Ultrasonic Level Meter. Instruction Manual

Similar documents
Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

MH-A UNIVERSAL ULTRASONIC (LIQUID) LEVEL METER

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual

E2Q4 Square Proximity Sensor

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length (overall length) material

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

OPERATION MANUAL MODEL TT-LP

Series ULT Ultrasonic Level Transmitter

Manual of Electrical Installation for Pressure Probes KS and KS-SIL2 series

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

E4PA. Ultrasonic Displacement Sensor. Ordering Information

LPG STM 94442A User s Manual

Please read this manual attentively before installation

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to Installation and Operation of This Product.

Environdata FA ma Converter Guide

CDD4 Duct Carbon Dioxide Transmitter

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

ZMICROFLEX-C ULTRASONIC LEVEL TRANSMITTER

Operating Instructions for Digital Thermometers. Model: DTM

NFC110. Flow Computer For Low Pulses FEATURES

HL Series Ultrasonic Level Meter

Quick Guide. FW ver: ( )

USER MANUAL. WBV412U01 AC voltage transducer

User Manual. PCKeypad Wireless Keypad

METER Ultrasonic level transmitter

HGM9580 Bus Tie Bus Parallel Unit USER MANUAL. Smartgen Technology

F1000 User's Manual. (Version: V1.01)

PRO-1250D CT MID DIN rail three phase four wire energy meter.

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

Hybrid AC Driver [GCNC-1110]

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

ULTRASONIC LEVEL METERS ULM 53L

ULTRASONIC. Proximity Sensors. Series UX micro. Key-Features:

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

Programmable transmitter of temperature, relative humidity and other derived humidity values with 0 to 10 V outputs Instruction Manual

Electrical Motor Controls. Chapter 11 (4 th Edition) Chapter 6 (5 th Edition)

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

CAPVEL-LP : User Manual & Datasheet Contact level transmitter based on capacitance measurement

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

SF200. Installation Guide & Quick Start Guide. 2 TFT AC Terminal Version: 1.0 Date: June 2014

Ultrasound Controller DP36 Level Switch PSF Manual

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

USER MANUAL. Specifications. 0.1 m/s for wind speed degrees for wind direction -30 C to +80 C for temperature

PRO1250D CT M-bus MID DIN rail three phase four wire energy meter. User manual Version 1.11

F11 Installation Guide. Version: 1.0 Date: Jul. 2010

E2K-X4ME1 2M E2K-X4ME2 2M

GFC114. Low Power Flow Computer FEATURES

60 Ghz - Radar filling level sensor RFM 2000 C4 / R / MD

User Manual. 2.2KW/7.5KW/11KW Solar Inverter for Water Pump. Version: 1.8

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

Series Pressure Sensor Instruction Sheet

Suitable for detecting transparent films or transparent bottles

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

User Manual. Solar Inverter for Water Pump

TC22/23/24/25 Capacitance level transmitter - electronic preamplifi er

Intelligent Speed Dome Installation Manual. Version 1.0.0

MOTOR ARMATURE TESTER

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

iface Series Installation Guide

CT-510. Multifunctional CCTV Tester. User Manual

LT-200 Controller Manual 1 / 8. LT-200 Controller. (Version V5.00) Manual. ( Please kindly read this manual carefully before use.)

TRANSDUCER T4311, T4411

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

DVB-S/S2 to IP UDP/MPTS Gateway User Manual

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

5.6" Multi-function Monitor

CDD Carbon Dioxide Transmitter

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

T2214. Instruction Manual

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

TTC Series Torque Tool Tester Operation Manual

Mini Photoelectric Sensor

PRO1 V21.xxx series MID DIN rail single phase two wire energy meter

Manual

User's Guide. MiniTec TM Series Model MN25 MultiMeter

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

Thread length (overall length)

ATS CONTROLLER OPERATING MANUAL

TEMPERATURE AND HUMIDITY TRANSDUCER P18 TYPE USER S MANUAL

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

RS-FS-N01 Wind speed transmitter user's Guide (485type)

ToughSonic Distance Sensors

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

Installation Instructions for the ISSUE 3 RDS-DIN1 Series Single Channel Interface Module PK 80103

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Global Water Instrumentation, Inc.

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

OPERATION MANUAL (Web Site Downloaded only)

Stand-alone Proximity Access Control

Installation and Operation

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

IR Intelligent Speed Dome Installation Manual. Version 1.1.0

Cảm ơn các bạn đã tham khảo tài liệu cân điện tử từ CÂN ĐIỆN TỬ GIA PHÁT!

Transcription:

Ultrasonic Level Meter Instruction Manual

CONTENS I.General information..1 II. Characteristics...1 III. Specifications.....2 IV. Menu operation and setting... 2 V. Installation and precaution...4 VI. Wiring diagrams....7 VII. Trouble shooting....9 Manufacturer Certificate...11 Guarantee log...12

Ⅰ. General information Ultrasonic level measuring instrument, taking the advantages of various many level measuring instruments, is a universal one characterized by total digitalized and humanized design. It has perfect level monitoring, data transmission and man-machine communication. It is featured by strong anti-interference performance; free setting of upper and lower limits and online output regulation, on-site indication, optional analog, switching value, and RS485 output and easy connection with main unit. The cover, made of waterproof engineering plastics, is small and firm with ABS probe. Therefore, it is applicable for various fields concerning level measuring and monitoring. According to the practical situation, it also can add other modules, such as RS 485, current output; it can be match with PLC better. II. Characteristics DC12-24V wide work voltage Backup and recovery parameter set Free adjustment of the range of analog output Set a filter value to remove Custom serial port data format Optional increment/difference distance measurement to measure air space or liquid level 1-15 transmitted pulse intensity depending on working conditions More choices depend on your requirement, as bellowing: 3 NPN output 2 relay output Voltage output RS485output connect with PC Explosion-proof 1

III. Specifications Range:8m Blind zone:<0.3m Measure error: 0.3%F.S Display: LED or LCD Display resolution:1mm Frequency::20~350KHz Power: 12-24VDC Power consumption:<1.5w Output (optional): 4~20mA RL>600Ω(standard) 1~5V\1~10V RS485 3 NPN 2 relays (AC: 5A 250V DC: 10A 24V) Material:ABS Installation:G1 1/2(M47mm) Electrical interface:pg7 Admission cable:1.5m Operating surroundings:normal temperature, normal pressure Protection degree:ip65(others optional) IV. Menu operation and parameters setting 4.1 Keys function (A) (1.1)normal work / menu:enter password. ( 1.2 ) menu interface : page down or back, Long press back to normal work. (1.3)input/ confirm: Confirm input data and exit this menu. 2

(B)(2.1)menu interface: Enter or input. (2.2)input/shift:Shift cursor to right. (C)(3.1)menu interface: page up. (3.2)input interface/add:from 0~9,minus, decimal. 4.2 Setting Enter password interface or data input mode, press B to shift right, press C to choose number or symbol then press A to confirm. Under measuring interface, presses A to display password, default: 0000.press A to confirm, enter menu interface. 4.3 Menu instruction Menu, code and its meaning BD.11 : Ins. Ht, measures liquid level, it s the distance from sensor to tank bottom. Measures air space level, the value is 0. ST.15 : Filter, filter times in fix time, 0-100.the bigger, the more stable; the smaller, the quicker response. PL.25:PUL,transmitted intensity. PA.36:Password,password for menu:0000. F0.44:F0,start point of output::4ma. FS.45:FS,end point of output:20ma. DR.49:Add.,serial port address: 0-255. BP.50:Bdr.,serial port baud rate: 600-38400. 1L.54:No.1 D,No.1 switch output D. 1H.55:No.1 H,No.1 switch output H. 2L.56:No. 2 D,No.2 switch output D. 2H.57:No.2 H,No.2 switch output H. 3L.58:No.3 D,No.3 switch output D. 3H.59:No.3 H,No.3 switch output H. 4.4 Adjusting The method of adjusting the proportion of light column of the complete instrument: 3

First long press SET key for 3 seconds, when displaying AH, then press the up key, it will display PS55, and then press once SET, 0 will flash, and then press the up key to change 0 into 5, and then press right shift key in the lower part of the instrument, and move to in the front of 5 and then set another 5, and then press the shift key, and input 5, a total three 5, and then press once SET, displaying SN, and then press up key 3 times, displaying PUH. If you use 5-meter probe, the PUH was change into 500.0, and once you have finished, long press SET for 3 seconds to save it. Method for connecting instrument to sensor: connect 13 to positive pole of the sensor, and connect 7 negative pole of the sensor, and connect instrument 23 and 24 to 220V. V Installation and precaution 5.1 sensor installation 5.1.1 Sensor should be placed where there is no obstacle between emission surfaces and measured liquid, it also should be far way from feeding throats, chart Ⅰ. 5.1.2 Tank shape should be considered. Some type of container will bring second echo, especially conical and spherical tank. A good installation place will solve the problem, chart Ⅱ. 4

5.1.3 Lever meter can be installed by flange or 61 hole, whatever installation way, make sure the sensor bottom through the installation hole or flange 5

5.1.4 If the liquid to be measured has sewage, afloat impurities or fluctuation, use a waveguide and the diameter of the waveguide should over 120mm 5.2 Work mode This instrument has two mode, the difference as following 5.2.1 Measure liquid level B(Installation Height)is the distance from bottom of container to sensor surface,a is the distance between sensor surface and liquid surface, D is the height of liquid,d= B(Installation Height)-A,display value is bottom of container to liquid surface(d). 5.2.2 Measure air distance Set BD =0,display value is distance from sensor surface to liquid surface(a). 5.3 DC24V power is better. When it s from switch power, the DC negative must contact ground. Refer to the tags attached on the instrument for wiring. In order to keep it working reliable and display precise, please electrify >15 minutes before work. When operated outdoors, it should be placed under a sun screen to avoid direct under sunshine and rain. Lightning proof measures should also be taken outdoor. 6

Ⅵ Wiring diagrams 6.1 Definition of lead Definition of lead pin/color applied Supply + 2/red Yes/ No Supply - 1/black Yes/ No Current output yellow Yes/ No Voltage output Yes/ No Serial output Yes/ No Output controlⅠ (NPN) Output control Ⅱ (NPN) Green Blue Yes/ No Yes/ No 6.2 Wiring diagram of current (voltage) output connecting with secondary instrument Level meter Secondary instrument Supply + Output + Output Supply DC24V + Input +(3 wire for power +) Input GND 7

6.3 serial output connecting with PC Power Level meter RS-485 PC D C Supply + Output A Output B Supply A B Serial port 6.4 NPN output wiring diagram Conventional relay TTL output 8

VII. Trouble shooting 1 Not working,no display, no sound Probable reason: 1 Power is not connected or + - polarities are connected reversely 2 Too low voltage resulting no working or too high resulting damage Remedy: 1 Check to ensure correct wiring as instructed. 2 Use 12-24V DC supply, or contact with distributor 2 No display, sensor has sound Probable reason: 1 Turning off 2 Connected to high voltage, damaging display chip Remedy: 1 Press B to turn on display; 2contact with distributor. 3 With sound and display, but the values not change with distance 1 Too low input voltage 2 Sensor or power driver damaged Remedy 112-24V DC supply 2Contact with distributor 4 With display,but value is irregular fluctuation Probable reason 1 Deflective installation 2 improper setting of pulse intensity, leading to great residual vibration or diffraction 3 more than 2 instruments work together, interfering each other 4 too much electromagnetic disturbance in working area

5 There are bubbles or debris on liquid Remedy 1 Adjust the axis of sensor vertical to surface to be measured 2 in general, range of 1-3m, transmit intensity is 2-5 3 try to eliminate interference 4 find out disturbance source and shield 5 eliminate bubbles or debris 5 Big error Probable reason 1Non vertical installation, leading to multiple reflection 2installed too close to wall, sonic wave reflected midway3 check BD 4 check temperature display Remedy 1Adjust installation positions several times.2 correctly set BD 3adjust temperature ( TE ) to proper value. 6 Abnormal current output Probable reason 1Too large load resistance 2FS, AL or AH changed. 3 undesired supply rectification and filtering 4 electrify time is not enough Remedy 1Lower load resistance 2readjust parameter3 replace with DC regulated supply with larger capacity 4electrify >15 minutes before work 7 Abnormal RS485 output Probable reason 1Reverse connecting of A and B 2incorrect parameter of serial ports, its not match with main unit Remedy 1 Change wiring, 2reset parameter, same with main unit

8 Abnormal control output Probable reason 1Wrong parameter. Setting 2external current-limiting resistor too large 3external current-limiting resistor too small, damaging the level meter Remedy 1 Reset parameter 2decrease current-limiting resistor 3 contact with distributor Manufacturer Certificate Product :Ultrasonic level meter Mode :MH-A Main specification Sense range:fs= m Unusable area: 300mm 400mm; 500mm; other Accuracy: ±0.3% max range; ±2mm; other Display resolution:1mm Output: 0-20mA; 4-20mA; 0-5V; 1-5V; 0-10V; 1-10V; RS485; other upper and lower limit switch ; Working temperature: normal; -10-60 ; other Working pressure: normal; other Working humidity: 80%RH Storage temperature:-40 85 Storage humidity: 70%RH Working voltage:12-24v DC 11

Normal power consumption:<1.5w Inspected by: Delivery date: 09. 16 th, 15 Guarantee log Purchaser Address Product Item No. Repair record Telephone Post code Type Delivery date Notes 1. According to THREE GUARANTEES, When there are problems with the product under correct operation, it can be refunded, changed and repaired free of charge within one week, three months and one year respectively from the day it was bought. 2. For the problems caused by improper use, only the cost of material will be charged. 3. The product can not be dismantled or unsealed without manufacturer s agreement; otherwise the repair service is not available. 4. The freight out and home in relation to repair will be paid by customer. 12