Surge Protective Devices. STV25K Series. Instruction Manual

Similar documents
Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual

400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual

300 Series 330/320 Surge Protective Device Installation, Operation and Maintenance Manual

Surge Protective Devices. Installation & Operation Manual. NEMA 12 (Steel) NEMA 1 (Non-Metallic) Model 350

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

Form C contact for remote monitoring UL 1449, UL 1283, cul recognized component, CE 5 Year Limited Warranty

Eaton s SPD Series for integration into electrical distribution equipment

Specifications, Installation, and Operating Instructions

BSPD Surge Protective Devices

DeltaV Bulk Power Supplies

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B

R-LB R-LX Series Installation, Operation & Maintenance Manual

DeltaV Bulk Power Supplies

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Surge Protection Devices (SPD)

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Instruction Manual IM E Table of Contents

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

File E Project 08NK October 2, 2009 REPORT SURGE PROTECTIVE DEVICES (VZCA) GE Zenith Controls Bonham, TX

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

Surge Protection Devices Ex9UE2

File E Project 08NK November 24,2009 REPORT TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7)

Gas Discharge Tube. Indicator Light(2) UL Parallel 1600 V N N / PU-20KS10KTTN. UL Series 1600 V N N 15 A PU-20KD10KTTN

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

File E Project 05NK Issued: Revised: REPORT CLASSIFIED FOR USE WITH SPECIFIED EQUIPMENT (XUPD)

Innovative Technology line filters and surge protectors

GE TR7000 Series Wall Mounted Surge Protective Device (SPD)

FP-PS-4. Features. Installation

THE SURGE PROTECTION SOLUTION

Grid to Chip Surge Protection Product Catalog

Installation and Operation Manual

LPI SST Surge Filters

ABL8REM24050 regulated SMPS - 1 or 2-phase V AC - 24 V - 5 A

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

TDX Series. Transient Discriminating TM TVSS

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

MultiVOIP SIP Gateways

PHOENIX CONTACT Features

ETD-BL-1T-OFF-CC- 10S

Internal Modular SPDs

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Redundancy unit CP-A RU

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Technical Data Sheet Medium Current Power Surge Filters

S66 Series Electronic Fan Speed Control

User Manual - Canada. TPS3 03 DC For DC Photovoltaic Applications. Surge Protective Device

Solar Combiner Enclosure

Isobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

US Catalog March Surge protective devices (SPDs) UL range

Liebert Maintenance Bypass Cabinet

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

SP SP-T-9

Liebert MicroPOD 230V

List of contents. 7-2 CE (ENC EN55022) declaration of conformity CE (LVD EN60950) declaration of conformity. 15 發行章

ABL8BBU24400 battery control module V DC - 24 V - 40 A - for regulated SMPS

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

PRO-1250D CT MID DIN rail three phase four wire energy meter.

SECTION SURGE PROTECTIVE DEVICES

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

Westell. Breaker Panel Technical Practice NPDRP1114

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Breaker Panel Technical Practice NPDRP1114

MINI-PS AC/10-15DC/8

2U Congestion Alert Rack Insert for UK

CPS block & CPS nano UL rd Ed. Surge protective devices (SPD)

SLATE. Digital I/O Module INSTALLATION INSTRUCTIONS R8001D4001

I-Line SPDs Square D TM Internally Mounted Surge Protective Devices

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

FLEX Ex Spring Clamp Terminal Base

NEMA 1 / IP40 metal housing. Compact design

Liebert LM Series Surge Protective Device Continuous Protection For Your Business. Surge Protection For Business-Critical Continuity

EATON Transformer Module

SER-4485-SI-M USER S MANUAL

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

ABL8REM24030 regulated SMPS - 1 or 2-phase V AC - 24 V - 3 A

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Digital ac/dc (24V) Input Module

Thank you for selecting UTC RETAIL s innovative Model 1170 Point of Sale solution!

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Premium Online Series

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

for the SPV Installation and Operation Manual Instruction Manual IM E Contents

ABL1REM24025 regulated SMPS - single phase V input - 24 V output - 60 W

Always "On" UPS Systems Inc. USER MANUAL

ABL8WPS24400 regulated SMPS - 3-phase V - 24 V - 40 A

LPI SG + SST Spark Gap Surge Filter

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

Transcription:

Surge Protective Devices STV25K Series Instruction Manual

Contents 1.0 Installation & Operation... 4 1.1 Environment... 4 1.2 Mechanical Dimensions... 4 1.3 DIN Rail Mounting... 5 1.4 Supplemental Enclosures... 5 1.5 Maximum Current Capability... 5 1.6 Recommended Fuse... 5 1.7 Nominal Voltage... 5 1.8 Summary Alarm Contacts... 6 1.9 Conductor Size... 6 1.10 Grounding... 6 1.11 Voltage Protection Ratings... 6 1.12 Wiring Connections... 6 1.13 Applying Power... 6 Table 1: Voltage Ratings & Power Source Configurations... 7 2.0 Specifications... 8 Table 2: Technical Specifications... 8 3.0 Registration & Warranty... 9 3.1 Product Registration... 9 3.2 Warranty Information... 9 While every precaution has been taken to ensure accuracy and completeness in this manual, EGS Electrical Group, LLC. assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. The SolaHD and Emerson logos are registered in the U.S. Patent and Trademark Office. All other product or service names are the property of their registered owners. 2011 EGS Electrical Group, LLC. All rights reserved. Specifications are subject to change without notice.

1.0 Installation & Operation The SolaHD STV25K Series Surge Protective Device is a high-quality transient diversion system designed to protect sensitive equipment from damaging transient voltage surges resulting from load switching, lightning strikes, and other sources. The installer should perform the following steps to ensure a quality installation. Please read all instructions before starting the installation of this product. These instructions do not replace national or local electrical codes. Check applicable codes to ensure compliance.! DANGER! Only qualified personnel should install or service this system. Electrical safety precautions must be followed when installing or servicing this equipment. To prevent risk of electrical shock, turn off and lock out all power sources to the unit before making electrical connections or servicing. 1.1 Environment The unit is designed for indoor operation in an ambient temperature range of -40 C to +60 C (-40 F to +140 F), with a relative humidity of 0% to 95% noncondensing. Do not install in areas with excessive dust, corrosive vapors, flammable materials, or explosive atmospheres. 1.2 Mechanical Dimensions STV25K Series Instruction Manual 4

1.3 DIN Rail Mounting 1. Tilt unit as illustrated. 2. Put unit onto the DIN rail. 3. Push unit downward until it stops. 4. Push at the lower front edge to lock. 5. Gently shake the unit to ensure that it is secure. NOTE: Press the button located at the top (rear) of the enclosure to unlock and remove from the DIN rail. 1.4 Supplemental Enclosures The STV25K must be installed inside an enclosure and located to prevent accidental contact with terminals during maintenance and service. 1.5 Maximum Current Capability The total current draw in which the STV25K may continuously handle is 20 A. NOTE: Overloading the unit can cause permanently damage. 1.6 Recommended Fuse Bussman type SC-25 Class G, rated 250 V ac minimum; 25 A maximum or equivalent. 1.7 Nominal Voltage The maximum continuous operating voltage (MCOV) for model STV 25K-10S is 150 V ac; 275 V ac for model STV 25K-24S. NOTE: Failure to use the unit at its rated voltage can permanently damage the unit or provide inadequate surge protection. STV25K Series Instruction Manual 5

1.8 Summary Alarm Contacts Summary alarm Form C (1 N.O. and 1 N.C.) relay contacts rated 125 V ac, 5 A maximum are provided for remote indication of protection status. Connections can be made to these terminals using #18 AWG conductors. 1.9 Conductor Size The conductor size to the input and output of the STV25K ranges from #14 AWG to #10 AWG. 1.10 Grounding Input and output ground terminals must be connected for proper operation. This grounding is not only required for safety, but also for equipment performance. Incorrect grounding can reduce or impede the operation of the unit. 1.11 Voltage Protection Ratings (VPRs) To maintain the voltage protection ratings marked on these products, as obtained by Underwriters Laboratories, Inc. in accordance with ANSI/UL 1449, 3 rd edition, the Standard for Safety, Surge Protective Devices (SPDs), #12 AWG wire must be utilized to connect the STV25K to your protected load. Connections made with conductors other that #12 AWG may result in different VPRs. 1.12 Wiring Connections Before making connections to the unit, verify that the unit model number and nameplate voltage rating are appropriate for connection to the intended power source. See Table 1 for voltage rating applications with typical power source configurations. 1.13 Applying Power Apply power to the unit and ensure status indications are normal. Under normal conditions, the green LED is illuminated. If the green LED is not illuminated, check all connections and ensure reliable and proper voltages are supplied to the unit. For further assistance, please contact SolaHD Technical Support at (800) 377-4384 or (847) 268-6651 or by e-mail at solahd.technicalservices@emerson.com. STV25K Series Instruction Manual 6

Table 1: Voltage Ratings & Power Source Configurations Model: STV25K-10S Nominal Voltage (50/60 Hz): 120 V ac System Configuration: Single-phase, 2W + G Source Configuration: Model: STV25K-24S Nominal Voltage (50/60 Hz): 240 V ac System Configuration: Single-phase, 2W + G Source Configuration: STV25K Series Instruction Manual 7

2.0 Specifications Table 2: Technical Specifications Parameters STV25K-10S Model STV25K-24S Nominal Input Voltage 120 V ac 240 V ac System Configuration Single-phase, 2W + G Single-phase, 2W + G Maximum Continuous Operating Voltage (MCOV) Operating Frequency Range Input Current Rating Short Circuit Current Rating (SCCR) Surge Current Rating Nominal Discharge Current (I N ) 150 V ac 275 V ac 47 63 Hz 20 A 5 kaic when protected by a listed Class G fuse rated at 25 A, 480 V ac minimum 25 ka per phase Response Time <0.5 ns Modes of Protection All Modes: L N, L L, L G, N G EMI/RFI Noise Rejection Normal mode: 50 db minimum Common mode: 40 db minimum Operating Temperature -40 C to +60 C (-40 F to +140 F) Operating Humidity 0 to 95% non-condensing Dimensions, D x W x H 4.35 in. x 2.56 in. x 4.84 in. (110.5 mm x 65.0 mm x 122.9 mm) Net Weight 3.0 lb. (1.36 kg) Enclosure Metal, IP20 Mounting Type DIN rail mounting NOTE: Optional chassis mounting bracket is available, P/N SDN-PMBRK2 Connections Screw terminals, #12 AWG Status Indication Green LED, Form C relay contacts Safety Approvals UL 1449 3 rd edition Warranty 10 year limited warranty UL 1449 3 rd Edition Type 4 Voltage Protection Ratings (VPRs) Line to Neutral 500 V N/A Line to Line N/A 900 V Line to Ground 500 V 900 V Neutral to Ground 500 V N/A 3 ka STV25K Series Instruction Manual 8

3.0 Registration & Warranty 3.1 Product Registration To register your product for updates and information on service and support, visit our Web site at: http://www.solahd.com/support/registration.htm. 3.2 Warranty Information Please see the Terms & Conditions of Sale. STV25K Series Instruction Manual 9

NOTES

www.solahd.com (800) 377-4384 (847) 268-6651 solahd.technicalservices@emerson.com P/N: 82166 Rev 1 May 2011