COLLABORATE TO WIN. 03/31/2017 Digital Substation Turning IEC61850 features into benefits. Peter Rietmann, Program Manager Digital Substation NA

Similar documents
Applications and Industry Activities

Digital Substation, bridging the gap between analogue and digital technologies.

POWER GRIDS. We are bridging the gap. Enabling Digital Substations.

Overview and Application

ABB Automation & Power World: April 18-21, 2011 IEC connectivity, networking and state-of-the-art Relion protection/control technologies

Entergy Development and Deployment of IEC Protection and Control Including Process Bus

ABB Group April 19, 2011 Slide 1

A Current Based, Communication Assisted High Speed Protection System to Limit Arc Energy. Patrick Robinson Altelec Engineering

Digital Substation Unrestricted Siemens AG 2017 siemens.com/digital-substation

Upgrading From a Successful Emergency Control System to a Complete WAMPAC System for Georgian State Energy System

What s New in IEC 61850? Status and Advantages

IEEE 1588v2 Time Synchronization in Energy Automation Applications Case Studies from China

/ Charlie Hsu, Sales, PSAC, Power System Division, TWABB, June.2013 IEC The Approach and the Standard. ABB Group July 1, 2013 Slide 1

I E C E N G I N E E R I N G P R O C E S S I N O F F S H O R E W I N D F A R M S

Impact of IEC Edition 2 on Functional Testing of Protection Systems. Dr. Alexander Apostolov March 2018 San Francisco, CA

Lecture 5 Substation Automation Systems. Course map

FITNESS GB s Pilot Multi-Vendor Digital Substation - Architecture and Design Philosophy

IEC in Digital Substation and Cyber security

Ethernet Network Redundancy in SCADA and real-time Automation Platforms.

Designing a new IEC substation architecture

Deploying Digital Substations: Experience with a Digital Substation Pilot in North America. Harsh Vardhan, R Ramlachan GE Grid Solutions, USA

Trends in Station Bus and Process Bus Communications Via the Several IEC Protocols. Schweitzer Engineering Laboratories, Inc.

Benefits, offering and references

Performance considerations in digital substations

Digital Substation Overview of Technology, Industry

Digital substations. Introduction, benefits, offerings

Peter Overgaauw Pascal Stijns 27 Oct 2016 EXPERION PKS CONTROLS ELECTRICAL SYSTEMS TOO!

WHY GO DIGITAL? Evolving from Conventional to Intelligent Digital Substations. GE Grid Solutions. White Paper by: imagination at work

Electrical Integration with Smart Communication

Jehanpour Ranjkesh, Integrator Partner Seminar 2012 Station level product news Automation Controller COM600

Relion 630 series. Load-shedding controller PML630 High performing load-shedding solution for industrial and utility power networks

SCADA Training - T&D Automation

Peter Kreutzer, PSSAM/Automation Power World 2011 New Delhi, Secure and reliable Redundant communication network and cyber security

Process Bus overcoming the complexity of process bus adoption to drive down design, implementation and operation costs

Protection and Control REX640 Product Presentation

REALISATION OF AN INTELLIGENT AND CONTINUOUS PROCESS CONNECTION IN SUBSTATIONS

Hugo E. Meier, Heidelberg, Germany, June 2014 Integrator Partner Seminar2014 Substation automation trends

Lecture #7 Substation Automation with IEC 61850

////// SUBSTATIONS. Control command and local Scada

Migration Paths for IEC Substation Communication Networks Towards Superb Redundancy Based on Hybrid PRP and HSR Topologies

Reviewing Smart Grid Standards for Protection, Control, and Monitoring Applications

JULIO OLIVEIRA, ABB POWER GRIDS GRID AUTOMATION, DECEMBER 01 ST ABB Ability - Digital Substations. FISE 7a Edición

How smart can the grid really be?

SPECIAL REPORT FOR STUDY COMMITTEE B5 (Protection and Automation)

Products for digital substations SIPROTEC 6MU805. Merging Unit for conventional instrument transformer. Integrated PRP, HSR. siemens.

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations

SIPROTEC 7SC805. Merging Unit for conventional instrument transformer. Products for digital substations.

Mission Possible Easy Upgradable and Cost-Efficient Distribution Substation

Substation Automation Products. Line differential protection RED670 Relion 670 series

IEC meets Industrial IT

IEC OBJECT MODELS OF MULTIFUNCTIONAL PROTECTION RELAYS

SIPROTEC 5 Protection, automation, and monitoring

Christian Pinzon, ABB Power Grids The power of one solution for distributed busbar protection What s new in Relion REB500 version 8?

DS Agile C264. Grid Solutions. Dual-bay Modular Substation Controller. Multi-function Controller. Automation and Control. Advanced Communication

Non-conventional instrument transformers Advanced GIS substations with IEC LE process bus

Lecture 6 Substation Automation Systems

PROOF OF CONCEPT FOR MODEL-BASED TESTING OF IEC SMART GRID USING TTCN-3 & UML

ISIO 200. Binary Input/Output (I/O) terminal with IEC interface

Substations go fully digital but stay compatible

FEEDBACK ON INSTALLED EXPERIENCE WITH FULLY-DIGITAL SUBSTATIONS

Providers of a Comprehensive Portfolio of Solutions for Reliable Ethernet and Synchronization in the Energy Market. Industrial

IEC61850 Maintenance approach. 2017, September the 27 th

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

Ahead of the challenge, ahead of the change. Beyond classical substation How seamless communication networks can be used in special applications

Importance of Interoperability in High Speed Seamless Redundancy (HSR) Communication Networks

This webinar brought to you by the Relion product family Advanced protection and control from ABB

This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Synchronous switching of distribution sub networks

A NEW APPROCH FOR TEST IN SUBSTATION WITH ENTIRE APPLICATION OF IEC INCLUDING THE PROCESS BUS

Data Model of the Standard IEC 61850

Power Systems Communications Implementation of IEC61850 in a Substation Environment

ABB Protective Relay School Webinar Series Using IEC61850 for Advanced, Reliable Feeder Automation. Bryan Shannon August 20, 2013

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

Battery Energy Storage System Information Modeling Based on IEC 61850

This webinar brought to you by the Relion product family Advanced protection and control from ABB

BREAKER FAILURE PROTECTION

IEC Test Equipment Requirements

Trends, Lessons and Benchmarks

USE CASE 14 CONTROLLED ISLANDING

Answers for energy. SIPROTEC 5 the new benchmark for protection, automation, and monitoring of transmission grids

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers

Experience with a Digital Substation Pilot in North Ame rica

CASE STUDY. Wind Farm in Mexico Completes First Successful IEC Application With Multivendor Interoperability

Impact of IEC communication protocol on substation automation systems

Power Automation Solutions with the IEC standard

Jim McGhee, Utility Market Manager, RuggedCom Inc.

Application for IEC Parallel Redundant Protocol on a University Campus Micro Grid Power Distribution and Generating System

IDS SAS. Station Automation System for Complex Applications

Utilization of IEC GOOSE messaging in protection applications in distribution network

Smart Distribution Technology

Program. 5 Day IEC Seminar and Training. XXXX Automation & Information Systems XXXX

needs for proper performance

Impact of Measurement and Communication Aspects on Protection of MTDC Grids

SIPROTEC 5 Application Note. Breaker-and-a-half solutions. SIP5-APN-002, Edition 2.

Smart Grid Communications. WFCS 2016 May 3-6, 2016, Aveiro, Portugal

Emerging Technologies and Future Trends in the Automation of Electric Substations

ECE Supervisory Control & Critical Infrastructure Systems IEC Presented by Jake Groat Slides by Rick Liposchak, P.E.

October 05, ECE 421 Session 12. Utility SCADA and Automation. Presented by: Chris Dyer

Substation Configuration Language. Summary August 2006

Transcription:

COLLABORATE TO WIN 03/31/2017 Digital Substation Turning IEC61850 features into benefits Peter Rietmann, Program Manager Digital Substation NA

Increasing Reliability Higher functional integration and process close digitalization SA Distributed solution: SA Central solution: Digital substation solution: GW/ HMI GW/ HMI GW/ HMI GOOSE, MMS 1 2 3 4 5 6 Main1 Main2 Main1 Main2 Process bus GOOSE, SV Switch Gear Switch Gear Digital Switch Gear March 31, 2017 Slide 2

Increasing Reliability Basic network topologies Digital substation solution: GW/ HMI Single network, star or bus Single network, star or bus Easy to configure No network redundancy GOOSE, MMS Main1 Main2 Single network, ring or multiple rings Process bus GOOSE, SV Single network, RSTP Self-healing Complex to configure Reconfiguration delay time in case of network failure Not suitable for process bus Digital Switch Gear March 31, 2017 Slide 3

Increasing Reliability Basic network topologies Digital substation solution: GW/ HMI GOOSE, MMS Link redundancy, PRP Link redundancy, PRP Easy to configure Redundant networks End-to-end redundancy Bumpless no switch over time Suitable for station and process bus High performance, large networks Main1 Process bus Main2 GOOSE, SV Link redundancy, HSR Link redundancy, HSR Easy to configure Bumpless no switch over time Suitable for station and process bus Smaller networks Digital Switch Gear March 31, 2017 Slide 4

Importance Digital Switchgear Trend: Higher integration and more data Fleet Management Data analysis Condition Traditional primary equipment with hardwired interface Transmission: Stand-alone merging units enable digitalization Modular approach to reduce cupper cable process connections Low functionality focus on simplicity Bridging new and old technology e.g. combine NCITs and PT/CTs Distribution: Feeder relays incorporate merging unit function Enable distributed or central functions Digital switchgears Transmission: Primary equipment comes with IEC61850 interface Motor drive for CBs and disconnectors CB monitoring, Transformer monitoring Non conventional instrument transformers Distribution: Feeder relays with merging unit function and NCITs Increased safety and reduced weight March 31, 2017 Slide 5

SP Energy Networks Future Intelligent Transmission NEtwork SubStation Project: SPTEN02 FITNESS Demonstrate a multi-vendor fully interoperable digital substation solution Deploying standardized and fully Integrated substation protection, monitoring and control system based on the IEC61850-9-2 standard. Reduce environmental impact of substations Enhance substation safety Enable increased flexibility and greater controllability in substations Timescale 4 years (Apr 2016 to Mar 2020) The solutions enabled by FITNESS will facilitate reduction in substation costs, improve system access and reduce network constraints feeding through to significant benefits to GB customers March 31, 2017 Reference: https://www.ofgem.gov.uk/sites/default/files/docs/fitness_submission.pdf

SP Energy Networks Future Intelligent Transmission NEtwork SubStation The FITNESS substation design also enables savings in operational practice and procedures. Traditionally, if a protection device fails, the primary plant may operate under depletion i.e. with non-redundant protection for no more than two hours. After two hours, the primary plant must then be taken out of service, resulting in an outage. In conventional practice, to avoid outage, protection device failure requires immediate and urgent response to return the system to normal service. With the FITNESS substation design, hot-standby reserve protection can be used to take over functions of the failed device, thus avoiding the need for resorting to a system depletion or outage. The failed device can be replaced through remote access and configuration change, and does not require a change to wired connections to primary plant, meaning that the primary plant can remain in service throughout. March 31, 2017 Slide 7 Reference: https://www.ofgem.gov.uk/sites/default/files/docs/fitness_submission.pdf

Digital substation Increased system availability through flexibility Approach: Use robust system components, apply redundancy where needed (flexible to application driven performance and availability requirements) Station level Application Redundancy HMI1 HMI2 Available features: End-to-end redundant protection and control systems Seamless communication redundancy with HSR and PRP PRP 1 failed 2 Bay level Application Redundancy Functional redundancy (hot stand-by, hot-hot, substitute, simulate) Process bus HSR Function Substitution MU1 MU2 31 March 2017

Digital substation Increased system availability through flexibility HMI1 HMI2 How to test it before taking into service? PRP Verify communication of substitution IED with MUs 1 failed 2 Verify communication of substitution IED with HMIs Process bus HSR Function Substitution Confirm protection and control functions MU1 MU2 March 31, 2017 Slide 9

Efficient testing without system down time IEC61850 Ed2 Test mode and simulation Testing procedure Protection device receives simulated sampled values from a test device Protection IED will initiate a trip Trip is sent as GOOSE with q.test=true to XCBR XCBR will receive GOOSE but not trip as it is in TEST-BLOCKED mode Output can be verified through OpOk and topok attributes Mod=Test LPHD Pxxx SV (Sim=FALSE) TCTR TVTR Merging Unit Sim=TRUE XCBR Breaker SV (Sim=TRUE) Mod=Test/blocked Test equipment GOOSE (q.test=true) XCBR.Pos.opOk XCBR.Pos.tOpOk March 31, 2017 Slide 10

Operational flexibility and re-configurability Adjusting settings to dynamic load limits Challenge Demonstrate that protection group settings can be selected from wider system observations, thus enabling adaptive protection in case of low carbon generation and fault level changes Automating protection settings choice in response to system observation, e.g. for varying short circuit levels. Replacing nuclear power with wind: Impact on system stability Solution Settings via IEC 61850 for line protection and voltage regulation. This enables IEC 61850 clients to remote parameterize the IEDs in a standardized way. E.g. High-speed distance protection Change zone X&R reaches and load-encroachment blinder area settings remotely Over-current protection: Change current pickup remotely March 31, 2017 Slide 11

Summary - More than 12 years IEC61850 experience demonstrate the maturity of the standard - Initially installations based on station bus, now strong increasing projects with process bus - Increased usage of interoperable IEC61850 features enables utilities to become more flexible and create more reliable solutions - Sum of benefits makes digital substation compliant to IEC 61850 the unmatched solution for substations of the future grid March 31, 2017 Slide 12