ES Energy Saver Product Ranges 90Amp 6000Amp

Similar documents
StacoDVR-5 Digital Voltage Regulator Electromechanical three-phase kVA

ahead of time Voltage Stabilisers

Modular UPS S KVA

UPS Series. features: uninterruptible power supply. what great systems are built on.

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC

PRODUCT PRESENTATION PROTECT C (1-3kVA) SEPTEMBER 2014 BU COMMERCIAL COMPACT-UPS, PM/SR

RT4F-110V/25A RECTIFIER

MAJOR VA Power Inverter

RT4F-48V/50A-WAC RECTIFIER

Postfach 2327, Offenburg * Helmholtzstr. 13, Offenburg. Technical Data. Model protecto ER

TR150 DRIVE STANDARD FEATURES

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

10 kva 3/1 15 kva 3/1 20 kva 3/1 10 kva 3/3 15 kva 3/3 20 kva 3/3 30 kva 3/3 40 kva 3/3 UOUS SERV WARRANTY

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

SACE Emax 2 Specification guide

PCU Supervisory module for the RM 1000 series

Hardwired Uninterruptible Power Supply

RT4F-120V/20A-WAC RECTIFIER

Sentinel Dual High Power

100% electricity. Automatic transfer switch controllers ATL series

ATS Automatic transfer switches Advanced version

RT12-240V/2.4kW Rectifier Specification

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

Premium Online Series

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

DC POWER SUPPLIES DNX 110/220 V

PRODUCT PRESENTATION PROTECT D.1000 D.3000 APRIL 2012 DATA&IT, SBU C-UPS, PM/SR

100% electricity. Power factor correction components

Back-UPS RS 550 Installation & Operation

FUSELESS ists C,H,K & G

SLI 15 INVERTER SERIES, 1500 W

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

MP7. Uninterruptible Power Supply

SagFighter Active Voltage Conditioner / Sag Ride Through (SRT)

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

Buffered Power Supply PS-30DR v1.0

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

DGBV-EP DIGITAL GENERATOR AND GENERATOR-TRANSFORMER UNIT PROTECTION. Field of application

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

ADJUSTABLE SPEED DRIVES. Q9 Series

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

RT7-48V/6kW Specification

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

The International Power Quality Resource

Q9 ASD LOW VOLTAGE DRIVE

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

Siprotec 7ST61 / 7ST63

GE Critical Power. Single Phase UPS Overview. 1 Gabriele Andrighetti

ASCO ASM (Active Surge Monitor) Surge Protection that Monitors, Measures and Manages

ekor.rps Multifunctional protection unit Volume 3 of 3: ekor.rps-tpc General instructions IG-150-EN, version 04, 03/10/16 LIB

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

MIC-2 Multi-instrument DATA SHEET

Purpose of High Voltage Circuit Switchers

Installation and Operation Manual Back-UPS BR900G-RS

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack, USB, DB9 Serial, LCD

POWER SAVER METER USING MICROCONTROLLER TO SAVE ELECTRICITY UPTO 30-40%

SmartPro 120V 1kVA 650W Line Interactive Sine Wave UPS, Tower, USB, DB9 Serial

RT4B-110V/12A RECTIFIER

Numerical motor protection in medium voltage networks Motor Protection and Control REM620

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, SNMPWEBCARD Option, LCD Display, USB, DB9 Serial

UMG 96RM. UMG 96RM Universal measurement instrument. Areas of application

1. Introduction External description Front and Rear Panel The LCD screen Alarm Conditions...6

Power Supplies. Chapter The McGraw-Hill Companies, Inc. All rights reserved. Mike Meyers CompTIA A+ Guide to Managing and Troubleshooting PCs

Medium Voltage Metal-Enclosed Thyristor-Switched Harmonic Filter Banks

Power Quality of Commercial Buildings - Advanced

Testing Instruments Manufactured by

- Electronic Limit Switches - Very Accurate - Easy to use - Robust - Dependable - High Resolution - Non Contact Measurement - Wide Temp.

DKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY

High Impedance Protection Relay SPAE010, SPAE011. Product Guide

UNITROL 5000 Excitation Systems for Medium and Large Synchronous Machines

Medium Voltage Metal-Enclosed Power Capacitor Banks

Eaton DC Power Solutions

5 to100 Amperes Linear Power Supply/Charger (120 Volt 60Hz) (220 Volt 50Hz)

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

Product Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx

Standard SureVolt Power Conditioner / Voltage Regulator

SmartPro 230V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, Extended Run, SNMP, Webcard, 2U Rack/Tower, LCD, USB, DB9 Serial

SR 469 Motor Management Relay

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

USER MANUAL 2012 V1.1

GPM500 Generator Protection Module

UMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC)

SmartPro 1.5kVA 1000W Line Interactive Sine Wave UPS, 2U Rack/Tower, LCD, USB, RS232, EPO, 120V

ADJUSTABLE SPEED DRIVES. QX7 Series. HVAC 18-Pulse. Phone: Fax: Web:

BUILDING MANAGEMENT. OpenBAS-HV-NX10 SERIES CATALOG NUMBER. Description. Features

Circuit Breaker Sentinel (CBS) for SF 6. power circuit breakers

ekor.stp Programmable transfer unit General instructions IG-164-EN, version 04, 06/04/2017 LIB

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

Reyrolle Protection Devices. 7SG118 Argus 8 Voltage & Frequency Relay. Answers for energy

RT9-48V/1.4kW Rectifier Specification

UR Universal Relay Series

SMARTONLINE E3 UPS SYSTEMS

Residual overvoltage relay

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

GE Multilin 350 Feeder Protection Relay Specifications

Transcription:

Product Ranges 90Amp 6000Amp Energy Saving from Voltage Reduction The Digit@l ES Energy Saver is a specially designed voltage stabilizer that allows for the voltage received by the distribution system to be adjusted to the voltage for which the load has been designed. Digit@l ES optimizes the performance of the supplied equipment, thus obtaining lower consumption, energy saving, cost reduction and longer life expectancy. While a traditional voltage stabilizer is designed to compensate a variation of the input voltage within a certain range (for example, ±20% of the nominal voltage), Digit@l ES is specially developed to reduce the input voltage to a lower level, while still maintaining the stabilizing properties. Digit@l ES is therefore equally efficient and reliable, but more cost-efficient for this specific purpose. EXISTING SITUATION ADDITION OF A SIMPLE OPTIMIZER ADDITION OF Digit@l ES 277V 250V The standard configuration provides for an output phase voltage adjustable from 250V to 277V accepting an input voltage up to +15% higher than the output voltage. Digit@l ES is available in three different versions: BASIC low to medium rating (90A to 500A) with simple design and control electronics, but costefficient and reliable performance. PLUS medium rating range (160A to 500A); sophisticated control system, user-friendly control panel with status and alarm signals, local PC connectivity. ADVANCED availability of very high rating (up to 6000A); top of the range control system, local display showing setting and working parameters, user-friendly control panel with status and alarm signals, local USB connectivity and possibility of remote control of the unit. VOLTAGE OPTIMIZATION LOAD SUPPLIED AND MAINTAINED AT OPTIMUM VOLTAGE LEVEL INDPENDENT MANAGEMENT OF EACH PHASE ± 0.5% OUTPUT ACCURACY AUTOMATIC & CONTINUOUS OPERATION PLUG AND PLAY SOLUTION tame your power keep your profits

BASIC 90 500 Amps The Digit@l ES BASIC Can be considered as the entry level energy saving stabilizer. High performance is combined with design and control features able to satisfy even low budget projects. The main characteristics are listed below: Selectable output voltage (430V, 460V, 480V) Microprocessor-based control board for each phase Independent regulation on each phase Regulation principle based on the rms voltage and insensitivity to harmonics in the supply Admitted load range 0 100% Not influenced by the load power-factor No introduction of harmonic distortion in the output voltage Three-phase and single-phase load admitted Up to 100% load unbalance admitted Toroidal voltage regulators Thermal sensor on the control card; Output class II SPD protection from transients; Digit@l ES BASIC

PLUS 160 500Amps The Digit@l ES PLUS The control system is more sophisticated than the BASIC model with Main characteristics: PC selectable output voltage ( from430-480v) Control card fitted with a DSP microprocessor. Independent regulation on each phase Regulation principle based on the rms voltage and insensitivity to harmonics in the supply. Insensitivity to the load power factor. Admitted load range 0 100% Not influenced by the load power-factor No introduction of harmonic distortion in the output voltage Up to 30% harmonic content admitted on the load current. Three-phase and single-phase load admitted Digit@l ES PLUS with manual bypass DSP microprocessor-based control board The control board runs the voltage stabilizer by regulating each phase independently. The board also monitors the output currents and generates an alarm in case of overcurrent. Under normal working conditions, the output voltage is maintained stable with accuracy equal to ±0.5% in relation to the rated voltage. The control of the stabilizer uses software that digitizes all the parameters (full digital control). The board is fitted with a DSP microprocessor (Digital Signal Processor) that reads line voltage, settings, motor currents and inputs and drives directly the motor by imposing direction and speed. On the basis of the motor current, the board also activates the protections against overload and short-circuit for the motor itself. The following components are connected to the base board: User interface LED signalling board Super-capacitor boards for adjusting to minimum voltage position in case of blackout

PLUS 160 500Amps continued Protections for Digit@l ES PLUS Protection In case of Achieved through Voltage reset to the minimum value Black-out Super-capacitor banks mounted on the base board Motor rotation stop Motor overloaded Base board control Motor rotation stop Motor short-circuit Base board control Overload on the voltage regulator Excessive current flowing through the regulator Circuit breaker with thermal and magnetic release. Roof fans activation Ambient temperature increase Adjustable thermostat Protection of auxiliary circuits Circuit overload Fuses Base board protection Board overload Fuses Overvoltage Transients & spikes Output Class II SPDs External Control Panel The panel provides the stabilizer status via data and alarms. Instrumentation Input and output digital multimeters. Each multimeter is provided with an RS485 output for PC connection. The readings are sequentially displayed by pressing the instrument s pushbuttons. Phase LEDs (from the top) Colour Function 1 blinking Card supplied and functioning 2 red Increase limit switch 3 yellow DC motor in increasing mode 4 yellow DC motor in decreasing mode 5 red Decrease limit switch Alarm LEDs (from the Function top) 1 Output voltage below the set minimum threshold 2 Output voltage above the set maximum threshold 3 Output current above the set maximum threshold 4 Stabilisation OFF 5 Internal overheating Any abnormal functioning generates an acoustic alarm that can be silenced by pressing the relevant button below the alarm LEDs.

ADVANCED 400 6000Amps Digit@l ES ADVANCED Characteristics Output voltage reduced and stabilized to the desired value with ±0.5% accuracy High power availability High reliability and ruggedness Overload capacity up to 2 x In Inrush current capacity up to 10 x In use with asymmetrical input supply and single-phase loads or unbalanced three-phase loads; functionality based on the rms voltage and not on average voltage. This type of control can supply the load with a correctly stabilized voltage even with non-sinusoidal waveform input. Such waveforms are caused by the presence of (for example) part wave rectifiers, transformers with saturated core, non-linear loads, pulses, transients, etc. Digit@l ES ADVANCED regulation performed independently on each single phase (with reference to the neutral, which must be available and connected); fully functioning with load charge variable from 0 to 100% and 100% phase unbalance. up to 30% harmonic content admitted on the load current. insensitivity to the load power factor no harmonic distortions generated on the output voltage absence of batteries and consequent easy storage and handling remote monitoring Main components and working principle The main components of the unit are a three-phase buck/boost transformer, a motorised three-phase autotransformer with continuously variable transformer ratio (voltage regulator) and a microprocessor-based control system. The control system refers the output voltage value to the set nominal value If the voltage is outside the accuracy range (±0.5%), the control drives the voltage regulator gear-motor. By doing so the regulator rollers change their position thus varying the voltage drawn and supplied to the buck/ boost transformer primary winding. When the secondary voltage of the buck/boost transformer is in phase or in opposition to the supply, the voltage drawn from the regulator is added or subtracted to the supply voltage, thus compensating the variations.

ADVANCED 400 6000Amps DSP microprocessor-based control board The control board runs the voltage stabilizer by regulating each phase independently. The board also monitors the output currents and generates an alarm in case of overcurrent. Under normal working conditions, the output voltage is maintained stable with accuracy equal to ±0.5% in relation to the rated voltage. The control of the stabilizer is performed totally through software that digitizes all the parameters (full digital control). The board has two DSP microprocessors (DIGITAL SIGNAL PROCESSOR): the first one works as a controlling CPU and the second as a measuring CPU. Using both microprocessors, the board reads line voltage, settings, motor currents and inputs then drives each motor directly by imposing direction and speed. On the basis of the motor current, the board also activates the protections against overload and short-circuit for the motor itself. The base board controls also the activation of the roof fans. A third microprocessor (Called a bodyguard CPU) supervises the output voltage by detecting and signalling abnormal situations The following components are connected to the base board: communication board for establishing the remote communication of working mode data via Ethernet connection or GPRS modem User interface LED signalling board Super-capacitor boards for adjusting to minimum voltage position in case of blackout. Every Digit@l ES ADVANCED can be monitored locally via a PC connection or remotely through the remote communication card. USB ports allow for easy download of the data stored in the base board memory and update of the relevant software version. Protection Protection In case of Achieved through Voltage reset to the minimum value Black-out Super-capacitor banks mounted on the base board Motor rotation stop Motor overloaded Base board control Motor rotation stop Motor short-circuit Base board control Overload on the voltage regulator Excessive current flowing through the regulator Base board control. While the protection is active, the red alarm LED 'Stabilization off' on the front panel is on. The base board operates in order to have the output voltage equal to the input voltage. Sets of roof fans activation Ambient temperature increase Thresholds set via PC or local display Protection of auxiliary circuits Circuit overload Fuses Base board protection Board overload Fuses Protection of the fan relays mounted on the base board Board overload Fuses Overvoltage Lightning Input Class I SPDs Overvoltage Transients & spikes Output Class II SPDs

ADVANCED 400 6000Amps Remote communication system data analysis Ethernet online assistance GPRS modem Factory Service The communication card manages the remote connection to the voltage stabilizer. The information on the status of the stabilizer can be transferred via Ethernet connection, GPRS modem or locally via a USB drive. Data can be analyzed from a remote location, which allows for active monitoring the functioning mode and, if necessary, altering the setting of some parameters wherever the unit might be installed. Downloading and uploading software, data and functioning parameters can be carried out either locally or remotely. The card is mounted on the rear side of the user interface panel and uses the tools available: local display (showing alarms, setting parameters and connection data); keypad for surfing the menu into which information is organized and USB drives for data exchange and software updating operations The card consists of two parts: upper card, which hosts the CPU, the USB line (transferred onto the user interface panel), the Ethernet line and the flash memory for storing data. lower card, which supplies the upper card, hosts the RS485 connections to the input/output instruments, interfaces the local display and the GPRS modem, receives the data input from the keypad and hosts a Real Time Clock (RTC).

ADVANCED 400 6000Amps External Control Panel Instrumentation Input and output digital multimeters for both input and output lines to be monitored. Each multimeter is provided with an RS485 output for PC connection. The readings are sequentially displayed by pressing the instrument s push-buttons. Phase LEDs (from the top) Colour Function 1 blinking green Card supplied and functioning 2 red Increase limit switch 3 yellow DC motor in increasing mode 4 yellow DC motor in decreasing mode 5 red Decrease limit switch Keypad Used to surf through the menus available on the local display. Display Shows the stabiliser status indicating alarms, setting parameters and connecting data. USB ports Used to update the base board software and download the stored data). TX/RX SERVICE ROLLER OVERHEATING (from the top) 1 2 Alarm LEDs Function Output voltage below the set minimum threshold Output voltage above the set maximum threshold Output current above the set maximum 3 threshold 4 Stabilization OFF 5 Internal overheating Additional LEDs Function ON when the base board is communicating to a local PC ON if maintenance is required ON if the temperature on the rollers is higher than 90 C Any abnormal functioning generates an acoustic alarm that can be silenced by pressing the relevant button below the alarm LEDs. tame your power keep your profits 3075, 14th Avenue Unit13 Markham, Ontario L3R 0G9 Canada Tel: 416-849-2299 US Tel: 440-290-4499 Fax: 416-849-2298 www.omniverter.com info@omniverter.com 0816