Version 5 Controls for natural ventilation. WUF 110 / 121 / 150 Actuator interfaces

Similar documents
Version 4 Controls for natural ventilation. WCC 310 / 320 PLUS MotorController

Version 10 Actuators. WMU 836 Chain actuator 300N

Version E. Actuators. WMX 526 / 526 UL / 826 / 826 UL Chain actuator

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

WMU 842 / 861 / 862 / 863 / 864 / 882 / 883 / 884 / 885 / 895

WSK Thermokon / / / Battery free wireless keypad and remote control

MobileView Junction Box

SPECIFICATION. SFX Form Factor. SST-ST45SF 450W Switching Power Supply Active PFC Circuit Full Range Input. SFX Form Factor

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

DOR6. Components All functions and indications are on the front of the module. Characteristics

GT-A81051-XXYY SERIES 5W

Nokeval. FD100 series. User Manual

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

120 WATT FLEX ATX TYPE WITH ACTIVE PFC

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

60 Watt Medical (MWLT)

Installation Manual for D244X Series 24-volt Power Supplies

Enhancing Business Performance

GLX40 GLX50 UL EN GLX60 GLX110-B GLX110-C GLX200 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX250-CEF GLX250-CF

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

VP ELECTRONIQUE MASSY - Tel

Power Supplies GLX40 GLX50 GLX60 GLX110-B GLX110-C GLX120 GLX140-C GLX140-CF GLX150-C GLX17Q-C GLX17S-C GLX200 GLX250-CEF GLX250-CF

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Room Temperature Controller

Blue ID Power injection module PI60

Electrical Specifications. Input Current 115 VAC: 1 A max. 230 VAC: 0.5 A max.

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

E-STOP relays, safety gate monitors

Process displays For current and voltage

E-STOP relays, safety gate monitors

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

PRODUCT SPECIFICATION

CVN300-96P01A SERIES. Five Output. Special Features

RТTH DUAL ROOM SWITCH

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

Single-Core PVC 6491X

Table of Contents. 1 General 1.1 Scope

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green

E-STOP relays, safety gate monitors

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

SUBJECT TO CHANGE WITHOUT NOTICE

EM2020 Selectable AC transducer A (UK)

E-STOP relays, safety gate monitors

LFWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

Universal Controller

Electrical Actuators

Compact Coded Magnetic Safety Interlock Switch and Control Units

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

Chrome DIN Rail Power Supply 24V 60W 1 Phase (Class II & NEC Class 2) / DRC-24V60W1A

TA-Slider 160. Actuators Digitally configurable proportional push actuator 160/200 N

E-STOP relays, safety gate monitors

Magnetically Actuated Safety Interlock Switches

Electrical Actuators

LFMWLP225 SERIES 225 Watt Open Frame Power Supply Measures: 4.00 x 2.00 x 1.00

CM Series. Most Diverse and Flexible Line of Coded Magnetic Safety Interlock Switches and Controllers. Description. Safety Interlock Switches

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

Power Supplies V7-T6-2 V7-T6-4 V7-T6-10 V7-T6-16 V7-T6-36 V7-T6-39 V7-T6-43

AC5160 SiPass integrated controller kit

CANBUS Connector Rx and Tx LED to indicate that communication is active Closed circuit terminal (Term) LAN serial port connector

F3S-B. Safety Design for Category 2. Suitable for Detecting Human Bodies in a Dangerous Area. Safety Light Curtain. Features

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

Technical specifications

Gas Discharge Tube. Indicator Light(2) UL Parallel 1600 V N N / PU-20KS10KTTN. UL Series 1600 V N N 15 A PU-20KD10KTTN

Immersion Temperature Sensors

Electromotoric actuators

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Room Temperature Controller

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

Input Voltage Range AC Input. Input Frequency Range. Output Power natural convection. Operating Temperature Range. Model Selection

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

Product data sheet AIRWIN Power supply Accessories AIRWIN

Decentralised operating and monitoring systems

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

PSU User s manual Rev. 0 January

Thread length (overall length) material

System Specifications

Contact form. Operating Force. SPDT 100g Unsealed Solder / 187 Quick Connect. SPDT 200g Unsealed Solder / 187 Quick Connect

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

IST ULTRASTAB Power Supply for high precision transducers

Power Supply HARTING pcon

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

E-STOP relays, safety gate monitors

PMT. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMT-5V350W1A (Selectable by Switch)

LED Driver Linear / area fixed output

Safety Systems Safety Integrated

PMT. Safety Standards. Model Number:

LED Driver DC-String

System Specifications

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Electronic monitoring relays PMDsrange

Transcription:

Version 5 Controls for natural ventilation WUF 110 / 121 / 150 Actuator interfaces 6.05 WUF 121 WUF 110 WUF 150 Application the motor interface is used for individual operation of a ±24V DC actuator from a 230V AC control system the interface has one phase for opening the and one phase for closing the to be used with one or more Windowaster ±24V DC actuators with a total power consumption of 1A, 3A or 5A as well as a keypad e.g. WSK 100 there are three variants of the actuator interface: WUF 110: max. 1A WUF 121: max. 3A WUF 150: max. 5A WUF 110 Interface for actuators with a total power consumption of max 1A. See table for further information on actuator type and numbers. WUF 150 Interface for actuators with a total power consumption of max 5A. See table for further information on actuator type and numbers. Up to eight interfaces can be connected in parallel to the same switch. Notice the peak current and on side fuse characteristic. The interface can be installed on the wall or on the ceiling next to the actuators. No special tools are required. 230 Volt and actuator connections are done via screw terminals. The interface are not supplied with cables. The interface can be installed in the profile next to the Windowaster actuator or fitted on the frame. The connection to the actuator is made via a 2-pin connector. The 2m 3-core cable is connected to the 230V main supply via the switch. WUF 120 Interface for actuators with a total power consumption of max 3A. See table for further information on actuator type and numbers. The interface can be installed on the wall. No special tools are required. The 1.3m 3-core cable is connected to the 230V main supply via the switch.

WUF 110 Technical specifications ax power consumption 1A - see table below for possible actuator types and numbers Primary voltage 230V AC, ±10%, 50/60Hz, 50VA Secondary voltage 24V DC, max. 0,8A Inrush current on primary side ax. 10A < 1msec. Standby consumption ax. 2W by 230V (no actuators runs) Open circuit voltage 24V ± 1V by 230V Ripple by full load < 1% (0.3Vpp) Insulation/Earthing ax. switching capacity between both phases Constant power Operating conditions The interface is a double insulated class 2 product, which means it will not require earth connection ax. 1µF Yes -5 C - +45 C, max. 85% relative humidity, for indoor installation, the interface may not be covered Switch on duration ED max. 40% (max. 2min. per 5min.) aterial Plastic cabinet Colour Grey (RAL 7004) Size 160 x 29 x 42mm (W x H x D) Weight 350g IP rating IP44 Delivery includes Interface with 2m net cable and 0.1m cable with nylon connector on the secondary side (24V) Note We reserve the right to make technical changes Windowaster actuator type ax. number of actuators, connected to the WUF 110 Secondary voltage (max. 27 V) WL 825* 1 WX 503-1/504-1/523-1/526-1* WX 503-2/504-2/523-2/526-2* WX 803-1/804-1/823-1/826-1* 1 *Aside from a actuator(s) it is also possible to connect a locking/espagnolette actuator (single) type WB 801 or WB 811. 2

WUF 121 Technical specifications ax power consumption 3A - see table below for possible actuator types and numbers Primary voltage 230V AC, ±10% Secondary voltage Nominal Low High ±24V DC, 3A 17-27V DC. 20-30V DC (standard) Inrush current on primary side ax. 10A<10msec Standby consumption 3W by 230V (no actuators runs) Open circuit 30V by 253 Ripple at full load 10% (2Vpp) Insulation/Earthing The interface is a double insulated class II product, which means it will not require earth connection Constant power Yes Operating condition -5 C - +45 C for indoor installation, the interface may not be covered Switch on duration ED max 40% (max. 2min. per 5min.) aterial Housing in shockproof fire retardant polycarbonate in accordance with UL 94-5V Colour White (NCS 1000) Size 180 x 110 x 70mm (W x H x D) Weight 1.4kg IP rating IP20 Delivery includes Note Actuator interface with 1.3m mains cable (without a cable for connection to the actuators, connection on the terminal block) We reserve the right to make technical changes ax. number of actuators, connected to the WUF 121 Windowaster actuator type Secondary voltage high (standard) (max. 30V) Secondary voltage low (max. 27V) WL 825 3 * WS 306-1/306-2 2 * WS 309-1/309-2 2 * WS 409-1 1 * WU 836-1/836-2 ** 3 * WU 842-1 ** 1 * WU 861-1 ** 3 * WU 861-2 ** 2 * WU 862-1/863-1 ** 1 * WU 882-1/883-1 ** 1 * WX 503-1/504-1/523-1/526-1 ** WX 503-2/504-2/523-2/526-2 ** WX 503-3/504-3/523-3/526-3 ** 6 * WX 503-4/504-4/523-4/526-4 ** 4 WX 803-1/804-1/823-1/826-1 ** 3 * WX 803-2/804-2/823-2/826-2 ** 2 * WX 803-3/804-3/823-3/826-3 ** 3 * * The actuator is not suitable for this voltage. ** Aside from a actuator(s) it is also possible to connect locking/espagnolette actuator(s) type WB 801 or WB 811 / WB 812.

WUF 150 Technical specifications ax power consumption Primary voltage Secondary voltage Inrush current on primary side Fuse on site Standby consumption 5A - see table below for possible actuator types and numbers 230V AC, ±10%, 50-60HZ, 120VA ±24V DC ±2%, 5A ax. 10A<10msec Up to eight interfaces in parallel under one 10A automatic fuse with C, D or K characteristic 3W by 230V (no actuators runs) Open circuit 24V by 253 Ripple at full load ax. 2% Connection Primary site: 2,5mm 2 Secondary site: 4mm 2 Insulation/Earthing Constant power Operating condition Switch on duration aterial Class I product accordingly EN 60 850-1, why earth connection is required Yes -5 C - +50 C max. 90% RH, for indoor installation, the interface may not be covered or exposed directly to the sun ED max 40% (max. 4min. per 10min.) ABS Colour White (RAL 9010) Size 208 x 172 x 81mm (W x H x D) Weight IP rating Delivery includes Note 1.4kg IP30 Interface with screw terminals for 230 Volt and actuators connections. The interface units are supplied without cables. We reserve the right to make technical changes

WUF 150 continued Windowaster actuator type ax. number of actuators, connected to the WUF 150 WL 825 1) 5 WS 306 1) 4 WS 309 1) 4 WS 409 1 ) 2 WS 306-1 / -2 2) 4 WS 309-1 / -2 2) 4 WS 409-1 / -2 2) 2 WU 836-1 / -2 2) 4 WU 842-1 / -2 2) 4 WU 861-1 2) 5 WU 861-2 2) 4 WU 862-1 2) 2 WU 863-1 2) 1 WU 864-1 3) 1 WU 882-1 2) 2 WU 883-1 2 ) 1 WU 884-1 3 ) 1 WU 885-1 3) 1 WU 895-1 3) 1 WX 503 / 504 / 523 / 526-1 / -2 2) 10 WX 503 / 504 / 523 / 526-3 2) 9 WX 503 / 504 / 523 / 526-4 2) 8 WX 803 / 804 / 823 / 826-1 2) 5 WX 803 / 804 / 823 / 826-2 2) 4 WX 803 / 804 / 823 / 826-3 2) 3 1) Aside from a actuator(s) it is also possible to connect a locking/espagnolette actuator(s) type WB 801. 2) Aside from a actuator(s) it is also possible to connect a locking/espagnolette actuator(s) type WB 801 or WB 811 / WB 812. 3) Aside from a actuator it is also possible to connect locking/espagnolette actuator(s) type WB 811 / WB 812.

Connection 230V AC L N L: black L: brown N: blue WUF 110 mounted on one or more s 230V AC L N L: black L: brown N: blue WUF 121 The actuator is mounted on one max. 50m 230V AC PE WUF 150 N L Fuse on site not Up to eight interfaces can be connected in parallel to the same switch. Notice the peak current and on-site fuse characteristic. WUF 150 max. 50m Example 1: WUF 150 Example 2: max. 50m Notice: When more actuators are, all the actuators must be of the same variant meaning that all are to be either double, triple or quad.

WUF 110 / 121 / 150 Actuator interfaces Items Item no. Actuator interface 230 VAC / 24 VDC, 1A WUF 110 Actuator interface 230 VAC / 24 VDC, 3A WUF 121 Actuator interface 230 VAC / 24 VDC, 5A WUF 150 Size WUF 110 WUF 121 WUF 150 180 208 29 42 160 110 172 70 81 UK +44 (0) 1536 510990 info@master.co.uk Other markets +45 4567 0300 info@master.com Windowaster 2002/2005/2014, 2015 Windowaster is a registered trademark used under license by Windowaster Group master.com