TECHNICAL PRODUCT DATASHEET

Similar documents
ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) SUITABLE FOR EXTERNAL DISTRIBUTION

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL. Total System Manager

TECHNICAL PRODUCT DATASHEET

TECHNICAL DATASHEET #TDAX Analog Signal Output CAN Controller (SAE J1939)

P/N: AX Distribute your control functions directly onto the valve.

Mounting DIGITAL DISPLAY

In addition to fan control, many other hydraulic control applications can be accommodated with this hardware and application-specific software.

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

SmartFan Cirrus-9. Speed Control and Alarm for 4-Wire Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

PRELIMINARY. Preliminary Technical Datasheet #TDAX Discrete I/O P/N: AX inputs, 8 relay outputs, SAE J1939 with Electronic Assistant

Applications: Stationary, portable power generator sets Genset control systems

PowerView Model PV350 and PV380. Installation Manual Section 78

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

TECHNICAL DATASHEET #TDAX023240

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

P/N: AX Applications: power gen set engine control systems oil and gas equipment automation off-highway machine automation

SmartFan Fusion-4. Speed Control and Alarm for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

TECHNICAL DATASHEET #TDAX I/O

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

Ordering Part Numbers: TECHNICAL DATASHEET #TDAX BLDC MOTOR CONTROLLER P/N: AX100260

SSI-1016H Specifications and Operation Manual

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

Controller Area Networks

JUPITER-MM. DC/DC Power Supply PC/104 Module. User Manual V1.3

HelmView Model HV750; HVS750. Installation Manual Section 78

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO

TECHNICAL DATASHEET #TDAX023300

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

BA/BS4S Temperature Sensor Installation & Operating Instructions

DMX-K-DRV Integrated Step Motor Driver Manual

V-MUX CONNECTOR and ACCESSORY SPEC

Flomatic Smart Card TM Model FDHC-100 (Digital High-Resolution Controller) Configuration and Operation Manual

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

Mounting Card MC1XDZR02-HP1

Technical Datasheet #TDAXTC20 Thermocouple Scanner 20 Thermocouple Channels CAN, SAE J1939 with Electronic Assistant P/N: AXTC20 Description:

MasterFlux 48V Cascade BLDC Motor Controller Product Specification 030F0137

Analog Devices: 6B Series Backplanes : 6B Series : IOS Subsystems : Market Solutions

MC300. BLN Issued: April 2003

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES

HelmView Model HV750. Installation Manual Section 78

Charge Control C Datasheet

CONCEPT P/N: AX Concept TECHNICAL DATASHEET #TDAX Analog Input CAN Controller CAN (SAE J1939 or CANopen ) with Electronic Assistant

Mounting Card MC1XDZR02-QD

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

TECHNICAL DATASHEET #TDAX050000K CAN

Version 1.9. Reference for Part Numbers: EQUBE-P EQUBE-N EQUBE-AI-P

Discrete I/O P/N: AXDIO inputs, 8 relay outputs, SAE J1939 with Electronic Assistant

MD3. Microstepping Motor Driver Page 1 of 7. Description. Software. Mechanical Drawing. Features

Andover ContinuumTM Infinet II

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

Environdata FA ma Converter Guide

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

PHASED OUT PRODUCT DC2. Microcontroller DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: June 1995

DC3IOB Revision User Guide Updated 3/29/10. Overview

FX-2 Control Board ASY-360-XXX Setup and Configuration Guide

Andover ContinuumTM Infinet II

PCIE FIVE SLOT EXPANSION SYSTEM USER S MANUAL

Hardware Manual CNC760

0 5 VDC, 10K Pot or 0 20 ma input, remote mount PCB board, 2000mA max. output

Applications: Industrial Automation, Cranes, Hoists, Utility Vehicles, Off-highway, Ag, and Forestry Equipment

Applications: Power generator sets and control systems for industrial engine applications.

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

UNIVERSAL MOTION INTERFACE (UMI) ACCESSORY

Inclination sensors 2-dimensional, measuring range up to ±90

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ )

ADVANCED MICRO SYSTEMS

E-Learning, DC drives DCS800 Hardware D5 D7, part 2

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

Temperature controller Ducted systems

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

VDC x150A Dual Channel Forward/Reverse Brushed DC Motor Controller

HYDROTHUNDER WIRING & CIRCUIT INFORMATION C H A P T E R F I V E

E-Series General Specifications

BACnet. b3810 Series Local Controllers

LTEC Heat Pump DDC Controller

DirectCommand Installation 5 Channel Spreader Control Module Technology

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

PRODUCT DATASHEET DATE. This report provides appropriate specifications for the FRDS GENII relay enclosure.

Infinity 1U 19 Converter Shelf Models: J L217 - Individual +24V Inputs Bulk -48V Output L218 - Individual -48V Input Bulk+24V Output

HG series Hand grip Hall effect joysticks

Before powering on your driver, read this manual thoroughly. If you have any doubt or suggestion, please do not hesitate to contact us!

Allen-Bradley 1397 L11 I/O Expansion Card

VersaMax IP Input Module

VCM Systems Vehicle Control Module Systems

CompactBlock Guard I/O EtherNet/IP Safety Modules

DAWN Mini ADAQ TC20 Details

Motor Controllers. On-Road AC Motor Controller. Model 1239E.

Measurement Systems Datascan Installation and User Guide

TEMPERATURE CONTROLLER 2 HEAT/ 2 COOL with Digital Room Temperature Display. Made in Australia 100% Australian Owned Company

DVC700 Series Programmable System Controller

NUV300 Datasheet. Nuvation BMS Low-Voltage Battery Controller , Rev Copyright 2018, Nuvation Energy

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

The LSI Gateway. GS220, GS221, GS222 series - LSI gateways. Features:

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

Note: These installation instructions are only for the 4430/4440 Sprayer. For other SPX models please refer to P/N , &

Transcription:

FORM-ENG-0018 REV A 06-02-03 ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR EXTERNAL DISTRIBUTION TECHNICAL PRODUCT DATASHEET ES-Key Climate Control Module P/N 610-00029

1 OF 9 1. REVISION LOG... 1 2. MODULE OVERVIEW... 2 2.1. SCOPE... 2 2.2. HEAT VALVE CONTROL OUTPUT... 2 2.3. AIR CONDITIONING CLUTCH OUTPUT... 2 2.4. FAN MOTOR SPEED OUTPUT... 2 2.5. TEMPERATURE SENSOR INPUTS/OUTPUTS... 2 2.6. MAIN INPUT POWER STUD... 2 3. OPERATION... 3 3.1. AUTOMATIC MODE... 3 3.2. MANUAL MODE... 3 3.3. OPERATION MODE SELECTION... 3 3.3.1. Jumper Selection... 3 3.3.2. Standard Mode... 3 3.3.3. Legacy Mode... 4 3.3.4. Auxiliary I/O operation... 4 4. REPLACING A PN 114942 MODULE IN STANDARD AMBULANCE SYSTEMS... 5 4.1. SYSTEMS USING EITHER PN 115300/115301 OR PN 115491/115727/115492 CONTROL PANELS... 5 5. SYSTEM DIAGRAM... 6 6. CONNECTOR DESCRIPTION... 7 7. DIAGNOSTIC LEDS... 8 8. MOUNTING... 9 9. TECHNICAL DETAILS... 10 1. Revision Log Rev Date Changes 1.00 8-23-2006 Initial requirements 1.10 10-11-2013 Updated datasheet to reflect new hardware with three fan outputs 1.20 04-03-2014 Changed datasheet to reflect part number change from 114942 to 610-00029 for hardware with three fans 1.30 01-05-2015 Added section 4 for legacy replacement setup

2 OF 9 2. Module Overview 2.1. Scope The ES-Key TM Climate Control Module (C1 p/n 610-00029) is an ES-Key node that controls a vehicle s air conditioning clutch, heating valve, and fan motor speed with high current digital outputs based upon received J1939 CAN commands from a supported ES-Key control device. The Climate Control Module has dedicated inputs/outputs for two analog temperature sensors (C1 p/n 108121) to determine internal and external vehicle temperatures. The Climate Control Module has two modes of operation: automatic and manual. 2.2. Heat valve control output Figure 1. Parts identification. The heat valve control output is a high current (25 Amps) positive polarity digital output used to activate the vehicle s heating system when applicable. This output is fully protected against shorts to ground and current overloads. The physical output is a #10 stud configured for ring terminal installation (16ga wire recommended). 2.3. Air conditioning clutch output The air conditioning clutch output is a high current (25 Amps) positive polarity digital output used to activate the vehicle s A/C clutch when applicable. This output is fully protected against shorts to ground and current overloads. The physical output is a #10 stud configured for ring terminal installation (16ga wire recommended). 2.4. Fan motor speed output The 3 fan motor speed outputs are a high current (25 Amps) positive polarity digital Pulse Width Modulated (PWM) output used to drive the vehicle s blower fan at variables speeds. This output is fully protected against shorts to ground and current overloads. The physical output is a #10 stud configured for ring terminal installation (14ga wire recommended). 2.5. Temperature sensor inputs/outputs The Climate Control Module utilizes two Class 1 temperature sensors (C1 p/n 108121) to determine the external and internal vehicle temperatures. The Climate Control Module s embedded firmware adjusts the fan speed and heat/cool operation based on the internal temperature detected while in the automatic mode of operation. The external temperature data is transmitted to supported ES-Key modules for display purposes. 2.6. Main input power stud Main power for the high current outputs is supplied thought this stud (configured for a #10 screw and ring terminal) (8ga wire recommended).

3 OF 9 3. Operation 3.1. Automatic mode The Climate Control Module receives the desired set temperature from a supported ES-Key control module and evaluates against the detected internal temperature. Software algorithms then set the appropriate fan speed PWM output and heat/cool output to maintain the desired temperature. 3.2. Manual mode The Climate Control Module strictly uses the commands from a supported ES-Key control module when setting the heat/cool output and fan speed PWM outputs. In manual mode the Climate Control Module does not attempt to maintain a certain temperature. 3.3. Operation Mode Selection The Climate Control Module can be operated in two modes Standard and Legacy. 3.3.1. Jumper Selection Placing the shunt in position 1 on J2 will select Legacy Mode Placing the shunt in position 2 on J2 will select Standard Mode Placing the shunt in position 1 on J1 will select Legacy address 0x78 Placing the shunt in position 2 on J1 will select Legacy address 0x79 Placing the shunt in position 1 on J3 will select the Aux Output selection Placing the shunt in position 2 on J3 will select the Aux Input selection 3.3.2. Standard Mode Figure 2. Jumper Identification. In Standard Mode the device works like a ES-Key I/O module with an address range of 0x40 to 0x4F by selecting the needed address 0-15 from SW1.

4 OF 9 3.3.3. Legacy Mode Figure 3. Address Switch. In Legacy Mode the device works like a ES-Key I/O module with an address range of 0x78 for address 1 and 0x79 for address 2 (see section 3.3.1). 3.3.4. Auxiliary I/O operation The Climate Control Module pin 10 can be selected for either a positive digital input or a grounded low current output by selecting J3 (see section 3.3.1). If the auxiliary function is selected as an input it will be active when the input voltage is more than 70% of what system voltage is and will turn off when it falls below 70% of system voltage. If the auxiliary function is selected as an output it will turn on from a system CAN message and is rated for.250 amps. (See section 9.1.3 for message information).

5 OF 9 4. Replacing a PN 114942 module in standard ambulance systems 4.1. Systems using either PN 115300/115301 or PN 115491/115727/115492 control panels Jumper J1 Legacy Address - set to position 1 Jumper J2 Operating Mode - set to position 1 The SW1 Address Switch and Jumper J3 do not have to be set for this application.

6 OF 9 5. System diagram Figure 4. System diagram.

7 OF 9 6. Connector Description The Climate Control Module has one connector and the following definitions apply: Mating connector: Deutsch DT06-12SA GRAY Mating sockets: 0462-201-16141 Wedge lock: W12S Recommended wire gage: 16-18 AWG PIN CIRCUIT DESCRIPTION 1 Supply + Module supply (+9VDC +16VDC) [fused 2.5A] 2 CAN High ES-Key CAN, SAE J1939 Proprietary, 250 kbits/s 3 CAN Shield ES-Key CAN, SAE J1939 Proprietary, 250 kbits/s 4 Temp Ref (-) EXT External temperature ground reference 5 Temp Signal EXT External temperature signal input (+174mV +1205mV) 6 Temp Ref (+) EXT External temperature positive reference (+5VDC regulated) 7 Temp Ref (+) INT Internal temperature positive reference (+5VDC regulated) 8 Temp Signal INT Internal temperature signal input (+174mV +1205mV) 9 Temp Ref (-) INT Internal temperature ground reference 10 AUX I/O Aux Input or Aux Output 11 CAN Low ES-Key CAN, SAE J1939 Proprietary, 250 kbits/s 12 Supply - Module supply (vehicle ground) Figure 5. Connector/stud identification.

8 OF 9 7. Diagnostic LEDs The Climate Control Module has seven diagnostic LEDs located beneath the protective metal enclosure. LED COLOR FUNCTION STATUS DRV PWR yellow Shows status of the Main Input Power Stud ON when voltage is present PWR yellow Shows status of the logic supply power (pins 1 & 12) ON when voltage is present VCC red Shows status of internal voltage (after internal fuse) ON when voltage is present ON solid = communicating COMM green Shows the communication status of the module Flashing slow = not communicating Flashing fast = CAN bus error Double flash = CAN bus shorted or Missing terminating resistor NORM MODE green Shows the state of the unit in Normal Operating Mode ON when mode is active LGCY MODE green Shows the state of the unit in Legacy Operating Mode ON when mode is active FAN 1 green Shows the state of the fan motor 1 output ON when output is active FAN 2 Shows the state of the fan motor 2 output ON when output is active FAN 3 Shows the state of the fan motor 2 output ON when output is active AC green Shows the state of the A/C clutch output ON when output is active HEAT green Shows the state of the heat valve output ON when output is active AUX green Shows the state of the AUX output ON when output is active Figure 6. Diagnostic LED identification.

9 OF 9 8. Mounting The Climate Control Module is mounted with four #8 screws. Figure 7. Mounting dimensions inches [millimeters].

10 OF 9 9. Technical details Product category ES-KEY Voltage range +9VDC +16VDC Power consumption Logic supply+ input (pin 1) @13.8VDC 72mA Output power Fan motors 25A Max A/C clutch 15A Max Heat valve 15A Max AUX Output.250 Max Operational temperature range -40ºC +85ºC Environmental range IP 10 CAN specification SAE J1939 proprietary, 250 Kbits/second Internal thermal fuse (750mA on pin 1) Reverse voltage protection (pins 1 and 12) CAN buses protected to 24V Protection ESD voltage protected to SAE J1113 specification for heavy duty trucks (12V) Transient voltage protected to SAE J1113 specification for heavy duty trucks (12V) Load dump voltage protected to SAE J1113 specification for heavy duty trucks (12V) Outputs protected for short circuit and thermal overload Dimensions (W x L x H) in inches [mm] 7.850 [199.39] x 4.250 [107.95] x 2.35 [59.50]