100 Series ViPR Multi Channel Monitoring System

PDA1002 DIN-Rail Mounting Kit for Two Modules

PD ProtEX-MAX TM Dual-Input Process Meter DUAL-INPUT PROCESS. IECEx. MAX

Meter Scanner & Controller

PD6262 / PD6363. PROVU Dual-Input Rate/Totalizers. flow rate/total SERIES. Precision Digital Corporation

LPG STM 94442A User s Manual

Master Panel. Specifications. Document No. TS-2010 February 15, Product Description. Sample Specification

ProtEX PDD6800 Series Demonstrators

BINVENTORY BINVENTORY SENSOR COMPATIBILITY

PDW30 Point-to-Point Wireless Bridge Installation Guide

Helios PD Large Display Meter Quick Start Guide

APS SCALE SERIES DIMENSIONS

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

PROVU PD6000 Analog Input Process Meter Instruction Manual

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

PD6000 Analog Input Process Meter Instruction Manual M387

Web-enabled DAQ System

AEXX-273 SERIES WIRELESS CONTROLLED PACE CLOCKS

Viatran DL Series Analog Input Process Meter Instruction Manual

TEK- LCD 7804B. Explosion-Proof Modbus Scanner. ACCESSORIES. Technology Solutions

PROVU PD7000 Temperature Meter Instruction Manual

INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.

DIGITAL METERS Large Display Process Meter With Rate/Totalizer/Batch Control Features Model PD656 Instruction Manual

700 SERIES DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL

Process Monitor Instruction Manual

iopro Mirrored IO System

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

for Fronius IG Plus V Inverters

CoMo Logic. Electronics & Software. Single-Channel y(t) ControlMonitor. Type 5875A...

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

Product Description. Contents. Fusion Series. New Information December 2003

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

OZONE SWITCH Model OS-6. OS-6 Features

PROVU PD6001 Analog Input Feet & Inches Meter Instruction Manual

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

700 SERIES FLOAT OPERATED DUPLEX/TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

PDW30 Point-to-Point Wireless Bridge

PD8-6200/PD ProtEX-MAX TM Dual-Line 6-Digit Flow Rate/Totalizers. IECEx. Precision Digital Corporation

Transcription:

ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator 8 Features Eight 4-20 Inputs Two 4-20 Outputs Common Features Four Pulse Inputs Four Digital Inputs Nine 10 A Relays Process/Rate & Total Display PDC Wireless Ready Advantages Easy to Read Backlit LCD Readable in Direct Sunlight Bargraphs & Numeric Screens Easy to Set up & Configure Set up with Front Panel Keys Intuitive Menus Detailed Individual Screens Input Simulation Feature RS-232 Modbus RTU Direct Modbus PV Inputs Power from AC or DC Wall or Panel Mount 32-Point Linearization Sum & Difference Functions Free Programming & Data Logging Software A Good Match for Wireless ConsoliDator 8 Model PD981 Precision Digital Corporation www.predig.com

ConsoliDator 4 & 8 Multi-Channel Controllers CoNFIGURATION The number one thing our customers like about the ConsoliDator is that it is easy to configure and use. Any other similar display would require complicated programming and still not have a user interface that is this friendly. The full-word prompts and graphical layout are so intuitive, you may have little use for the manual. While configuring the inputs, outputs, and functions the soft keys appropriately and clearly relabel the action of the front panel buttons making menu navigation quick and simple. Each configuration screen presents a clear non-cryptic summary of settable parameters and their current values. Inputs Channel # 1 Channel # 2 Channel # 3 Channel # 4 Channel # 5 Channel # 6 Channel # 7 Channel # 8 F low Meter # 1 Flow Meter # 2 Flow Meter # 3 Flow Meter # 4 General Functions Buzzer: ON OFF T-Out: ON OFF Change Password Save BL: YES NO Baud Rate: 19200 bps Parity: NONE - 8N1 Modbus ID: 1 Tx Delay: 0 ms MAIN SETUP MENU SCREEN Outputs Alarm Relay # 1 Alarm Relay # 2 Alarm Relay # 3 Alarm Relay # 4 Alarm Relay # 5 Alarm Relay # 6 Alarm Relay # 7 Alarm Relay # 8 Alarm Relay # 9 Analog Out # 1 Analog Out # 2 ENTER No ladder logic programming Front Panel Soft Keys PC-based software for configuration Full-word prompts Inputs Program Analog Input 1 Analog Input: 1 Input Type: 4-20 Transmitter Function: Linear Channel ID: TANK 1 Configure Display Parameters Configure Sensor Input Sensor: 10.93 Value: 3706.3 gal Alarms Alarm 1: HIGH MODE Alarm Setup: 1 Alarm Mode: HIGH Channel: [1] TANK: 1 High Value: 3000.0 gal Low Value: 2000.0 gal Delay ON: 5.0 sec Delay OFF: 5.0 sec Color shown for illustration only EDIT Program Flow Meter 1 Flow Meter: 1 State: Channel ID: Flow: 1 OFF K Factor: 100.00 pls / GAL Max Value: 50.00 GPM K-Fac Fmt: 9999.99 Rate Fmt: 9999.99 GPM Total Fmt: 9999.99 GAL Units: GAL & GPM Display: RATE Alarm 8: LEAD-LAG HIGH MODE Alarm Setup: 8 Alarm Mode: Channel: High Value: Low Value: LEAD_LAG: HIGH [5] WEST TANK 18.00 f&i 6.00 f&i Delay ON: 5.0 sec Delay OFF: 5.0 sec 0.5 Link Relays: sec 1 2 3 4 5 6 7 8 9 ON: Input & alarm screens shown ½ scale EDIT OVER EDIT All screens shown with backlight on 2

ConsoliDator 4 & 8 Multi-Channel Controllers Operation The ConsoliDator has an excellent graphical display and interface, presenting a quick view of the process while providing clearly and logically labeled operating keys.the main operation screen has a large bargraph display to quickly help spot trends or problems. It also indicates the precise numeric values for each PV input. Custom tag names and units of measure make the data more familiar, thus easier to read and understand. In addition to the three operation screens shown below, there are screens showing Digital Input States, Flow Meter Input Values, as well as a detailed numeric screens for each input. Cycle through all these screens with a push of a button. The ConsoliDator offers advanced operations without all the programming required by a PLC. MASTER INPUT SCREEN 1 2 3 4 5 6 7 8 1 3359.1 gal 2 4329.6 gal 3 2214.7 gal 4 4392.2 gal 5 19 10.4 6 89.32 ft 7 1404 GPM 8 848 GPM R1 R4 R5 R6 R7 SETUP AUTO ACK NEXT Bargraphs and Numeric Data Main Screen Shows all Inputs Individual Screens Show Detailed Data Manual Mode Screen Manual Mode Hours Cycles Relay #1: ON 5.7 14 Relay #2: OFF 2.9 15 Relay #3: OFF 2.4 5 Relay #4: ON 3.9 16 Relay #5: ON 3.3 24 Relay #6: ON 3.5 7 Relay #7: ON 3.3 9 Relay #8: OFF 0.7 1 Relay #9: ON 0.0 2 OFF RESET NEXT Individual Screens TANK 1 5000 gal H1 L1 H3 L3 3359.1 gal RELAY 1 ACTIVE Sensor In: 6.69 Alm: Low: High: 1: 2000.0 3000.0 ON 3: 500.0 1000.0 OFF 0 gal SETUP AUTO SIM ACK NEXT Color shown for illustration only Manual mode & individual screens shown ½ scale Key Points Shown View relay status On & off status Hours of operation Operation cycles Control relay operation Reset hours & cycles Toggle status on & off Key Points Shown Bargraph with set points Input identification Engineering units label (gal, ft, GPM) Alarm status Assigned alarms 1 & 3 Low & high set points On & off status Input simulation Test setup without applying an input All screens shown with backlight on 3

ConsoliDator 4 & 8 Multi-Channel Controllers MODBUS SERIAL PV INPUTS The ConsoliDator s inputs can be a combination of analog inputs and Modbus PV inputs which use the ConsoliDator s built-in RS-232 serial port. For the Modbus inputs, simply configure the input(s) to Fixed mode, then write the PV value to the appropriate Modbus register. The ConsoliDator must be the slave end of the communications. A pair of radio modems could make the communications wireless! Recent History Viewer PLC PD940 ConsoliDator 4 Tank 1 Level Tank 2 Level Tank 3 Level ConsoliDator Software Tank 4 Level Free PC based software is included with every ConsoliDator. With this software the user can monitor process variables, relay states, alarm states, and switch input states. The software can be used as a datalogger, or to configure the ConsoliDator. When an input channel is selected on the main display screen, a graph of recent history (last 5-10 minutes) can be viewed. A bargraph of its current value is also present. Data Logging Main Display The datalogger allows you to log the PVs over time. A CSV file is created so that the data can be used by a spreadsheet program. Log rate intervals can be set from 1 second to 10 minutes. Configuration On the main display screen of the software, the bargraph display not only shows the current PV value, it also shows any set and reset alarm points (gray lines on bargraph). On this screen you can also monitor relay and switch input states. The ConsoliDator can be remotely configured with this software by inputting the configuration data directly, or by copying a configuration from another ConsoliDator. Configurations can also be saved to your computer for future use. 4

WIRELESS Applications ConsoliDator 4 & 8 Multi-Channel Controllers Remote Level Sensing Remote Monitoring Here is an application where the level of 8 tanks are wirelessly monitored at practical and convenient locations without the need for expensive hard-wiring. The NEMA 4X enclosure contains wireless devices that convert the 4-20 level signals from the level transmitters into a digital signal that is wirelessly sent to a ConsoliDator (below). Local Display of Tank Level Data These four Trident displays receive retransmitted signals wirelessly from a remote ConsoliDator. They can be mounted from hundreds to thousands of feet away from the ConsoliDator depending upon the level of signal interference. Repeaters can be used to extend the range of wireless operation. Remote Office Connection to ConsoliDator This wireless ConsoliDator receives up to eight channels of process data and displays it in a practical location for easy monitoring. This same information can be wirelessly retransmitted via wireless serial Modbus to the office (at right), or up to (4) 4-20 retransmitted signals can be sent wirelessly to meters at a remote site (upper right) and displayed on any 4-20 input device (meter, recorder, datalogger, etc.). 5 Using the RS-232 Modbus serial output on the ConsoliDator, data can be analyzed and/or data logged remotely on a PC by utilizing a set of wireless radio modems and the free PC based software included with the ConsoliDator. The ConsoliDator can also be remotely configured using this software. Configuration files can be uploaded or downloaded to the PC and stored in the form of a spreadsheet. For more information on Wireless ConsoliDator, see our wireless data sheet at www.predig.com/consolidator

ConsoliDator 4 & 8 Multi-Channel Controllers Field Enclosures Connectors Diagram PDA2901 NEMA 4X Hinged clear cover Stainless steel quick-release latches Easy access to front panel buttons Power switch & fuse Shown with Optional Sub-Panel Hinged front mounting panel Extra space for additional components PDP2901 panel with terminal strips Captive screws See LDS2901 data sheet for additional details Disclaimer The information contained in this document is subject to change without notice. Precision Digital Corporation makes no representations or warranties with respect to the contents hereof, and specifically disclaims any implied warranties of merchantability or fitness for a particular purpose. 2009 Precision Digital Corporation. All rights reserved. The connectors diagram is silk-screened on the back of all panel mount ConsoliDators (PD941 shown here). ORDERING INFORMATION Model ConsoliDator Controllers Mount 4-20 Inputs Pulse Inputs 4-20 Outputs Relays PD940-8K9-15 Wall 4 4 4 9 PD941-8K9-15* Panel 4 4 4 9 PD980-8K9-15 Wall 8 4 2 9 PD981-8K9-15* Panel 8 4 2 9 ConsoliDator Software for programming and data logging is included free of charge with your purchase of any ConsoliDator Multi-Channel Controller. Model PDA2901* PDA2904 PDP2901* PDP2902* PDP2904 PDP2905 PDA6901 PDA6902 PDA7485-I PDA7485-N PDA8232-N PDA8485-I PDA8485-N PDA9232-01 PDA9232-02 Description Accessories NEMA 4X Enclosure for PD941 or PD981 Large NEMA 4X Enclosure for PD941 or PD981 Sub-Panel with Terminal Strips for PDA2901 Enclosure Sub-Panel w/o Terminal Strips for PDA2901 Enclosure Sub-Panel with Terminal Strips for PDA2904 Enclosure Sub-Panel w/o Terminal Strips for PDA2904 Enclosure 2" Pipe Mounting Kit for PDA2901 Enclosure 2" Pipe Mounting Kit for PDA2904 Enclosure RS-232 to RS-422/485 Isolated Converter RS-232 to RS-422/485 Non-Isolated Converter USB to RS-232 Converter USB to RS-422/485 Isolated Converter USB to RS-422/485 Non-Isolated Converter ConsoliDator Null-Modem Cable RS-232 Computer Cable PDX6901 Suppressor (snubber): 0.01 µf/470 Ω, 250 VAC * Quick Shipment Program product, typically shipped within 2 working days. 6

Ch1 Ch2 Ch3 Ch4 Ch 1: Ch 2: Ch 3: Ch 4: SETUP MANUAL ACK VIEW Ch 4: Ch 3: Ch 2: SETUP MANUAL ACK VIEW Ch 4: Ch 3: Ch 2: SETUP MANUAL ACK VIEW Ch1 Ch2 Ch3 Ch4 Ch 1: Ch 2: Ch 3: Ch 4: SETUP MANUAL ACK VIEW ConsoliDator 4 & 8 Multi-Channel Controllers Wall Mount Overall Dimensions Dia. 0.25 (6.3) 4 places Mounting Dimensions Units: Inch (mm) Ch1 Ch2 Ch3 Ch4 Ch 1: 12.000 13.000 14.000 15.000 8.75 (222) 8.00 (203) 3.0 (76) 8.0 (203) 7.25 (184) Panel Mount 9.36 (238) Panel 4 Clearance Holes Dia. 0.25 (6.3) Ch1 Ch2 Ch3 Ch4 Ch 1: 12.000 13.000 8.66 (220) 14.000 15.000 8.16 (207) 3.10 (79) 7.16 (182) Cutout: 8.35 x 7.37 (212 x 187) 7.86 (200) 8.86 (225) Enclosures 10.00 (254) 7.30 (185) 14 (356) 11 (279) ConsoliDator 8 ConsoliDator 8 12.000 12.000 15.75 (400) 13.000 14.000 15.000 MOUNTED CONSOLIDATOR 19 (483) 13.000 14.000 15.000 MOUNTED CONSOLIDATOR 15.00 (381) 18.5 (470) PDA2901 See LDS2901 data sheet for additional details PDA2904 7