Film capacitors Capacitors for Power Factor Correction

Similar documents
Power Factor Controller BR604

Film capacitors Power Factor Correction

Film capacitors Power Factor Correction

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction

Surge arrester. 2-electrode arrester B88069X2233**** G31-A500X

Film Capacitors Power Factor Correction

Surge arrester. 2-electrode arrester B88069X2613C103 A60-A250XF

Film Capacitors Power Factor Correction

Surge arrester. 2-electrode arrester B88069X2701**** A71-H15X

B88069X2373B152 V14-H14XPD PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

B44066T3050E402 B44066T3850E

PPD AB PD / PPD AB PM

Surge arrester. 2-electrode arrester B88069X2910**** EM550X

Surge arrester. 2-electrode arrester

PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

B88069X4330B152 V10-H30X PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

B88069X3733B252 T21-A90X PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

B3918 B39242B3918U410 May 06,

PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

Magnetics modules for LAN applications

Surge arrester. 2-electrode arrester B88069X1193T303 S20-A470X

Surge arrester. 2-electrode arrester B88069X6071T203 S30-A150X PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

PPD AB PD / PPD AB PM

Evaluation Kit CeraPlas HF

PPD AB PD / PPD AB PM

Surge arresters. 2-electrode arresters

PPD AB PD / PPD AB PM

B725**D****A*** CDS*C**GTA. New important notes template from Mrs. Kopp have been added

Evaluation Kit PowerHap TM

Multilayer Piezo Actuators

Multilayer ceramic capacitors

Film Capacitors Power Factor Correction

SIOV metal oxide varistors

Piezo Haptic Actuator - PowerHap

SIOV metal oxide varistors

SAW components. SAW RF filter Digital radio. February 18, 2016

CTVS Ceramic transient voltage suppressors

Leaded Varistors. AdvanceD-MP series. Date: Version:

Leaded varistors. SuperioR-MP series. Date: Version:

Leaded varistors. AdvanceD-MP series. Date: Version:

Leaded Varistors B72214X2421K501 SIOV- SNF14K420E2S5 PPD VAR PD

Ceramic transient voltage suppressors

PPD VAR PD. Chao Fang, Terry Tian, Mac Gao New issue

SIOV metal oxide varistors

SPECIFICATION FOR APPROVAL

Piezo Haptic Actuators - PowerHap

Power Factor Correction

SIOV metal oxide varistors

SIOV metal oxide varistors

CeraDiodes. Standard series. Series/Type: Date: August 2012

CeraDiodes. High-speed series. Series/Type: Date: July 2014

CeraDiodes. LED series. Series/Type: Date: August 2016

SIOV metal oxide varistors

CeraDiodes. Standard series. Series/Type: Date: April 2016

Power Factor Correction

Multi-Measuring-Interface MMI 6000

CeraDiodes. High-speed series. Series/Type: Date: April 2016

Ceramic transient voltage suppressors

Ceramic transient voltage suppressors

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

Ceramic transient voltage suppressors

Ceramic transient voltage suppressors

Power Factor Correction Power Quality Solutions

CTVS Ceramic transient voltage suppressors

WE-EPLE USB 2.0 A Connector

Power Factor Correction Power Quality Solutions

Ceramic transient voltage suppressors

Operating manual. Diagnostic adapter VAS Operating manual Diagnostic adapter VAS Client documentation Revision: 00 Version: 05/2018

Documentation. Mains filter AX2090-NF50. Version: Date:

Recommended Hole Pattern: [mm] Dimensions: [mm] Schematic: N. Dimensions: A REVISION STATUS DATE (YYYY-MM-DD) BUSINESS UNIT PAGE

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

Ceramic transient voltage suppressors

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

PRO2DM DIN rail single phase two wire energy meter

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

SENTRON ATC Automatic Transfer Control Device

Online data sheet DUSTHUNTER SB100 SCATTERED LIGHT DUST MEASURING DEVICES

Online data sheet. Flow-X FLOW COMPUTER

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

CEM-C6 INSTRUCTION MANUAL (M187B B)

Online data sheet. i200-m0413 Lock i200 Lock SAFETY LOCKING DEVICES

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Online data sheet. i110-e0453 i110 Lock SAFETY LOCKING DEVICES

Transcription:

Multi-measuring interface for BR6000 controller Series/Type: Ordering code: Date: September 2007 Version: 1 Content of inside pages of data sheet. Data will be automatically entered into frontpage headlines, headers and footers. Please fill in the table and then change the colour to White. This ensures that the table disappears for the customer pdf. Identification/Classification 1: (header 1) Identification/Classification 2: (header 2) Ordering code: Series/Type: Film capacitors Capacitors for Power Factor Correction EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited. EPCOS AG is a TDK Group Company.

Characteristics Measuring device for electrical (real current) measurement Additional protection for PFC systems Two in one: Accessory for PF-controller BR6000 series Stand-alone measuring device Illuminated graphical display Small dimensions Technical data and specifications Types/Output -R (1 standard relay) -T (1 optocoupler) Interface RS485 Display Graphical, 2 16 characters Supply and measurement voltage 230 V, 50/60 Hz Power consumption < 4 VA Measurement current X/5 A and X/1 A Output capacity Standard relay: 250 V AC, 1000 W Optocoupler: 60 V DC, 150 ma Measuring temperature range 0 100 C Ambient temperature range 10... +55 C Housing Switchboard installation housing, DIN 43 700 Dimensions 100 100 50 mm Weight 0.5 kg Protection category to DIN 40 050 Front side: IP54 Rear side: IP20 Please read Cautions and warnings and Page 2 of 5

Operation modes Coupling BR6000 Coupling BR6000T DYNA-I-TRIGGER MMI MODBUS RTU MMI ASCII OUT Measurement categories Voltage, current Power factor Active power Reactive power Apparent power Frequency Temperature Energy Languages German and English Ordering Codes -R -T B44066M6000E230 B44066M6100E230 Please read Cautions and warnings and Page 3 of 5

Cautions and warnings General The MMI 6000 may only be used for the purpose it has been designed for. The device has to be projected in such a way that in case of any failure no uncontrolled high current and voltages may occur. The device in operation has to be protected against moisture and dust, sufficient cooling has to be assured. Please note that the device is under high tension during operation. The MMI 6000 may only be used indoor. It is not suitable for outdoor applications. Voltages above the permitted voltage range may damage the device. Attention FAILURE TO FOLLOW CAUTIONS MAY RESULT, WORST CASE, IN PREMATURE FAILURES OR PHYSICAL INJURY. Note For detailed information about PFC capacitors and cautions, refer to the latest version of the EPCOS PFC Product Profile. U Please read cautions information about PFC capacitors and cautions as well as installation and maintenance instructions in the actual version of the Product Profile Power Factor Correction to ensure optimum performance and prevent products from failing, and in worst case, bursting and fire, etc. The actual Product Profile is available at www.epcos.com/publications. Information given in the PFC-product profile and values given in the data sheet reflect typical specifications. You are kindly requested to approve our product specifications or request our approval for your specification before ordering. Please read Cautions and warnings and Page 4 of 5

Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous ). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the General Terms of Delivery for Products and Services in the Electrical Industry published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, MiniBlue, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIOV, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 5 of 5