to 12a Added Standard and Electrical requirements for UL table 1.1

Similar documents
Added Standard and Electrical requirements for UL table Switching-off inductive loads 1.2

VARAN-INTERFACE VAC 012

DIAS Interface Module VARAN DIV 511

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

VARAN Bus Coupler Module VBC 021 For connecting two VARAN bus systems

VARAN Splitter Module VSV 041

Original operating instructions Safety relay with relay outputs G1501S / / 2016

VARAN Splitter Module VSV 043

C-DIAS Digital Input Module CDI 161 with 16 inputs

TSY 041 Training System Extension Motion

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

VARAN Splitter PROFINET VSP 044

Expansion Module HZS 541-1S

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

DC S-DIAS Axis Module

VARAN Splitter PROFINET VSP 042

AS-i Safety Relay Output Module with Diagnostic Slave

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

AS-i Safety Relay Output Module with Diagnostic Slave

VARAN Digital Combined Module VDM 086

MDM 011-Z1 Regen Resistor

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

HZS Internal Controller Expansion

Protected VARAN Digital Mixed Module PVDM 086

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

TXM1.8RB. TX-I/O Blinds module

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Welcome to the overview of ACS880 functional safety, FSO-11 Safety functions module.

Original operating instructions Fail-safe inductive sensor GG711S

Original operating instructions Fail-safe inductive sensor GI712S

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

C-DIAS VARAN Control Module CIV x VARAN-In 1 x VARAN-Out (Optional Ethernet (VtE))

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

PSR DC/ESP4/2X1/1X2

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Operating instructions. Speed monitor D / / 2014

MSR178DP. Description. Features. Specifications

VARAN Manager PCI Insert module PCV 521 Versatile Automation Random Access Network

Datasheet - MZM 100 B ST2-1P2PW2RE-A

SNO 4003 K plus. Areas of application for the unit. Connection circuit diagrams. Intended use. Competent persons. Equipment and functional description

Phone: Fax: Web: -

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC Functional Safety

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

DM 161 S-DIAS Digital Mixed Module

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Datasheet - MZM 100 B ST-1P2PW2REM-A

TO 161 S-DIAS Digital Output Module

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

Controller CMXH. Description STO. Safe Torque Off (STO) [ ]

PSR UC/ESAM4/3X1/1X2/B

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

MINI-PS AC/10-15DC/8

Industrial Safety Systems

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Internal Buffer/Boiler Module HZS 534

Datasheet - AZM300Z-ST-1P2P-A

ISE 021 S-DIAS Interface Module RS232 / RS485

Safety automation solutions

AS-i Safety Output Module, IP20

AO 081 S-DIAS Analog Output Module

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

C-DIAS EtherNet/IP Slave CIP 022

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

PHOENIX CONTACT - 01/2007

Making Hazardous Operations Safe and Productive

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Demonstration Case BENNING DB 1

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

Bul. 440R Guardmaster Safety Relays (DI, DIS, SI, CI, EM, and EMD) Selection Guide

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

Technical Data. C-DIAS-MULTI l/o MODULE CIO 013

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

Safety modules. 8/4 inputs PROFIsafe S20-PSDI8/4

XPSMCMDO Digital output pairs expansion modules with screw term

PHOENIX CONTACT - 07/2006

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Application Note. AC500-S Usage of AC500 Digital Standard I/Os in Functional Safety Applications up to PL c (ISO )

Operating instructions. Switching amplifier DN0210 DN / / 2015

ICA 012 S-DIAS Interface Module CAN

XPSMCMMX inputs 2 output pairs expansion module with screw term

Transcription:

Document changes and version status C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 Change date Affected page(s) Changes/expansions/corrections Version 19.12.2013 12 to 12a Added Standard and Electrical requirements for UL table 1.1 31.01.2018 5, 8, 9, 13 8 13 14 Removed standard IEC 61508 Added amendments Category 4 and EN Added chapter Conformity with EU Standards Added amendment EN (62061) Added Cat. 4 Added unit 1/h on PFH D value Changed value from 5.13 to 5.13E-09 Changed EMC resistance to 61000-6-2:2005 1.2 05.10.2018 11 Note cable capacitance and cable resistance added 1.3 1.3 Page 1

CSDI 162 C-DIAS SAFETY DIGITAL INPUT MODULE Contents Directory of Illustrations... 3 Directory of Tables... 3 Explanation of Safety Symbols... 4 Documentation Note... 4 Delivery Condition... 4 Operator Due Diligence... 4 Test Signals for Cross-Circuit Detection... 5 Installation... 5 General Instructions for Operating the Safety Modules... 5 The C-DIAS bus and Connector Layout... 6 C-DIAS Safety Digital Input Module CSDI 162... 8 Module Description... 8 Designated Use... 9 Mechanical Dimensions... 10 Technical Data... 11 Input specifications... 11 Specifications for the cross-circuit detection signal outputs... 11 Electrical requirements... 12 The Safety modules' electrical supply must also be provided over the C-DIAS bus. A different type and method of supplying energy is not allowed... 12 Safety Conformity... 13 Conformity with EU Standards... 13 Functional safety standards... 13 Safety-relevant parameters... 13 Environmental conditions... 14 Miscellaneous... 15 CSDI 162 Circuit... 16 Page 2 05.10.2018

C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 LED Display... 17 Connector Layout... 18 Connector Plug Coding... 20 Error Response... 22 Restart Errors... 22 Troubleshooting with the SafetyDesigner... 23 Correcting a wiring error... 23 Input Circuit... 24 Practical Example of a Circuit... 25 Requirements... 25 Implementation... 26 Connection Diagram... 27 Directory of Illustrations Fig. 1: Example of a minimum system for a safety-related control... 6 Fig. 2: CSDI 162... 8 Fig. 3: Mechanical dimensions... 10 Fig. 4: CSDI 162 circuit... 16 Fig. 5 : Connector plug coding... 20 Fig. 6: Simplified status diagram... 22 Fig. 7: Input circuit structure... 24 Fig. 8: Simplified representation of the processing machine... 25 Fig. 9: Example structure diagram... 26 Directory of Tables Table 1: C-DIAS bus connector layout... 6 Table 2: Input specifications... 11 Table 3: Clock output specifications... 11 Table 4: Electrical requirements... 12 Table 5: Safety parameters... 13 Table 6: Environmental conditions... 14 Table 7: Miscellaneous... 15 Table 8: LED Display... 17 Table 9: Connector layout... 19 Table 10: Example schematic... 27 1.3 Page 3

CSDI 162 C-DIAS SAFETY DIGITAL INPUT MODULE Explanation of Safety Symbols This symbol identifies important or additional information in relation to the operation of the individual components. This symbol identifies danger for personnel, the environment or equipment. If safety instructions are not observed, it can result in environmental or equipment damage and/or pose a danger to the life and health of personnel. Documentation Note This documentation is intended exclusively for trained personnel in control and automation technology. For installation and the initial start-up of individual modules or the entire Safety application, the instructions and explanations in this documentation must be followed explicitly. Delivery Condition The individual SIGMATEK Safety components are delivered in specific hard and software configurations. Any change of this configuration that exceeds the options specified in this documentation, is unauthorized and invalidates the warranty from SIGMATEK GmbH & Co KG. Operator Due Diligence The operator must ensure that The components are used for their designated purpose only. The components are operated in error-free, fully functional condition only. Only sufficiently qualified and authorized personnel operate the components. The documentation is complete and in readable condition and available at the site of operation. Page 4 05.10.2018

C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 Test Signals for Cross-Circuit Detection The module sends pulses in cyclic time intervals to detect a crossed circuit in the outputs. When selecting the actuators, keep in mind that these pulses do not activate the actuators or trigger any diagnostic messages. The pulse signals cannot be deactivated or configured. Cross-Circuit Detection Please keep in mind that the cross-circuit detection only functions correctly when it is correctly wired and configured. This applies equally to in- and outputs. Installation Before assembling, disassembling or wiring the module, put the entire system in a safe, voltage-free condition. The module must be mounted in a control cabinet or terminal box for operation. General Instructions for Operating the Safety Modules In the Safety System handbook, the following topics to be observed are covered: System requirements Performance level e according to EN ISO 13849 and/or SIL 3 according to EN 62061 Safety guidelines EMVG Function and operation Wiring To power the Safety modules correctly, the C-DIAS bus must be used (see below). The construction and structure are shown in the following illustration. The appropriate module carriers for the C-DIAS bus are, for example, CMB 021/041/081 with 2, 4 or 8 slots for C-DIAS modules respectively. The important thing is that the slot framed in red shown in the picture is intended for a PLC or coupler module. A C-DIAS IPC (Compact DIAS Industrial PC) is typically used as the PLC, while for example, a CIV 512 can be used as the coupler module. In the latter however, a connection to a PLC over the VARAN bus is required. 1.3 Page 5

CSDI 162 C-DIAS SAFETY DIGITAL INPUT MODULE The C-DIAS bus and Connector Layout A Signal B Signal C Signal 1 CDIAS_/MS 1 CDIAS_/RES 1 ------ 2 CDIAS_EE_A2 2 CDIAS_EE_CLK 2 CDIAS_EE_DAT 3 CDIAS_EE_A1 3 CDIAS_SYNC 3 CDIAS_EE_IRQ 4 CDIAS_EE_A0 4 CDIAS_RDY 4 CDIAS_/DEN 5 ------ 5 CDIAS_/RD 5 CDIAS_/WR 6 ------ 6 CDIAS_A6 6 CDIAS_A7 7 ------ 7 CDIAS_A4 7 CDIAS_A5 8 ------ 8 CDIAS_A2 8 CDIAS_A3 9 ------ 9 CDIAS_A0 9 CDIAS_A1 10 ------ 10 CDIAS_D6 10 CDIAS_D7 11 ------ 11 CDIAS_D4 11 CDIAS_D5 12 ------ 12 CDIAS_D2 12 CDIAS_D3 13 +24V_CDIAS 13 CDIAS_D0 13 CDIAS_D1 14 +5V_UNFUSED 14 +5V_UNFUSED 14 +5V_UNFUSED 15 GND (internal) 15 GND (internal) 15 GND (internal) 16 GND (external) 16 GND (external) 16 GND (external) Table 1: C-DIAS bus connector layout Fig. 1: Example of a minimum system for a safety-related control Page 6 05.10.2018

C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 The minimal system of a safety-related control, formed as shown above, with a C-IPC a CMB 081 and a Safety CPU type CSCP 012. The safety-related application is found in the Safety CPU and can run independently of the C-IPC. The C-IPC, however, is required to power the bus correctly and cannot be removed. In addition, it is also needed to establish the communication between the Safety CPU and the design tool (SafetyDesigner). On the C-IPC and coupler modules, connectors are provided over which the C-DIAS bus must be externally supplied with a voltage of 24 V. The external supply for the output and clock drivers should be independent of the external C-DIAS bus supply (see below) With the help from an SD card with a valid configuration, the Safety CPU can also be configured independently of the design tool (SafetyDesigner). More information hereto can be found in the chapter "Handling the micro SD card". With regard to the configuration using the design tool, the SafetyDesign handbook must be consulted. 1.3 Page 7

CSDI 162 C-DIAS SAFETY DIGITAL INPUT MODULE C-DIAS Safety Digital Input Module CSDI 162 Module Description The Safety input component series has the Safety integrity level SIL3 and/or SIL CL 3 according to (IEC 62061) and/or Performancelevel e (PL e) / Category 4 (EN ISO 13849). The Safety-CPU component series has: 16 safe inputs (IEC/EN 61131) Doubled clock output signal (short-circuit proof) The Safety inputs are used for reading 16 Safety actuator signals (emergency stop, confirmation button etc.). The Safety input module has 2 non-safety signal outputs, TA and TB, to test inputs and detect cross-circuit errors (i.e. emergency stop). Fig. 2: CSDI 162 The Safety input module CSDI 162 is suited for use in systems with optional modules and interface variables in accordance with the system hand book version 1.5, sections 1.6, 7.1 and 7.2. To use the Safety input module in an application, a Safety CPU module that regulates the synchronized communication with the Safety modules using safe bus telegrams is also required. This also includes Processing the safe application and The distribution of configuration data to remote Safety modules. Page 8 05.10.2018

Designated Use C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 The CSDI 162 Safety module is designed for use in Safety-related applications and meets the required conditions for Safety operation in compliance with Perfomancelevel e (PL e), according to EN ISO 13849 and/or SIL 3 according to EN 62061. It is usually used in conjunction with other Safety modules such as CSCP 012 and CSTO 082, for example. Installation, mounting, programming, initial start-up, operation, maintenance and discarding of Safety modules can only be performed by qualified personnel. Qualified personnel in this context are people, who have completed training or have been trained under supervision of qualified personnel and have been authorized to operate and maintain safety-related equipment, systems and facilities in compliance with the strict guidelines and standards of Safety technology. More information on Standards etc. can be found in the Safety System Handbook. For your own safety and the safety of others, Use Safety modules for their designated purpose. Correct EMV installation is also included in the designated use. Non-designated use consists of Any change made to the Safety modules of any kind. The use of damaged Safety modules. The use of the Safety module outside of the instructions described in this handbook. The use of the Safety module outside of the technical data described in this handbook. 1.3 Page 9

CSDI 162 C-DIAS SAFETY DIGITAL INPUT MODULE Mechanical Dimensions Fig. 3: Mechanical dimensions Page 10 05.10.2018

C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 Technical Data Input specifications The inputs are type 1 according to IEC/EN 61131 Number of 16 Input voltage +24 V DC Input voltage range Minimum +18 V Maximum +30 V Signal level Low: +5 V High: +15 V Switching threshold Input current Input delay Typically +11 V 5 ma at +24 V Maximum 2.5 ms Table 2: Input specifications Specifications for the cross-circuit detection signal outputs Number of 2 Rated output voltage +24 V DC Output voltage range Minimum +18 V Maximum +30 V Output current Miscellaneous 100 ma at +24 V Short-circuit proof Table 3: Clock output specifications When using the digital inputs with the clock outputs for cross-wire detection for long cable lengths, it must be ensured that the cable capacitance from the clock output to the digital input does not exceed a value of 75 nf in relation to GND and that the cable resistance does not exceed a value of 250 Ω, so that the cross-wire detection does not detect a wiring fault if the wiring is correct. 1.3 Page 11

CSDI 162 C-DIAS SAFETY DIGITAL INPUT MODULE Electrical requirements The Safety modules' electrical supply must also be provided over the C-DIAS bus. A different type and method of supplying energy is not allowed. The C-DIAS bus system's external 24 V supply voltage must be generated by a PELV power supply. Rated supply voltage +24 V DC (C-DIAS bus) Supply voltage range including ripple Minimum +18 V Maximum +30 V Voltage supply from C-DIAS bus Current consumption of C-DIAS bus (+5 V supply) Current consumption of C-DIAS bus (+24 V supply) Maximum interrupt time for voltage interruptions Standard +5 V Typically 50 ma Typically 90 ma 10 ms UL 508 (E247993) Table 4: Electrical requirements Electrical requirements for UL IMPORTANT: The device was tested in accordance with the UL 508 Norm as a low voltage limited power circuit (LVLC - limited voltage/limited current). To meet the standard requirements, the device must be powered by a galvanically isolated source (+24 V DC), which is protected with a UL-certified 4 A fuse (UL 248) in the secondary circuit. If the device is powered by two galvanically isolated sources, one to power the electronics and one for the frequency output, each source must be equipped with a UL-certified 4 A fuse (UL 248) in the secondary circuit. Input Output (General use Ampere Rating) 18-30 V DC (24 V DC 16 x 5 ma) 16 x 5 ma at +24 V Cross-circuit detection signal output Page 12 a 05.10.2018

C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 Safety Conformity Conformity with EU Standards The module has been designed in accordance with the following European Union directives: 2006/42/EG 2014/30/EU 2011/65/EU Machinery Directive EMC Directive RoHS Directive Functional safety standards - EN/IEC 62061 SIL 3 or SIL CL 3 - EN ISO 13849 PL e / Cat. 4 Configuration: 2-channel redundant (diverse) Safety-relevant parameters Diagnostic coverage DC [%] 95.7 Probability of failure per hour PFHD [1/h] 5.13E-09 Mean time to dangerous failure MTTFD [years] symmetrized 472 Proof Test Interval [years] 20 Table 5: Safety parameters Please note: The parameters shown are only applicable with the simultaneous parallel use of two inputs. 1.3 Page 13

CSDI 162 C-DIAS SAFETY DIGITAL INPUT MODULE Environmental conditions Storage temperature -20 to +85 C Environmental temperature 0 to +55 C Humidity EMV stability 0 to 95 %, uncondensed According to EN 61000-6-2:2005 (industrial area) Raised requirements according to IEC 26061 Shock resistance EN 60068-2-27 15 g Protection Type EN 60529 IP 20 Table 6: Environmental conditions Page 14 05.10.2018

C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 Miscellaneous Article number 12-891-162 Hardware version 1.x Table 7: Miscellaneous 1.3 Page 15

CSDI 162 C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 Circuit For the functions and LED display, see the following chapter "LED Displays". Fig. 4: CSDI 162 circuit Page 16 05.10.2018

C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 LED Display The LED display lights continuously to indicate that the in- and outputs are active. Label Color Function Display 1 16 Green Digital inputs 1 16 (connector X1, X2, X3, X4) Fast blinking frequency (wiring error, cross circuit... ) DC Green DCOK +24 V Indicates that the +24 V supply for the clock signals is within the defined limits. RN Green RUN Indicates the time-unlimited (LED "ST" off) operational mode ST Yellow Status - Lights permanently: The module is currently in service mode - Slow blinking frequency: The module is in the Idle or Check configuration (because the mode transition can be very fast, the blinking signal is normal not noticed. E Red Error - Lights permanently: the module is in error mode Table 8: LED Display - Fast blinking frequency: Serious error; communication with the module is no longer possible (CANNOT be read with the SafetyDesigner 1.3 Page 17

CSDI 162 C-DIAS SAFETY DIGITAL INPUT MODULE Connector Layout Module connection Label Pin Function Connection X1: digital inputs (Group G1) DI1 X1 / 1 Digital Input 1 DI2 X1 / 2 Digital Input 2 DI3 X1 / 3 Digital Input 3 DI4 X1 / 4 Digital Input 4 X2: digital inputs (Group G2) DI5 X2 / 1 Digital Input 5 DI6 X2 / 2 Digital Input 6 DI7 X2 / 3 Digital Input 7 DI8 X2 / 4 Digital Input 8 X3: digital inputs (Group G3) DI9 X3 / 1 Digital Input 9 DI10 X3 / 2 Digital Input 10 DI11 X3 / 3 Digital Input 11 DI12 X3 / 4 Digital Input 12 X4: digital inputs (Group G4) DI13 X4 / 1 Digital Input 13 DI14 X4 / 2 Digital Input 14 DI15 X4 / 3 Digital Input 15 DI16 X4 / 4 Digital Input 16 Page 18 05.10.2018

C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 X5: clock signal outputs A X5 / 1 Clock Output A B X5 / 2 Clock Output B + X5 / 3 +24 V (supply for clock signal output) - X5 / 4 GND Table 9: Connector layout The complete C-DIAS connector set (5 connector plugs with spring terminals; Phoenix Contact: FK-MCP 1,5/ 4-ST-3.5) is included in delivery of the C-DIAS module. 1.3 Page 19

CSDI 162 C-DIAS SAFETY DIGITAL INPUT MODULE Connector Plug Coding Plug X1 Plug X2 Plug X3 Coding pin 1 (Pin 1) Plug X4 Socket X1 Coding pin 2 (Pin 2) Socket X2 Coding pin 3 (Pin 3) Socket X3 Coding pin 4 (Pin 4) Socket X4 Fig. 5 : Connector plug coding Page 20 05.10.2018

C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 The Phoenix connector sets used are coded at the factory to avoid confusing the connections. A red coding pin is thereby placed in the socket. Concurrently, the protruding "nose" is removed from the corresponding pin in the plug. The respective plug can therefore only be inserted into the corresponding socket. Connector plug coding: Pin 1 in plug/socket X1 Pin 2 in plug/socket X2 Pin 3 in plug/socket X3 Pin 4 in plug/socket X4 The X5 plug is not coded. 1.3 Page 21

CSDI 162 C-DIAS SAFETY DIGITAL INPUT MODULE Error Response In the event of an error, please consult the chapter "LED Displays", as important information on the runtime status of the system can be derived from the status and error display. Since errors in general are of a complex nature, do not perform a diagnosis based on the LEDs alone (consult the corresponding chapter in the Safety System Handbook as well). For an exact error analysis, the SafetyDesigner must be used. Restart Errors The following diagram shows the response of the Safety input module during restart. Wiederanlauf Restart POST Flash Safe-CPU ist CPU leer is Empty Service Mode Idle Check Config. Mode Error Mode dauerhaft Continously ON on dauerhaft Continously ON on ST E Op. Mode dauerhaft Continously ON on RN Fig. 6: Simplified status diagram Page 22 05.10.2018

C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 a) During restart, the Safety input first runs the POST (Power On Self Test). In the POST, whether the Safety input is configured or not is determined. If the Flash memory in the Safety input is empty, it changes to the service mode and switches the status LED (ST) to continuously on. b) If the Flash memory of the Safety input contains a configuration, it goes into the idle / Check Configuration Mode. The transition into the OP mode occurs so fast that the blinking of the ST LED is not seen. c) A change to the error status can also occur from the POST and (Temp.) OP. mode if other (internal) errors are detected or errors in remote modules occur. The analysis of these errors however, requires the use of the SafetyDesigner. Troubleshooting Check all modules in the system for completeness and type conformity Check that all modules are error-free Check all connector cables Cancel the error with the QUIT_ERROR command If the Safety input module remains in the error status after the QUIT_ERROR command has been executed, it must be retested using the SafetyDesigner. Troubleshooting with the SafetyDesigner Connect the SafetyDesigner Debug the system using the SafetyDesigner. Correcting a wiring error When a wiring error is determined, a controlled deactivation of the system is required, which must then be turned off. The system can only be rewired when no power is applied. 1.3 Page 23

CSDI 162 C-DIAS SAFETY DIGITAL INPUT MODULE Input Circuit Digital input Digital input (1 to 16) Internal logic Fig. 7: Input circuit structure Page 24 05.10.2018

Practical Example of a Circuit C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 The following diagram shows the schematic for a processing machine. To implement the application, the following basic requirements must be met. Requirements R1 The installation can only be started manually with the start button S1. For crosscircuit detection, the start button S1 should have a 2-channel connection. R2 The signal lamp P1 should turn on immediately after pressing the start button S1. To activate the signal lamp P1, a safe output can be used. R3 R4 For the power train control of the processing machine, a Safety output should be used on the relay K1. The K1 relay should be set 500 ms after pressing the start button S1. When the Emergency Stop switch S2 is triggered, the power train control of the machine must be turned off within 50 msec. Fig. 8: Simplified representation of the processing machine 1.3 Page 25

CSDI 162 C-DIAS SAFETY DIGITAL INPUT MODULE Implementation For switch S1, the start button, and S2, the Emergency Stop switch, 2 safe inputs are required for each. Two safe outputs are needed for control of the relay K1 and the signal lamp P1. The normally open contacts of the start button S1 are connected to the signal outputs A and B over 2 channels (cross-circuit detection) and wired to 2 safe inputs. The normally closed contacts of the Emergency Stop switch S2, are connected to the signal outputs A and B over 2 channels (cross-circuit detection) and wired to 2 safe inputs. The monitor contact of the K1 relay switch is read back. The following block diagram shows the implementation of the circuit with help from a CSDI 1621 Safety input module and a single CSCP 012 Safety CPU the previously mentioned external components. Here, it is assumed that the both modules are mounted on a correctly installed C-DIAS module carrier. Fig. 9: Example structure diagram Page 26 05.10.2018

Central wiring Control configuration Central wiring Control configuration C-DIAS SAFETY DIGITAL INPUT MODULE CSDI 162 The following schematic shows the corresponding block diagram for the wiring in tabular form. Connection Diagram CSCP 012 Pin Connection 1 Control relay K1 X1 2 Control signal light P1 3 +24 V 4 GND 1 --- X3 2 --- 3 +24 V 4 GND CSDI 162 Connectors Connectors Pin Connection X1 X4 X5 1 Auxiliary contact relay K1 2 --- 3 --- 4 --- 1 Normally open start button S1 (B) 2 Normally open start button S1 (B) 3 Normally closed Emergency Stop S2 (A) 4 Normally closed Emergency Stop S2 (b) 1 Output A 2 Clock output B 3 +24 V 4 GND Table 10: Example schematic 1.3 Page 27

CSDI 162 C-DIAS SAFETY DIGITAL INPUT MODULE Page 28 05.10.2018