ACENDIS EMERGENCY ACENDIS APM-700 / 700 XL MODULAR PATIENT MONITOR

Similar documents
PW 406. Features &Benefits: Multi parameters Patient monitor

Patient Monitoring Systems. Patient Monitor Vital Sign Monitor Pulse Oximeter

2012/2/3. imec12/10/8

TRANQUILITY VS VERSATILITY IN VITAL SIGNS A M E R I C A S TRANQUILITY VS A M E R I C A S

Cardiostart. Biphasic Defibrillator Monitor

Product Specifications

Dependable healthcare equipment; maintained to exacting standards. Patient Monitoring Systems. We re here for life.

INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications.

Argentine Manufacturer of Hospital Equipment. Electrocardiograph Pulse Oximeters Vital Signs Monitors

SL2400 Compact Monitor

91370 SL2600 Compact Monitor

Propaq LT Monitors. Propaq LT Base Model. Propaq LT with Wireless Option/ Legendary quality and durability Heart rate, 3-or 5-lead ECG, SpO 2

EC-12RT Resting ECG Machine. Technical Specification

etco 2 SpO 2 IBP medlab 2017/2018 OEM Modules for Patient Monitoring medizinische Diagnosegeräte GmbH

STEP 2: VITALSBRIDGE TO PATIENT MONITOR CONNECTION GUIDE VITALSBRIDGE AND 100

Infinity Delta and Delta XL Patient Monitors

Addendum No. 2 Reference: ITB Procurement of Medical Equipment for the Intensive Care Unit at Alia Hospital Hebron

FlowAnalyser Product Line

Infusion Pumps. Website: Kizlon Medical

Cardiac Monitoring Catalog USA

Infinity Delta and Delta XL Infinity Bedside Solutions

DPM 4 Patient Monitor. Service Manual

FlowAnalyser TM Product Line. When it comes to precision, I rely on the Swiss legendary devotion to detail.

INTEGRATED MEDICAL SOLUTIONS

Vet BP. Vet30 VITAL SIGNS. Continuous Vital Signs Monitor for Companion Animals

Propaq Vital Signs Monitors

ipm-9800 Patient Monitor Service Manual

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS

QUICK REFERENCE GUIDE

ECG100S. General Information. Product Code

Weight Height WxDxH Cuff Size. Housing Program Environmental Conditions

Tesla M3 MRI Patient Monitor

Patient Simulator Series

MONITOR/DEFIBRILLATOR CONTROLS, CONNECTIONS AND INDICATORS

STEP 6: USING THE VITALSBRIDGE WITH A STANDARDIZED PATIENT VITALSBRIDGE AND 100

BeneVision Default Settings

ARGUS PRO LifeCare 2. Patient monitor, 12-channel ECG, defibrillator and pacemaker in a compact format F A C T U R M A N U A N D I N E D E U R O I G N

All Products of Mediana

BeneVision DMS Workstation Default Settings

R Series Configuration Manual

Integrate with electronic health records (EHRs).

Hardware and Components: Philips Monitors in Critical Care

the next generation life energy

Professional Health Solutions

ECG MACHINES. Kizlon Medical. Website:

Mindray North America. Patient Monitoring FAQ s

ECG200+ General Information. ECG200+ Product Code General Name

Infinity M540 monitor Infinity M500 docking station

Philips PageWriter Touch ECG

VS-900. Vital Signs Monitor. Service Manual

Pulse Oximetry Testing. Pulse Oximetry Testing. Coming Soon! Available 4th Qtr bcgroupintl.com. Features - FSX-1200 FSX-1200

imec12/imec10/imec8 Patient Monitor Service Manual

Portable Video Laryngoscope

LEGAL NOTICE INVITATION TO SUBMIT BIDS

Hybrid. powered. 20BT lite / 20BT / 40BT. 20 lite / 60. Model mex+20bt lite mex+20bt mex+40bt. Model mex+20 lite mex+20 mex+40 mex+60 mex+100

Acuity LT Hardwired Central Monitoring System

Neonatal Care System. Infant Incubator Infant Warmer Phototherapy

PRODUCT SHEET. NON-INVASIVE SMALL ANIMAL TAIL BLOOD PRESSURE SYSTEMS NIBP250 Blood Pressure Amplifier NIBP200A Blood Pressure System

Tempus Pro Monitoring Platform

T34 is the new standard in ambulatory syringe pumps offering a comprehensive range of features designed to maximise safe, economic and simple

«The compact and mobile testing device for ventilators.»

Vmed Technology. PC-Display Wireless Monitoring Software. For all Vmed Wireless Monitors. Installation, Setup and User Instructions Version 2.

Electrocardiograph Electroencephalograph

ipm 12/iPM 10/iPM 8 ipm 7/iPM 6/iPM 5 Patient Monitor Service Manual

MONITOR VITAL SIGNS W/SPO²,W/CAPNO TOC

LBVR1718. Description. Features channel paperless recorder

SPECIFICATIONS HAND HELD PARTICLE COUNTER KC Higashimotomachi, Kokubunji, Tokyo , Japan

X SeriesTM. Xtremely. Small, Light, and Powerful

Touch Operator Interface GP4000SERIES.

VitalsBridge. Directions for Use MODEL VB2.0

Control Panel CP600 CP651, CP651-WEB

Making Simulation Easier. Laerdal Simulation Solutions. laerdal.com. laerdal.com. TM SimPad PLUS

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

The Qube compact monitor delivers both simplicity and style. VERSATILE INTRODUCING QUBE

BSM- 9510J BSM- 9510K MU- 950RJ MU- 950RK RY- 002PA AY- 900PA AY- 910PA AA- 900PA WS- 920PA EK- 900P. Life Scope M BEDSIDE MONITOR BSM-9510

Datenblatt / Specifications. ACR880 GPRS Portable Smart Card Terminal. idvation GmbH

ml/h ml/h ml/h ml/h or off or off )or off

MD300 C5 Pediatric Oximeter

Rigel Medical Product Brochure Medical Test Equipment. rigelmedical.com

EGIL Circuit breaker analyzer

i 4 imm Compact Critical Care Monitor GE Healthcare Modular monitoring for critical care

C7110C1001A / C7110D1009A WALL MODULES

Test equipment, adapters and facilities

EGIL Circuit breaker analyzer

Control Panel CP600 CP635, CP635-B, CP635-WEB

DMT345 and DMT346 Dewpoint Transmitters

BIo Signal TOtal Solution.

Output signal active note. Output signal. temperature DC V, DC V DC V, DC V DC V

Modular Patient Monitor ---- CritiVue 70. Modular Patient Monitor ---- CritiVue 60. Multiparameter Patient Monitor ---- M9500

ACR880 GPRS Portable Smart Card Terminal

Portable low-pressure controller Model CPC2000

EGIL Circuit breaker analyzer

Providing critical patient information reliably at critical times

MED MI 1005 Network Isolators

UPS Emergency Bed Power Unit

ProSim Vital Signs Simulators

Professional Health Solutions

CSB-Rack. Robust and reliable for automated online capture of data. Programmed for Your Success

Defibrillation made simple

Product: ST-Win Basic

Transcription:

ACENDIS EMERGENCY Mobile Server () & Central Monitoring System ACENDIS APM-700 / 700 XL MODULAR PATIENT MONITOR

APM-700 / 700 XL MODULAr anaesthesia and icu MONITOR The ACENDIS APM-700 / 700 XL modular ICU monitor series is capable of being utilised in all clinical areas. The large display allows clear observation in long distance, especially suitable for easy ICU room checking and monitoring during night. The APM-700 / 700 XL is assembled with numerous parameters of various modules as per need with easy upgrade at economical replacement cost. QUALITIES Multi-screen, multi-interface display Particularly backlight button for night operation Fanless intelligent, quiet cooling system ECG, Resp, NIBP, IBP, SpO 2, Temp, AG, CO 2, & ICG possible Anaesthesia Gas module, measures concentration of Fi & ET, CO 2, O 2, N 2 O & ISO, ENF, DES, SEV, HAL APM-700 XL Arrythmia / ST segment analysis

OVERVIEW Global-leading all-in-one module with display and built-in battery Powerful measurement, ergonomic & flexible design Can connect independent large display when multi-display is required OPTIONS Convenient interface control via prompt knob or touchscreen control Massimo SET Pulse Oximetry SunTech Advantage neonatal NIBP technology Fanless cooling-down system, keep the monitor working quietly Parameters with various modules assembled as demand, easy upgrade, save replacement cost Nellcor Pulse Oximetry SpO 2 3-channel thermal recorder 17" 12.1" 17" (12.1" APM-700) full colour anti-glare TFT LCD display 2 GB SD Card, effective storage for historical patient data 4 Module Slots Additional module rack slot: 1 (for module) 6 (4 APM-700) USB ports (peripheral devices interface) Long-life detachable rechargeable lithium battery APM-700

FEATURES Backlight button Prompt Knob Touch Screen (Option) Touchscreen (Option), support of keyboard & mouse operation Available for multilanguage interface Built-in detachable rechargeable lithium battery Particularly backlight button for night operation Abundant Extension Interface Independent physiological & technical alarm SD card socket, effective storage for historical patient data DUAL ALARM LIGHT Hidden Handle SD storage card Lithium Battery Rolling stand Wall mount clinical mounting solutions

central monitoring system The intelligent Central Monitoring System connects all ACENDIS monitors via cable or WiFi and allows to view real-time patient status and data. It can monitor up to 64 patients for safety and reliable decision-making. APM-700 XL APM-700 Multi-screen, multi-interface display Connection to the central monitoring system in a wired or wireless network Each screen can display user defined different parameters, to assure real-time monitoring entire data

display indications Maximum 168 hours graphic & tabular trends Drug dose calculation Short trend Display other bedside monitor s all parameter & one waveform, support user defined parameter display Hemodynamics calculation Other bed The user can select 5 parameters (related waveform will display if available) Clear observation in long distance, especially suitable for ICU, CCU room checking & monitoring during night Display 16 minutes trend of HR, SpO 2, RESP OXYCRG Big font

ADVANCED MODULAR MONITORING ICG Non-invasive method to measure patient s Cardio Output & Hemodynamic status, safe & easy operate Spo 2 Masimo / Nellcor SpO 2 is optional High capacity against interference of ESU, motion & low perfusion AG Anaesthesia Gas module, measures concentration of Et & FiCO 2, O 2, N 2 O and ISO, ENF, DES, SEV, HAL Sidestream / Mainstream / Microstream EtCO 2 is optional Various option can be suitable for intubated patient, ventilation relied patient, non-intubated patient CO 2 2x IBP Max. 8x IBP measurement with waveform, Systolic, Diastolic, Mean Pressure on ART, CVP, ICP, PA, LAP etc to fulfill different positions invasive blood pressure measuring demands Bispectral Index (BIS) measurement uses Aspect Medical technology. It provides depth of consciousness and sedation monitoring for use in the OR, ICU, and other clinical settings. BIS

ACENDIS Emergency mobile server A special feature of the ACENDIS APM-700 / 700 XL is to connect with our Emergency Mobile Server () all-in-one parameter module, which includes the following parameters: ECG (3 or 5 lead), SpO 2, NIBP, Pulse Rate, Temp, Invasive BP (x2), together or in different combinations. Additionally a 12 lead ECG and Nellcor or Masimo SET SpO 2. The also features a 3.5" colour display and backup battery. When the module is disconnected from the docking port on the APM-700 / 700 XL, the patient can continue to be monitored while being transported. EASY TO USE Colourful and clear TFT touch screen with 3.5" display. Gravity Sensor, Visual and sound alarm, large storage capacity, clear parameter and waveform display are helpful to clinical needs MOBILE & EFFECTIVE Small and compact to be carried anywhere. Seamless monitor data recording, plug and play ensure the data transporting from one monitor to another. Perfectly match with all Biolight A-Serial patient monitors. SAFE & SUSTAINABLE Just one single step allows you to unplug and go, helping to reduce error and improve patient safety. is environmental friendly product which is not only safe for people but also for nature environment. Masimo Rainbow SET Pulse CO-Oximetry

CHARACTERISTICS Size & Weight Size : 160 mm x 99 mm x 71 mm Weight: 0.6 kg Display 3.5" Colour TFT-LCD; Resolution: 320 x 240 pixels Waveform: Up to 12 tracks Battery Type: 3.7 V / 1800 mah Rechargeable lithium ion battery Operating time: Up to 60 minutes Charging time: Standby state: Up to 6h Turn off delay: 5 to 10 minutes after the low battery alarm first occurs All-in-one Module OptionS: 1 2 3 4 5 6 7 8 9 10 11 12 2-TEMP RESP NIBP 2-IBP 3/5 Lead ECG 12 Lead ECG Digital SpO 2 Nellcor SpO 2 Masimo SpO 2

TECHNICAL SPECIFICATIONS General Size and Weight Size: 434 mm x 89mm x 206 mm (APM-700 XL) / 422 mm x 362 mm x 213 mm (APM-700) Weight: <11 kg (APM-700 XL) / <9 kg (APM-700) Standard module slot: 4 Additional module rack slot: 1 Power supply Power voltage: AC 100 240V 50 / 60Hz Power input: 150 VA lnput current: 1.7 ~ 0.8 A Safety class: Category I Display 17 / 14.1 (APM-700 XL / APM-700) Colour anti-glare TFT-LCO Resolution: 1280 x 1024 pixels (APM-700 XL) / 1280 x 800 pixels (APM-700) Battery (Option) Type: Rechargeable lithium battery, 11.1 V / 4.0 AH Operating time under the normal use & full charge: 60 minutes (2 batteries for 120 minutes) Recorder (Option) Method: Thermal dot array Paper width: 50 mm (1.97 in) Paper length: 15 m Paper speed: 12.5 / 25 / 50 (mm/sec) Traces: Maximum 3 tracks Recording way: Real-time recording, periodic recording, alarm recording Alarm Level: Low, medium and high lndication: Auditory and visual Patient physiological alarm light color: Yellow & red Equipment technical alarm light color: Blue Supports pitch tone and multi-level volume Supports custom arrhythmia tone Input device Touch button: Standard configuration, support operation of shortcut menu Knob: standard configuration Mouse input: Support Keyboard input: Support System Output & Extensible Interfaces Ethernet network: 2 standard RJ45 socket Defibrillation output: 1 RJ11 socket Nurse call: 1 BNC socket Video output: 1 DVI port, 1 VGA port USB1.1 port: 6 Auxilliary module rack connector: 1 SD memory card: 2G (Standard config) Analog output (ECG or IBP): Option Trend & Reviewing Trend: 168 hours NIBP measurement reviewing: 1000 groups ARR event: 128 groups of ARR event & the associated waveform Alarm events: 128 groups of parameter alarm events & associated parameter Waveform at the alarm moment Holographic waveform: The storage time depends on the stored waveforms & the quantity of them Environment Operating temperature: 0 ~ +40 C Storage temperature: -20 C to +50 C Operating humidity: 15 % to 85 % (non condensing) Storage humidity: 10 % to 93 % (non condensing) Operating atmospheric pressure: 860 hpa to 1060 hpa Storage atmospheric pressure: 500 hpa to 1060 hpa Safety IEC60601-1 Approved, CE marking according to MDD93 / 42 / EEC Performance ECG Lead mode: 3-leads ECG input 5-leads ECG input 12-leads ECG input Lead selection: I, II, III I, II, III, avr, avl, avf, VI- I, II, III, avr, avl, avf, V1 ~ V6 (option) Gain: 2.5 mm/mv ( 0.25), 5 mm/mv ( 0.5), 10 mm/mv ( 1), 20 mm/mv ( 2), 40 mm/mv ( 4), auto CMRR: Monitor 105 db Surgery mode 105 db Diagnostic mode 90 db Frequency response (-3 db): Monitor mode 0.5 ~ 40 Hz Surgery mode 1 ~ 25 Hz Diagnostic mode 0.05 ~ 150 Hz Input impedance : 5.0 Mohm ECG signal range: ±10.0 mv Electrode offset potential: ±500 mv Patient leakage current : <10 ua Standardizing signal: 1 mv ±5 % Baseline recovery: <5 s after defibrillation (mon or surg mode) lndication of electrode separation: Every electrode (exclusive of RL) Protection: Breakdown Valtage 4000 VAC 50 / 60 Hz; defibrillator proof Sweep speed : 12.5 mm/s, 25 mm/s, 50 mm/s HR range: Adult: 10 ~ 300 bpm Pediatric & Neonate: 10 ~ 350 bpm Refreshing time : 50 bpm Per 2 pulses 50 ~ 120bpm Per 4 pulses 120bpm Per 6 pulses Resolution: 1 bpm Accuracy: ±1 % or ±1 bpm, whichever is greater ST segment Measurement range: -2.0 mv ~ 2.0 mv Accuracy: -0.8 amv ~ 0.8 amv, ±0.02 mv or ±10 %, whichever is greater Over ±0.8 mv: unspecified Resolution: 0.01 mv RESP Method: Thoracic impedance Lead selected from: I (RA-LA) or II (RA-LL); Default: I Gain: x0.25, x1, x2, x4 Bandwidth: 0.25 Hz to 2.0 Hz (-3 db) Sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s Measurement range: 0 ~ 150 rpm Resolution: 1 rpm Accuracy: ±2 rpm or 2 %, whichever is greater Delay of apnea alarm: 10 s, 15 s, 25 s, 30 s, 35 s, 40 s, 45 s, 50 s, 55 s, 60 s NIBP Way of measurement: Automatic oscillometry Range of measurement: Adult: SYS 30 ~ 270 mmhg DIA 10 ~ 220 mmhg MAP 20 ~ 235 mmhg Child: SYS 30 ~ 235 mmhg DIA 10 ~ 220 mmhg MAP 20 ~ 225 mmhg Neonate: SYS 30 ~ 135 mmhg DIA 10 ~ 100 mmhg MAP 20 ~ 125 mmhg Cuff pressure range: 0 ~ 300 mmhg Resolution: 1 mmhg Pressure accuracy: Static: ±2 % or ±3 mmhg, whichever is greater Clinical: ±5 mmhg average error Standard deviation: 8 mmhg Unit: mmhg, kpa Measurernent mode: manual, auto, STAT lntervals for AUTO measurement time: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90 minutes; 2, 4, 8, 12 hours STAT mode cycle time: Keep 5 minutes, at 5 seconds interval Overpressure protection: Hardware & software double protections Pulse rate range: 40 ~ 240 bpm ACENDIS - SpO 2 (Digital technic) Measurernent range : 0 ~ 100 % Rresolution: 1 % Accuracy: At 70 ~ 100 %, ±2 % At 0 ~ 69 %, unspecified PR Measurement range: 25 ~ 255 bpm Resolution: 1 bpm Accuracy: ±1 % or ±1 bpm, whichever is greater Nellcor - SpO 2 (Option) Measurement range : 0 % to 100 % Resolution: 1 % Accuracy: At 70 % ~ 100 %: ±2 % (Adult) At 70 % ~ 100 %: ±3 % (Neonate) At 70 % ~ 100 %: ±2 % (Low Perfusion) At 0 % ~ 69 %: ±2 %, unspecified PR Measurernent range: 20 ~ 300 bpm Resolution: 1 bpm Accuracy: 20 bpm to 250 bpm: ±3 bpm 251 bpm to 300 bpm: unspecified Masimo SpO 2 (Option) Measurement range: 0 % to 100 % Resolution: 1 % Accuracy: 70 % to 100 %: ±2 % (adult / pediatric, non-motion conditions) 70 % to 100 %: ±3 % (neonate, nonmotion conditions) 70 % to 100 %: ±3 % (motion conditions) 0 % to 69 %, unspecified Average time: 2-4 s, 4-6 s, 8 s, 10 s, 12 s, 14 s, 16 s PR Measurement range: 25 bpm to 240 bpm Accuracy: ±3 bpm (non-motion conditions) ±5 bpm (motion conditions) Resolution: 1 bpm

TEMP Max channel: 8 Measurement way: Thermal resistance way Measurement range: 0.0 C ~ 50.0 C (32 F ~ 122 F) Accuracy: ±0.1 C or ±1 F (exclusive of probe) Resolution: 0.1 C or 1 F Unit: Celsius ( C), Fahrenheit ( F) Connecting cable: Compatible with YSI-400 serial IBP Max channel: 8 Measurement way: Directly invasive pressure measurement Sensitivity of transducer: 5uV / V / mmhg, ±2 % Impedance of transducer: 300 to 3000 Ω Measurement range: -50 ~ +350 mmhg Resolution: 1 mmhg Unit: mmhg, kpa, cmh2o Accuracy: Static: ±1 mmhg or ±2 %, whichever is greater (exclusive of transducer) ±4 mmhg or ±4 %, whichever is greater (inclusion of transducer) Dynamic: ± 4 mmhg or 4 %, whichever is greater Transducer sites: Arterial Pressure (ART) Pulmonary Artery Pressure (PA) Left Atrium Pressure (LAP) Right Atrium Pressure (RAP) Central Venous Pressure (CVP) lntracranial Pressure (ICP) P1 / P2 Selection of measurement range: ART: 0 ~ +350 mmhg PA: -10 ~ +120 mmhg CVP / RAP / LAP / ICP: -10 ~ +40 mmhg P1 / P2: -50 ~ +350 mmhg EtCO 2 (Sidestream) Measure method: Infrared spectrum Measurement range: 0.0 ~ 13.1 % (0-99.6 mmhg) Resolution: 1 mmhg Unlt: %, mmhg, kpa Accuracy: 0 % to 4.9 %, ±0.3 % (±2.0 mmhg) 5.0 % to 13.1 %, < ±10 % of the reading Measurement range of awrr : 3 ~ 150 rpm Calibration: Offset calibration: Auto, manual, gain calibration EtCO 2 (Mainstream) Measure method: Infrared spectrum Warm up time: Capnogram displayed in less than 15 seconds, at an ambient temperature of 25 C, full specifications within 2 minutes Measurement Range: 0.0 ~ 19.7 % (0 ~ 150 mmhg) Resolution: 1 mmhg Rise time (101 l/min): 60 ms Unit: %, mmhg, kpa CO 2 Accuracy: 0-40 mmhg, ±2 mmhg 41-70 mmhg, ±5 % of readlng 71-100 mmhg, ±8 % of reading 101-150 mmhg, ±10 % of reading (at 760 mmhg, ambient temperature of 35 C) awrr measurement range: 0 ~ 150 rpm awrr measurement accuracy: ±1 rpm EtCO 2 (Microstream) Measure method: Infrared spectrum Warm up time: Capnogram displayed in less than 20 seconds, at an ambient temperature of 25 C, full specifications within 2 minutes Measurement range : 0-19.7 % (0-150 mmhg) Resolution: 1 mmhg Unit: %, mmhg, kpa CO 2 Accuracy: 0-40 mmhg, ±2 mmhg 41-70 mmhg, ±5 % of reading 71-100 mmhg, ±8 % of reading 101-150 mmhg, ±10 % of reading (at 760 mmhg, ambient temperature of 25 C) (when RR >80 rpm, all the AnAesthetic Gas Measure method: Infrared spectrum Fi and Et values: CO 2, N 2 O, O 2, AG (HAL, ISO, ENF, SEV, DES) Resolution: 1 % Unit: % Calibration: Room air calibration performed automatically when changing airway adapter (<5 sec) Warm-up time: <10 s, full accuracy within 1 min Measurement and alarm range of AG Gas Range Accuracy CO 2 0-10 % ±(0.3 % ABS + 4 % REL) N 2 0 0-100 % ±(2 % ABS + 8 % REL) O 2 10-100 % ±(2 % ABS + 2 % REL) HAL, ISO, ENF 0-5 % ±(0.15 % ABS + 10 % REL) SEV 0-8 % ±(0.15 % ABS + 10 % REL) DES 0-18 % ±( 0.15 % ABS + 10 % REL) awrr measurement range: 0 ~ 150 rpm awrr measurement Accuracy: ±1 rpm Rise time (flowing speed 10 l/min): CO 2 90 ms O 2 300 ms N 2 O 300 ms HAL, lso, ENF, SEV, DES 300 ms Total system response time : <1 seconds Noninvasive cardio output (ICG) Method: Measurement of thoracic electrical bioimpedanc Measurement range: HR: 40 ~ 250 bpm SV: 5 ~ 250 ml SI: 5 ~ 125 ml / m2 C.O.: 1.4 ~ 15 L / min TFC: 15 ~ 143 KΩ Accuracy: HR ±2 bpm SV: unspecified C.O.: unspecified Alarm range: C.l.: 0.0 l/min/qm to 15.0 l/min/qm continuously adjustable TFC: 10 / KΩ to 150 / KΩ continuously adjustable Standard configuration of APM-700 XL / APM-700: Mainunit: 17 / 14.1 (APM-700 XL / APM-700) anti-glare TFT-LCD display, 4 standard module slot, 1 additional module rack slot (for all-in-one module), 13 touch buttons (only for APM-700 XL), 2RJ45 enthernet socket, 1 defibrillation output, 1 nurse call socket, 1 DVI port, 1 VGA port, 6 USB 1.1 port, 1 auxiliary module rack connector, 2G SD memory card Option of APM-700 XL / APM-700: module: 8 kinds of option Option module: Sidestream CO 2 module, microstream CO 2 module, mainstream CO 2 module, AG module, ICG module, JBP module, Temp module, SpO 2 module Module rack: Auxillary module rack Navigating: USB compatible mouse and keyboard Printing: 3 channel thermal recorder Mounting: Rolling stand, wall mount Battery: 11.1 V / 4.0 AH rechargeable lithium battery (max 2 pcs) Other options: External display, wireless lan, extensive memory card, analog output (ECG or IBP), touch screen

TURNKEY PROJECTS FINANCIAL CONSULTING MEDICAL PLANNING PROJECT MANAGEMENT PROCUREMENT INSTALLATION TRAINING AFTER-SALES-SERVICE acendis.eu ID: 2016-05-EN-APM-700+CMS AC acendis.eu Technical changes and printing errors reserved. ACENDIS Wohlenbergstr. 5 30179 Hannover GERMANY Tel. +49 511-1 83 83 Fax +49 511-71 77 29 contact@acendis.eu www.acendis.eu