Operating instructions Programming and display unit PP / / 2010

Similar documents
Operating instructions Pressure sensor. PN50xx / / 2010

Operating instructions Pressure sensor. PN78xx / / 2010

Operating instructions Pressure sensor. PE30xx / / 2010

Operating instructions Electronic temperature sensor TN /00 04/2011

Operating instructions Control monitor for temperature sensors TR /00 04/2011

Operating instructions Pressure sensor. PN70xx / / 2010

Operating instructions Pressure sensor. PN70xx / / 2012

Operating instructions Electronic pressure sensor. PM205x /01 09/2011

Operating instructions Memory plug E /02 11/2011

Pressure switch RE B/ Type HEDE10.../1/ Operating instructions

Operating instructions Combined pressure sensor. PN22xx / / 2010

Installation Instructions Temperature transmitter TAA /00 06/2011

Operating instructions Electronic pressure sensor. PI109x / / 2010

Operating instructions Electronic digital pressure sensor EPS25-XXXX-1001

Operating instructions Electronic pressure sensor. PN2xxx / / 2015

Operating instructions Electronic pressure sensor. PN22xx PN26xx / / 2015

Operating instructions Electronic pressure sensor PN7xxx

Operating instructions Electronic pressure sensor. PN72xx PN73xx PN76xx / / 2016

Operating instructions Optical distance sensor O1D / / 2008

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GI712S

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

Operating instructions Optical distance sensor O1D / / 2012

Operating instructions. ProcessLine analogue module AC / / 2012

Operating instructions Electronic pressure sensor. PF295x /00 07/2016

Operating instructions. Speed monitor D / / 2014

Operating instructions Mechatronic flow sensor SBY2xx SBG2xx SBN2xx SB0524

SM9000. Made in Germany

Operating instructions Electronic temperature sensor TN7511

Operating instructions. Switching amplifier DN0210 DN / / 2015

NOVOTURN Multiturn Sensor non-contacting Series RSM2800 analog

Operating instructions Flow sensors SAxx04 SAxx14

Operating instructions. Standstill monitor A / / 2011

Operating instructions Encoder PerformanceLine. RxP5xx /00 04/2018

NI REM Remote I/O Overview DATASHEET. Digital Output Module for Remote I/O

AI561 Analog Input Module

AO561 Analog Output Module

Operating instructions Control monitor for temperature sensors TR7439

Instruction manual. Electronic pressure gauge (EPG) IM-TE91K033-EN5. Original manual

DC561, digital input/output module,

MINI MCR-SL-UI-REL(-SP)

NOVOHALL Rotary Sensor touchless transmissiv. Series RFC4800 SSI, SPI, Incremental

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Multifunctional time delay relay MFT U31S, MFT U41SE

TF501, TF521 Terminal Bases

Pressure switch type DG 51 E

DC562, digital input/output module,

DI572 Digital Input Module

NOVOHALL Rotary Sensor non-contacting. Series RSX-7900

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

DI561 Digital Input Module

Fork light barriers SOOF

RMCN22BD Analog Converter ma - for Zelio Analog

NOVOTURN Multiturn-Sensor non-contacting. Series RSM2800 digital SSI, SPI

DX561 Digital Input/Output Module

Thread length (overall length) material

Electronic timer CT-AHD.22

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

MINI MCR-SL-UI-2I(-SP)(-NC)

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

SM9000. Magnetic-inductive flow meter. Made in Germany

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

NI REM Remote I/O Overview DATASHEET. Analog Output Module for Remote I/O

TU531, TU532 Terminal Unit

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

NI REM Remote I/O Overview DATASHEET. Digital Input Module for Remote I/O

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Operating instructions Optical distance sensor. O5D15x / / 2014

Zelio Control-modular measurement and control relays 1

MINI MCR-SL-PT100-UI(-SP)(-NC)

Operating instructions Electronic pressure sensor PI28xx

Communications & Networking

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Power Supply HARTING pcon

DC541 Digital Input/Output Module

Fork light barriers SOOF

Manual pressure sensors DW35311x DW36311x

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Contact protection relay

AO523 Analog Input Module

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Redundancy unit CP-A RU

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Operating instructions Monitor FD-2 DR2005 DR / / 2007

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

Installation instructions Ethernet switch EC / / 2011

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Power Supply HARTING pcon

Products no longer available

Original operating instructions Safety relay with relay outputs G1501S / / 2016

AI531 Analog Input Module

Product Information ECN 1324S EQN 1336S. Absolute Rotary Encoders with DRIVE-CLiQ Interface for Safety-Related Applications

Electronic timer CT-ERD.12

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Transcription:

Operating instructions Programming and display unit PP2001 704795 / 00 05 / 2010

Contents 1 Preliminary note3 1.1 Explanation of symbols 3 2 Safety instructions 3 3 Items supplied 4 4 Functions and features 4 5 Function 4 6 Installation 5 7 Electrical connection5 7.1 Offline operation 5 7.1 Online operation 6 8 Operating and display elements 7 9 Menu8 9.1 Menu structure 8 10 Operation 9 10.1 Connection of a sensor / initialisation 9 10.2 Setting the sensor parameters 10 10.3 Copying the parameter set of a sensor 12 10.4 Changing a stored parameter set 13 10.5 Transferring a parameter set to other sensors 14 10.6 Remote display / remote evaluation 15 11 Scale drawing 16 12 Technical data 17 2

1 Preliminary note 1.1 Explanation of symbols Instruction > Reaction, result [ ] Designation of pushbuttons, buttons or indications Cross-reference Important note: Non-compliance can result in malfunctions or interference. 2 Safety instructions Please read the product description prior to set-up of the unit. Ensure that the product is suitable for your application without any restrictions. If the operating instructions or the technical data are not adhered to, personal injury and/or damage to property can occur. Check the compatibility of the product materials ( Technical data) with the media to be measured in all applications. For the scope of validity culus: The device shall be supplied from an isolating transformer having a secondary Listed fuse rated as noted in the following table. Overcurrent protection Control-circuit wire size Maximum protective device rating AWG (mm 2 ) Ampere 26 (0.13) 1 24 (0.20) 2 22 (0.32) 3 20 (0.52) 5 18 (0.82) 7 16 (1.3) 10 3

3 Items supplied 1: PP2001 2: cable for connection of a sensor to PP2001 The following components are available as accessories (to be ordered separately): Connection cable with M12 connector for voltage supply and output signals of the sensor ( catalogue or www.ifm.com). 24 V power supply (order no. E30080). 4 Functions and features The unit can be used for diagnosis and parameter setting of pressure sensors. The sensor must be suitable for communication with PP2001 or PP2000. Check the indications in the operation instructions of the sensor. PP2001 is suitable for mobile use as well as for permanent installation ( 6 Installation). Sensors can be read and parameterised before installation and set-up or during operation. If you change parameters during operation, the operating principle of the production plant will be influenced. Ensure that there will be no malfunctions in your plant. 5 Function The unit fulfils the following functions: It supplies the sensor with operating voltage. It detects type, measuring range and the current parameter set of the sensor. It reads and displays the current measured value of the sensor. It transmits the evaluation signals of the sensor. 4

It permits modification of the current parameters of the sensor. The unit has a rewriteable read-only memory. It can store the parameter set of a sensor and transmit it to other sensors of the same type by means of simple actions (COPY and SEND). A stored parameter set can be changed and stored again as desired. They provide the unit with the following operating options : Remote parameter setting of sensors ( 10.2). Fast programming / series programming ( 10.3 / 10.5). Changing a stored parameter set ( 10.4). Remote display / remote evaluation ( 10.6). 6 Installation For stationary operation two types of installation are possible: Fixing with mounting clamp Fixing with mounting bracket A: mounting clamp (to be ordered separately as accessories; order no. E10077). A: mounting bracket Diameter of the bore hole: 18.5...20 mm. Loosen the threaded sleeve (B). Insert the unit in the bore hole. Screw the sleeve and tighten firmly. 7 Electrical connection 7.1 Offline operation Operation outside the production plant Connect 24 V power supply to PP2001 (plug A). Connect the sensor to PP2001 (socket B) via the supplied connection cable. 5

7.1 Online operation Operation with installed sensor during operation of the production plant Disconnect power. Disconnect the connector from the sensor and screw it to PP2001 (plug A). Connect the sensor to PP2001 (socket B) via the supplied connection cable. Switch on the supply voltage. 6 If you change parameters during operation, the operating principle of the production plant will be influenced. Ensure that there will be no malfunctions in your plant.

8 Operating and display elements 1 to 8: indicator LEDs - LED 2: green = indication of the system pressure in mbar. - LED 2 + LED 1: green = indication of the system pressure in mws. - LED 3: green = indication of the system pressure in bar. - LED 3 + LED 1: green = indication of the system pressure in mmws. - LED 4: green = indication of the system pressure in kpa. - LED 4 + LED 1: green = indication of the system pressure in inh2o. - LED 5: green = indication of the system pressure in MPa. - LED 5 + LED 1: green = indication of the system pressure in mmhg. - LED 6: green = indication of the pressure system in PSI. - LED 6 + LED 1: green = indication of the pressure system in inhg. - LED 7: yellow = output 2 is switched. - LED 8: yellow = output 1 is switched. 9: Alphanumeric display, 4 digits - System pressure is displayed. - Parameters, parameter values and action points are displayed. 10: Set button - Setting of the parameter values (continuously by keeping the button pressed; incrementally by pressing once). - Triggering a COPY or SEND action. 11: Mode/Enter button - Selection of the parameters and acknowledgement of the parameter values. 7

9 Menu 9.1 Menu structure 1: sensor-specific parameters (depending on the connected sensor) 2: action points of the PP2001 8

10 Operation 10.1 Connection of a sensor / initialisation 1 Connect the sensor to PP2001. Apply operating voltage. >> Initial display is shown. 2 >> The current measured value is displayed. PP2001 and sensor are operational. Sensor type (running display) Notes: If only [COPY] and [SEND] are active in the operating mode, the connected sensor does not support the parameter setting and editing functions. Only the evaluating function (Transmission of the output signals, 10.6) and the copy functions ( 10.3 and 10.5) are supported. If the sensor is disconnected, a running display indicates the type of the stored data set. Then [EDIT] is displayed. If another sensor is connected, the initialisation (step 1) starts again. Error messages [E.COM] [E.INI] Input output error: communication error / data transfer disturbed. Communication error or data error; initialisation / support of the sensor not possible. 9

10.2 Setting the sensor parameters During parameter setting the unit remains in the operating mode. It continues its monitoring function with the existing parameters until the parameter setting has been completed. The following steps must be taken for each parameter setting: 1 Connect the sensor to PP2001. >> The unit passes the initialisation phase and then displays the current measured value. 2 Selection of the parameter Press [Mode/Enter] until the requested parameter is displayed. 10 3 Setting of the parameter value Press [Set] and keep it pressed. >> Current setting value of the param- eter flashes for 5 s. >> After 5 s: setting value is changed: incrementally by pressing the button once or continuously by keeping the button pressed. Numerical values are incremented continuously. For reducing the value: let the display move to the maximum setting value. Then the cycle starts again at the minimum setting value. 4 Acknowledgement of the parameter value Press [Mode/Enter] briefly. >> [SEND] is briefly displayed, then the parameter designation. >> The new setting value is stored in the sensor and now effective. Setting of other parameters: Start again with step 1. Finishing the parameter setting: Press [Mode/Enter] several times until the current measured value is displayed or wait for 15 s. The unit returns to the operating mode if no button is pressed for 15 s after acknowledgement of the new parameter value. Finishing the parameter setting and storing the changed parameter set in PP2001: Carry out the [COPY] action ( 10.3)

With this parameter setting only the parameter set of the sensor is changed. The parameter set stored in PP2001 remains unchanged. Do not activate the action point [SEND]. This would cause the parameter set stored in PP2001 to be transferred to the sensor. If [SLoc] is displayed when attempting a modification of a parameter value, the sensor is locked via FDT software. This locking can only be removed via FDT software. Change from menu level 1 to menu level 2: Press [Mode/Enter] until [EF] is displayed. Press [Set] briefly. >> The first parameter of the sub-menu is displayed (here: [HI]). Locking / unlocking The sensor can be locked electronically to prevent unintentional settings. Make sure that the unit is in the normal operating mode. Press [Mode/Enter] + [Set] for 10 s. >> [Loc] is displayed. During operation: > [Loc] is briefly displayed if you try to change parameter values. For unlocking: Press [Mode/Enter] + [Set] for 10 s. > > [uloc] is displayed. On delivery: unlocked. Timeout: If no button is pressed for 15 s during parameter setting, the unit returns to the operating mode with unchanged values. 11

10.3 Copying the parameter set of a sensor 1 Connect the sensor to PP2001. >> The unit passes the initialisation phase ( 10.1) and then displays the current measured value. 2 Press [Mode/Enter] until [COPY] is displayed. 3 Press [Set] and keep it pressed. >> [WAIT] flashes. Release [SET]. >> [DONE] is briefly displayed. The copying process is finished and the parameter set of the sensor is stored in PP2001. 4 Press [Mode/Enter] briefly. >> The unit goes into the operation mode (the sensor type and then the current measured value are displayed). Error messages when carrying out the COPY action: [E.COM] Input output error: communication error / data transfer disturbed. [E.INI] Communication error or data error; initialisation / support of the sensor not possible. [E.SEN] Sensor type error: the sensor type is not supported. [E.STO] Error when storing the data set (e.g. B: data set too large). The error message is displayed for 5 s. Then the menu [COPY] is again active. In case of communication via IO-Link with a low baud rate the operation can take one minute or more. 12

10.4 Changing a stored parameter set 1 Apply operating voltage. >> Initial display is shown. 2 As soon as the running display appears: press [Mode/Enter] briefly. > [EDIT] is displayed. > Sensor type (running display) 3 Press [Set] for 5 s. >> The first menu item is displayed (here [SP1]). 4 >> Carry out the parameter setting ( 10.2). This operation can only be carried out if no sensor is connected. If for the data set stored in PP2001 only the copy functions are supported, the editing function is not active. After step 2 ([Mode/Enter] pressed briefly), [TYPE] and the sensor type are displayed (running display). Timeout: If no button is pressed for 15 s, the unit returns to step 2. A parameter change which has not been acknowledged is not adopted. 13

10.5 Transferring a parameter set to other sensors 1 Press [Mode/Enter] until [SEND] is displayed. 2 Press [Set] and keep it pressed. >> [WAIT] flashes. Release [SET]. >> [DONE] is briefly displayed, then again [SEND]. The copying process is finished and the parameter set of PP2001 is stored in the sensor. Transferring a parameter set to other sensors Remove the sensor from the connection cable. >> [- - - -] is displayed until a new sensor is connected. Connect the new sensor. >> [READ] is briefly displayed, then [SEND]. Carry out step 2. The processes can be carried out as often as desired. Finishing the copying process: Press [Mode/Enter] when [SEND] is displayed. >> The unit goes into the operation mode (the sensor type and then the current measured value are displayed). In case of communication via IO-Link with a low baud rate the operation can take one minute or more. Error messages when carrying out the SEND action: [E.COM] Input output error: communication error / data transfer disturbed. [E.INI] Communication error or data error; initialisation / support of the sensor not possible. [E.SEN] Sensor type error: the parameter set does not correspond to the type / measuring range of the sensor. [E.DAT] Data error: at least one parameter of the internal data set is not within the valid range of the connected sensor. The error message is displayed for 5 s. Then the menu [COPY] is again active. 14

10.6 Remote display / remote evaluation After connection of a sensor and initialisation ( 10.1) the current measured value is diplayed. The output signals of the sensor are transmitted and provided at the output of the PP2001. Reading of the set parameters Press [Mode/Enter] briefly: the parameters are displayed one after the other. Press [Set] briefly: the corresponding parameter value is displayed for about 15 s. After another 15 s the unit returns to the Run mode. Error messages [SC1] [SC2] [SC] Short circuit in OUT1 of PP2001.* Short circuit in OUT2 of the connected sensor (signalled via the communication interface to PP2001).* Short circuit in both outputs.* *The output concerned is switched off as long as the short circuit exists. These messages are displayed even if the display is switched off. 15

11 Scale drawing Dimensions in mm 1: 4-digit alphanumeric display 2: LEDs (display unit / switching status) 3: programming button 4: connection for voltage supply and output signals 5: connection for sensor 6: nut 16

12 Technical data Operating voltage [V]... 18... 32 DC Current rating [ma]...250 Short-circuit protection (pulsed); protected against reverse polarity and overload Voltage drop [V]...< 2 Current consumption [ma]...< 40 Power-on delay time [s]...1.5...10 *) Response time for transferring the sensor output signal [ms]...ou1 < 50 / OU2 = 0 Measurement / display cycle time [ms]...200 Housing materials...stainless steel 316L / 1.4404; PC Copolymer; PBT (Pocan); FPM (Viton) Protection... IP 67 Protection class...iii Insulation resistance [MΩ]]...> 100 (500 V DC) Shock resistance [g]... DIN IEC 68-2-27: 50 g (11 ms) Vibration resistance [g]... DIN IEC 68-2-6: 20 g (10...2000 Hz) Operating temperature [ C]... -25... 80 Storage temperature [ C]... -40... 100 EMC EN 61000-4-2 ESD:... 4 kv contact discharge / 8 kv air discharge EN 61000-4-3 HF radiated:... 10 V/m EN 61000-4-4 Burst:... 2 kv EN 61000-4-6 HF conducted:... 10 V *) depending on the connected sensor More information at www.ifm.com 17