TABLE OF CONTENTS TECHNICAL SPECIFICATIONS... Page 9

Similar documents
Enhanced Mini-Chansim Model VCS-232

1206P (CTS ME-X.21) MODEM ELIMINATOR, X.21 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1206P-A

1205P MODEM ELIMINATOR, V.35 INSTALLATION AND OPERATIONS MANUAL. Doc #: UA Part #: 07M1205P-A (CTS ME-V.35)

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

USER MANUAL. MODEL 2011 High Speed Asynchronous to Synchronous Converter

ME930C-RJ11 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-11 INTERFACE MODULE (REAR CARD) Serial: DB25 CONN. SW1 RJ-11 CONN.

USER MANUAL. MODEL 1052 idsl Modem with RS-232 Interface. An ISO-9001 Certified Company SALES OFFICE (301) TECHNICAL SUPPORT (301)

F2238A and F2245A Fiber-Optic EIA-530/MIL-STD Modem Technical Manual

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

OPERATIONS MANUAL. Sync2IP 2-Port Sync or Async to LAN Adapter

Enclosure TS-530 User Manual

F280XD Fiber-Optic RS-232 Modem Technical Manual

ME758C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: DB25 RJ45 CONN. INTERFACE MODULE (REAR CARD)

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

D56 Modem TABLE OF CONTENTS SECTION 1 - DESCRIPTION...4 SECTION 2 - SPECIFICATIONS...6 SECTION 3 - INSTALLATION...7

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

SPL Hub TABLE OF CONTENTS SECTION 1 - DESCRIPTION...2 SECTION 2 - SPECIFICATIONS...3 SECTION 3 - INSTALLATION...4

SIU-218 and SIU-2218

USER MANUAL MODEL Bidirectional (IEEE-1284) Line Driver/Converter

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

Contents INTRODUCTION...1 CARD SETUP...2 INSTALLATION TECHNICAL DESCRIPTION SPECIFICATIONS... 14

Cable and Port Specifications

16/24 Port 10/100 Auto-Sensing Dual Speed Ethernet Switch

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

4K HDR HDBaseT Extender B-560-EXT INSTALLATION MANUAL

USER MANUAL. MODELS 1205 and 1205/34. Synchronous V.35 Modem Eliminators

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

iconverter 2-Module Power Chassis

Perle SMI Media Converter Installation Guide

Model 282 Total Interface Isolation Module Reference Manual Rev. A Print Table of Contents 1.0 General Description 2.

DATA CONNECT ENTERPRISE

500 Business Center Drive Pittsburgh, PA USA CAGE 1BGJ7. SwitchMaster R5000 Series Ultra-Compact Ganged A/B Switching System

USER MANUAL. Model 2070 Series. V.24/X.21/V.35 to G.703 Interface Converter

Select a Data Communication Interface

An ISO-9001 Certified Company

M82xxD Fiber Optic RS-232 MicroModem Technical Manual

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

RS-232 Industrial Media Converter

Automated Tuner System Power Distribution Hub

OPERATOR S MANUAL MODEL DSU-56SA. 56 Kbps Stand Alone CSU/DSU

It s Under Control. Installation and Operation Guide CPB-1. Control Port Connecting Block V 1.1

Itona TC73yy Hardware User s Guide

DeviceMaster RTS 16-Port Hardware Installation

The specifications for the Cisco 7304 router are listed in Table A-1.

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

4170 POS System Installation Guide

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

USER MANUAL. MODEL 2014 Interface Powered RS-530 to V.35 Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

10/100/1000, 10G & 40G

-C5RS-LC RS232 EXTENDER

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Itona DxxS Hardware User s Guide

The Tri-State Box User s Manual

Installing the Cisco AS5400XM Universal Gateway

SyncLink GT Serial Adapter

GT- HE910-EUD. Product description Rev. 8 21/02/ Overview

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

Storage/Control I/O Module

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

HEC. General Operating, Maintenance and Installation Manual

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Installing the Cisco 2524 and Cisco 2525 Routers

E1/T1 Rate Converters

Quick Start Installation Guide

Cable and Port Specifications

XC300 VDSL Network Extender Owners Manual

Serial/Ethernet Converter

COMM+422.PCI USER MANUAL

TRC-190 User s Manual

RocketPort Plus Hardware Installation

EasySYNC Ltd. USB to Serial Converters Manual

solartron digital readout model no. DR600 DR700 installation manual

BACnet Router Start-up Guide

MEC-COM-M114. User s Manual

HDBaseT EXTENDER B-520-EXT-230-RS-W INSTALLATION MANUAL

MPF-1, Mains Power Filter User Manual

FCC Information. RoHS This product is RoHS compliant. SJ/T The following contains information that relates to China.

HydroLynx Systems, Inc. Model 50386D Decoder Instruction Manual

Agilent 70612B K18 Switch Matrix

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

RT Remote Translator and. WMC, IR-T, & RIK Controls

TRC-190 User s Manual

MEC-COM-M154. User s Manual

Broadband Automatic Disconnect Switch. User Manual

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

MODEL 805 USER MANUAL

Mini Driver V (Mini Driver MP with 5-Screw Terminal Block) MINI DRIVER MP

Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel...

Gateway Module Programmable in C

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

WallVIEW PTZ Systems WallVIEW 50i PTZ, WallVIEW 100 PTZ and WallVIEW 70 PTZ Pan/Tilt/Zoom Camera Systems

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

Metro-Optical Transport Access Nodes

Transcription:

TABLE OF CTENTS CHAPTER 1 - INTRODUCTI... Page 1 1.1 FUNCTIAL DESCRIPTI... Page 1 CHAPTER 2 - PRODUCT OVERVIEW... Page 2 2.1 FRT PANEL INDICATORS... Page 2 2.2 INTERNAL SWITCHES... Page 2 2.3 REAR PANEL POWER CNECTOR... Page 2 2.4 REAR PANERL DATA INTERFACE PORTS... Page 2 2.5 CLOCKING... Page 2 2.6 DATA INTERFACES... Page 2 2.7 EXTERNAL CLOCK OPTI... Page 2 2.8 CTROL SIGNAL FORCING... Page 3 2.9 DATA INTERFACE REMOVAL... Page 3... CHAPTER 3 - INSTALLATI... Page 4 3.1 VOLTAGE SELECTI... Page 4 3.2 VOLTAGE SELECTI FUSES... Page 4 3.3 POWER CNECTI... Page 4 3.4 DEFAULT CFIGURATI SWITCH SETTINGS Page 5 3.5 DATA PORT CNECTIS... Page 5 3.6 SWITCH SETTINGS... Page 5 3.6.1 DIP SWITCHES... Page 5 3.7 EXTERNAL CLOCK OPTI... Page 5... 4.0 - APPENDIX... Page 6 4.1 STRAP CHART CLOCK RATES... Page 7 4.1 STRAP CHART CTROL SIGNALS... Page 7 4.3 TECHNICAL OVERVIEW... Page 8 Page 9 5.0 - TECHNICAL SPECIFICATIS...

OPERATIS MANUAL UNIVERSAL DATA CVERTER Modem Eliminator UDC-ME 11 January 2011 FOR TECHNICAL SUPPORT CALL: East Coast Datacom, Inc. 245 Gus Hipp Blvd., STE 3 Rockledge, FL 32955 USA TEL: (321) 637-9922 FAX: (321) 637-9980 E-mail: info@ecdata.com Manufactured By: East Coast Datacom, Inc. WWW.ECDATA.COM Manual Part Number 184054 Rev - A

UDC-ME INSTALLATI AND OPERATIS MANUAL SAFETY WARNING WARNING Always observe standard safety precautions during installation, operation and maintenance of this product. To avoid the possibility of electrical shock, be sure to disconnect the power cord from the power source before servicing the device. Line voltages are present within the device when the power cord is attached to the device. DO NOT attempt to repair this device. Only qualified service personel can service this device. WARNING For AC powered devices which have 3 conductor power plugs (L1, L2 &GND or Hot, Neutral & Safety/Protective Ground), the wall outlet (or socket) must have an earth ground. PROPRIETARY NOTICE The information contained herein is proprietary to East Coast Datacom, Inc. Any reproduction or redistribution of this publication, in whole or in part, is expressly prohibited unless written authorization is provided by East Coast Datacom, Inc. WARRANTY NOTICE WARRANTIES: East Coast Datacom, Inc.(hereafter referred to as E.C.D.) warrants that its equipment is free from any defects in materials and workmanship. The warranty period shall be three (3) years from the date of shipment. E.C.D.'s sole obligation under its warranty is limited to the repair or replacement of defective equipment, provided it is returned to E.C.D., transportation prepaid, within a reasonable period. This warranty will not extend to equipment subjected to; lightning strikes, electrical surges, water damage, misuse, alterations, mishandling (dropped and damaged) or repair not made by E.C.D. or authorized by E.C.D. in writing. PUBLICATI NOTICE This manual has been compiled and checked for accuracy. The information in this manual does not constitute a warranty of performance. E.C.D. reserves the right to revise this publication and make changes from time to time in the content thereof. E.C.D. assumes no liability for losses incurred as a result of out-of-date or incorrect information contained in this manual.

CHAPTER 1 - INTRODUCTI UDC-ME INSTALLATI AND OPERATIS MANUAL 1.1 FUNCTIAL DESCRIPTI The UDC-ME allows two DTE devices (such as routers) to communicate within proximity of each other. The UDC-ME transmits data bi-directionally at clock rates of 1.2k up to 3.072Mbps between DTE devices. All clocking and signal crossover are provided within the UDC-ME. The unit is equipped with two interface slots that allow a host of serial interface cards to be utilized. The serial interface cards available are RS-232, RS-422/449, RS-530, X.21, V.35 and HSSI. The Serial Interface cards are interchangeable and may be mixed such as RS-232 to V.35 thus eliminating the need for an interface converter or changing expensive serial cards on a DTE device such as a router. The UDC-ME is also an excellent choice for testing router-to-router connections via the serial ports. The unit is an ideal choice for interconnecting your LAN or legacy mainframe equipment. Installation is fast and simple by setting the internal switches for Clocking, Carrier Operation and RTS to CTS delay. The UDC-ME has status LED's for each attached DTE device which allows the user to visually confirm the presence of clock and control signals. Also included are options for data or clock inversion. The UDC-ME utilizes state of the art digital CMOS technology to provide a feature filled product at a very affordable price. Our Field Programmable Gate Array (FPGA) design has allowed us to offer this product with a wide selection of clock rates. This design approach has also reduced the amount of clock jitter for high speed transmissions. The UDC-ME is housed in a sturdy metal enclosure and operates on 110/220VAC or optional -48V DC power. Typical MTBF figures are in excess of 150,000 hours of operation. The UDC-ME has a three year warranty and a 24 hour turnaround on warranty repairs. Router or Legacy DTE UDC-ME Modem Eliminator Rates of 1.2k to 3.072Mbps Router or Legacy DTE TYPICAL APPLICATI Figure 1.1 Page 1

CHAPTER 2 - PRODUCT OVERVIEW 2.1 FRT PANEL INDICATORS A Green LED marked PWR illuminates when AC Power has been applied. Two adjacent sets of Green LEDs, one for PORT A and another for PORT B, illuminate in union with individual port control signal activity. Both Port A and Port B indicators flash in union with Port A and Port B data interfaces(see section 2.4 Data Interfaces). 2.2 INTERNAL SWITCHES The UDC-ME has three(3) dip switches. The switches are marked SW1, SW2 and SW5. Switch SW1 allows the user to set the Clock Rate(s). Switches SW2 and SW5 allow the user to Invert the Clock and force control Signals. 2.3 REAR PANEL POWER CNECTOR Located on the back or rear of the product you will find an IEC POWER RECEPTACLE. The supplied power cord plugs into this receptacle. This receptacle also contains a fuse drawer. Two (2) fuses are located in this compartment. For 110 VAC +/- 10% operation the unit is equipped with slow blow 160ma Fuses. For 220 VAC +/- 10% operation the unit is equipped with slow blow 80ma Fuses. 2.4 REAR PANEL DATA INTERFACE PORTS Located adjacent to the IEC Power receptacle are the DATA INTERFACE PORTS. The ports are metal stamped PORT A and PORT B. The data interface modules plug into the UDC-ME main printed circuit board through these openings. The top two screws on the interface module hold the card into place. The front panel Port A and Port B indicators flash in union with Port A and Port B data interfaces. 2.5 CLOCKING The UDC-ME allows clock rates from 1.2k to 3.072Mbps. The unit has 32 selectable clock rates. 2.6 DATA INTERFACES UDC-ME INSTALLATI AND OPERATIS MANUAL The UDC-ME has a host of available DATA INTERFACES comprised of RS-232, V.35, RS-422/449, RS-530, X.21 and TTL. Each interface module is available in a DCE configuration, the true EIA or ITU recommended connector and female gender is provided. The V.35 interface modules are MR-34 male, with factory optional DB-25 female. This option can reduce cabling costs. 2.7 EXTERNAL CLOCK REFERENCE The UDC-ME allows external timing(if applicable) for applications requiring such via SW2 for either Port A or Port B. Page 2

UDC-ME INSTALLATI AND OPERATIS MANUAL 2.8 CTROL SIGNAL FORCING The UDC-ME Control Signals are forced on the main printed circuit card located at switch position SW5. LY use the Dip Switch to force control signals. When forcing control signals via SW5, you should see the control signal LED light illiminate on Channel A or Channel B. While each Data Interface Module has straps(3 pin header) that force select control signals, those straps are for other East Coast Datacom products. It will not harm the unit, but utilizing them can give false LED lights or operation. 2.9 DATA INTERFACE REMOVAL Disconnect the AC power source from the UDC-ME and disconnect the users data cables from the Data Interface Module(DIM). Located on back panel of the UDC-ME are PORT A and PORT B. Each DIM is plugged into and out of these ports through mating connectors. Remove the top cover using a phillips screwdriver, then remove the top two screws of the DIM. Gently pull the module from the UDC-ME housing. It may be easier to hold the edges of the DIM and rock the DIM back and forth as you pull the DIM out of the socket. PORT B PORT A INTERFACE MODULE SCREWS(2) REAR PANEL DATA INTERFACES 110/220VAC SWITCH Page 3

UDC-ME INSTALLATI AND OPERATIS MANUAL CHAPTER 3 - INSTALLATI CAUTI: Disconnect Power Before Servicing ATTENTI: Couper Le Courant Avant l' Entretien VORSICHT: Befor Deckung Abnehmen Mach Strom Zu 3.1 VOLTAGE SELECTI It is very important to check that the unit is set to the correct voltage setting for your application before applying AC power. Located on the rear of the unit you will find a rotary 110/220 VAC switch. Using a coin or small screwdriver, gently turn the switch to the appropriate power position as required for your installation (110 or 220 VAC). 3.2 VOLTAGE SELECTI FUSES Located on the back or rear of the product you will find an IEC Power receptacle. This receptacle contains a fuse drawer. Two (2) fuses are located in this compartment. For 110 VAC +/- 10% operation the unit is equipped with slow blow 5 x 20mm 160ma Fuses, E.C.D. Part # 714000. For 220 VAC +/- 10% operation the unit is equipped with slow blow 5 x 20mm 80ma Fuses, E.C.D. Part # 714001. Spare fuses may be purchased by calling East Coast Datacom or by contacting the fuse manufacturer: Little Fuse www.littlefuse.com or Shurter, Inc. at www.schurter.com Little Fuse Part #'s are: 160ma = 218.160 and 80ma = 218.080 Schurter, Inc. Part #'s are: 160ma = 034.3109 and 80ma = 034.3106 3.3 POWER CNECTI Before connecting the UDC-ME to an AC power source the top cover should be installed with the supplied #4-40 screws. AC power is supplied to the unit through a 2.3m (6.6 ft) cord terminated by a grounded 3-prong plug. Select an appropriate location accessible to and within four to five feet of an AC outlet. The AC Power source MUST be grounded or the units warranty will be void. FUSE DRAWER Power Connection Figure 3-1 110 / 220 VAC SWITCH IEC POWER CNECTOR Page 4

UDC-ME INSTALLATI AND OPERATIS MANUAL 3.4 DEFAULT CFIGURATI SWITCH SETTINGS The UDC-ME is factory configured as follows: 1) Clock Source - Internal 2) Control Signals - All Signals Passed if present 3) Sync Clock Rate - 1.2k 4) Chassis to Signal GND - Not Connected If your system application requires one or more of the default settings to be changed, this is accomplished by removing the top cover to change Dip Switches SW2-SW5 or to connect chassis to signal ground. 3.5 DATA PORT CNECTIS Before applying AC Power to the unit, the users cabling to the UDC-ME Data Interfaces should be connected. Straight through shielded cables should be used. PORT A must always have a DCE interface module plugged into the port and connect to a DTE device. PORT B must always have a DTE interface module plugged into the port and connected to a DCE device. 3.6 SWITCH SETTINGS 3.6.1 DIP SWITCHES The UDC-ME has three(3) dip switches. The switches are marked SW1, SW2 and SW5. Switch SW1 allows the user to set the Clock Rate(s). Switches SW2 and SW5 allow the user to Invert the Clock and force control Signals. 3.7 EXTERNAL CLOCK OPTI The UDC-ME allows external timing(if applicable) for applications requiring such via SW2 for either Port A or Port B. Page 5

UDC-ME INSTALLATI AND OPERATIS MANUAL 4.0 - APPENDIX 4.1 STRAP CHART SME-ME BAUD RATE SETTING CHART Switch settings SW1 1 2 3 4 5 6 7 8 1,200 Unused Unused Unused 2,400 " " " 4,800 " " " 7,200 " " " 9,600 " " " 14,400 " " " 16,000 " " " 19,200 " " " 28,800 " " " 32,000 " " " 38,400 " " " 48,000 " " " 56,000 " " " 57,600 " " " 64,000 " " " 72,000 " " " 96,000 " " " 128,000 " " " 192,000 " " " 256,000 " " " 384,000 " " " 512,000 " " " 768,000 " " " 1,024,000 " " " 1,280,000 " " " 1,472,000 " " " 1,536,000 " " " 1,544,000 " " " 1,920,000 " " " 1,984,000 " " " 2,048,000 " " " 3,072,000 " " " Page 6

UDC-ME INSTALLATI AND OPERATIS MANUAL Internal Clock Generator External Clock f/port A CTS Port A follows RTS Force CTS Port A SW2: 1 2 3 4 5 6 7 8 CTS Port A Delay = 0 ms CTS Port A Delay = 6 ms CTS Port A Delay = 12 ms CTS Port A Delay = 24 ms Internal Clock Generator External Clock f/port B CTS Port B follows RTS Force CTS Port B CTS Port B Delay = 0 ms CTS Port B Delay = 6 ms CTS Port B Delay = 12 ms CTS Port B Delay = 24 ms Port A TXC Normal Port A TXC Inverted Port A RXC Normal Port A RXC Inverted Port B TXC Normal Port B TXC Inverted Port B RXC Normal Port B RXC Inverted Port A DCD Follows Port B CTS Port A DCD Always Port A DSR Follows Port B DTR Port A DSR Always Port B DCD Follows Port B CTS Port B DCD Always SW5: 1 2 3 4 5 6 7 8 Port B DSR Follows Port B DTR Port B DSR Always Bold denotes factory default settings *** *** Page 7

4.2 UNIT OVERVIEW UDC-ME INSTALLATI AND OPERATIS MANUAL POWER SUPPLY POWER ENTRY & FUSE DRAWER WARNING PORT A PORT B DIP SWITCHES SW1, SW2 & SW5 Page 8

UDC-ME INSTALLATI AND OPERATIS MANUAL Application Interconnection of two DTE (Terminal) devices located within proximity of each other Capacity Two (2) DTE's Serial Data Interface RS-232, RS-422/449, RS-530, X.21, V.35 and HSSI Data Format Data Transparent at all Data Rates Inversion Option Data Inversion or Clock Inversion Data Rates 1.2k, 2.4k, 4.8k, 7.2k, 9.6k, 14.4k, 16k, 19.2k, 28.8k, 32k, 38.4k, 48k, 56k, 57.6k, 64k, 72k, 96k, 128k, 192k, 256k, 384k, 512k, 768k, 1.024M, 1.280M, 1.472M, 1.536M, 1.544M, 1.920M, 1.984M, 2.048M, 3.072M Indicators Power, TXD, RXD, TXC, RXC, RTS, CTS, DTR, DCD Surge Protection Main power supply Power Source AC Mains: 100-120 to 200-220VAC @10%, 50/60Hz, 0.16/0.08A, external 110/220 volt select switch, IEC Power Inlet, (2) 5mm Fuses DC Mains: DC Voltage, Input Range of -36 to -72vdc Current Draw at 48vdc: 75ma @ 3.6watts Environmental Operating Temperature...32º to 122º F (0º to 50º C) Relative Humidity...5 to 95% Non-Condensing Altitude...0 to 10,000 feet Dimensions Height... 1.75 inches (4.44 cm) Width... 9.00 inches (20.86 cm) Length... 9.00 inches (22.86 cm) Warranty Three Years, Return To Factory ORDERING INFORMATI Main Unit Part Number: 189000 Model: UDC-ME Description: UDC Modem Eliminator, rates of 1.2k to 3.072M Serial Interface Cards, Two Cards Required Per UDC-ME, may be the same card twice or any combination. PART NUMBER 129014 129010 129011 129012 129013 151028 SERIAL CARD RS-232 DCE I/M, V.35 DCE I/M, RS-530 DCE I/M, RS-422/449 DCE X.21 DCE I/M, HSSI DCE I/M, 50 INCLUDED WITH EACH UNIT: 1) Operations Manual 2) U.S.A. Grounded Power Cord, Part # 713015 3) Optional Power Cords A) United Kingdom, Part # 713016 B) Continental Europe, Part # 713017 C) Other: Specify Country on Purchase Order OPTIAL ACCESSORIES 1) Spare Data Center Fuses A) 160ma Fuse, Qty (2) Part # 714000 B) 80ma Fuse, Qty (2) Part # 714001 For further detailed technical information on this product, contact East Coast Datacom Technical Assistance toll free at (800) 240-7948 OTHER EAST COAST DATACOM PRODUCTS MODEM AND PORT SHARING DEVICES INTERFACE CVERTERS SIGNAL REGENERATORS LINE DRIVERS Weight 2 pounds (0.914Kg) Page 9