Dim levels for each system output may be controlled by either of the following methods:

Similar documents
Dim levels for each system output may be controlled by any of the following methods:

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

User Manual. JS-ICON 624 PACK Portable Dimmer Pack. JOHNSON SYSTEMS INC. Spring

Models DMX12DIM ELV Installation and Operations Manual

Junos WebApp Secure 5.0 Hardware Guide

Model DMX24DIM Installation and Operations Manual

OWNER'S MANUAL DIMMERMASTER 1224 DIGITAL DIMMER

SAVE THESE INSTRUCTIONS

User Manual Charter Street Los Angeles CA

Dell SC460 Expansion Enclosure Getting Started Guide

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

L1.2 & L2.2. LED Studio Light OPERATING INSTRUCTIONS

NSI DIGITAL DIMMING SYSTEM DDS 5300 / 5600 DIMMER PACK

1. Unpacking the System

SCv360 Expansion Enclosure

Wireless DMX Control. Show Performer DMX Controller. Stage Desk 48 DMX Controller

NI PXIe-1062Q Power Supply Shuttle

ETC Installation Guide

Overview. Features CHAPTER

SYSTEMS INC.

Installation and User Guide

Digital Lighting Systems, Inc.

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

USER MANUAL Table of Contents

XC-42 OWNERS MANUAL COMPACT PORTABLE DIMMER. Revision /12/2007. Lightronics Inc. 509 Central Drive Virginia Beach, VA

USER MANUAL Table of Contents

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm

E-Series Site Preparation Guide

Installation and Maintenance

ANYtronics smartdim. 12 Channel Dimming System

Dell MD1280 Storage Enclosure Getting Started Guide

Model DMX8DIM Installation and Operations Manual

Control different load types with one device

DOUG FLEENOR DESIGN. Model: NODE Ethernet to DMX512 Gateway OWNER'S MANUAL

HomePro ZRF113. Z-Wave Radio Frequency (RF) Controlled, 120 VAC, Isolated Contact Fixture Module, Series 200, Release 2.2

CODE ELECTRONIC CO., LTD.

DS232. RS232 to DMX Converter V4. ELM Video Technology s RS232 to DMX Converter / Controller

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

DEB 575/1200. Electronic Flicker Free Ballast DMX MOD INSTRUCTION AND MAINTENANCE MANUAL

2200 Series. Quick Start Guide SAFETY CHECKLIST. Safety Made Simple

A Creative Light & Sound Company

HPE BladeSystem c3000 Enclosure Quick Setup Instructions

Compact controller for single room solutions

Digital Lighting Systems, Inc.

iconverter 2-Module Power Chassis

V2 LED SOFTLIGHT USER GUIDE

SNAP Lighting Control Panel

AB0602D ARCHITECTURAL BALLAST DRIVER. Version Date 06/25/2012

UCL & Color Logic. 4.0 LEDs. Installation Guide. LxCUSxxxxx, SP05xxLEDxxx & SP05xxSLEDxxx. Universal ColorLogic ColorLogic. 4.

INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.0.5

A Creative Light & Sound Company

For Models #2384W/I (and Slave Remote Dimmer Model #1135W/I)

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

DEB 1.2k/2.5k. Electronic Flicker Free Ballast MOD INSTRUCTION AND MAINTENANCE MANUAL

VersaLamp High Bay/Light Fixture Installation Instructions

EMC COMPLIANCE EN AS/NZS 1044 EN AS/NZS EN AS/NZS

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

4 Port DVI VGA Dual Monitor KVM Switch USB with Audio & USB 2.0 Hub

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

User's Manual: A LD360 DMX LD360 DMX HP. Rev. 1.0 Software Version 1.0 1/17/95

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

ETC Installation Guide

1.2 Intel Server Chassis SC5400BASE Summary

Switched Relay Controller - Relay Panel with Breakers

2 Port DVI VGA Dual Monitor KVM Switch USB with Audio & USB 2.0 Hub

dynamic white par manual

Power Supply and Fan Module Installation

Cisco CRS 16-Slot Chassis Power Systems

Artistic Licence. Rail-Switch II. User Guide. Rail-Switch II User Guide. Version 5-5

TOURING DIMMING & DISTRIBUTION SYSTEM OPERATOR MANUAL

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

Numerics INDEX. 10/100/1000 ports cable lengths 2-4, B-6 connecting to 2-38, B-43 described /100 ports

4 Port Dual DVI USB KVM Switch with Audio & USB 2.0 Hub

RGBW Mini Moving Head Stage Spot Light Model: SSL1. User Manual.

Rack Mount Power Supplies

Light Source User Guide

RMD-1220 Rack Mount Dimmer-12Channel

PEM Faults and Blower Failures

ADDENDUM FOR 20, 27, & 28 OPTIONS

Illuminator User Guide

2-port KVM Switch with Dual VGA - USB 2.0

Control Solutions. for Creative Professionals

PLC Racks IC697CHS782/783

CS XL XM. EcoSystem Bus Supply

Table of Contents Quick Install Guide page Introduction Safety Rack System Precautions ESD Precautions...

VRp Three-Phase Precision AC Voltage Regulator

PACSystems RX7i IC698CHS009/119

Precision DMX Manual

Operating Instruction Manual POWERED MIXER. Model MX-401. Toa Electric Co., Ltd. KOBE, JAPAN

(Hardware and case keys are provided inside the chassis storage compartment.)

4 Port DVI VGA Dual Monitor KVM Switch USB with Audio & USB 2.0 Hub

Strand Lighting Specification

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

A double yoke enables the fixture to be operated in several positions.

HomeWorks Remote Power Feed-Through Panels

ColorLogic 4.0 Installation Guide

Installation and Operation

Transcription:

Applied Electronics Bravo Series Dimming System Model SA12/1200 Setup and Operation Instructions 1.0 Scope This document details the setup and operation requirements for Applied Electronics Bravo Series Dimming System. These Instructions are provided for the Model SA12/1200 rack mount dimmer unit. 2.0 General Applied Electronics Bravo Series Dimming System consists of a 2 space rack mountable chassis with user interface on the front panel (see Figure 1). The SA12/1200 provides the capability to control and dim twelve 1200 watt outputs. Dim levels for each system output may be controlled by either of the following methods: 1. Any DMX512-compatible lighting console. 2. Local control assumed from the front panel of the SA12/1200. Internal temperatures are continuously monitored in each unit. If an over temperature condition is sensed, all outputs within that unit are turned off until the system is reset. The SA12/1200 Bravo Series Dimmer is available with an assortment of output connections. Output types include: Edison, dual stagepin, multipin (Soco), terminal block and patch bay insulted tip-jack (see figure 2). Each Dimmer is user defined at date of purchase. The front panel of the SA12/1200 has a five digit, 7-segment display for system status, a valid DMX LED for control signal status and pushbutton controls for easy set-up of system parameters. Each SA12/1200 is provided with a standard one-year warranty for parts and labor.

2 Figure 1 SA12/1200 (front view)

3 Multipin (Soco) Output Patch Bay Insulated Tip-Jack Output Stagepin Output Terminal Block Output Edison Output Figure 2 SA12/1200 Rear Views

4 3.0 Specifications - Input Voltage: 220VAC (120VAC x 2) or 208VAC (3-phase) - Input Current: 120A per panel, supplied as 60A x 2 (for single phase sources) or 40A x 3 (for 3-phase sources) - Dimming Outputs: 12 channels @ 2400W - Weight: 36 lbs. - Outside Dimensions: 3.47 high x 19 wide x 17.5 deep - Operational Ambient Temperature: 32 o to 104 o F (0 o to 40 o C) 4.0 Chassis Mounting Each SA12/1200 dimmer unit is intended to be mounted in a standard 19 rack enclosure. Note that all dimmers are inherently noisy devices, and care should be taken not to mount the panels in a location where audible noise could be a distraction. For cooling considerations an exhaust fan for the SA12/1200 is located on the left side (looking at the front of the unit). The right side of the dimmer has an intake fan. When mounted in a rack enclosure insure proper venting of each unit is allowed by having 2 diameter min. vent holes in rack side panel adjacent to the exhaust vent of the SA12/1200. *Allow 6 minimum clearance between racks if two or more racks are to be located side-by-side Rear rack mounting rails are recommended for rear support of each dimmer unit. Rear mounting ears are available for the SA12/1200 which will allow the unit to be secured to the rear mounting rails. 5.0 System Wiring Details The following sections detail control and power wiring requirements for the SA12/1200 Dimmer Unit. 5.1 Power Input Connections for the SA12/1200 Bravo Series Dimmer The SA12/1200 Dimmer Unit may be configured for use with 3-phase or singlephase power sources. Your dimmer unit is normally shipped configured for three phase operation. In 3-phase mode, all blue wires marked with black and red tape should be connected to TB1 position 3 (second from right from front of unit). In single-phase configuration, all blue wires with black marking tape should be connected to TB3 position 1 (with other existing black wires) and blue wires with

5 red marking tape should be connected to TB1 position 2 (with other existing red wires). The resulting phase/channel assignments for each configuration are as follows: Configuration Channel Phase Assignment 1 2 3 4 5 6 7 8 9 10 11 12 3-Phase A B C A B C A B C A B C Single Phase A B B A B A A B B A B A WARNING VERIFY THAT NO INPUT POWER IS BEING PROVIDED TO THE CHASSIS PRIOR TO MAKING THE FOLLOWING CONNECTIONS. System power input connections should be made in accordance with Figure 3 and as detailed below. Neutral Figure 3 Power Input Connections Phase C Phase B TB1 Phase A Ground

6 Ground Connection Earth ground input should be connected to the.ground lug located next to the power input terminal block. Neutral Connection Power Neutral input should be connected to TB1 position 4. Phase A Connection Connect one phase of system power (hot) to TB1 position 1. Phase B Connection Connect a second phase of system power (hot) to TB1 position 2. Phase C Connection In 3-phase power systems, connect the third phase of system power (hot) to TB1 position 3. No connection required for single phase operation. 5.1 SA12/1200 Control I/O Connections The SA12/1200 Bravo Series dimmer is controlled by industry standard (USITT), five pin DMX-512 control protocol. A standard five pin XLR connector is provided along with a DMX output (loop-thru) connector. WARNING VERIFY THAT NO INPUT POWER IS BEING PROVIDED TO THE CHASSIS PRIOR TO MAKING THE FOLLOWING CONNECTIONS. DMX Input Connect any DMX512-compatible lighting console to the sidemounted 5-pin XLR connector using a standard DMX cable. 5.3 Power Output Connections for SA12/1200 Bravo Series Dimmer System power output connections should be made in accordance as detailed below. Hot Connections Depending on the output connection type purchased, Hot wires for each output channel should be connected to the corresponding position on the rear panel as specified below (see figure 2).

7 Stagepin Output: Channel assignments for the dual stagepin dimmer runs from right to left (looking at the rear of the dimmer unit), i.e. channel one is the furthest stagepin to the right channel twelve is the furthest stagepin to the left. Edison Output: One Edison output (twelve total) is provided per channel and the outputs are right to left with channel one the furthest Edison right - top, channel two Edison is directly underneath channel one and are consistently wired across right to left in the same manner. Terminal Block Output: The rear mounted terminal block provides a channel (hot) connection and a neutral connection for each channel output. Channel one is the terminal position to the furthest right and all other terminals are wired in sequence right to left. Multipin (Soco) Output: Two multipin (Soco) output connectors are provided each wired for six circuits apiece. There is one outputs provided per channel. The multipin connectors are wired to industry standard pin outs. Patch Bay Insulated Tip-Jack Output: The patch bay version of the SA12/1200 Bravo Series dimmer is wired left to right whereas channel one is the furthest column of jacks to the left and channel twelve is the furthest column of jacks to the right. Each output channel is labeled and color coded to correspond to phases being used. Three output jacks are provided per channel to allow for maximum flexibility. This dimmer is the base unit of the Omega Touring System. More than one lighting fixture may be connected to each output channel, as long as each channel s load does not exceed 1200 watts. 6.0 System Setup After all system control and power wiring are connected as detailed in section 5 above, turn all 12 output channel circuit breakers OFF, turn your DMX-512 lighting console OFF and energize the system.

8 The system front panel will display the base DMX address (address 001 is the default). Turn ON your DMX console and the Valid DMX LED should be illuminated. Figure 4 Front Panel Controls 6.1 DMX Address Adjustment The DMX Address pushbutton (see figure 4) allows you to set the base address of the SA12/1200. The base address is physical channel one on the dimmer unit. All other DMX channels are sequential up to channel twelve. To adjust the DMX base address, press the DMX Address pushbutton. The Valid DMX LED will extinguish, and the three 7-segment displays digits will flash. While flashing press the Up or Down arrow pushbutton as desired to achieve the starting address required. When the desired address is visible, press the DMX Address pushbutton again, the digits will stop flashing, the base DMX address is set and the Valid DMX indicator LED will illuminate. The dimmer is now ready for use. This setting is permanently stored in Flash memory so it will not be lost even when dimmer is powered off.

9 6.2 Dim/Switch Adjustment The SA12/1200 Bravo Series dimmer allows you to adjust each channel independently for either normal dimmer mode or non-dimming switch mode (also called relay mode). To adjust the output mode of individual dimmer channels press the Dim/Switch pushbutton (see figure 4). The display will flash including the two digit channel number display. The Valid DMX LED will turn off (because you are in local control). To select which channel to change to Switch Mode, press the Channel Select pushbutton until the desired channel is displayed. The current setting for the selected channel will show d for dimmer mode or S for switch mode. Press the Up or Down arrow pushbutton as desired to achieve the desired setting for the channel. To change the setting for another channel repeat these steps until all channels are set to the desired function. When finished, press the Dim/Switch pushbutton again and the dimmer will return to DMX control. The digits will stop flashing, the Valid DMX LED will illuminate. These settings will be permanently store in Flash memory so it will not be lost even when the dimmer is powered off. 6.3 Level Adjust The SA12/1200 Bravo Series Dimmer allows you to take control from DMX and set up a static scene from the front of the dimmer or manually test each channel independently without the use of a DMX controller. To manually take control of the output, press the Level Adjust pushbutton (see figure 4). The display will flash including the two digit channel number display. The Valid DMX LED will turn off (because you are in now in local control). The display will show channel 01 and the current level displayed will be 000. Press the Channel Select button again until the desired channel is shown. Press the Up or Down arrow keys to change the output level of the selected channel. The display will show the output in percentage value (0 100%). Repeat this process for as many channels as desired to set up a static scene. To change out of local control, press the Level Adjust pushbutton, the dimmer will return to DMX control. The digits will stop flashing and the Valid DMX LED will illuminate.