Assembly and Operating Instructions Door Control

Similar documents
Assembly and Operating Instructions. NFC module for BDC-i440 control units

Assembly and Operating Instructions. M2 module for BDC-i440 control units

P5/20M - P13/9M R7/17M - L120/11M

Assembly and Operating Instructions Tubular drives for sunshades

Product and functional description

Operating instructions. Standstill monitor A / / 2011

Sliding shutter control Aluminium shutters

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

Operating instructions. Speed monitor D / / 2014

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

GIGAcontrol T. EN Translation of the Original Installation and Operating Manual V DRE-Rev.C_EN

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC Functional Safety

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating and mounting instructions

Siemens Industrial s

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Magforce STD/STG/STW/SKD/SKS/STN

Product and functional description

Please keep these instructions for further reference.

Electrical Actuators

6173 AG GJB A0138

Electrical Actuators

Installation manual plugs and connectors with screw connection (16/32 A)

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Siemens Drives & PLCs

Product and functional description

Performance Level PL d. Safety Category Type 3. Automatic reset / Manual reset. Very short reaction times. Connection of several signal transmitters

Operating Instructions

Operating instructions RFID evaluation unit DTE / / 2016

DALI Professional Controller-4. Control unit Operating instructions

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

Overview of types. Technical data

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

Please keep these instructions for further reference.

Operating instructions. Monitor FD / / 2013

Install Motor Controller User Manual

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

GTE Industrieelektronik GmbH Product division control units WST 18. Operating Instructions No Compact module control for

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

ABB i-bus EIB. Shutter Actuator, 2-fold, 6 A, 230 VAC, MDRC JA/S 2.6.1, GH Q R0111

Operating Manual -ENGLISH- Page 1 KWG-ISO

Supplementary operating instructions for your air curtain system Controller TMC 500

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

Installation Instructions Retrofitting Set Fistune Antenna Module Audi A5 8T Sportback

Product and functional description

User Manual - Energenie MiHome Double Wall Sockets (MIHO07, MIHO021, MIHO022, MIHO023)

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

Operation Manual Series W-500

TG basic 1. Appliance tester for testing protective measures in accordance with DIN VDE (DIN EN 62638)

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

SNO 4003 K plus. Areas of application for the unit. Connection circuit diagrams. Intended use. Competent persons. Equipment and functional description

DPX-620III 6-Ch. dimmer pack. user manual

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

Operating Manual FPGA-based High-Speed Micro-PLC

Manual Control Unit GFC 32

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Flexoled FTP3HP RGB LED DMX Driver

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

Device manual SINAMICS SINAMICS G120. Distributed inverter box Control cabinet for wall or floor mounting.

Product and functional description

Control unit IndraDrive Commissioning Linear axis LDx with IndraDrive control unit

Hardware Manual RM CANview

Original operating instructions Safety relay with relay outputs G1501S / / 2016

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Original operating instructions Fail-safe inductive sensor GI712S

MSI-RM2 Safety Relays

CS300 SYSTEM. Pro-Line. Operating instruction

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Original operating instructions Fail-safe inductive sensor GG711S

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Fundamentals of circuits with contacts

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Rako RAK4-R Instruction Manual

Manual. Decentralized Extra-Low Voltage Servo Drive CMP ELVCD Functional Safety * _0717*

* _1216* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC..

Installation Instructions

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Installation Notes Retrofit-Set DAB/DAB+ - Antenna Module Audi A7 4G

Manual Simatek Control Unit GFC 32

Docking station Order no Operation and installation instructions. 1 Safety instructions. 2 Structure of the device.

ISG Isolated DIN Rail Mount Signal Conditioner Issue: Revision A Technical User Manual

Original instructions JSHD4 Three-position enabling device

INSTALLATION INSTRUCTIONS

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Transcription:

S10 GB Assembly and Operating Instructions Door Control Important information for: Fitters Electricians Users Please forward accordingly! These instructions must be kept for future reference.

Assembly and Operating Instructions Table of Contents General... 2 Warranty... 2 Intended use... 2 Safety information... 3 Installation instructions... 3 Functional overview... 4 Commissioning of the system... 5 Functional description... 5 What should you do, if...?... 6 Wiring diagram... 6 Connection plan... 7 Technical data... 7 General The S10 control is a quality product with many performance features and advantages. Please observe these operating instructions during installation and setting up of the equipment. Warranty Structural modifications and incorrect installation which are not in accordance with these and our other instructions can result in serious injuries, e.g. crushing of limbs. Therefore, structural modifications should only be carried out with our prior approval and in accordance with our instructions, particularly the information contained in these Assembly and Operating Instructions. Any further processing of the products which does not comply with their intended use is not permitted. The end product manufacturer and fitter have to ensure that all the current statutory, official regulations and, in particular, EMC regulations are adhered to during utilisation of our products, especially with regard to end product assembly, installation and customer advice. Intended use The door control S10 is a reversing contactor control unit for controlling Becker roller and sectional door drives with mechanical limit switches. A safety edge mechanism in connection with an external evaluator is required for downward door movement in self-locking mode. A control with brake module is required when using roller door drives with an external brake. Other applications, utilisation and modifications are not permitted in order to protect the safety of the users and others, since these actions can impair the system s safety, resulting in personal injuries and property damage. Becker-Antriebe shall not accept liability for damages arising from such actions. Always observe the information in these instructions when operating or repairing the system. Becker-Antriebe shall not accept liability for damages resulting from incorrect usage. 2

Safety information Please read these instructions carefully before operation. Work on the electrical equipment must be performed by a qualified electrician. Please comply with the legal requirements (safety, accident prevention), particularly the regulations of the employers liability insurance association (BGR 232) and EN 12453 Safe use of power-operated doors, as well as the applicable EN standards. The system installer is responsible for correct assembly, instruction of the operator and for issuing of the CE mark. The operator must ensure that the system is only operated in perfect condition and that the safety devices are regularly checked by an expert. A damaged mains cable with CEE plug has to be replaced immediately by a qualified electrician. In the case of roller doors, the system construction on site has to offer suitable protection for the curtain, so that if it is extended beyond the end limits, it does not cause any dangerous situation and risk to life. The increased safety requirements of the integrated operating elements result in 50,000 and 100,000 operations for deadman and self-locking operation respectively. Installation instructions Installing the control 1. Installing the control The control device is intended for use indoors and is to be installed at the desired operating height. The housing cover with the triple pushbuttons can be removed during installation by means of the plug-in connection (connector is retained and engages audibly when fitted). During commissioning, the cover can be screwed on with just two screws so that it is laterally offset (open housing facilitates operation of buttons). 2. Installing the supply point Mount a CEE 16A/6h socket beneath the control or connect the control via a permanently laid installation cable. The control must have all-pole protection against short circuits and overload provided by a fuse of max. 10A per phase. Caution During all wiring work, the system must be disconnected from the power by removing the CEE plug or switching off the main switch. Observe the applicable EN guidelines during installation. 3. Motor/control connection The drive cable (12-wire) must be connected to the appropriate terminals in accordance with the connection plan (not required if connection has already been carried out by Becker). The terminal designations correspond to the numbers of the drive cable wires (without wire 4 and 10). The fitted CEE plug can be used as the main switch. If the control is connected without the CEE plug (e.g. permanent connection), a main switch must be connected into the mains feed, which disconnects all the poles according to the overvoltage category III. Separate connection cables are required for outdoor use, and for PVC connections these cables have to be laid in a protective tube. 3

Assembly and Operating Instructions Functional overview Functions Setting mode (Up/Down in deadman mode) Self-locking mode for upward door movement Deadman mode for downward door movement (self-locking mode with external evaluator) External triple pushbutton Slack cable input / Emergency Stop Partial opening (function switch S8) Traffic light/door status display (function switch S7) S10 with integrated pushbuttons S10 with external pushbuttons Direct mount drive Direct mount drive Mains connection or 3x400 Volt CEE plug CEE plug (16A) (optional) External pushbuttons 4

Commissioning of the system Control Checking the running direction Insert the CEE plug into the CEE socket or switch on the external main switch. Now use the UP and DOWN buttons to check whether the running direction of the door corresponds to these commands. If the running direction does not correspond to the arrow direction: Disconnect the CEE plug or switch off the main switch. Swap the mains connection terminals, e.g. swap phases on the phase reverse CEE plug or swap over L1 and L3 connection inside the panel (see connection plan). Now start commissioning again. Setting the end limits The control is factory set to ensure that movement in the UP and DOWN direction is carried out in self-locking mode and deadman mode respectively. To facilitate moving to the final position when setting the limit switches, it is possible to switch movement in the UP direction from self-locking mode to deadman mode by opening the bridge B3-B4. Lower end limit setting Move the door to the lower end limit via the DOWN button (deadman mode). Approach the desired lower end limit by inching towards it. Set the limit switch cam for DOWN (black) according to the operating instructions of the direct mount drive being used. Upper end limit setting Move the door to the upper end limit via the UP button (deadman mode). Approach the desired upper end limit by inching towards it. Also set the limit switch cam for UP (grey) according to the operating instructions of the direct mount drive being used. Setting the safety limit switches The safety limit switches (yellow) are set with an approx. 3 delay to the respective operating limit switch. Observe the relevant information in the operating instructions of the direct mount drive. If a safety limit switch is contacted, the control voltage is switched off. The relevant control cam must then be turned away manually from the limit switching micro switch or cleared by manual activation (e.g. a crank). Setting the function switch S7 With the special function switch S7 (orange) it is possible, to control an external device or relay. For example, this enables the connection of a traffic light function or door status display. Make sure that the function switch is not potential free (see wiring diagram). Setting the function switch S8 With the function switch S8 (green) it is possible, e.g., to set the partial opening position of a door via an external selector switch. Make sure that the function switch is not potential free (see wiring diagram). Note Basically, the exact adjustment of the limit positions is carried out via the fine adjustment screw of the respective control cam (also refer to the operating instructions of the door drive). Functional description Integrated operating elements Door UP Pressing the UP button (front) opens the door in self-locking mode. The door stops automatically when the upper end limit is reached or if a safety function is actuated (e.g. Emergency Stop button). If you wish to change to the UP direction while the door is moving downwards, the STOP button has to be pressed first. STOP Press the STOP button (front) to stop the opening or closing door immediately at any position. Door DOWN Pressing the DOWN button (front) closes the door in deadman mode. The door stops automatically when the lower end limit is reached. Downward movement in self-locking mode (bridge A5/B5) is only permissible with an additional external safety edge evaluator in accordance with EN 12453. Control inputs and external pick-ups External pick-ups (UP STOP DOWN) An additional triple pushbutton which has exactly the same functions as the buttons on the front of the control can be connected. EMERGENCY STOP button (EMERGENCY STOP) An external EMERGENCY STOP button can be connected in series to the external STOP button. Slack cable limit switch (EMERGENCY STOP) A slack cable limit switch can be connected in series to the external STOP button. 5

Assembly and Operating Instructions What should you do, if...? Possible faults: S10 does not switch on when the power supply is switched on. No response when buttons arepressed. The door only opens in deadman s mode. Possible causes and remedy: - Check mains feed (fuse). - Check safety circuit (e.g. emergency stop switch, slack cable limit switch, safety limit switch). - Check that connection wires are securely fixed in the terminals. - Check STOP button. (bridge A3/A4). - Check safety circuit. Bridge B3/B4 is missing. Wiring diagram STOP INTERNAL When using the S10 control without an integrated button, the INTERNAL STOP is bridged by a jump plug (included) STOP EXTERNAL UP EXT. UP INT. DOWN EXT. DOWN INT. 6

Connection plan Limit switches in the drive S1F Safety limit switch OPEN S2F Safety limit switch CLOSED S3F Safety switch emergency activation S4F Thermal switch S5 Operating limit switch OPEN S6 Operating limit switch CLOSED S7 Functional switch S8 Functional switch S10 Control STOP CLOSED OPEN External control via a 3-way pushbutton Connection cable 5 x 2 mm2 Connection functions: B1-B2 Stop during downward movement (normally closed contact) B3-B4 Upward movement in selflocking mode A5-B5 Downward movement in selflocking mode (only permissible with a safety edge) A3-A4 External STOP command CEE socket 16A Max. 10 A 230/400 V 50/60 Hz 3~/N/PE Technical data Type: S10 Power supply: 3 x 400/230V 50/60 Hz (L1, L2, L3, N, PE) Max. rated power of motor: 2 KW Weight: 0.9 kg Dimensions: 110 x 180 x 90 (W x H x D) Class of protection: IP 54 (IP 65 optional), for indoor use only 7

Becker-Antriebe GmbH 35764 Sinn/Germany www.becker-antriebe.com 4023 630 210 0 01/08