Motor protection relays

Similar documents
MOTOR & CIRCUIT PROTECTION

Motor protection circuit breakers

TeSys IEC Contactors and Overload Relays

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Mini Contactors & Overloads

MOTOR PROTECTION CIRCUIT BREAKERS

3 Pole Contactors with AC operating coils

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

TeSys contactors From 115 to 2750 A

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

Square D General Purpose Relays

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

RW-E. Overloads. Solid-State Overload Relays. Standard Features

CS8 Industrial Control Relays

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

E1 Plus Electronic Overload Relay

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Max. Back-up fuse [A] 50 ka, 690V AC 5 ka, 600V AC IEC/EN Coordination Type 1 Type 2

Bulletin 817 Thermistor Protection Relay

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

02/11/2015

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

TeSys protection components

Datasheet - SRB 301LC/B-24V

K-Line Mini - Contactors, Overload Relays and Accessories

WEG Contactors - CWM and CWME Series

Circuit Breakers Type CTI 25M, CTI 45MB

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Zelio Control-modular measurement and control relays 1

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

Datasheet SRB301ST 24V (V.2)

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

K1D012ULH cam changeover switch - 2-pole A - screw mounting

Motor Controllers AC Semiconductor Motor Controller Type RSHR MIDI

Allen-Bradley 700-K40E-DJ

IDE Load break switches for machine control Remotely trippable switch from 32 to 160 A

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Rated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Technical data. Housing Polyamide housing PA 66, self-extinguishing V0 acc. to UL 94. Supply Rated supply voltage (U n

K1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

WMS SUPPLEMENTARY PROTECTORS

Push buttons and selectors

K1D004ACH cam switch - 4-pole A - for Ø 22 mm

100% electricity. Power factor correction components

Page 5-3. Page 5-2 Page 5-3

Overloads. RW Series Catalog Number Sequence. RW Series - Bi-Metallic Thermal Overload Relays. Standard Features 3 - RW 27-1D

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Micro Contactor MA Series

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

02/11/2015

Allen-Bradley 1492-RCDA4A40

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

K1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm

K1B004TLH cam switch - 1 pole A - screw mounting

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

XPSMP11123P module XPS-MP - 2 independent functions - 24 V DC

RM35TF V AC

RM4JA01F current measurement relay RM4-J - range ma V AC

Supplementary Circuit Protectors Type GSB63

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

Datasheet - SLB 200-C04-1R

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

ALLEN BRADLEY RELAY Bulletin 700-HF

PHOENIX CONTACT Features

Datasheet - SRB 402EM-24V

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

UL 489 DIN Rail Miniature Circuit Breakers

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

RM4TR31 three-phase network control relay RM4-T - range V

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Contact protection relay

RM4JA32MW current measurement relay RM4-J - range A V AC DC

Disconnect Switches. Safe Switching and Disconnecting

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

XCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20

UL 489 DIN Rail Miniature Circuit Breakers

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

CS7 Industrial Control Relays

XB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.

XB4BS542 red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC

Allen-Bradley Bulletin 100 Contactors

XB5AS8445 red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC

XCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

XCKP2145G11 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - Pg11

XCKM102 limit switch XCKM - steel roller plunger - 1NC +1NO - snap action - Pg11

RM4TA32 three-phase network control relay RM4-T - range V

Transcription:

Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30 Phase failure sensitive and non phase failure sensitive versions Automatic and/or manual resetting Independent or direct mounting on contactor Thermistor protection relay. Thermal overload relays SEC. - PAGE For BG series mini-contactors... 3-2 For BF series contactors... 3-4 For B series contactors... 3-8 Accessories... 3 - Electronic thermal overload relays For BF series contactors... 3 - Electronic relay Thermistor protection relays... 3-2... 3-3... 3-4... 3-5 TYPE OF THERMAL OVERLOAD RELAY ELECTRONIC THERMAL OVERLOAD RELAYS Type of contactor Phase failure / single phase sensitive Non phase failure / Pages Phase failure / single phase sensitive Pages non single phase sensitive Manual/hand or automatic reset Manual/hand Automatic Manual/hand Automatic reset reset reset reset BG06...BG2 RF9 RFA9 RFN9 RFNA9 3-2 and 3-3 BF09...BF38 RF38 RFN38 3-4...3-6 RFE45 3- BF40...BF80 RF82 RFA82 RFN82 RFNA82 3-5 and 3-7 RFE45 / RFE❶ 3- BF85...BF50 RF RFA RFN RFNA 3-4...3-7 RFE❶ 3- B5...B80 RF200 RFN200 B250...B400 RF400 RFN400 3-8 and 3-9 ❶ Independent mounting RFE

Page 3-2 Page 3-4 Page 3-8 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non phase failure sensitive, manual resetting Type RFNA9, non phase failure sensitive, automatic resetting. FOR BF SERIES CONTACTORS Type RF38, phase failure sensitive, manual or automatic resetting Type RFN38, non phase failure sensitive, manual or automatic resetting Type RF82 and RF95, phase failure sensitive, manual resetting Type RFA82 and RFA95, phase failure sensitive, automatic resetting Type RFN82 and RFN95, non phase failure sensitive, manual resetting Type RFNA82 and RFNA95, non phase failure sensitive, automatic resetting. FOR B SERIES CONTACTORS Type RF200 and RF420, phase failure sensitive, manual or automatic resetting Type RFN200 and RFN420, non phase failure sensitive, manual or automatic resetting. Page 3- ELECTRONIC THERMAL OVERLOAD RELAYS FOR BF SERIES CONTACTORS Phase failure sensitive, manual or automatic resetting Selectable tripping class: 5--20-30 High reliability and accuracy of tripping Minimal heat dissipation Wide current adjustment range. Page 3-2 THERMISTOR PROTECTION RELAY 24VDC and 24 to 240VAC supply types. LOVATO Electric motor protection relays are suitable for new motors with high IE3 efficiency values RF38 features FRONT PROTECTION COVER OF THERMAL OVERLOAD RELAYS A sealable protection cover is available. When fitted on to the relay front, it precludes all possible adjuster tampering and involuntary activation of the Reset and Stop buttons of the thermal overload relay. CLEAR IDENTIFICATION OF THERMAL OVERLOAD RELAY MANUAL OR AUTOMATIC RESETTING The RF38 thermal overload relay is supplied configured for manual resetting. Breaking the plate below the Reset button allows for the automatic resetting configuration. FIXING EASE OF THE THERMAL OVERLOAD RELAY While the thermal overload relay is being linked to the contactor, its auxiliary contact fits on and connects to the coil terminal by rigid terminal. Complete relay fixing is done in a single operation, with no need of other connections. SEALABLE RELAY COVER A handy closing flap feature excludes any tampering of the thermal overload relay adjuster.

Thermal overload relays for BG series mini-contactors Phase failure / single phase sensitive Three poles (three phase) RF9... RFA9... Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg K5 pkg [A] [A] [A] [A] n [kg] MANUAL RESETTING. Direct mounting on BG06, BG09, BG2 mini-contactors. RF9 05 0.09...0.5 0.25 0.6 RF9 023 0.4...0.23 0.5 0.6 RF9 033 0.2...0.33 0.5 0.6 RF9 05 0.3...0.5 2 3 0.6 RF9 075 0.45...0.75 2 3 0.6 RF9 0.6... 2 4 3 5 0.6 RF9 V5 0.9...5 2 4 6 5 0.6 RF9 2V3.4...2.3 4 6 5 0.6 RF9 33 2...3.3 4 5 0.6 RF9 5 3...5 6 6 5 5 0.6 RF9 75 4.5...7.5 8 20 25 5 0.6 RF9 6... 32 30 5 0.6 RF9 5 9...5 6 40 45 5 0.6 AUTOMATIC RESETTING. Direct mounting on BG06, BG09, BG2 mini-contactors. RFA9 05 0.09...0.5 0.25 0.6 RFA9 023 0.4...0.23 0.5 0.6 RFA9 033 0.2...0.33 0.5 0.6 RFA9 05 0.3...0.5 2 3 0.6 RFA9 075 0.45...0.75 2 3 0.6 RFA9 0.6... 2 4 3 0.6 RFA9 V5 0.9...5 2 4 6 0.6 RFA9 2V3.4...2.3 4 6 0.6 RFA9 33 2...3.3 4 0.6 RFA9 5 3...5 6 6 5 0.6 RFA9 75 4.5...7.5 8 20 25 0.6 RFA9 6... 32 30 0.6 RFA9 5 9...5 6 40 45 0.6 NOTE: Two-pole (single phase) versions are available on request. Add the letter S in the order code e.g. RF905 is three pole; RFS905 two pole. The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. Three-phase IEC motor powers ❶ 230V 400V 500V 690V [kw] [kw] [kw] [kw]] ❷ ❷ ❷ 0.06 ❷ 0.06 0.06 0.09 ❷ 0.09 0.09 0.2 0.06 0.2 0.2 0.8 0.09-0.2 0.8 0.8 0.25-0.37 0.2 0.25 0.25-0.37 0.55 0.8 0.37 0.55 0.75 0.25-0.37 0.55-0.75 0.75.-.5 0.55..-.5.5-2.2 0.75.5 2.2 3.-.5 2.2-3 3-4 4-5.5 2.2 4 4-5.5 7.5 3 5.5 7.5 ❷ ❷ ❷ 0.06 ❷ 0.06 0.06 0.09 ❷ 0.09 0.09 0.2 0.06 0.2 0.2 0.8 0.09-0.2 0.8 0.8 0.25-0.37 0.2 0.25 0.25-0.37 0.55 0.8 0.37 0.55 0.75 0.25-0.37 0.55-0.75 0.75.-.5 0.55..-.5.5-2.2 0.75.5 2.2 3.-.5 2.2-3 3-4 4-5.5 2.2 4 4-5.5 7.5 3 5.5 7.5 ❶ The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. ❷ No standard power ratings exist; select relay according to current consumption. NOTE: to facilitate connection between the auxiliary NC contact of the RF...9 thermal relay and terminal A2 of the contactor, insert the conductor into the appropriate conduit as shown. RF9... RFA9... Certifications obtained: c U L C E C u S A C Type s A C C RF9... - RFA9... Certified products. culus UL Listed for USA and Canada (culus - File E9360) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating; the trip current is 20% FLA. CSA CSA certified for Canada only (File 54332) as Auxiliary Devices for use with magnetic contactors. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-4-, UL 60947-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. 3-2 Accessories page 3- page 2-32 page 3-4 pages 3-5 and 6

Thermal overload relays for BG series mini-contactors Non phase failure / non single phase sensitive Three poles (three phase) RFN9... RFNA9... Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg K5 pkg [A] [A] [A] [A] n [kg] MANUAL RESETTING. Direct mounting on BG06, BG09, BG2 mini-contactors. RFN9 05 0.09...0.5 0.25 0.23 RFN9 023 0.4...0.23 0.5 0.23 RFN9 033 0.2...0.33 0.5 0.23 RFN9 05 0.3...0.5 2 3 0.23 RFN9 075 0.45...0.75 2 3 0.23 RFN9 0.6... 2 4 3 0.23 RFN9 V5 0.9...5 2 4 6 0.23 RFN9 2V3.4...2.3 4 6 0.23 RFN9 33 2...3.3 4 0.23 RFN9 5 3...5 6 6 5 0.23 RFN9 75 4.5...7.5 8 20 25 0.23 RFN9 6... 32 30 0.23 RFN9 5 9...5 6 40 45 0.23 AUTOMATIC RESETTING. Direct mounting on BG06, BG09, BG2 mini-contactors. RFNA9 05 0.09...0.5 0.25 0.23 RFNA9 023 0.4...0.23 0.5 0.23 RFNA9 033 0.2...0.33 0.5 0.23 RFNA9 05 0.3...0.5 2 3 0.23 RFNA9 075 0.45...0.75 2 3 0.23 RFNA9 0.6... 2 4 3 0.23 RFNA9 V5 0.9...5 2 4 6 0.23 RFNA9 2V3.4...2.3 4 6 0.23 RFNA9 33 2...3.3 4 0.23 RFNA9 5 3...5 6 6 5 0.23 RFNA9 75 4.5...7.5 8 20 25 0.23 RFNA9 6... 32 30 0.23 RFNA9 5 9...5 6 40 45 0.23 Three-phase IEC motor powers ❶ 230V 400V 500V 690V [kw] [kw] [kw] [kw]] ❷ ❷ ❷ 0.06 ❷ 0.06 0.06 0.09 ❷ 0.09 0.09 0.2 0.06 0.2 0.2 0.8 0.09-0.2 0.8 0.8 0.25-0.37 0.2 0.25 0.25-0.37 0.55 0.8 0.37 0.55 0.75 0.25-0.37 0.55-0.75 0.75.-.5 0.55..-.5.5-2.2 0.75.5 2.2 3.-.5 2.2-3 3-4 4-5.5 2.2 4 4-5.5 7.5 3 5.5 7.5 ❷ ❷ ❷ 0.06 ❷ 0.06 0.06 0.09 ❷ 0.09 0.09 0.2 0.06 0.2 0.2 0.8 0.09-0.2 0.8 0.8 0.25-0.37 0.2 0.25 0.25-0.37 0.55 0.8 0.37 0.55 0.75 0.25-0.37 0.55-0.75 0.75.-.5 0.55..-.5.5-2.2 0.75.5 2.2 3.-.5 2.2-3 3-4 4-5.5 2.2 4 4-5.5 7.5 3 5.5 7.5 3 NOTE: The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. ❶ The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. ❷ No standard power ratings exist; select relay according to current consumption. NOTE: to facilitate connection between the auxiliary NC contact of the RFN...9 thermal relay and terminal A2 of the contactor, insert the conductor into the appropriate conduit as shown. RFN9... RFNA9... Certifications obtained: c U L C E C u S A C Type s A C C RFN9... - RFNA9... Certified products. culus UL Listed for USA and Canada (culus - File E9360) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating; the trip current is 20% FLA. CSA CSA certified for Canada only (File 54332) as Auxiliary Devices for use with magnetic contactors. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-4-, UL 60947-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. Accessories page 3- page 2-32 page 3-4 pages 3-5 and 6 3-3

Thermal overload relays for BF series contactors Phase failure / single phase sensitive Three poles (three phase) RF38... Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg ❶ pkg [A] [A] [A] [A] n [kg] MANUAL OR AUTOMATIC RESETTING. Direct mounting on BF09...BF38 contactors. Independent mounting with RFX38 04 base. RF38 006 0...0.6 0.25 0.60 RF38 0025 0.6...0.25 0.5 0.60 RF38 0040 0.25...0.4 0.5 3 0.60 RF38 0063 0.4...0.63 2 3 0.60 RF38 00 0.63... 2 4 3 5 0.60 RF38 060...6 2 4 6 5 0.60 RF38 0250.6...2.5 4 6 5 0.60 RF38 0400 2.5...4 4 6 5 5 0.60 RF38 0650 4...6.5 8 6 25 5 0.60 RF38 00 6.3... 20 40 5 0.60 RF38 400 9...4 6 32 50 5 0.60 RF38 800 3...8 25 40 70 5 0.60 RF38 2300 7...23 25 50 90 5 0.60 RF38 2500 20...25 32 50 0 5 0.60 RF38 3200 24...32 40 63 20 0.60 RF38 3800 32...38 40 63 50 0.60 ❶ UL RK5 fuse class for RF38 types and UL K5 fuse class for RF 95 types. NOTE: Two pole (single phase) versions are available on request. Add the letter S in the order code e.g. RF3800 is three pole; RFS3800 two pole. The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. Three-phase IEC motor powers ❸ 230V 400V 500V 690V [kw] [kw] [kw] [kw] ❷ ❷ ❷ 0.06 ❷ 0.06 0.06-0.09 0.09-0.2 0.06 0.09 0.2 0.8 0.09 0.2-0.8 0.8 0.25 0.2 0.25 0.25-0.37 0.37-0.55 0.8-0.25 0.37-0.55 0.55-0.75 0.75 0.37 0.75..-.5 0.55-0.75.-.5.5-2.2 2.2-3.-.5 2.2 3 4.5-2.2 3-4 4-5.5 5.5-7.5 3 5.5 5.5-7.5 4 7.5 5 5.5 8.5 5.5 5 22 7.5 5 8.5 30 8.5 22 30 ❷ No standard powers ratings exist; select relay according to current consumption. ❸ The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. Certifications obtained: Register of c shipping U L L C E C R u S A C O Type s A C C S RF38 Certified products. culus UL Listed for USA and Canada (culus - File E9360) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating up to 82A FLA range and 000 Amps RMS for 95A and A FLA range; the trip current is 20% FLA. CSA CSA certified for Canada only (File 54332) as Auxiliary Devices for use with magnetic contactors. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-4-, UL 60947-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. FIXING EASE OF THE THERMAL OVERLOAD RELAY While the thermal overload relay is being linked to the contactor, its auxiliary contact fits on and connects to the coil terminal by rigid terminal. Complete relay fixing is done in a single operation, with no need of other connections. 3-4 Accessories page 3- page 2-32 and 2-33 page 3-4 pages 3-5 and 6

Thermal overload relays for BF series contactors Phase failure / single phase sensitive Three poles (three phase) RF82... RF... RFA82... RFA... new new Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg ❶ pkg [A] [A] [A] [A] n [kg] MANUAL RESETTING. Direct mounting on BF40...BF80 contactors. Independent mounting with G270 base. RF82 3300 20...33 40 63 0.365 RF82 4200 28...42 50 80 50 0.365 RF82 5000 35...50 50 0 75 0.365 RF82 6500 46...65 80 25 200 0.365 RF82 8200 60...82 0 200 250 0.365 MANUAL RESETTING. Direct mounting on BF85...BF50 contactors. Independent mounting with G270 base. RF 082 60...82 0 200 250 0.365 RF 095 70...95 0 200 350 0.365 RF 90... 25 200 350 0.365 AUTOMATIC RESETTING. Direct mounting on BF40...BF80 contactors. Independent mounting with G270 base. RFA82 3300 20...33 40 63 0.365 RFA82 4200 28...42 50 80 50 0.365 RFA82 5000 35...50 50 0 75 0.365 RFA82 6500 46...65 80 25 200 0.365 RFA82 8200 60...82 0 200 250 0.365 AUTOMATIC RESETTING. Direct mounting on BF85...BF50 contactors. Independent mounting with G270 base. RFA 082 60...82 0 200 250 0.365 RFA 095 70...95 0 200 350 0.365 RFA 90... 25 200 350 0.365 ❶ UL RK5 fuse class for RF38 types and UL K5 fuse class for RF 95 types. NOTE: Two pole (single phase) versions are available on request. Add the letter S in the order code e.g. RF828200 is three pole; RFS828200 two pole. The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. Three-phase IEC motor powers ❷ 230V 400V 500V 690V [kw] [kw] [kw] [kw] 7.5-5 5-8.5 22-25 9-5-8.5 22-25 30-33 - 22 30 37-40 5-8.5 25-30 33-40 45-55 22 33-40 45-55 59-75 22 33-40 45-55 59-75 22-25 40-45 55-63 75-80 30 55 75 90 7.5-5 5-8.5 22-25 9-5-8.5 22-25 30-33 - 22 30 37-40 5-8.5 25-30 33-40 45-55 22 33-40 45-55 59-75 22 33-40 45-55 59-75 22-25 40-45 55-63 75-80 30 55 75 90 ❷ The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range Certifications obtained: Register of c shipping U L L C E C R u S A C O Type s A C C S RF82 RFA82 RF ❸ RFA ❸ 3 Certified products. culus UL Listed for USA and Canada (culus - File E9360) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating up to 82A FLA range and 000 Amps RMS for 95A and A FLA range; the trip current is 20% FLA. CSA CSA certified for Canada only (File 54332) as Auxiliary Devices for use with magnetic contactors. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-4-, UL 60947-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. ❸ culus pending. FIXING EASE OF THE THERMAL OVERLOAD RELAY While the thermal overload relay is being linked to the contactor, its auxiliary contact fits on and connects to the coil terminal by rigid terminal. Complete relay fixing is done in a single operation, with no need of other connections. Accessories page 3- page 2-32 and 2-33 page 3-4 pages 3-5 and 6 3-5

Thermal overload relays for BF series contactors Non phase failure / non single phase sensitive Three poles (three phase) RFN38... Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg ❶ pkg [A] [A] [A] [A] n [kg] MANUAL OR AUTOMATIC RESETTING. Direct mounting on BF09...BF38 contactors. Independent mounting with RFX38 04 base. RFN38 006 0...0.6 0.25 0.60 RFN38 0025 0.6...0.25 0.5 0.60 RFN38 0040 0.25...0.4 0.5 3 0.60 RFN38 0063 0.4...0.63 2 3 0.60 RFN38 00 0.63... 2 4 3 0.60 RFN38 060...6 2 4 6 0.60 RFN38 0250.6...2.5 4 6 0.60 RFN38 0400 2.5...4 4 6 5 0.60 RFN38 0650 4...6.5 8 6 25 0.60 RFN38 00 6.3... 20 40 0.60 RFN38 400 9...4 6 32 50 0.60 RFN38 800 3...8 25 40 70 0.60 RFN38 2300 7...23 25 50 90 0.60 RFN38 2500 20...25 32 50 0 0.60 RFN38 3200 24...32 40 63 25 0.60 RFN38 3800 32...38 40 63 50 0.60 ❶ UL RK5 fuse class for RFN38 types and UL K5 fuse class for RF 95 types. NOTE: The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. Three-phase IEC motor powers ❸ 230V 400V 500V 690V [kw] [kw] [kw] [kw] ❷ ❷ ❷ 0.06 ❷ 0.06 0.06-0.09 0.09-0.2 0.06 0.09 0.2 0.8 0.09 0.2-0.8 0.8 0.25 0.2 0.25 0.25-0.37 0.37-0.55 0.8-0.25 0.37-0.55 0.55-0.75 0.75 0.37 0.75..-.5 0.55-0.75.-.5.5-2.2 2.2-3.-.5 2.2 3 4.5-2.2 3-4 4-5.5 5.5-7.5 3 5.5 5.5-7.5 4 7.5 5 5.5 8.5 5.5 5 22 7.5 5 8.5 30 8.5 22 30 ❷ No standard power ratings exist; select relay according to current consumption. ❸ The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. Certifications obtained: c U L C E C u S A C Type s A C C RFN38 Certified products. culus UL Listed for USA and Canada (culus - File E9360) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating up to 82A FLA range and 000 Amps RMS for 95A and A FLA range; the trip current is 20% FLA. CSA CSA certified for Canada only (File 54332) as Auxiliary Devices for use with magnetic contactors. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-4-, UL 60947-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. FIXING EASE OF THE THERMAL OVERLOAD RELAY While the thermal overload relay is being linked to the contactor, its auxiliary contact fits on and connects to the coil terminal by rigid terminal. Complete relay fixing is done in a single operation, with no need of other connections. 3-6 Accessories page 3- page 2-32 and 2-33 page 3-4 pages 3-5 and 6

Thermal overload relays for BF series contactors Non phase failure / non single phase sensitive Three poles (three phase) RFN82... RFN... RFNA82... new new Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg ❶ pkg [A] [A] [A] [A] n [kg] MANUAL RESETTING. Direct mounting on BF40...BF80 contactors. Independent mounting with G270 base. RFN82 4200 28...42 50 80 50 0.365 RFN82 5000 35...50 50 0 75 0.365 RFN82 6500 46...65 80 25 200 0.365 RFN82 8200 60...82 0 200 250 0.365 MANUAL RESETTING. Direct mounting on BF85...BF50 contactors. Independent mounting with G270 base. RFN 082 60...82 0 200 250 0.365 RFN 095 70...95 0 200 350 0.365 RFN 90... 25 200 350 0.365 AUTOMATIC RESETTING. Direct mounting on BF40...BF80 contactors. Independent mounting with G270 base. RFNA82 4200 28...42 50 80 50 0.365 RFNA82 5000 35...50 50 0 75 0.365 RFNA82 6500 46...65 80 25 200 0.365 RFNA82 8200 60...82 0 200 250 0.365 AUTOMATIC RESETTING. Direct mounting on BF85...BF50 contactors. Independent mounting with G270 base. RFNA 082 60...82 0 200 250 0.365 RFNA 095 70...95 0 200 350 0.365 RFNA 90... 25 200 350 0.365 ❶ UL RK5 fuse class for RFN38 types and UL K5 fuse class for RF 95 types. NOTE: The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. Three-phase IEC motor powers ❷ 230V 400V 500V 690V [kw] [kw] [kw] [kw] 9-5-8.5 22-25 30-33 - 22 30 37-40 5-8.5 25-30 33-40 45-55 22 33-40 45-55 59-75 22 33-40 45-55 59-75 22-25 40-45 55-63 75-80 30 55 75 90 9-5-8.5 22-25 30-33 - 22 30 37-40 5-8.5 25-30 33-40 45-55 22 33-40 45-55 59-75 22 33-40 45-55 59-75 22-25 40-45 55-63 75-80 30 55 75 90 ❷ The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. Certifications obtained: c U L C E C u S A C Type s A C C RFN82 RFNA82 RFN ❸ RFNA ❸ 3 Certified products. RFNA... culus UL Listed for USA and Canada (culus - File E9360) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating up to 82A FLA range and 000 Amps RMS for 95A and A FLA range; the trip current is 20% FLA. CSA CSA certified for Canada only (File 54332) as Auxiliary Devices for use with magnetic contactors. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-4-, UL 60947-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. ❸ culus pending. FIXING EASE OF THE THERMAL OVERLOAD RELAY While the thermal overload relay is being linked to the contactor, its auxiliary contact fits on and connects to the coil terminal by rigid terminal. Complete relay fixing is done in a single operation, with no need of other connections. Accessories page 3- page 2-32 and 2-33 page 3-4 pages 3-5 and 6 3-7

Thermal overload relays for B series contactors Phase failure / single phase sensitive Three poles (three phase) RF200... - RF420... Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg K5 pkg [A] [A] [A] [A] n [kg] MANUAL OR AUTOMATIC RESETTING. Independent screw fixing or direct mounting on contactors: B45-B80 using G372 links. B250-B3-B400 using G373 links. RF200 0 60...0 0 60 500 2.50 RF200 25 75...25 25 200 500 2.50 RF200 50 90...50 60 250 500 2.50 RF200 200 20...200 200 35 500 2.50 Independent screw fixing or direct mounting on contactors: B45-B80 using G375 links B250-B3-B400 using G376 links RF420 250 50...250 250 400 800 2.460 RF420 300 80...300 35 500 800 2.460 RF420 420 250...420 500 630 800 2.460 NOTE: The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. Three-phase IEC motor powers ❶ 230V 400V 550V 690V [kw] [kw] [kw] [kw] 8.5-25 33-5 45-63 59-92 22-37 40-63 55-80 75-25-45 5-80 63-0 92-40 37-59 75-0 92-40 29-84 45-75 92-32 -62 40-220 55-92 0-62 29-98 80-280 75-29-98 80-280 250-368 NOTE: For 00V powers, consult Technical support for information; see contact details on inside front cover. ❶ The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment B45...B400 G372 G373 G375 G376 RELAYS FOR B500 AND B630 CONTACTORS MANUAL OR AUTOMATIC RESETTING. Consult Technical support for the relative order codes and detailed information; see contact details on inside front cover. Certifications obtained: c U L E u A Type s C RF200 RF420 Certified products. culus UL Listed for USA and Canada (culus - File E9360) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating up to 50A FLA range, 000 Amps RMS for 200A up to 300A FLA range and 8000 Amps for the 420A; the trip current is 20% FLA. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-4-, UL 60947-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. RF200 RF420 3-8 Accessories page 3- page 2-34 and 2-35 page 3-4 pages 3-5 and 6

Thermal overload relays for B series contactors Non phase failure / non single phase sensitive Three poles (three phase) RFN200... - RFN420... Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg K5 pkg [A] [A] [A] [A] n [kg] MANUAL OR AUTOMATIC RESETTING. Independent screw fixing or direct mounting on contactors: B45-B80 using G372 links. B250-B3-B400 using G373 links. RFN200 0 60...0 0 60 500 2.50 RFN200 25 75...25 25 200 500 2.50 RFN200 50 90...50 60 250 500 2.50 RFN200 200 20...200 200 35 500 2.50 Independent screw fixing or direct mounting on contactors: B45-B80 using G375 links. B250-B3-B400 using G376 links. RFN420 250 50...250 250 400 800 2.460 RFN420 300 80...300 35 500 800 2.460 RFN420 420 250...420 500 630 800 2.460 NOTE: The appropriate adjustment range of the overload relay should be selected on the basis of the motor nameplate full-load current when direct, across the line starting is considered. Three-phase IEC motor powers ❶ 230V 400V 550V 690V [kw] [kw] [kw] [kw] 8.5-25 33-5 45-63 59-92 22-37 40-63 55-80 75-25-45 5-80 63-0 92-40 37-59 75-0 92-40 29-84 45-75 92-32 -62 40-220 55-92 0-62 29-98 80-280 75-29-98 80-280 250-368 NOTE: For 00V powers, consult Technical support for information; see contact details on inside front cover. ❶ The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. 3 B45...B400 RELAYS FOR B500 AND B630 CONTACTORS. MANUAL OR AUTOMATIC RESETTING. Consult Technical support for the relative order codes and detailed information; see contact details on inside front cover. Certifications obtained: c U L E u A Type s C RFN200 RFN420 G372 G373 G375 G376 Certified products. culus UL Listed for USA and Canada (culus - File E9360) as Auxiliary Devices Thermal Overload Relays, 600VAC, open type, ambient compensated, 5000 Amps RMS symmetrical short circuit rating up to 50A FLA range, 000 Amps RMS for 200A up to 300A FLA range and 8000 Amps for the 420A; the trip current is 20% FLA. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-4-, UL 60947-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. RFN200 RFN420 Accessories page 3- page 2-34 and 2-35 page 3-4 pages 3-5 and 6 3-9

Add-on blocks and accessories for thermal overload relays RFX38 02 RFX38 03 RFX38 04 Order code For relay Qty Wt per pkg n [kg] Set of links for direct contactor mounting. G372 RF...200 on B45-B80 0.250 G373 contactor B250-B3-B400 0.360 G375 RF...420 on B45-B80 0.33 G376 contactor B250-B3-B400 0.500 Protection cover for thermal overload relay-contactor assembly. RFX38 02 RF38 on contactor BF09-0.04 BF2-BF8-BF25 RFX38 03 RF38 on contactor BF26-0.04 BF32-BF38 Protection shrouds for power terminals. G36 RF...200 6 0.026 G363 RF...420 6 0.046 Independent mounting. Screw fixing or 35mm DIN rail (IEC/EN 6075) mounting. RFX38 04 RF...38 5 0.082 G270❷ RF...82 - RF... 0.48 Electrical reset. G228❸ RF...9 - RF...82 - RF... 5 0.072 Sealing device. RFX38 0 RF...38 - RF...200 - RF...420 0.002 G233 RF...9 - RF...82 - RF... 0.006 ❶ Front IP20 protection is warranted to contactor-thermal relay connections. ❷ Independent mounting base for any RF95 relay. Remove the links fixed on RF...95 and use those supplied with the base. ❸ Replace with voltage digit. Standard voltages are: AC 50/60Hz 24V / 48V / -25V / 220-240V / 380-45V. ❹ Replace with the required alphanumeric symbol. Each package contains 0 pieces of the same symbol. Operational characteristics ELECTRICAL RESET G228 Control circuit voltage AC (50/60Hz) V 2...550 Power consumption in AC VA 300 Minimum reset time ms 20 Terminals Faston 6.3x0.8 NOTE: Coils can remain supplied for a maximum interval of 500ms; 3 consecutive operations are allowed, followed by a 5 minute interval. Reset only if at least min has passed from overload tripping. It is recommended to use the wiring diagram on page 3-4. INDEPENDENT MOUNTING Conductor cross section with one cable: 6...mm 2 / AWG 8 for RFX38 04 35mm 2 / AWG 2 for G270 Tightening torque: 2...2.5Nm /.5...8lbft for RFX38 04 3.9Nm / 2.88lbft for G270. Certifications obtained: c U L C E u S A Type s A C G36-G363-G372-G373-G375-G376 G270 RFX38 04 Certified products. culus UL Listed for USA and Canada (culus - File E9360) as Auxiliary Devices for thermal overload relays. CSA CSA certified for Canada only (File 54332) as Kits for industrial control equipment. Compliant with standards: IEC/EN 60947-, IEC/EN 60947-4-, UL 60947-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. G228 Combinations G372 G373 G375 G376 G270 G36 G363 RF...200 RF...420 RFX38 0 RFX38 04 RF...82 RF... G233 G228 RF...9 RF...38 RFX38 0 Protection cover for thermal overload relay-contactor assembly BF09...BF25 BF26...BF38 RFX38 02 RFX38 03 RF...38 RF...38 3- page 3-3 page 3-4 pages 3-5 and 6

Electronic thermal overload relays for BF series contactors Phase failure / single phase sensitive Three poles (three phase) RFE45... new Order code Adjustment Protection fuses Qty Wt range IEC UL per am gg Class pkg T [A] [A] [A] [A] n [kg] MANUAL OR AUTOMATIC RESETTING. Direct mounting on BF09...BF38 contactors. Independent mounting with RFX38 04. RFE45 0200 0.4...2 4 6 25 0.95 RFE45 0800.6...8 20 25 0.95 RFE45 3200 6.4...32 40 63 25 0.95 MANUAL OR AUTOMATIC RESETTING. Independent mounting. RFE 22... 25 200 300 0.6 Three-phase IEC motor powers ❶ 230V 400V 500V 690V [kw] [kw] [kw] [kw] 0.09...0.37 0.2...0.75 0.8...0.75 0.25... 0.37...0.55 0.75...3...4...5.5 2.2...7.5 3...5 6.8...28 5.5...30 7.5...30...55 5...75 22...90 ❶ The indicated powers apply to 4-pole motors; it is advisable to always check that the nameplate motor current is within the relay adjustment range. 3 General characteristics The RFE electronic thermal overload relays for BF series contactors are characterized by a wide current adjustment range and high reliability and accuracy of tripping. They are self powered by the main circuit current and therefore do not require separate auxiliary supply voltage. RFE electronic thermal overload relays are suitable for all types of motor starting thanks to the possibility to select several tripping classes. A single front push button is used to select the reset function, manual or automatic, and to activate or deactivate the STOP function. RFE Operational characteristics IEC power circuit rated insulation voltage Ui: 00V IEC auxiliary circuit rated insulation voltage Ui: 690V rated impulse withstand voltage: 8kV rated frequency: 50/60Hz maximum rated current: 32A for RFE45, A for RFE heat dissipation per phase: <W selectable tripping classes: 5--20-30 phase failure sensitive mounting position: any sealable current adjuster and dip switches for tripping class selection degree of protection: IP20 on front. Certifications obtained: culus. Compliant with standards: IEC/EN 60947-; IEC/EN 60947-4-, UL 60947-, UL 60947-4-, CSA C22.2 n 60947-, CSA C22.2 n 60947-4-. Accessories page 3- page 2-32 and 2-33 page 3-4 3-

Thermistor protection relays Thermistor protection relays 3 DRPT... Order code Rated auxiliary Qty Wt. supply voltage per pkg [V] n [kg] DC supply (version for 35mm DIN rail IEC/EN 6075). 3 DRPTC 24 24VDC❶ 0.269 AC supply (version for 35mm DIN rail IEC/EN 6075). 3 DRPT 24 24VAC 0.269 3 DRPT VAC 0.269 3 DRPT 220 220...240VAC 0.269 Accessories. Order code Description Qty Wt per pkg n [kg] 3 CE6 Adapter for screw 0.008 fixing of DRPT relay on mounting plate. ❶ Galvanic isolation between supply and measuring circuits does not exist. General characteristics The DRPT is a thermal protection relay for motors equipped with thermistor PTC sensors immersed in the winding heads. The maximum number of thermistors to be used is limited by the resistance of all the sensors connected in series; total ohmic value is not to exceed.5kω at 25 C. The DRPT type has fail-safe operation: the protective feature trips even in the case the PTC circuit is disconnected or there is a lack of voltage. Resetting is manual or automatic. Operational characteristics Supply circuit: Rated frequency: 50-60Hz for AC types only Operational limits: 0.85... Us Maximum dissipation: 2.5W Connection: permanent Measuring circuit: Type of connectable PTC sensor: According to DIN 4408 Total PTC resistance at 25 C:.5kΩ Tripping resistance: 2.7...3.kΩ Resetting resistance:.5...8kω Voltage at PTC terminals: 2.5VDC Remote resetting: Control: NC contact opening Contact voltage: 5VDC Current consumption: about ma Relay output: Arrangement: relay with 2 changeover contacts Rated operational voltage Ue: 250VAC Conventional free air thermal current Ith: 5A Designation to IEC/EN 60947-5-: B300 Mechanical life: 50x 6 cycles Electrical life (with rated load): 2x 5 cycles Indications: Green LED indicator for power ON Red LED indicator for relay state TRIP Connections: Conductor section 2x.5mm 2 with ferrule (max) Tightening torque: 0.8-.2Nm Ambient conditions: Operating temperature: -...+60 C Storage temperature: -30...+80 C Housing: Snap on 35mm DIN rail (IEC/EN 6075) For screw fixing, use CE6 adapter Degree of protection IP40 housing IP20 terminals. Certifications obtained: EAC. Compliant with standards: IEC/EN 60255-5. 3-2 page 3-3 page 3-4

[mm (in)] ACCESSORIES FOR THERMAL OVERLOAD RELAYS RFX38 04 base c/w RF...38 thermal relay 7.9 (0.3 ) 45 (.77 ) 4.6 (0.57 ) 70.3 (2.77 ) 34 (.34 ) Ø4.2 (0.6 ) 73.5 (2.89 ) 88.4 (3.48 ) 83 (3.27 ) G270 base c/w RF...82 and RF... thermal relay 9.7 (0.38 ) 55 (2.6 ) 6.5 (0.65 ) 79 (3. ) 43 (.69 ) Ø4.2 (0.6 ) 85 (3.35 ) 2 (4.0 ) 95.4 (3.75 ) 3 7.9 (0.3 ) 4.6 (0.57 ) THERMAL RELAYS WITH LINKS RF...200 with G372 and G373 (0.43 ) 6.5 (0.65 ) 23.8 (0.94 ) 27.5 (5.02 ) 40 (.57 ) 40 (.57 ) 66. (6.54 ) 22 (4.80 ) G372 G373 3.4 (4.46 ) 72 (6.77 ) 38.6 (.52 ) Ø5.4 (0.2 ) 74 (2.9 ) 20 (0.79 ) 40 (.57 ) 40 (.57 ) RF...420 with G375 and G376 25 (0.98 ) 45 (5.7 ) 47.5 (.57 ) M8 47.5 (.57 ) 56.5 (2.22 ) 65.4 (6.5 ) 53.3 (6.03 ) G375 G376 Ø5.4 (0.2 ) 2.2 (4.77 ) 74 (2.9 ) 89.6 (7.46 ) 44.8 (.76 ) 25 (0.98 ) 47.5 (.57 ) 47.5 (.57 ) M 56.8 (2.24 ) ADD-ON BLOCKS FOR THERMAL OVERLOAD RELAYS RF...9, RF...82 and RF... G228... reset ELECTRONIC THERMAL OVERLOAD RELAYS RFE45 45 (.77 ) 83.5 (3.29 ) RFE 65 (2.56 ) 50 (.97 ) 9 (0.75 ) 35.8 (.4 ) 3.3 (0.52 ) 35.8 (.4 ) 80 (3.5 ) 90 (3.54 ) 8.5 (3.2 ) Ø5,5 (0.22 ) (4.33 ) 20 (4.72 ) 5.5 (2.03 ) 4 (4.49 ) THERMISTOR PROTECTION RELAYS DRPT 45 (.77 ) 0 (3.94 ) CE6 adapter 22.5 (0.88 ) (0.39 ) 79 (3. ) 84 (3.30 ) 94 (3.70 ) Ø4.5 (0.8 ) 3-3

THERMAL OVERLOAD RELAYS FOR BG MINI-CONTACTORS RF9 - RFN9 95 97 TEST RESET L L2 L3 3 5 RFA9 - RFNA9 95 97 TEST L L2 L3 3 5 96 98 2 4 6 T T2 T3 96 98 2 4 6 T T2 T3 THERMAL OVERLOAD RELAYS FOR BF CONTACTORS RF38 - RFN38 95 STOP 97 TEST RESET L L2 L3 3 5 RF82 - RFN82 - RF - RFN 95 97 TEST RESET L L2 L3 3 5 RFA82 - RFNA82 - RFA - RFNA 95 97 TEST L L2 L3 3 5 96 98 2 4 6 T T2 T3 96 98 2 4 6 T T2 T3 96 98 2 4 6 T T2 T3 THERMAL OVERLOAD RELAYS FOR B CONTACTORS RF200 - RFN200 RF420 - RFN420 95 STOP 97 TEST RESET 3 5 L L2 L3 3 5 ADD-ON BLOCKS FOR THERMAL OVERLOAD RELAYS RF9 - RF Electric reset G228 L L2 L3 A 3 BF... A2 2 4 5 6 96 98 2 4 6 R TEST RESET 2 4 6 T T2 T3 E G228... 95 97 3 5 E2 96 98 RF... 2 4 6 L L T T2 T3 ELECTRONIC THERMAL OVERLOAD RELAYS RFE45 - RFE 95 STOP 97 TEST RESET L L2 L3 3 5 96 98 2 4 6 T T2 T3 THERMISTOR PROTECTION RELAYS DRPT L L2 L3 24VDC 24VAC VAC 220...240VAC Remote reset F2 S Set point Hysteresis C A A2 Automatic Reset Manual Reset Remote Reset F TEST 3 5 A T T2 S 2 RESET K K T2 S 2 4 6 A2 DRPT 2 4 22 24 ON S2 TRIP M S3 K 2 4 Rmax =.5kΩ (25 C) K 2 22 24 3-4

Phase failure/single phase sensitive manual reset RF9 RF38❶ RF82-RF RFE45 RFE RF200❶ RF420❶ Phase failure sensitive automatic reset RFA9 RFN38❶ RFA82-RFA RFN200❶ RFN420❶ Non phase failure/non single phase sensitive manual reset RFN9 RFN82-RFN Non phase failure/non single phase sensitive automatic reset RFNA9 RFNA82-RFNA POWER CIRCUIT CHARACTERISTICS IEC rated insulation voltage Ui V 690 690 690 00 00 00 00 IEC rated impulse withstand voltage Uimp kv 8 6 8 6 6 6 6 Frequency limit Hz 0...400 0...400 0...400 50...60 50...60 50...60 50...60 Operational range from A 0.09 0. 4 0.4 22 60 50 to A 5 38 82 32 200 420 ❷ Tripping class A 5--20-30 A Particular characteristics Test button - Trip indicator Connection Direct With current transformers ❸ Yoke Screw and Yoke Terminals Type Screw and washer clamp washer clamp Screw and flat washer Screw M4 M4 M5 M4 M6 M8 M Terminal width mm 9.8 2.6 9 2 9 20 25 Phillips n 2 2 2 2 4❻ 3mm❹ 8mm❹ Tightening torque Nm 2.3 2...2.5 3.9 3. 9 8 35 for power terminals lbft.7.5...8 2.88 2.3 6.6 3.3 25.9 3 Maximum conductor section connectable AWG N 8 2 6 /0 -- -- Flexible w/o lug mm 2 6 35 6 -- -- Flexible c/w lug mm 2 6 -- 6 50 2 x 50 Bar mm -- -- -- -- -- 25 x 3 30 x 5 Dissipation per phase W 0.7...2.4 0.7...2.4 2.0...4.2 < < 0.7...2.4 0.7...2.4 AUXILIARY CIRCUIT CHARACTERISTICS Available NO N contacts NC N IEC rated insulation voltage V 690 IEC conventional free air A 5 thermal current Ith Terminals with Screw M3.5 screw and washer Terminal width mm 8 7 8 Phillips n 2 2 2 2 2 Maximum conductor section connectable Flexible w/o lug mm 2 2.5 Flexible c/w lug mm 2 2.5 Tightening torque Nm 0.8... 0.8 0.8 0.8... 0.8... for auxiliary terminals lbft 0.74 0.59...0.74 0.74 0.6 0.6 0.59...0.74 0.59...0.74 UL/CSA and IEC/EN 60947-5- designation B600-P600 B600-R300 B600-P600 B600-R300 B600-R300 B600-R300 B600-R300 ❺ ❺ AMBIENT CONDITIONS Operating temperature C -20...+55-25...+60-20...+55-25...+70-25...+70-25...+60-25...+60 Storage temperature C -55...+70-50...+70-55...+70-55...+80-55...+80-50...+70-50...+70 Compensation temperature C -5...+55-20...+60-5...+55-25...+70-25...+70-20...+60-20...+60 Maximum altitude m 3000 Operation position normal On vertical plane Allowable ±30 Mounting On contactor or separately (RFE separately only) ❶ With manual and automatic resetting. ❷ For currents higher than 420A, consult Technical support for information; see contact details on inside front cover. ❸ Standard supplied. ❹ Metric wrench/spanner. ❺ C600-R300 for automatic reset type. ❻ Allen key. 3-5

TRIP CHARACTERISTIC FOR RF THERMAL OVERLOAD RELAYS (AVERAGE TIME) Three-phase balanced operation RF9 RF38 RF82 RF RFA9 RFN38 RFA82 RFA RFN9 RFN82 RFN RFNA9 RFNA82 RFNA Opening time [s] 000 2h Two-phase operation (phase failure/single phase) RF9 RF38 RF82 RFA RFA9 RFA82 RFNA Opening time [s] 000 2h h h 30min 00 min 30min 00 min 5min 5min 2min 0 2min 0 min COLD min COLD HOT HOT.05.2.5 2 3 4 5 6 7 8 9 x Ie [A].5.5 2 3 4 5 6 7 8 9 x Ie [A] RF200 RFN200 RF420 RFN420 RF200 RF420 Opening time [s] 000 2h Opening time [s] 000 2h h h 30min 30min 00 00 min min 5min 5min 2min 0 2min 0 COLD min min COLD HOT HOT.05.2.5 2 3 4 5 6 7 8 9 x Ie [A].5.5 2 3 4 5 6 7 8 9 x Ie [A] Tripping times can have a ±20% deviation with respect to the average tripping curve values above. 3-6

TRIP CHARACTERISTIC FOR RFE ELECTRONIC THERMAL OVERLOAD RELAYS Three-phase balanced operation; class 5 Three-phase balanced operation; class RFE45 RFE Operating time [s] 000 2h RFE45 RFE Operating time [s] 000 2h 3 h h 30min 30min 00 min 00 min 5min 5min 2min 0 2min 0 min COLD min COLD HOT HOT.05.2.5 2 3 4 5 6 7 8 9 x Ie [A].05.2.5 2 3 4 5 6 7 8 9 x Ie [A] Three-phase balanced operation; class 20 Three-phase balanced operation; class 30 RFE45 RFE RFE45 RFE Operating time [s] 000 2h Operating time [s] 000 2h h h 30min 30min 00 00 min min 5min 5min 2min 0 COLD 2min 0 COLD min min HOT HOT.05.2.5 2 3 4 5 6 7 8 9 x Ie [A].05.2.5 2 3 4 5 6 7 8 9 x Ie [A] 3-7