RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Similar documents
RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

RE9RA21MW7 off-delay timing relay s V AC -

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

RM35LM33MW liquid level control relay RM35-L V AC/DC

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

RE8TA31BU industrial timing relay s - type A - 24 V AC/DC, V AC - 1 C/O

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

RE7YA12BU. Main. Contacts type and composition Component name Time delay type. 24 V AC/DC at 50/60 Hz V AC/DCat 50/60 Hz

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

RM35LM33MW liquid level control relay RM35-L V AC/DC

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

RM4TR31 three-phase network control relay RM4-T - range V

RM4TA32 three-phase network control relay RM4-T - range V

RE7RM11BU off-delay timing relay with control contact s - 24 V AC DC - 1OC

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

RMCN22BD Analog Converter ma - for Zelio Analog

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

RM35TF V AC

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

RE8YG31BUTQ industrial timing relay s - type Qc - 24 V AC/DC, V AC - 1C/O

TM3TI4 module TM3-4 inputs temperature

RM4LA32M liquid level control relay RM4-L V AC

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

SR3B261FU modular smart relay Zelio Logic - 26 I O V AC - clock - display

TM3DI16G module TM3-16 inputs spring

RM4JA31M current measurement relay RM4-J - range ma V AC

ZBRN1 access point- 2 RJ V AC/DC-4 displays-5 LEDs-Eth-Modbus-wireless radio

SR2B121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - display

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

ABS2EC01EB input interface module mm - solid state - 24 V DC

TM3SAF. Main. Device short name

RPM42P7 power plug-in relay - Zelio RPM - 4 C/O V AC - 15 A - with LED

ABL8BBU24200 battery control module V DC - 24 V - 20 A - for regulated SMPS

ABL1RPM24100 regulated SMPS - single phase V input - 24 V output W

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

XMLR400M1P25 Pressure sensors XMLR 400bar - G 1/4-24VDC ma - PNP - M12

XMLK006B2C21 pressure sensor XMLK bar - G 1/4A mA - DIN - set of 1

ABL1REM24100 regulated SMPS - single phase V input - 24 V output W

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

RM17UB3. Price* : USD

RXM4AB1BD miniature plug-in relay - Zelio RXM - 4 C/O - 24 V DC - 6 A

RSB1A160JD interface plug-in relay - Zelio RSB - 1 C/O - 12 V DC - 16 A

ABL4RSM24050 regulated SMPS - 1 or 2 phase V AC - 24 V - 5A

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

ZBRN1. Main. Device short name

ABL1REM Main. Rated power in W. Power supply output current V. <= 100 Aat 230 V AC. 2.5 Aat 240 V

XMLP200PD730 pressure transmitter - XMLP - 200psi - 1/4"18NPT V - M12 - set 1

TM221M16R controller M IO relay

TM221CE24R controller M IO relay Ethernet

RM4JA01F current measurement relay RM4-J - range ma V AC

TM3SAK. Main. Device short name

TM241CE24T controller M IO transistor PNP Ethernet

TM258LD42DT4L compact base M I/O - 24 V DC

TM221CE40T controller M IO transistor PNP Ethernet

TM3AI4 module TM3-4 analog inputs

RM4JA32MW current measurement relay RM4-J - range A V AC DC

SR2E121B compact smart relay Zelio Logic - 12 I O - 24 V AC - clock - no display

XB7EV07BP round pilot light Ø 22 - clear - integral LED - 24 V - screw clamp terminals

RM4UA33M voltage measurement relay RM4-U - range V V AC

TM258LF42DT compact base M I/O - 24 V DC - CANopen

TM241CE40R controller M IO relay Ethernet

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

TM3TI4 module TM3-4 inputs temperature

RPM13F7 power plug-in relay - Zelio RPM - 1 C/O V AC - 15 A - with LED

TM3TI8T module TM3-8 inputs temperature

ABL8MEM24006 regulated SMPS - 1 or 2-phase V AC - 24 V A

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

ABR1S102B. Main. Contacts type and composition [Uc] control circuit voltage Control circuit type

XCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20

XCKJ10559H7 limit switch XCKJ - thermoplastic round rod lever 6 mm - 1NC+1NO - snap - 1/2NPT

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO

XCKJ10511 limit switch XCKJ - thermoplastic roller lever - 1NC+1NO - snap action - Pg13

ABE7R16S210 sub-base - soldered electromechanical relays ABE7-16 channels - relay 10 mm

ABL8RPS24100 regulated SMPS - 1 or 2-phase V - 24 V - 10 A

Transcription:

Characteristics StarDelta Timing Relay 0.05s 300h 24 240V AC/DC 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Zelio Time Modular timing relay Relay RE22 8 A Complementary Contacts type and composition Time delay type Time delay range Control type [Us] rated supply voltage Release input voltage Voltage range 2 C/O timed contact, cadmium free Qt 0.3...3 s 1...10 s 0.05...1 s 3...30 s 10...100 s 30...300 s 3...30 min 30...300 min 3...30 h 30...300 h Diagnostic button Rotary knob 24...240 V AC/DC at 50/60 Hz <= 2.4 V 0.85...1.1 Us Supply frequency 50...60 Hz (+/ 5 %) Connections terminals Tightening torque 0.6...1 N.m conforming to IEC 609471 Housing material Screw terminals : 2 x 0.2...2 x 1.5 mm², AWG 24...AWG 16 flexible cable with cable end Screw terminals : 1 x 0.2...1 x 2.5 mm², AWG 24...AWG 14 flexible cable with cable end Screw terminals : 2 x 0.5...2 x 2.5 mm², AWG 20...AWG 14 solid cable without cable end Screw terminals : 1 x 0.5...1 x 3.3 mm², AWG 20...AWG 12 solid cable without cable end Selfextinguishing Repeat accuracy +/ 0.5 % conforming to IEC 618121 Temperature drift Voltage drift +/ 0.05 %/ C +/ 0.2 %/V Setting accuracy of time delay +/ 10 % of full scale at 25 C conforming to IEC 618121 Insulation resistance 100 MOhm at 500 V DC conforming to IEC 606641 Recovery time Immunity to microbreaks Power consumption in VA Power consumption in W Switching capacity in VA Minimum switching current Maximum switching current 120 ms (on deenergisation) <= 10 ms 3 VA at 240 V AC 1.5 W at 240 V DC 2000 VA 10 ma 5 V DC 8 A The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein. Sep 7, 2015 1

Maximum switching voltage Electrical durability Mechanical durability 250 V AC 100000 cycles for 2 A at 24 V DC1 100000 cycles for 8 A at 250 V AC1 10000000 cycles Rated impulse withstand voltage 5 kv for 1.2...50 µs conforming to IEC 606641 Power on delay < 100 ms Creepage distance 4 kv/3 conforming to IEC 606641 Overvoltage category III conforming to IEC 606641 Mounting position Any position Mounting support 35 mm DIN rail conforming to EN/IEC 60715 Status LED Product weight Yellow LED (slow flashing) for timing in progress and output relay energised Yellow LED (fast flashing) for timing in progress and output relay deenergised Yellow LED (steady) for output relay energised Green LED backlight (steady) for dial pointer indication 0.105 kg Environment Dielectric strength Standards IEC 618121 UL 508 Directives Product certifications 2.5 kv for 1 ma/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 618121 2004/108/EC electromagnetic compatibility 2006/95/EC low voltage directive CCC CE CSA GL UL RCM EAC China RoHS Ambient air temperature for operation 20...60 C Ambient air temperature for storage 40...70 C IP degree of protection IP50 (front panel) conforming to IEC 60529 IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 Pollution degree 3 conforming to IEC 606641 Vibration resistance 20 m/s² (f = 10...150 Hz) conforming to IEC 6006826 Shock resistance 5 gn (in operation) (duration = 11 ms) conforming to IEC 60068227 15 gn (not operating) (duration = 11 ms) conforming to IEC 60068227 Relative humidity 95 % at 25...55 C Electromagnetic compatibility Immunity to microbreaks and voltage drops (test level: 100 % 20 ms) conforming to IEC 61000411 Immunity to microbreaks and voltage drops (test level: 30 % 500 ms) conforming to IEC 61000411 Fast transient bursts (test level: 2 kv, level 3 direct contact) conforming to IEC 6100044 Conducted RF disturbances (test level: 10 V, level 3 0.15...80 MHz) conforming to IEC 6100046 Radiated radiofrequency electromagnetic field immunity test (test level: 10 V/m, level 3 80 MHz...1 GHz) conforming to IEC 6100043 Electrostatic discharge (test level: 8 kv, level 3 air discharge) conforming to IEC 6100042 Electrostatic discharge (test level: 6 kv, level 3 contact discharge) conforming to IEC 6100042 Surge immunity test (test level: 2 kv, level 3 common mode) conforming to IEC 6100045 Surge immunity test (test level: 1 kv, level 3 differential mode) conforming to IEC 6100045 Fast transients immunity test (test level: 1 kv, level 3 capacitive connecting clip) conforming to IEC 6100044 2

Dimensions Drawings Dimensions 3

Connections and Schema Wiring Diagram 4

Technical Description Function Qt: StarDelta Relay (2 CO with Split Common) Description On energisation of power supply, the output R1 & R2 initializes at its initial state such that energizes STAR CONTACTOR + MAIN CONTACTOR and the timing T starts (STAR connection time duration starts).at the end of the timing period T, the output R1 closes such that deenergizes STAR CONTACTOR and causes t transition time starts.at the end of the transition time, the output R2 closes such that energizes DELTA CONTACTOR. Function: 2 Outputs t : 20, 40, 60, 80, 100, 120, 140 ms Legend U T t R1 R2 Relay deenergised Relay energised Output open Output closed Supply Timing period Delay to switch ON Delta contact output Star contact output Delta contact output 5