Agilent 70612B K18 Switch Matrix

Similar documents
Agilent OBSAI Protocol Tester

Firmware Guide. Keysight PXIe Chassis Family

87421/22A Power Supply. Operating and Service Manual

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Agilent Protocol Analyzer and Jammer for USB. Quick Start Guide

DDR/LPDDR Custom Configuration Creator Tool. User s Guide

Agilent Gb/s Serial BERT

Agilent Softtouch 2.0 Midbus Probe

Errata. Agilent References in this manual. About this manual. Support for your product

Agilent E4418/19A Power Meter Hardware Upgrade Kit

Getting Started with the Agilent Serial BERT N4906B. You only need a few minutes to get started with the Serial BERT.

Agilent Technologies E5385A 100-Pin Probe

Quick Start/Installation Guide

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

* * Agilent Power Distribution Unit (PDU) Installation Guide

Installation Note. Source Attenuators and Bias Tees Upgrade Kit. For E8362B/C PNA Series Microwave Network Analyzers. Network Analyzer Model Number

Agilent U2941A Parametric Test Fixture

Cary 50. Pre-Installation Manual

Errata. Agilent References in this manual. About this manual. Support for your product

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Agilent E2943A/E2944A ATCA Probes for Advanced Switching Interconnect

Agilent N2739A 1000 Series Oscilloscope Rack Mount Kit

E5504B E18 Phase Noise Measurement System

Agilent N4880A. Reference Clock Multiplier. User s Guide

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Keysight 11636B APC-3.5 mm Power Divider DC to 26.5 GHz

Installation Note. Removable Hard Disk Drive Upgrade Kit. For All PNA Series RF Network Analyzers. Network Analyzer Model Number

Installation Note. Agilent Technologies 85105A Option 50 Installation Instructions for RF Switch Replacement Kit

Agilent M9502A and M9505A AXIe Chassis Firmware Revision. Firmware Update Guide. Agilent Technologies

Installation Note. IF Access Upgrade Kit. For PNA Series Microwave Network Analyzers. Network Analyzer Model Number. Upgrade Kit Part Number

EOS-6000 Series Optical A/B Switch User Manual DC Version

Agilent Technologies 11667A DC to 18 GHz Power Splitter

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

Automated Tuner System Power Distribution Hub

Agilent N4219B Packet Analysis Probe for Serial ATA. User s Guide

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

BIT-3000 Dynamic Sequencing Generator and Analyzer. Datasheet 1.11

Keysight 42941A Impedance Probe Kit

Agilent TS-8989 PXI Functional Test System

Installation Job Aid for Ethernet Routing Switch 3600 Series

RZ5/RZ5D/RZ6 Processor. Operator s Manual

RZ2 BioAmp Processor. Operator s Manual

Agilent G6011A Quiet Cover MS

TRC-190 User s Manual

Installation Job Aid for VSP 4850GTS

HP E2485A. Installation Guide. Memory Expansion Interface. Copyright Hewlett-Packard Company 1997 All Rights Reserved

±15 V Current-Limited Power Supply

Keysight U2722A/U2723A USB Modular Source Measure Units

Agilent 85130C NMD 3.5 mm to Type-N Adapter Kit

Installation Job Aid for VSP 4450GTX-HT- PWR+

Getting Started Guide

Keysight 11878A 50 Ohm 3.5 mm Adapter Kit

TRC-190 User s Manual

Keysight Add Source and Receiver Attenuators Upgrade Kit

SLA Battery Capacity Analyzer

Model Channel TTL I/O

Agilent 34826A BenchLink Data Logger for 34980A. Getting Started Guide. Agilent Technologies

Model 7026 (1x32) 2-wire Multiplexer

Series 8000 RF Signal Switch Solution

Installation Job Aid for Ethernet Routing Switch 5900 Series

CrystalView DVI Multi INSTALLATION AND OPERATIONS MANUAL Stancliff Road Phone: (281)

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Installation and Quick Start Guide

SCXI HIGH-VOLTAGE 8 4 MATRIX TERMINAL BLOCK

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

Line Impedance Stabilization Network (LISN)

Series 8900 LAN. Operation Manual. Part Number (example configuration) Part Number (example configuration)

Keysight Second Source, Combiner, and Mechanical Switches Upgrade Kit

1690-Series Logic Analyzers

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Installation Note. Configurable Test Set Upgrade Kit. For PNA Series RF Network Analyzers (E8801A, E8802A, and E8803A) Network Analyzer Model Number

Manual Version: V1.00. Video Decoder Quick Guide

Agilent TS-5000 Functional Test System

Extended Frequency Range Upgrade Kit (50 GHz to 67 GHz)

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

Keysight 54006A 6 GHz Passive Divider Probe Kit. User s Guide

ABB Drives. User s Manual I/O Module Adapter AIMA-01

Agilent TS-5000 Functional Test System

Series 8000 RF Signal Switch Solution

Agilent CSV Export Utility

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Keysight N7015A/16A Type-C Test Kit. User Guide

Agilent 1260 Infinity Purification Solution

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

1-36V, 0-3A DC Power Supply

Agilent OpenLAB Chromatography Data System (CDS)

Agilent TS-8989 PXI Functional Test System

Agilent TS-5400 High Performance PXI Functional Test System

iconverter 2-Module Power Chassis

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz Product Overview

USER MANUAL. Elo Touch Solutions 2D Barcode Scanner Peripheral

DLS 5405 Operating Manual High Bandwidth Noise Injection Unit

Agilent N5410A Fibre Channel Automated Test Application

Keysight MIPI M-PHY Command Line Packet Generator. User s Guide

Agilent 16442B. User s Guide. Agilent Technologies

User's Guide. Phase Sequence and Motor Rotation Tester Model

Agilent Connector Plate

NX8 Pocket Toner Users Guide

9040/9040UK. Users Manual. Phase Rotation Indicator

Transcription:

Agilent 70612B K18 Switch Matrix Hardware Reference Manual Agilent Technologies

COPYRIGHT 2000 AGILENT TECHNOLOGIES, INC. ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED IN ANY FORM OR BY ANY MEANS (INCLUDING ELECTRONIC STORAGE AND RETRIEVAL OR TRANSLATION INTO A FOREIGN LANGUAGE) WITHOUT PRIOR AGREEMENT AND WRITTEN CONSENT OF AGILENT TECHNOLOGIES, INC., AS GOVERNED BY UNITED STATES AND INTERNATIONAL COPYRIGHT LAWS. PART NUMBER: 70612-92042 PRINTED IN USA NOVEMBER 2000 EDITION 2.0 Notices Warranty The material contained in this document is subject to change without notice. Agilent Technologies makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Assistance Product maintenance agreements and other customer assistance agreements are available for Agilent Technologies products. For assistance, call your nearest Agilent Technologies Sales and Service Office (see Table 2 on page vii). WARNING: A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met. CAUTION: A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. ii Agilent 70612B K18 Hardware Reference Manual

In this manual Chapter 1 General Information Description Specifications Switch Drive Information Chapter 2 Service Service Information Replaceable Parts Information Accessory Information Schematics and Diagrams Agilent 70612B K18 Hardware Reference Manual iii

Safety summary The following general safety precautions must be observed during all phases of operation of this instrument. Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the instrument. Agilent Technologies, Inc. assumes no liability for the customer's failure to comply with these requirements. WARNING: DO NOT REMOVE THE INSTRUMENT COVER Operating personnel must not remove instrument covers. Component replacement and internal adjustments must be made only by qualified service personnel. Instruments that appear damaged or defective should be made inoperative and secured against unintended operation until they can be repaired by qualified service personnel. General This product is a Safety Class 1 instrument (provided with a protective earth terminal). The protective features of this product may be impaired if it is used in a manner not specified in the operation instructions. All light emitting diodes (LEDs) used in this product are Class 1 LEDs as per IEC 60825-1. WARNING: DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE Do not operate the instrument in the presence of flammable gases or flames. Environmental conditions Unless otherwise noted in the specifications, this instrument or system is intended for indoor use in an installation category II, pollution degree 2 environment. It is designed to operate at a maximum relative humidity of 95% and at altitudes of up to 2000 meters. Refer to the specifications tables for the ac mains voltage requirements and ambient operating temperature range. Before applying power Verify that the product is set to match the available line voltage, the correct fuse is installed, and all safety precautions are taken. Note the instrument's external markings described in Safety symbols and instrument markings on page v. iv Agilent 70612B K18 Hardware Reference Manual

Ground the instrument To minimize shock hazard, the instrument chassis and cover must be connected to an electrical protective earth ground. The instrument must be connected to the ac power mains through a grounded power cable, with the ground wire firmly connected to an electrical ground (safety ground) at the power outlet. Any interruption of the protective (grounding) conductor or disconnection of the protective earth terminal will cause a potential shock hazard that could result in personal injury. Fuses Use only fuses with the required rated current, voltage, and specified type (normal blow, time delay). Do not use repaired fuses or short-circuited fuse holders. To do so could cause a shock or fire hazard. Safety symbols and instrument markings Symbols and markings in manuals and on instruments alert you to potential risks, provide information about conditions, and comply with international regulations. Table 1 defines the symbols and markings you may find in a manual or on an instrument. Table 1 Safety symbols and instrument markings Safety symbols Warning: risk of electric shock. Warning: hot surface Caution: refer to accompanying documents. Laser radiation symbol: marked on products that have a laser output. Alternating current. Both direct and alternating current. Three-phase alternating current. Earth (ground) terminal Protective earth (ground) terminal Agilent 70612B K18 Hardware Reference Manual v

Table 1 Safety symbols and instrument markings (continued) Safety symbols Frame or chassis terminal Terminal is at earth potential. Used for measurement and control circuits designed to be operated with one terminal at earth potential. Terminal for neutral conductor on permanently installed equipment. Terminal for line conductor on permanently installed equipment. Instrument markings Standby (supply); units with this symbol are not completely disconnected from ac mains when this switch is off. To completely disconnect the unit from ac mains, either disconnect the power cord, or have a qualified electrician install an external switch. The CE mark is a registered trademark of the European Community. If it is accompanied by a year, it indicates the year the design was proven. The CSA mark is a registered trademark of the Canadian Standards Association. N10149 The C-tick mark is a registered trademark of the Spectrum Management Agency of Australia. This signifies compliance with the Australian EMC Framework regulations under the terms of the Radio Communications Act of 1992. 1SM1-A This text indicates that the instrument is an Industrial Scientific and Medical Group 1 Class A product (CISPER 11, Clause 4). vi Agilent 70612B K18 Hardware Reference Manual

Service and Support Any adjustment, maintenance, or repair of this product must be performed by qualified personnel. Contact your customer engineer through your local Agilent Technologies Service Center. Agilent on the Web You can find information about technical and professional services, product support, and equipment repair and service on the Web: http://www.agilent.com/ contacts/english/noscript.html Double-click the link to Test & Measurement. Select your country from the drop-down menus. The Web page that appears next has contact information specific for your country. Agilent by Phone If you do not have access to the Internet, call one of the numbers in Table 2. Table 2 Agilent Call Centers and Regional Headquarters United States and Canada: Test and Measurement Call Center (800) 452 4844 (toll-free in US) Europe: (41 22) 780 8111 Japan: Measurement Assistance Center (81) 0426 56 7832 Latin America: 305 269 7548 Asia-Pacific: (85 22) 599 7777 Agilent 70612B K18 Hardware Reference Manual vii

viii Agilent 70612B K18 Hardware Reference Manual

Contents 1 General Information Description 1-2 This Manual 1-2 Serialized Test Data 1-2 Year 2000 Compliance 1-2 Specifications 1-3 Table 1-1. 70612B K18 Electrical Specifications 1-3 Table 1-2. 70612B K18 Mechanical and Enviornmental Specifications 1-3 Switch Drive Information 1-4 Table 1-3. 70612B K18 Switch Drive Information 1-4 2 Service Service Information 2-2 Replaceable Parts Information 2-3 Table 2-1. 70612B K18 Replaceable Parts 2-3 Accessory Information 2-5 Table 2-2. 70612B K18 Accessories 2-5 Schematics and Diagrams 2-6 Figure 2-1. 70612B K18 DC Interconnect Assembly 2-7 Figure 2-2. 70612B K18 RF Schematic 2-8 Figure 2-3. 70612B K18 Front Panel Diagram 2-9 Figure 2-4. 70612B K18 Rear Panel Diagram 2-10 Figure 2-5. 70612B K18 Swtich Drive Diagram (board A2) 2-11 Figure 2-6. 70612B K18 Component Layout Diagram 2-13 Agilent 70612B K18 Hardware Reference Manual Contents-1

Contents-2 Agilent 70612B K18 Hardware Reference Manual

1 General Information Description, page 1-2 This Manual, page 1-2 Serialized Test Data, page 1-2 Year 2000 Compliance, page 1-2 Specifications, page 1-3 Switch Drive Information, page 1-4 Agilent 70612B K18 Hardware Reference Manual 1-1

1 General Information Description Description This Manual NOTE: This documentation supports a product that previously shipped under the Hewlett-Packard company brand name. The brand name has now been changed to Agilent Technologies. The two products are functionally identical, only our name has changed. The document still includes references to Hewlett-Packard products, some of which have been transitioned to Agilent Technologies. The Agilent 70612B K18 microwave filter unit Type 2, is a microwave switch matrix which has one input (J1), and one output (J2). The input (1 to 20 GHz) is routed either to the AUX OUT port (J3), a through line (out J2), an internal 50 9load (AT1), or through one of three low frequency RF lowpass flters (F1 through F3), covering 17.6 to 49.8 MHz. An AUX INPUT (J4) can be routed to the output. The K18 has the switching capacity available for adding up to nine more filters. This unit is housed in a 4/8 MMS module, with all connectors on the front. It consists of: Two SP4T switches Four SP6T switches Four 50 9 loads Three filters Switch drive is by means of GPIB commands to the MMS module which drives the internal controller (A1), and driver (A2) boards. A drive table showing how to select switch positions appears later in this manual. For detailed programming instructions, refer to the Agilent 70611/12/13 Operating and Service Manual. Serialized Test Data Serialized test data is provided with each instrument, and is located behind the Serialized Test Data Tab. Year 2000 Compliance This product does no date related processing. Date related standards do not apply to this type of product. 1-2 Agilent 70612B K18 Hardware Reference Manual

General Information 1 Specifications Specifications Table 1-1 70612B K18 Electrical Specifications Frequency range: 1.0 to 20.0 GHz through 17.6, 29.6 49.8 MHz low pass filter paths Insertion loss: VSWR: 5.0 db or less for passbands Flatness less than 1.5 db 1.6:1 or less for passbands Rejection at 1.2 Fc to 2.0 Fc: Power Consumption: -90 db Zero at steady state Table 1-2 70612B K18 Mechanical and Enviornmental Specifications * Altitude: Temperature: Max relative humidity: Height: Width Depth: Weight: Up to 4,572 meters (15,000 feet) 0 C to 55 C (unless otherwise specified) 80% for temperatures up to 31 C, decreasing linearly to 50% relative humidity at 40 o C. 146.3 mm (5.75 in) 190.2 mm (7.5 in) 472.1 mm (18.6 in) 9.98 kg (20 lbs) * For indoor use only (unless otherwise specified). Agilent 70612B K18 Hardware Reference Manual 1-3

1 General Information Switch Drive Information Switch Drive Information Table 1-3 70612B K18 Switch Drive Information 70612B K18 Device Switch Position Switch Driver Board Board Command Channel Function 2 to C A2 Close 100 AUX S1 and S2 Switch 3 to C A2 Close 101 Thru 5 to Cc A2 Close 102 FL1 to FL3, loads 6 to C A2 Close 103 Spares, loads 1 to C A2 Close 104 FL1 (49.8 MHz) S3 and S5 Switch 2 to C A2 Close 105 FL2 (29.6 MHz) 3 to C A2 Close 106 FL3 (17.6 MHz) 4 to C A2 Close 107 NC 5 to C A2 Close 108 NC 6 to C A2 Close 109 50 9 loads 1 to C A2 Close 112 NC 2 to C A2 Close 113 NC S4 and S6 Switch 3 to C A2 Close 114 NC 4 to C A2 Close 115 NC 5 to C A2 Close 116 NC 6 to C A2 Close 117 50 9 loads NOTE: J numbers on driver boards are numerically larger by one than channel numbers. CAUTION: Channels 110, 111, 118 and 119 must not be used (due to drive current limits). 1-4 Agilent 70612B K18 Hardware Reference Manual

2 Service Service Information, page 2-2 Replaceable Parts Information, page 2-3 Accessory Information, page 2-5 Schematics and Diagrams, page 2-6 Agilent 70612B K18 Hardware Reference Manual 2-1

2 Service Service Information Service Information If your instrument requires service, or if you need to remove or replace a component, contact your local Agilent sales and service office. Fasteners in the instrument have both metric and inch threads, with a mix of TORX and pozidrive heads. 2-2 Agilent 70612B K18 Hardware Reference Manual

Service 2 Replaceable Parts Information Replaceable Parts Information Table 2-1 70612B K18 Replaceable Parts Reference Designation Part Number Qty Description A1 70611-60001 1 Controller board A1 U1 70611-80015 1 EPROM A1 U2 70611-80016 1 EPROM A2 87130-62065 1 Driver board A2J1-A2J31 1252-2153 16 Connector, 4-pin, solder to backside of A2 A3 70611-60003 1 Status board AT1-AT4 0960-0053 4 50 ohm termination J1-J4 5062-6618 4 Connector, bulkhead, APC 3.5 (f) / SMA (f) FL1 70612-82062 1 Low-pass filter FL2 70612-82063 1 Low-pass filter FL3 70612-82064 1 Low-pass filter J6 70700-60001 1 Connector, 50-pin / cable to MMA (m/f) S1-S2 87104-60001 2 Switch, 1 x 4, 26.5 GHz, STD S3-S6 87106-60009 4 Switch, 1 x 6, 26.5 GHz, STD W1-W2 70612-22858 1 RF cable, semirigid W3-W4 70612-22859 2 RF cable, semirigid W5 70612-22860 2 RF cable, semirigid W6 70612-22887 1 RF cable, semirigid W7 70612-22888 1 RF cable, semirigid W8 70612-22889 1 RF cable, semirigid W9 70612-22890 1 RF cable, semirigid W10 70612-22883 1 RF cable, semirigid W11 70612-22884 1 RF cable, semirigid W12, W15 70612-22885 2 RF cable, semirigid W13, W14 70612-22886 2 RF cable, semirigid W16 70611-60006 1 Cable, A1 to A3 W17 70612-60002 1 Cable, A1 to A2 0510-1244 1 Clip 0900-0012 1 O-ring 1460-2095 4 Spring Agilent 70612B K18 Hardware Reference Manual 2-3

2 Service Replaceable Parts Information Table 2-1 70612B K18 Replaceable Parts (continued) Reference Designation Part Number Qty Description 5001-5835 2 Bar connector 5001-5840 1 Ground clip 5022-0051 1 Latch screw 70594-00003 1 Panel rear 70611-22401 1 Front frame 70611-22402 1 Base 70611-22403 1 Rear frame 70612-00020 2 Bracket, left 70612-00021 2 Bracket, right 70612-02027 1 Cover 70612-02220 1 Deck 70612-02222 1 Filter bracket, right 70700-0004 1 Ferrite bracket 70700-40002 2 PC board guide 2-4 Agilent 70612B K18 Hardware Reference Manual

Service 2 Accessory Information Accessory Information Table 2-2 70612B K18 Accessories Description Part Number 70612 B K18 Hardware Reference Manual 70612-92042 70612B K18 Hardware Reference CD-ROM 70612-90033 70611/12/13 Operating and Service Manual 70611-90015 Agilent 70612B K18 Hardware Reference Manual 2-5

2 Service Schematics and Diagrams Schematics and Diagrams 70612B K18 DC Interconnect Assembly 70612B K18 RF Schematic 70612B K18 Front Panel Diagram 70612B K18 Rear Panel Diagram 70612B K18 Swtich Drive Diagram (board A2) 70612B K18 Component Layout Diagram 2-6 Agilent 70612B K18 Hardware Reference Manual

Service 2 Schematics and Diagrams 70612b_k18_dcs.cdr 2/10/97 rev 1.0 Figure 2-1 70612B K18 DC Interconnect Assembly Agilent 70612B K18 Hardware Reference Manual 2-7

2 Service Schematics and Diagrams 70612b_k18_rfs.cdr 2/10/97 rev 1.0 Figure 2-2 70612B K18 RF Schematic 2-8 Agilent 70612B K18 Hardware Reference Manual

Service 2 Schematics and Diagrams 70612b_k18_front.cdr 12/10/96 rev 2.0 Figure 2-3 70612B K18 Front Panel Diagram Agilent 70612B K18 Hardware Reference Manual 2-9

2 Service Schematics and Diagrams 70612b_k18_rear.cdr 2/10/97 rev 1.0 Figure 2-4 70612B K18 Rear Panel Diagram 2-10 Agilent 70612B K18 Hardware Reference Manual

Service 2 Schematics and Diagrams 70612b_k18_sds.cdr 4/2/97 rev 1.0 Figure 2-5 70612B K18 Swtich Drive Diagram (board A2) Agilent 70612B K18 Hardware Reference Manual 2-11

2 Service Schematics and Diagrams 2-12 Agilent 70612B K18 Hardware Reference Manual

Service 2 Schematics and Diagrams 70612b_k18 1/8/97 rev 1.0 Figure 2-6 70612B K18 Component Layout Diagram 70612B K18 Hardware Reference Manual 2-13