User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

Similar documents
Xxxxx Xxxxxx OM-CP-QUADVOLT. OM-CP-OCTVOLT 8-Channel Low Level DC Voltage Data Logger. 4-Channel Low Level DC Voltage Data Logger INSTRUCTION SHEET

Xxxxx Xxxxxx Bridge / Strain Gauge Data Logger

User s Guide. OM-CP-HITEMP140-M12 High Temperature Data Logger with an M12 Probe Connector

Xxxxx Xxxxxx DC Voltage Data Logger

High Temperature Data Logger

User s Guide. OM-CP-HITEMP140X2 High Temperature Dual Probe Data Logger Series

User s Guide. OM-CP-SMR101A-KIT Soil Moisture Data Logger

User s Guide RDXL6SD-USB. Temperature Data Logger with USB. Shop online at omega.com

User s Guide TSD600. Shop online at omega.com SM. For latest product manuals: omegamanual.info

User s Guide TXDIN1700. Universal DIN Rail. Shop online at omega.com SM. For latest product manuals:

FMA-7400/7500 Series Configurator

User s Guide. Series. Communication Manual. Shop online at omega.com SM. For latest product manuals:

User s Guide. OM-HL-SH Series. Single Channel Temperature and Humidity Data Logger, Handheld. Shop online at omega.com

User s Guide. OM-HL-SP Series. Single Channel Temperature and Humidity USB Data Logger, Pen Size. Shop online at omega.com

User s Guide HHSL-101. USB Digital Sound Level Data Logger. Shop online at omega.com SM

User s Guide OM-SGD-28-M. Shop online at omega.com. Smart Graphics Display. For latest product manuals:

OMB-DAQ-TC-RACK OMB-DAQ-2416 OM-NET-1608 OM-USB-32DIO

User s Guide. OM-HL-SP Series Single Channel Temperature and Humidity USB Data Logger, Pen Size. Shop online at omega.com

User s Guide CS8DPT SERIES. Benchtop Controllers. Shop online at omega.com. For latest product manuals:

User s Guide. OM-HL-EH-TC Series Multi-channel Handheld Thermocouple Temperature Data Logger. Shop online at omega.com

User s Guide. OM-HL-SH Series. Single Channel Temperature and Humidity Data Logger, Handheld. Shop online at omega.com

User s Guide OM-DAQXL. Modbus Interface. Shop online at omega.com. For latest product manuals:

User s Guide TX69. Universal Smart Transmitter. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide. DIN-190 and DIN-192 Series. Converter Boxes. Shop online at

Product User Guide PR2000. PR2000 Pressure Data Logger with LCD

OM-DAQXL. Multi-Channel Universal Input Touch Screen Data Logger

Xxxxx Xxxxxx OM-CP-TEMP1000IS-A. Intrinsically Safe Temperature Data Logger with Stainless Steel Enclosure INSTRUCTION SHEET MQS5096/1216

User s Guide D6000 SERIES. Digital Transmitters Modbus RTU, RS-485 Output. Shop online at omega.com

User s Guide HHM-MG300. Wireless TRMS Multimeter and Insulation Tester. Shop online at omega.com

User s Guide. DPU90-CT PC COMM / Sensor Configuration Tool

User s Guide TXUN-KIT. Loop Link USB Communications Interface. Shop online at omega.com

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course! Shop online at omega.com SM

User s Guide TCL Series Portable Sample Cooling Device

User s Guide LVU30 SERIES. Ultrasonic Sensors. Shop online at omega.com. For latest product manuals:

User s Guide HHPT-51. Particle Counter. Shop online at omega.com. For latest product manuals:

User s Guide. DRSL-LPO Series. DIN Rail Loop Powered Isolators. Shop online at omega.com

Product User Guide. OctProcessV2 and QuadProcessV2. QuadProcessV2-3A 4-Channel Low Level DC Current

Shop online at omega.com

User s Guide WTC Shop online at. Wind Tunnel Controller. omega.com For latest product manuals: omegamanual.

User s Guide. CSi8DH SERIES. Benchtop Controllers. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide HHM250. AC Clamp Meter. Shop online at. omega.com For latest product manuals: omegamanual.info MADE IN TAIWAN

Troubleshooting Tips & Procedures. Model 8800 series. GeoNet Wireless

User s Guide. CSi32. Benchtop Controller. Shop online at omega.com. For latest product manuals:

Product User Guide. QuadTemp and OctTemp. QuadTemp 4-Channel Thermocouple Based Temperature Data Logger

User s Guide. OM-CP-PR2000 Pressure Data Logger with LCD Display. Shop online at

User s Guide HH309A. Data Logger Thermometer. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide CT89 SERIES. Temperature Recorder. Shop online at. omega.com For latest product manuals: omegamanual.

User s Guide HH520. Data Logger Thermometer. 4 Channel Type J, K, T, E. Shop online at omega.com

User s Guide HHF-312. Mini Anemometer-Psychrometer With Compass And Memory. Shop online at omega.com SM

Temperature & Process Controller/Monitor CNi8C-EN/DPi8C-EN

User s Guide. Shop online at omega.com. FPD3100-D and FPD3100-D-A Series. 12mm LC Digital Display with Analog Output Options

TM 2. User s Guide. Shop online at omega.com For latest product manuals: CDH-SD11

USB Server User Manual

User s Guide Servicing North America:

OME-SERIES DATA ACQUISITION CARDS

User s Guide. LVR300 Series. Shop online at. Continuous Level Switch System

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA... Of Course!

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA... Of Course!

Bluetooth USB Adapter TALUS. User Guide

OctTemp2000. Data Logger Manual

User s Guide DRSL-DC4. Bipolar Isolated DIN Rail Signal Conditioner. Shop online at omega.com

HiTemp140-FP-TSK High Temperature Data Logger with Flexible RTD Probe and Thermal Shield

User s Guide OM-DAQXL. Multi-Channel Universal Input Touch Screen Data Logger. Shop online at omega.com

User s Guide DP301AN DC VOLTMETER DP301AN-AC VOLTMETER. Shop online at omega.com

User s Guide DP26-TC. Differential Temperature Meter with Thermocouple. Shop online at omega.com

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA... Of Course!

OMEGA. HH504 Digital Thermometer

INSTRUCTION MANUAL. AquiStar GDL. Dissolved Oxygen Datalogger

User s Guide CL532. ma/v Loop Calibrator with Loop Diagnostic. Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course!

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

CL550 - SOFT Software Packages

User s Guide DPG8001 M-5103/0217. Shop online at. General Purpose Digital Pressure Gauge

TR100-A / TR200-A. Temperature / Humidity Data Loggers. Users Manual. For detailed specifications and ordering info go to

omega.com For Other Locations Visit omega.com/worldwide

zpen-1080p Features zpen-1080p Layout

User s Guide LDN-PS. Shop online at. omega.com For latest product manuals: omegamanual.info. solartron

User's Guide. Video Borescope. Model BR100

3-Axis G-Force Datalogger

User s Guide. DRA-RTM-8 ANALOG MULTIPLEXER

Digital Timer Outlet Model No.: EDT-1USA. Questions or Concerns? (855)

DOCKING STATION FOR THE APPLE 13 MacBook

ADVANCED 4/8-PORT SECURE KM SWITCH

User's Guide Video Borescope Model BR200

Bluetooth USB Adapter. Parani-UD100. User Guide

Where Do I Find Everything I Need for Process Measurement and Control? OMEGA... Of Course!

MP3 Speaker USER GUIDE

User s Guide. DP40 and DPF400. Series Indicators RS-232/RS-422/RS-485 Serial Communications. Shop on line at

Advanced 8-Port DisplayPort Secure KVM Switch

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

AirPro Surveyor 2 Manual

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7525

TD 600 Thermo-Fastprinter

True RMS AC Voltage/Current Datalogger

Suction Pressure Sensor

User s Guide DP20. Economical Multisignal Meter for Process, Temperatures and Electrical signals. Shop online at omega.com

TrendSense. Instructions for Use. TrendSense and TrendSense Communicator

Advanced 2/4-Port DisplayPort Secure KVM Switch

User Guide. Heavy Duty Differential Pressure Manometer. Model HD750

Data Reporter. Installation-Operation E rev.f

7191AD User Manual. June Daisy Data Displays, Inc Lewisberry Road, York Haven, PA Phone:

Transcription:

User s Guide OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

OM-CP-PRHTEMP2000 Product Overview The OM-CP-PRHTEMP2000 is a pressure, temperature and humidity data logger with LCD display. The convenient LCD provides access to the current pressure, temperature and humidity readings, as well as minimum, maximum and average statistics. For additional information refer to your OM-CP-PRHTEMP2000 manual and Data Logger & Software Operating Manual. Backlight The backlight uses a significant amount of battery life. Refer to the manual to configure the auto shut-off when not in use. Submergibility The OM-CP-PRHTEMP2000 is rated IP65, which means it is dust tight and can withstand water jets. Set Password To password protect the device so that others cannot start, stop or reset the device: In the Connected Devices panel, click the device desired. On the Device Tab, in the Information Group, click Properties. Or, right-click the device and select Properties in the context menu. On the General Tab, click Set Password. Enter and confirm the password in the box that appears, then select OK. 2

Quick Start Manual Installation Guide Installing the Interface cable - OM-CP-IFC200 Insert the device into a USB port. The drivers will install automatically. Installing the software Insert the Omega Software Flash Drive in an open USB port. If the autorun does not appear, locate the drive on the computer and double click on Autorun.exe. Follow the instructions provided in the Installation Wizard. Device Operation Connecting and Starting the data logger 1. Once the software is installed and running, plug the interface cable into the data logger. 2. Connect the USB end of the interface cable into an open USB port on the computer. 3. The device will appear in the Connected Devices list, highlight the desired data logger. 4. For most applications, select Custom Start from the menu bar and choose the desired start method, reading rate and other parameters appropriate for the data logging application and click Start. ( Quick Start applies the most recent custom start options, Batch Start is used for managing multiple loggers at once, Real Time Start stores the dataset as it records while connected to the logger.) 5. The status of the device will change to Running, Waiting to Start or Waiting to Manual Start, depending upon your start method. 6. Disconnect the data logger from the interface cable and place it in the environment to measure. Note: The device will stop recording data when the end of memory is reached or the device is stopped. At this point the device cannot be restarted until it has been re-armed by the computer. Downloading data from a data logger 1. Highlight the data logger in the Connected Devices list. Click Stop on the menu bar. 2. Once the data logger is stopped, with the logger highlighted, click Download. You will be prompted to name your report. 3. Downloading will offload and save all the recorded data to the PC. 3

OM-CP-PRHTEMP 2000 Product Maintenance Battery Replacement Materials: 9/64 HEX Driver (Allen Key) and a Replacement Batteries (6 AA) 1. Remove the back cover from the device by unscrewing the four screws. 2. Remove the batteries from the compartment. 3. Insert the new batteries as indicated by the diagram on the battery holder. 4. Replace the cover taking care not to pinch the wires. Screw the enclosure back together. Note: Be sure not to over tighten the screws or strip the threads. Recalibration The OM-CP-PRHTEMP2000 standard calibration is one point at 25 C, two points at 25 %RH and 75 %RH and two points at 14.7 PSI and 30 PSI. a reminder is automatically displayed in the software when the device is due. 4

Quick Start Manual OM-CP-PRHTEMP2000 General Specifications Temperature Sensor Temperature Range Pressure Resolution Calibrated Accuracy Pressure Sensor Pressure Range Pressure Resolution Semiconductor (strain guage) 20 C to +60 C (-4 F to +140 F) 0.1 C (0.18 F) +0.5 C/+0.9 F (0 C to 50 C/32 F to 122 F) Semiconductor 0 to 30 PSIA 0.002PSIA Calibrated Accuracy +1.0%FSR; 0.25% at 25 C Humidity Sensor Humidity Range Humidity Resolution Calibrated Accuracy Memory Reading Rate Required Interface Package Internal Semiconductor 0%RH to 95%RH 0.1%RH +3%RH (2%RH @ 25 C Typical) 87,381/channel 1 reading every 2 seconds up to 1 reading every 24 hours IFC200 Baud Rate 115,200 Typical Battery Life Operating Environment Material Dimensions Weight Approvals 1 year with display off, 30 days with continuous LCD and no backlight -20 C to 60 C (-4 F to 140 F), 0%RH to 95%RH (non-condensing) Black anodized aluminum 4.8 in x 3.3 in x 1.25 in (122 mm x 84 mm x 32 mm) 16oz (440g) CE Battery Warning WARNING: RISK OF FIRE OR EXPLOSION. DO NOT RECHARGE, FORCE OPEN, HEAT OR DISPOSE OF IN FIRE. Specifications subject to change. See Omega s terms and conditions at www.omega.com 5

omega.com info@omega.com Servicing North America: U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047 Stamford, CT 06907-0047 USA Toll-Free: 1-800-826-6342 (USA & Canada only) Customer Service: 1-800-622-2378 (USA & Canada only) Engineering Service: 1-800-872-9436 (USA & Canada only) Tel: (203) 359-1660 Fax: (203) 359-7700 e-mail: info@omega.com For Other Locations Visit omega.com/worldwide The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications. WARRANTY/DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 61 months from date of purchase. OMEGA s WARRANTY adds an additional one (1) month grace period to the normal five (5) year product warranty to cover handling and shipping time. This ensures that OMEGA s customers receive maximum coverage on each product. If the unit malfunctions, it must be returned to the factory for evaluation. OMEGA s Customer Service Department will issue an Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be defective, it will be repaired or replaced at no charge. OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specification; misapplication; misuse or other operating conditions outside of OMEGA s control. Components in which wear is not warranted, include but are not limited to contact points, fuses, and triacs. OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA neither assumes responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in accordance with information provided by OMEGA, either verbal or written. OMEGA warrants only that the parts manufactured by the company will be as specified and free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive, and the total liability of OMEGA with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall OMEGA be liable for consequential, incidental or special damages. CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a Basic Component under 10 CFR 21 (NRC), used in or with any nuclear installation or activity; or (2) in medical applications or used on humans. Should any Product(s) be used in or with any nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and, additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in such a manner. RETURN REQUESTS / INQUIRIES Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA S CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be marked on the outside of the return package and on any correspondence. The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1. Purchase Order number under which the product was PURCHASED, 2. Model and serial number of the product under warranty, and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA: 1. Purchase Order number to cover the COST of the repair, 2. Model and serial number of the product, and 3. Repair instructions and/or specific problems relative to the product. OMEGA s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. Copyright 2014 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC. MQS-5031/0516