Voice Alarm System VX-3000 Series

Similar documents
Voice Alarm System VX-3000 Series

Voice Alarm System VX-3000 Series

INTEGRATED VOICE EVACUATION SYSTEM

INTEGRATED VOICE EVACUATION SYSTEM

IP-3000 Series. IP Network Public Address System. Monitoring and setting can be done easily by logging-in to control GUI via browser.

AUDIO MANAGEMENT SYSTEM

INTEGRATED VOICE EVACUATION SYSTEM

TOA Net Price List PROFESSIONAL USER

VM VX SX-2000 Integrated Voice Alarm Management & Evacuation Systems

ex 800A Series ematrix System

EN60849/IEC60849 compliant

MX X 250W AMPLIFIED MASTER UNIT

Automated Remote Messaging ARM-911A RM-911D RM-911W

N-8000 SERIES IP INTERCOM SYSTEM

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

VIPEDIA-12. Cameo specification sheet. Product Description

EN54-16 COMPLIANT HARDWARE BYPASS MICROPHONE PORTS 12 ANALOGUE AUDIO INPUTS 12 GPIO INPUTS & 12 OUTPUTS 12 ANALOGUE AUDIO OUTPUTS

MU 9186R MASTER UNIT WITH ROUTER

INFRARED WIRELESS CONFERENCE SYSTEMS

Contents. Appearance of AC Plug and Voltage CU 314L US UL 120 L V AC

Emergency Voice Evacuation and Mass Notification Systems COOKBOOK

Digital Mixing System D-2000 Series

TOA ELECTRIC CO., LTD.

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console MG10. MG10 is a versatile mixer suitable for a wide range of users and applications.

9000M2 SERIES MODULAR DIGITAL MATRIX MIXER AND MIXER/AMPLIFIERS H IGHLIGHTS

V CHANNEL MODULAR PRE-AMP/MIXER V-9984 REMOTE INPUT MODULE V CHANNEL MODULAR PRE-AMP/MIXER

INFORMATION AMPLIFIER TA-102 OPERATING INSTRUCTIONS TABLE OF CONTENTS

PILOT TONE DETECTION MODULE IMPEDANCE DETECTION MODULE

N-8000 Series IP Intercom System

BASIC PA AMPLIFIER A-1031 A-1061 A-1121 OPERATING INSTRUCTIONS TABLE OF CONTENTS

HCS-5300MA/ 80 Digital Infrared Wireless Conference Main Unit

PRODUCT LINEUP CATALOG

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

Stereo / Mono. Audio Power Amplifier W. Introduction. Applications

W W. Public Address & Voice Evacuation System. Flexible and scalable configuration Fully digitalised audio transmission

INTEGRATED VOICE EVACUATION SYSTEM VX-2000 series

MG12XU Overview Features Technical Data Sheet

IMPORTANT SAFETY INSTRUCTIONS

1073N. Channel Amplifier. User Manual Issue 1.3

IP Intercom System. N-8000 Series. Sounding bells, stamping feet, screaming children yet still be notified clearly and in good time of every danger.

Operating Instruction Manual POWERED MIXER. Model MX-401. Toa Electric Co., Ltd. KOBE, JAPAN

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

Operating instruction Manual POWERED MIXER. Model MX-101. Toa Electric Co., Ltd. KOBE, JAPAN

MIC-2 MKII, Multi-instrument DATA SHEET

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG03

AUTROVOICE MULTIVES EXCHANGEABLE MODULES

MPS01. Paging and Emergency Microphone

CU 6005 DCS 6000 Medium Power Central Control Unit

VM SERIES Rackmount 100V mixer-amplifiers

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

AMP Watt Audio Amplifier with RS-232 and IR Control. User s Manual CUSTOMER SUPPORT INFORMATION

SNC-DF40P High Resolution Minidome Color Camera with 10/100 Base T Ethernet

IP-ZCM. PoE+ IP to Analog Gateway (Zone Controller)

IPCSDTouch-G 1/5. GLOBALCOM.IP Touch Screen Digital Communication Station. IPCSDTouch-H (Handheld Microphone Version) Features. General Description

Overview. Features. Technical Data Sheet 1 / 5. Signal Processor MRX7-D

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG06

Accessories and options

NTSC TOA's Digital Video Recorder series combine high reliability with all the advantages of scalable expansion flexibility.

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Orbis MU 41. Digital Flush Mount Delegate Microphone Unit Order #

IP-9000 IP Network Audio System. Features:

EMS10 - EMS50. Cameo specification sheet. Product Description

TM221CE40T controller M IO transistor PNP Ethernet

MPS10 - MPS50. Modular Paging and Emergency Microphones

A120 A W/240W PA Mixer-Amplifier 70V/100V

Orbis MU 21. Digital Delegate Microphone Unit with Loudspeaker Order #

Data sheet CC 03, Commander Compact (603-1CC21)

MIC-2 Multi-instrument DATA SHEET

The Digital Matrix Platform for Intercom, Audio & IP-Routing. Installation Guide. Artist M Installation Guide Version

TM221CE24R controller M IO relay Ethernet

Operating Manual AMIS60, 60w Mixer Amplifier & AMIS120, 120w Mixer Amplifier

IDA8C. Networkable PAVA system Controller Unit. IDA8 System

ATP-24A/PCI(2.0) ATP-24A/PCI+(2.0) ATP-24A/PCIe(3.0) ATP-24A/PCIe+(3.0) Analog Tap Passive Board

DST-24B/PCI DST-24B/PCI+ DST-24B/PCI(2.0) DST-24B/PCI+(2.0) DST-24B/PCIe(2.0) DST-24B/PCIe+(2.0) Digital Station Tap Board

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

WP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments

U N D & We Supply Sound, Not Equipment. That s Our Corporate Philosophy. Basic Management Policy (Three Confidence) TOA s Environmental Principles

CS-120. Conferencing and Discussion / Interpretation System. Digital Conference System. conference system. CS-120 Series

INTEGRUS. LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker. LBB 3422/20 Integrus Audio Input and Interpreters Module

TM221M16TG controller M IO transistor PNP spring

Vigil 3 Amplifiers. Installation Instructions

xin 4, xio 4x4 and xout 4

Data sheet CPU 115 (115-6BL02)

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

TM221M16R controller M IO relay

FreeSpace E4 Series II System. Presenting a better choice for system designers

D-901 ALL-IN-ONE MODULAR DIGITAL MIXER

TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES AND FUNCTIONS 4. CONNECTIONS 6. APPLICATIONS...

BS 15 BASIC SERIES USER MANUAL FOR THE SINGLE CHANNEL BELTPACK CONTENTS

ASP-MG2240. Amplified Sound Masking System

Switched Mode Power Supply Operating manual PAP800

USB MP3 MIXING AMPLIFIER MA-206U/212U/224U

TM221ME32TK controller M IO transistor PNP Ethernet

Infrared Wireless Conference System

Overview. Features. Technical Data Sheet 1 / 6. Digital Mixing Console TF1

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

ISOMETER isoev425 with coupling device AGH420

Transcription:

Voice Alarm System VX-3000 Series Combined highly integrated voice alarm and public address system

Highly Integrated Voice Alarm & Public Address System The issue of security is more than ever important. Our VX-3000 is a reliable and energy-saving voice alarm system that combines all important functions for PA/VA in one unit frame. The limited number of components makes the design and installation much easier, as well as saving space and reducing cable complexity. This enables rapid system configuration and makes the VX-3000 a cost effective system. It comes with low loss modular class D amplifiers, with 3 different output ratings. These can easily be removed or replaced simply by unplugging them; there is no need for specialist tools. By using low loss modular class D amplifiers and modern power supply switching technology the system becomes much more energy efficient and keeps the operating costs low. Thanks to its flexible and scalable system architecture the VX-3000 system can be used for both small and large applications, with up to 320 remote microphones and 160 audio sources. Light-weight: Modern supply switching technology and digital amplifiers Energy saving: Standby mode for low power consumption during battery backup reduces the required battery capacity Reliable: Advanced failure detection& indication DSP functions: Comp., SPEQ, FBS and Ambient Noise Control (ANC) Integration: Connectable with TOA s other system; NX-300 and IP-3000 Series Remote control: Remote protocol enables VX-3000 to be controlled by external devices. Furthermore VX-3000 complies with Modbus protocol System Component Remote Microphone Amplifier Cost Effective / Space saving All important functions for PA/VE are incorporated in one unit frame. Minimum Components RM-200SF RM-320F RM-300X RM-210F VX-015DA / VX-030DA / VX-050DA Frames Power Supply VX-3008F VX-3000DS / VX-3150DS Decentralized IP Network based, hub-less and the ring topology. Network

Extreme Flexibility Requirements The floor is divided into four zones. Each zone needs individual background music Announcement is sent to selected zone(s) Background music is override by announcement Up to 4 modular amplifiers mountable Multi-route architecture Each zone has an exclusive amplifier One of mounted amplifiers can serve as a standby amplifier The underlying frames of the system are selectable according to the required broadcast pattern. VX-3008F Requirements The floor is composed of multiple zones. Common background music is delivered to all zones Announcement is sent to selected zone(s) without disrupting the background music in the other zones. Background music is override by announcement VX-3008F Up to 3 modular amplifiers mountable, one of which serves as a standby amplifier 2 bus lines and 8 switching zones One amplifier covers multiple zones VX-3008F sb sb * * Requirements The floor is divided into multiple zones with individual attenuator No background music required Announcement is sent to selected zone(s) Up to 2 modular amplifiers mountable 16 switching zones Broadcasting to multiple zones with only one amplifier is possible /sb * * * stands for speaker selector In case of connecting music source, be noted that background music is interrupted by paging announcement. Flexible speaker driving from 1 zone per amplifier up to 64 zones per amplifier 1 zone per amplifier Speaker selector expansion Up to 64 switching zones Scalability One system can be configured with max 40 frames, one of which is set to ID:0 and serves as a master frame. Up to 4 systems can be integrated via VX link, allowing to configure one large scale system with maximum 960 audio inputs and maximum 2,560 zones. System 1 Max 40 frames Max 240 inputs Max 640 outputs etc... System 3 Max 40 frames Max 240 inputs Max 640 outputs etc... 32 32 VX link 32 32 System 2 Max 40 frames Max 240 inputs Max 640 outputs etc... System 4 Max 40 frames Max 240 inputs Max 640 outputs etc...

Frames / VX-3008F / Voice Evacuation Frame front rear VX-3008F rear rear : up to 4 amps (1-zone - 1 amp, 4 AB-zones or 3 AB zones + standby amp) VX-3008F: up to 3 amps (8 zones switching between 2 amps + standby amp or 8 zones freely assignable to 1 of 2 amps) : up to 2 amps (16 switched zones + standby amp or 2 x 8 switched zones) All mandatory indications by EN54-16 Status indication for each speaker line Fault acknowledge and lamp test button Input DSP: 3-point filters(peq/hpf/lpf/high shelving/low shelving), VOX and Comp. Output DSP: 6-point filters(peq/hpf/lpf/high shelving/low shelving/all pass/notch/horn EQ) and Delay Specifications VX-3008F Power Source 20 to 33 V DC, removable terminal block (4 pins) Speaker Line 4 channels (with AB LINE speaker out) 8 channels 16 channels LAN A, B RS Link A, B DS Link Analog Link Control Input Emergency Control IN VOX Function Control Output No. of Connectors: 2 (LAN A, LAN B) ; Network I/F: 100BASE-TX ; Network Protocol: TCP, UDP, ARP, ICMP, RTP, IGMP, FTP, HTTP ; Spanning tree Protocol: RSTP ; Audio Transmission System: TOA Packet Audio ; Audio Encoding Method: PCM ; Audio Sampling Frequency: 48 khz, 16 bits Connection Device: other, VX-3008F,, NX-300 and Switching HUB, Connector: RJ45 connector ; Connection Cable: CAT5 ; Max. Cable Distance: 100 m 2 (RS LINK A, RS LINK B), Up to 8 RM units can be connected to a single VX-3XXXF, up to 4 RM units connectable per RS LINK Connector: RJ45 connector, Connection Cable: CAT5-STP, Max. Cable Distance: 5 m Number of Connectors: 1 input, 1 output, Connection Device: other, VX-3008F,, Connector: R J45 connector, Connection Cable: CAT5-STP, Max. Cable Distance: 800 m 16 inputs, no-voltage make contact input, open voltage: 24 V DC, short-circuit current: 2 ma Fault Detection System: Short circuit, Open circuit, Method: Voltage detect ; Connector: RJ45 connector ; Connection Cable: CAT5-STP Input 2: Isolated voltage input, -24 to +24 V ; Connector: RJ45 connector ; Connection Cable: CAT5 Threshold: 60 to 0 db (1 db steps), Hysteresis: 0 to +10 db, Hold time: 10 ms 10 s, Settable for each audio input General outputs : 8 with CONTROL OUTPUT 1 ; Exclusive outputs : 3 with CONTROL OUTPUT 2 ; GENERAL FAULT, CPU FAULT, CPU OFF No-voltage make contact, electrical contact output, control current: 10 ma, withstand voltage: 28 V DC ; Connector: RJ45 connector ; Connection Cable: CAT5-STP ATT/Control Output 8 outputs, no-voltage make contact, relay contact (NC, NO, C), control current: 2 ma to 5 A ; withstand voltage: 125 V AC, 40 V DV ; Connector: Removable terminal block (12 pins) x 2 16 outputs, no-voltage make contact, relay contact (NC, NO, C), control current: 2 ma to 5 A ; withstand voltage: 125 V AC, 40 V DV ; Connector: Removable terminal block (12 pins) x 4 DSP Audio Input Feedback suppression, Equalizer/Filter, Compressor, Delay and Ambient Noise Control (ANC) 4 inputs (Line: -20 dbv / Mic: -60 dbv / ANC sensor, phantom power selectable) Standby Amplifier Input: 1, Output: 1 ; Max. Voltage/Current: 100 Vrms, 5 Arms ; Connector: Removable terminal block (2 pins) x 2 Extension Amplifier - Input: 2, Output: 2, Max. Voltage/Current: 100 Vrms, 5 Arms, Connector: R emovable terminal block (2 pins) x 4 Input: 1, Output: 1 ; Max. Voltage/Current: 100 Vrms, 5 Arms ; Connector: Removable terminal block (2 pins) x 2 Power Amplifier 4 3 2 Dimensions (W x H x D) 483 x 132.6 x 345 mm (19, 3U) Weight 7.6 kg 7.9 kg 8.1 kg

Amplifiers / EOL Unit VX-015DA / VX-030DA / VX-050DA Digital Power Amplifier Module Low loss modular class D amplifiers Modules to be mounted in the frame units Three different power levels: 150 W, 300 W or 500 W Can easily be removed or replaced simply by unplugging them; no need for special tools Dust filter, easy to clean 100 V Output without transformer resulting in light-weight units Fuse easily accessible from rear Specifications VX-015DA VX-030DA VX-050DA Applicable Model Power Source Amplification System, VX-3008F, 31 V DC (operating range: 20 to 33 V DC) DC power in: M4 screw terminal, distance between barriers: 11mm Class D Power Consumption 1.3W (standby mode), 14 W (no audio input), 40 W (1/8 rated output), 190 W (rated output) at 31 V DC, output voltage selection switch: 100V 1.3W (standby mode), 14 W (no audio input), 65 W (1/8 rated output), 375 W (rated output) at 31 V DC, output voltage selection switch: 100V 1.3W (standby mode), 14 W (no audio input), 100 W (1/8 rated output), 590 W (rated output) at 31 V DC, output voltage selection switch: 100V Rated Output Power Output Voltage 150 W (at 100 V line) 105 W (at 70 V line) 75 W (at 50 V line) (at min. impedance & max. capacitive load) (at AC mains VX-3000DS or VX-3150DS: 187-253 V) 300 W (at 100 V line) 210 W (at 70 V line) 150 W (at 50 V line) (at min. impedance & max. capacitive load) (at AC Mains VX-3000DS or VX-3150DS: 187-253 V) 100 V (70 V, 50 V: selectable) 500 W (at 100 V line) 350 W (at 70 V line) 250 W (at 50 V line) (at min. impedance & max. capacitive load) (at AC Mains VX-3000DS or VX-3150DS: 187-253 V) Min. Resistive Load 67Ω (100 V), 47Ω (70 V), 33Ω (50 V) 33Ω (100 V), 23Ω (70 V ), 17Ω (50 V) 20Ω (100 V), 14 Ω (70 V), 10Ω (50 V) Max. Capacitive Load 0.5 µf Frequency Response Distortion Dimensions (W x H x D) 40 Hz to 20 khz: - 5 to +1 db 1 % or less (at 100 V line, A-weighted) 82.8 x 91 x 358.2 mm Weight 1.3 kg 1.4 kg VM-300SV End of Line Unit Speaker line failure can be detected with high accuracy Module for installation between the speaker line end and the emergency input terminal of the VX-3008F and VX- 3016F.

Power Supply VX-3000DS / VX-3150DS Power Supply Manager DC power supply to all system components Combination of two built-in power source units with a highperformance charger Automatical switch to auxiliary battery power if the AC power supply is down EN 54-4 certified, Certificate No: 1134-CPR-137 Specifications Applicable Model Power Source VX-3000DS System VX-3000 / VX-2000 / SX-2000; all amplifiers 220 230 V AC, 50/60 Hz VX-3150DS Power Consumption DC Power Output (AC mode) 2800 W max in total (at rated output with charging), 650 w max in total, 350 W max each (EN 60065) Rated output: 2300 W (total DC power output), Peak output: 2780 W (total DC power output) 1460W max in total (at rated output with charging) Rated output: 1140 W (total DC power output), Peak output: 1280 W (total DC power output) DC Power Output Charging Method Charging Output Voltage Battery Connection Control Connector DS LINK IN/OUT 8 x 31 V (19 33 V) 25 A max. each, M4 screw terminal, distance between barriers: 11 mm 3 x 31 V (19 33 V) 5 A max. each, removable terminal block (3 x 2 pins) 1 x 24 V (16 25 V) 0.3 A max., removable terminal block (1 x 2 pins) Temperature compensated trickle charging 27.3 V +/- 0.3 V (at 25 C), Temperature correction coefficient: -40 mv/ C One each positive and negative terminal, applicable cable diameter: AWG 6 AWG 0 (AWG 1/0) (16 mm² 50 mm²) Line resistance within 4 mω/ total RJ45 female connector for connecting the system and cascade connection, Shielded Twisted-pair straight cable (TIA/EIA-568A standard) Type of control signal: Battery check, AC power status, DC power status, charging circuit failure, battery failure, and communication Panel Indicator AC power IN 1, IN 2 (Green), Charging (Green), Battery power (Green), Battery connect (Green), Battery condition (Green) AC power IN 1, Charging (Green), Battery power (Green), Battery connect (Green), Battery condition (Green) Dimensions (W x H x D) 482 x 132.6 x 400.5 mm (19, 3U) Weight 11.8 kg 9kg

Emergency Remote Microphone RM-200SF / RM-320F Wall Mount Remote Microphone / Extension Alarm Switch For emergency broadcast For activation of emergency mode, start and stop automatic broadcasts of emergency announcements, reset emergency signals, and live microphone announcements CPU-switch for emergency broadcast to all zones even in case of a CPU error Up to 4 RM-320F Remote Microphone Extension units can be used with each RM-200SF Remote Microphone RM-200SF Microphone Options RM-320F: Key extension unit RM-320F Specifications RM-200SF RM-320F Power Source 24 V DC (operating range: 15 40 V DC) From remote microphone Current Consumption 240 ma or less 180 ma max. Distortion 1 % or less - Frequency Response 200 Hz 15 khz - Signal-to-Noise Ratio 55 db or more - Audio Output 0 dbv, transformer-balanced - Microphone Unidirectional dynamic microphone with talk key, AGC (ON/OFF switchable) - Chime Built inside (PCM sound source), Monitoring available with a built-in speaker Volume Control Microphone volume, Monitor speaker volume, Chime volume (using the software) - Connection Cable Main line: Shielded CPEV cable or Shielded Category 5 twisted pair cable for LAN (CAT5-STP), M3 screw terminal Connection to RM-200SF by dedicated cable No. of Connectable RM -320F Max. 4 units - Key Operation Emergency key, Talk key, 3 Function keys 20 Function keys Finish ABS resin, bluish gray (PANTONE 538 or its equivalent) Dimensions (W x H x D) 200 x 215 x 95 mm 175 x 215 x 70 mm Weight 1.48 kg 700 g

Remote Microphone RM-300X / RM-210F Remote Microphone / Extension For both emergency and general purpose broadcast Zone selection or all call PC-programmable system software permits desired functions to be assigned to individual function keys (equipped with 2 LED indicators) RM-210F: Key extension unit with 10 additional keys Up to 7 RM-210F Remote Microphone Extension units can be used with each RM-300X Remote Microphone RM-300X RM-210F Options AD-246: Power supply unit WB-RM200: Wall-mounting bracket Specifications Power Source RM-300X 24 V DC (operating range: 15-40 V DC), supplied from the audio input unit or DC input power supply connector RM-210F Supplied from the optional RM -300X Current Consumption 240 ma or less 80 ma or less Audio Output 0 dbv, 600 Ω, balanced - External Microphone Input -40 dbv, 2.2 kω, unbalanced, ø3.5 mm phone jack, phantom powering [When used as AUX input] 20 dbv, 4.7 kω, unbalanced - Frequency Response 100 Hz 20 khz - Distortion 1 % or less - Signal-to-noise Ratio 60 db or more - Microphone Unidirectional electret condenser microphone with AGC (ON/OFF selectable) Chime Built inside (PCM sound source), Monitoring available with a built-in speaker Volume Control Microphone volume, Monitor speaker volume, Chime volume (using the software) - Connectable Cable Main line: Shielded CPEV cable or Shielded Category 5 twisted pair cable for LAN (CAT5- STP), Branch line: Shielded Category 5 twisted pair cable (CAT5-STP), RJ45 connector No. of Connectable RM-210F Max. 7 units - Operation Emergency/all-zone emergency broadcast key, Talk key, 13 Function keys 10 Function keys Finish ABS resin, black Dimensions (W x H x D) 190 x 76.5 x 215 mm (gooseneck microphone excluded) 110 x 76.5 x 215 mm Weight 880 g 350 g RM-200RJ Terminal Unit Convert the RJ45 connector into a screw terminal block Used to connect between a trunk cable (such as CPEV cable) and a feeder cable (such as CAT-5 or CAT-6 cable) in wiring a remote microphone Built-in indicator shows the voltage status of DC power cable when the remote microphone cable for the VX-3000 series system is connected Like us on Facebook facebook.com/toaasiapacific TOA Electronics Pte Ltd www.toa.com.sg Specifications are subject to change without notice. Printed in Singapore (65) 865-0918-02