Heating Circuit Controller

Similar documents
Heating Circuit Controller

ERF910. RF Repeater. Synco living

RF adapter plugs, dimming

Room Temperature Controller

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Room Temperature Controller

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Room Temperature Controllers

Semi flush-mounted room temperature controllers with LCD

Power supply module, bus connection module

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Semi flush-mounted room temperature controllers with LCD

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

Resistance measuring module

RXB39.1. Room controller RXB. Communicating room controller for fan-coil applications FC-13

Immersion Temperature Sensors

Temperature Controller

Non-communicating room controllers

Semi Flush-mount Room Temperature Controllers with LCD

7-day room temperature controller

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Electrical Actuators

Web interface BACnet/IP

Extension module for lighting control

Room unit with PPS2 interface

Temperature controller Ducted systems

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

Electromotoric actuators

Electromotoric actuators

7-day room temperature controller

Switching and Monitoring Device

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Island bus expansion module

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Weekday / weekend room temperature controller

SEH62.1. Digital Time Switch

RDF301 RDF CE1N3171en 02 Jun 2010 Building Technologies

Master room unit for RRV controllers

Electrical actuators

Radiator Valves. Building Technologies HVAC Products. NF norm, for 2-pipe heating systems

TXM1.8RB. TX-I/O Blinds module

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

Electrical Actuators

Heating Controllers. Siemens Building Technologies HVAC Products. Synco 700

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Electrical Actuators

Extension module Integration of existing PTM I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

Universal Controller

Room unit with PPS2 interface

Electromotoric actuators

Communication module to connect M-bus devices to POL6xx.xxx controllers.

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

M-Bus Central Unit. Use

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

OP10. Pre-programmed, configurable controller for simple applications

Room unit with PPS2 interface

Room unit with PPS2 interface

Non-communicating room controllers

Room thermostat with KNX communications For VAV heating and cooling systems

Electromotive actuators for combi valves

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Status display unit with P-bus connection

Electromotoric actuator

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

Compact Universal Controllers

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Central control unit

Electromotoric actuators

Rotary actuators for ball valves

Fast running actuators for air dampers

Rotary version, three-position control

Temperature Controller (Heat Pumps)

EYE 200: DDC single-room controller, ecos200

Weekday / weekend room temperature controller

24-hour room temperature controller

Air damper actuators

RMZ790. Operator Unit. Building Technologies. Synco 700

Mobile Data Collector

Digital input modules

BACnet/IP Web Interface

Compact universal controllers

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

AEW Pulse Adapter. Building Technologies

VAV modular controller

Airflow Pressure Sensor

VAV compact controller KNX / PL-Link

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RXL21.1 RXL22.1. Room controllers RXL. Communicating controllers for fan-coil applications FC-10, FC-11, FC12

Room thermostats with KNX communications

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

Super universal modules

Compact room automation stations, BACnet/IP, AC 230 V

Transcription:

2 706 Synco living Heating Circuit Controller RRV918 RF-controlled heating circuit controller for up to 8 heating circuits RF communication based on KNX standard (868 MHz, bidirectional) Connection facility for up to eight 2-position actuators Mains-powered AC 230 V 1 universal relay output 1 universal input Use For integration into the Siemens Synco living system Suited for use in heating plant With central heat distributors (e.g. underfloor heating or soft steel piping system) For use with motorized radiator valves (e.g. with sill covers) Heating circuit control with 2-position actuators Universal relay output, e.g. for control of the apartment pump, DHW heating, or fan speeds Universal input, e.g. for connection of a DHW temperature sensor or an alarm CE1N2706en 07.01.2009 Building Technologies

s s Equipment combinations The RRV918 heating circuit controller is designed for use with the Siemens Synco living system. For more detailed information about equipment combinations, refer to the Data Sheet covering the central apartment unit (CE1N2707en). The RRV918 can be used in connection with the following types of actuators from Siemens, depending on the application: Heat distributor with individual room control RRV918 270 6Z0 1de 2706S01 Type of actuator STA21 STP21 Thermal Thermal Data Sheet no. N4877 N4878 Normal state NC NO Type of valve Depending on the type of heat distributor, connection M30 x 1.5 mm Radiators RRV918 270 6Z0 1de 2706S02 1 2 8 Type of actuator STA21 STP21 Thermal Thermal Data Sheet no. N4877 N4878 Normal state NC NO Type of valve VDN, VEN, VUN, VPD, VPE Also refer to Data Sheet CE1N2100en: Small valves, actuators and accessories. 2 / 10

Ordering When ordering, please give quantity, product name and type reference. Scope of delivery The RRV918 is supplied complete with Mounting Instructions. Product documentation The Operating and Commissioning Instructions for the RRV918 are contained in the product documentation of the central apartment unit. Functions Main function Universal relay output Universal input Parallel operation In operation, the RRV918 maintains the required room temperature of the individual heating circuits. The central apartment unit delivers the relevant data via RF. The universal relay output can be used to control different types of devices. Release is controlled via the central apartment unit and delivered via RF. 1 The universal input is used for connection of the DHW temperature sensor, for example. The data are forwarded to the central apartment unit via RF. 1 Several heating circuits can be assigned to one room and, therefore, operated in parallel. In that case, the first heating circuit ensures the actual room control and, at the same time, controls the other assigned heating circuits. Antilime function Summer operation Window airing The antilime function is triggered by the central apartment unit. When receiving an antilime command, the heating circuit valve will be fully opened and then closed again. When the antilime function is completed, the valve will return to the previous control position. Summer operation is triggered by the central apartment unit. When receiving a command to start summer operation, the heating circuit valve will be opened or closed, depending on the position predefined by the central apartment unit. If the antilime function is activated in summer operation, it will be performed. When completed, the control loops will resume summer operation. The window airing function is triggered by the central apartment unit. The function interferes in the control process in a way that overheating of the room will be avoided both during and after the window airing time. Frost protection for the room Frost protection for the room becomes active if the room temperature drops below the frost protection setpoint. It remains active until the room temperature returns to a level 1 K above the frost protection setpoint. Binding The binding of the first selected channel is used by the RRV918 to sign on at the central apartment unit, thus ensuring integration into the RF system. Then, the other channels can be assigned to other rooms or function groups. The binding process is triggered via the multifunction button and indicated by the multifunction LED. 1 For detailed information about assignment options for the inputs and outputs, refer to the Synco living Mounting and Commissioning Instructions (CE1C2707en). 3 / 10

Status query RF binding test Resetting a channel Supply state RF failure Mains failure Error messages The multifunction button can be used to query the state of the configured control channels. The state is indicated by the multifunction LED. The multifunction button can be used to trigger a binding test per channel. The test is made to check the radio link to the central apartment unit. The RF binding test is indicated by the multifunction LED. The multifunction button can be used to reset a configured channel to its supply state. Then, the channel must be reconfigured in the system. The state is indicated by the multifunction LED. The multifunction button can be used to reset the RRV918 to its supply state. Then, the RRV918 must be reintegrated into the system. If radio transmission between the RRV918 and the central apartment unit breaks down, control is no longer ensured. The heating circuit valves will open. When radio transmission is reestablished, the RRV918 will return to control mode. In the event power supply to the RRV918 is interrupted, control is no longer ensured. The positions of the individual actuators can only be changed manually on the actuators themselves. When mains supply is restored, the RRV918 will return to control mode. The following error messages are delivered by the RRV918: Error messages Communication error (no communication for one hour) 4 / 10

Operating and indicating elements Multifunction LED Channel LED Mains LED s 644474448 Nc No B Q1 1 2 3 4 5 6 7 8 CH RRV918 2706Z01de Multifunction button Actuator selector Channel selection button Slot for opening the terminal cover Function of operating elements Operating elements Multifunction button Actuator selector Channel selection button Function State query of channel configuration RF binding test Binding Disconnection of channels from the system Restoration of supply state Selection of the type of actuator Channel selection Function of indicating elements Indicating element Multifunction LED Channel LEDs: B Q1 Y1 Y8 Mains LED Function Indication of channel configuration RF binding test Binding process Disconnection of channel from the system Indication of channel configuration / status indication: Universal input Universal relay output Controller outputs Power supply For more detailed information about the functions and operation of the RRV918, refer to the product documentation covering the central apartment unit. 5 / 10

Notes on engineering and operation Mounting location Due to its compact design, the RRV918 can be fitted directly in the heat distribution panel*, on the ceiling in the cellar, or in the cable riser The permissible environmental conditions must be observed The RRV918 must not be exposed to dripping water For notes relating to engineering and mounting RF devices of the Siemens Synco living system, refer to Data Sheet CE1N2708en When mounting the RRV918, ensure that there is sufficient space by the connection terminals to introduce the cable ( 30 mm) At the top of the unit, a minimum clearance of 50 mm must be observed 30 mm to ensure that the operating elements can be accessed and that the terminal cover can be easily opened. 2705Z02de 50 mm * Plastic covers are used in place of metal covers to support radio communication. Installation The RRV918 is designed for: Mounting on top hat rails conforming to EN 60715-TH35-7,5 Fitting with the help of 2 fixing screws Note Prior to applying power, connect all heating circuits and the inputs and outputs. Commissioning Maintenance Disposal Prior to commissioning, check to ensure that the RRV918 is correctly mounted, that all wiring is correctly made, and that power is switched on. The RRV918 is maintenance-free. In terms of disposal regulations, the RRV918 is classified as electronic scrap conforming to the European Directive 2002/96/EG (WEEE) and must not be disposed of as domestic waste. Local and currently valid legislation must be observed. Warranty Application-related technical data are only warranted in connection with the Siemens Synco living system. For equipment combinations, refer to the Data Sheet of the central apartment unit (CE1N2707en). When using the RRV918 together with third-party devices, correct functioning must be ensured by the user. In that case, Siemens will assume no responsibility for service and warranty. 6 / 10

Technical data Power supply Operating voltage AC 230V (± 10%) Frequency 50 Hz Power consumption (with no external load) max. 7 VA Fusing of supply line 10 A RF Frequency Range Protocol 868 MHz (bidirectional) typically 30 m inside buildings KNX RF-compatible Universal input Permissible cable length to sensor or external contact Universal relay output Controller output Electrical connections Type LG-Ni 1000 resistor (on / off) Quantity 1 Measuring range 0 120 C Copper cable 0.6 mm dia. max. 20 m Copper cable 1 mm 2 max. 80 m Copper cable 1.5 mm 2 max. 120 m Type NO contact AC 24 230 V, AC 0.02 2 (2) A Quantity 1 Type Triac AC 230 V, AC 5 30 ma Switch-on current max. 60 ma 2 s max. 250 ma 0.5 s Number of outputs 8 Number of actuators max. 2 per output and max. 10 per RRV918 Permissible cable length max. 10 m Screw terminals for max. 2.5 mm 2 Type of controller 2-position PID Standards Protection Environmental compatibility conformity to EMC directive - Immunity, Emissions Low-voltage directive - Electrical safety RTTE (Radio & Telecom. Equipment) - Wireless communication Safety class II to EN 60730 Housing IP 30 to EN 60529 Degree of pollution 2 to EN 60730 Environmental product declaration CE1E2706en provides information on environmentally compatible product design and assessment (RoHS compliance, composition of substances, packaging, environmental benefit and disposal) 2004/108/EC - EN 60730-1, EN 60730-2-9 2006/95/EC - EN 60730-1, EN 60730-2-9 1999/5/EC - EN 300220-2, EN 301489-1, EN 301489-3 ISO 14001 (Environment) ISO 9001 (Quality) SN 36350 (Environmentally compatible products) 2002/95/EC (RoHS) Dimensions Weight Housing material Housing color Unit complete with accessories Upper / lower housing section refer to Dimensions 0.553 kg plastic PC+ABS RAL 7035 light-gray RAL 5014 dove-blue 7 / 10

Environmental conditions operation transport storage EN 60721-3-3 EN 60721-3-2 EN 60721-3-1 Climatic conditions class 3K5 class 2K3 class 1K3 Temperature 0 +50 C -25 +70 C -20 +65 C Humidity 5 95 % r.h. <95 % r.h. 5 95 % r.h. (noncondens-ing) Mechanical conditions class 3M2 class 2M2 lcass 1M2 Elevation above sea level min. 700 hpa, corresponding to max. 3000 m above sea level Connection terminals Legend L Operating voltage, live wire AC 230 V N Operating voltage, neutral conductor AC 230 V B Universal input M Ground for universal input Q13, Q14 Universal relay output for AC24 230 V Y1 Y8 Outputs controllers 1 8, AC 230V N Neutral conductor for controller output Note: With controller outputs Y1 Y8, the live wire (L) is switched. The neutral conductor is internally connected. The relay output is potential-free. Connection diagram 2-position control Legend N1 Heating circuit controller RRV918 Y1 Y8 Actuators (thermal valve actuators) 1) Universal input, can be used for temperature acquisition / digital input 2) Universal potential-free relay output, can be used for mains or low-voltage 8 / 10

Dimensions Dimensions in mm 245 50 1 49 1,5 27,4 35,3 8 27,4 3 8,5 20,2 ø 5 98 90 7,2 230,5 2706M01 9 / 10

10 / 10 2006-2009 Siemens Switzerland Ltd Subject to change