Brief instructions Illumination unit O3M950 O3M /00 03/2016

Similar documents
Brief instructions Illumination unit O3M /00 09/2014

Brief instructions Mobile 3D sensor O3M150 O3M151 O3M160 O3M /00 03/2016

Quick reference guide 3D sensor O3D3xx

Installation instructions Ethernet switch EC / / 2011

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions RFID evaluation unit DTE / / 2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions. Speed monitor D / / 2014

Operating instructions Optical distance sensor. OID20x / / 2014

Installation Guide. O2Vxxx / / 2015

Operating instructions Multicode Reader. O2I10x / / 2010

Operating instructions Optical distance sensor. OID20x / / 2015

Operating instructions Multicode Reader. O2I10x O2I30x / / 2015

Installation instructions RF-identification system with integrated AS-i slave DTSLF / / 2010

Installation Guide. O2Ixxx / / 2015

Operating instructions Optical distance sensor. OID25x / / 2015

Installation instructions Inclination sensor EC2019 EC / / 2013

Brief instructions Starter set BasicController BasicRelay BasicDisplay EC / / 2011

Operating instructions Optical distance sensor. OID25x / / 2014

Original operating instructions Photoelectric safety sensors (safety light grid) with active / passive system OY90xS

Operating instructions Diagnostic electronics for vibration sensors VSE002 / VXE002 / VXE003 VYE001 / VYE002 / VYE003 / VYE /01 05/2015

Operating instructions Optical distance sensor O1D / / 2012

Content. Sontheim Industrie Elektronik GmbH Page 2 of 15 07/2016 Installation instructions Version 1.2

OT EASY 60 II. LED control unit Operating instructions

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Operating instructions Optical distance sensor O1D / / 2008

Operating instructions Optical distance sensor. O5D15x / / 2014

Software Manual ifm Vision Assistant for 3D camera O3X1xx

Operating instructions. Standstill monitor A / / 2011

Operating instructions Object recognition sensor. O2D22x / / 2008

Operating instructions RFID evaluation unit DTE / / 2011

Operating instructions IO-Link master CabinetLine AL19xx

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Installation and Setup guide VARIO Series

Original operating instructions Safety relay with relay outputs G1501S / / 2016

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

NO: PH-185 PRODUCT: E3JK Photoelectric Sensors DATE: May 2014 TYPE: Discontinuation Notice

Light Control SLS ADRIA

New! 3D Smart Sensor your assistant on mobile machines. ifm.com/us/mobile

BW-108. Building Wash BW-108. User Guide. Advanced LED Technology

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Operating instructions Vortex flow meter. SVxxx / / 2015

INSTRUCTION MANUAL. * Design and Specifications are subject to change without notice. ver. 1.0 PRINTED IN KOREA

Original operating instructions Fail-safe inductive sensor GI712S

Original operating instructions Fail-safe inductive sensor GG711S

Series 3700 Screw Terminal Assemblies Installation Instructions

Operating instructions Encoder PerformanceLine. RxP5xx /00 04/2018

PLCMTR Commercial Grade Camera System

Connecting a Cisco Input Module

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

MC 11 EB-2 Power supply cabinet with external bus, AC version

Operating instructions Evaluation system for flow sensors VS / / 2013

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

ColourChaser Touch. Installation Guide

SUBCON-PLUS-PROFIB...

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

Universal Safety Photo Eye UL MONITORED DEVICE

Original operating instructions. Fail-safe SmartPLC with Profinet slave interface AC402S /00 06/2016

DAQ-System for DynoWare

HD40H(X) Performance Series Camera. User Guide

Operating Instructions

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

Quick Setup Instructions. VARIO2 IPPoE Series. Box Contents: Accessories (optional):

SENSORS S3Z. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Device manual Inclination sensor 2 axes JN /00 04/2015

- ELV OVERVIEW. InstallationGuide SUPPLIED PARTS RELATED PARTS. Brackets Fixtures. Other. 1 of 9 IG-STR9-ELV

Connecting a Cisco Output Module

Overview of the Cisco Wireless Gateway for LoRaWAN

Camera systems for mobile machines.

Scanner 2000 Steam Mass Flow Transmitter

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

GS202 Encoder Switch

Operating instructions Pressure sensor. PN50xx / / 2010

basicdim Wireless Wireless module for basicdim

Datasheet - CSS 11-30S-D-M-ST

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

panasonic.net/id/pidsx/global CCD The sensor can be used for various applications with its binary data output with four different sensing modes.

onlinecomponents.com

Operating instructions. Monitor FD / / 2013

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Installation Instructions

KEZ-c2TR28V12XIR HD-TVI 1080p Varifocal IP66 Super Beam IR True WDR Turret Cameras with OSD, CVBS Output and UTC Control

Operating instructions Programming and display unit PP / / 2010

Quick Start. i16 w16 i8 w8 i6 i4 w4 i2 w2. 25W max. 42W max. Input 24V AC/DC 12/24V AC/DC 12/24V AC/DC 12/24V AC/DC

BK MIKRO 5-RL. Tool Monitoring System for Paired Scanning Applications. Operating Instructions Issue 2.01 dated

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Manual Version: V1.00. Video Decoder Quick Guide

C9900-P208 and C9900-P209

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

Operating instructions. Monitor FR-1 / FR-1N / / 2013

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

FC-29W 9 UN-UNIVERSAL Dome Housing. Installation Instructions

B-33. Hardware and Install Manual. (DC 12V / PoE)

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Installing the Cisco SFS 3504 Server Switch

The third dimension at a glance. Visual assessment of distance, level or volume. The new 3D vision sensor.

TXM1.8RB. TX-I/O Blinds module

Online data sheet WL9LG-3P2232 W9LG-3 SMALL PHOTOELECTRIC SENSORS

Transcription:

Brief instructions Illumination unit O3M950 O3M960 80236594/00 03/2016

Content 1 About these instructions........................................... 4 1.1 Symbols used............................................... 4 1.2 Warnings used.............................................. 4 2 Safety instructions............................................... 4 2.1 Safety note................................................. 5 3 Functions and features............................................ 6 4 Items supplied................................................... 6 5 Accessories..................................................... 6 6 Installation...................................................... 7 6.1 Mounting accessory.......................................... 8 7 Electrical connection.............................................. 8 7.1 Wiring O3M950 illumination unit................................. 9 8 Set-up........................................................ 10 8.1 Put the sensor into operation.................................. 10 9 Approvals/standards............................................. 10 10 Note on the software............................................ 10 2

Licences and trademarks Microsoft, Windows, Windows XP and Windows Vista are registered trademarks of Microsoft Corporation. Adobe and Acrobat are registered trademarks of Adobe Systems Inc. All trademarks and company names are subject to the copyright of the respective companies. 3

1 About these instructions This document is intended for specialists. These specialists are people who are qualified by their appropriate training and their experience to see risks and to avoid possible hazards that may be caused during operation or maintenance of the device. The document contains information about the correct handling of the device. Read this document before use to familiarise yourself with operating conditions, installation and operation. Keep this document during the entire duration of use of the device. For a detailed description of the device please read the operating instructions and the programming manual. 1.1 Symbols used Instructions > Reaction, result [ ] Designation of keys, buttons or indications Cross-reference Important note Non-compliance may result in malfunction or interference. Information Supplementary note 1.2 Warnings used CAUTION Warning of personal injury. Slight reversible injuries may result. 2 Safety instructions These instructions are part of the device. They contain texts and figures concerning the correct handling of the device and must be read before installation or use. Note the safety instructions. Use the device as intended. The installation and connection must comply with the applicable national and international standards. Responsibility lies with the person installing the unit. Only the signals indicated in the technical data or on the device label may be supplied to the connections or wires. 4

CAUTION Invisible infrared light The illumination unit emits infrared light of risk group 1 (IEC 62471:2006) invisible to the human eye. The infrared light can cause damage to the retina. Use the illumination unit with the described devices and settings. Avoid staring into the infrared beam. Observe the safety note ( 2.1). 2.1 Safety note NOTICE IR light emitted from this product. Classification acc. CEI/IEC 62471:2006 Risk Group 1 5

3 Functions and features The illumination unit illuminates a scene using infrared light. A sensor processes the infrared light reflected by the surfaces. The illumination unit may be used as a component of a photoelectric system only with the following devices: O3M150 Mobile 3D Sensor O3M160 Mobile 3D Sensor O3M151 Smart Sensor O3M161 Smart Sensor 4 Items supplied O3M950 / O3M960 illumination unit Brief instructions The illumination unit is supplied without sensor, installation and connection accessories and software. 5 Accessories The following accessories are needed for the operation of the illumination unit: Description Mobile 3D sensor or Smart sensor MCI connection cable between sensor and illumination unit Power supply cable for illumination unit Article no. O3M150 / O3M160 O3M151 / O3M161 E3M121 (alternatives: E3M122, E3M123) E3M131 (alternatives: E3M132, E3M133) You can find more information about the accessories at www.ifm.com Data sheet search e.g. O3M950 Accessories 6

6 Installation The sensor is operated as a system together with the illumination unit. During installation note the following: Operate sensor and illumination unit in combination. Install sensor and illumination unit between 0 and 2.80 m apart. > > Select the matching MCI connection cable depending on the distance. Keep the area illuminated by the illumination unit free from any obstructions in a close range (up to 50 cm). Use cables with strain relief. Sensor Illumination unit Sensor Illumination unit 7

6.1 Mounting accessory Depending on the intended location and type of mounting the following mounting accessories are available: Description Mounting set U-shaped (U-shaped fixture, adjustable for types O3Mxxx) Mounting set for rod mounting Ø 14 mm (clamp and bracket for types O3Mxxx) Mounting rod straight Ø 14 mm, length 130 mm, M12 Rod, angled Ø 14 mm, length 200 mm, M12 Article no. E3M100 E3M103 E20939 E20941 You can find more information about the accessories at www.ifm.com Data sheet search e.g. O3M950 Accessories 7 Electrical connection NOTE The unit must be connected by a qualified electrician. Device of protection class III (PC III) The electric supply must only be made via PELV circuits. Switch off the power supply before electrical connection. NOTE The IP rating given in the data sheet is only guaranteed if the M12 connectors are firmly screwed. The unit can be damaged by insufficiently tightened M12 connectors. Firmly screw the M12 connectors to the unit. 8

Sensor Ethernet Ethernet PC CAN-Bus 9-32 V DC USB MCI USB CANfox Illumination unit MCI CAN-Bus 9-32 V DC 12/24 V DC / 75 VA Power supply 7.1 Wiring illumination unit (1) MCI - Modulation and communication interface Connection sensor - illumination unit Only use original ifm cables E3M121, E3M122 or E3M123. (2) Power supply M12 connector, A-coded, 4 poles 1 GND 2 9..32 V 3 9..32 V 4 GND Before wiring note the following: Use all 4 wires of the M12 connector for the power supply. Unnecessarily long cables cause an additional voltage drop. For the power supply keep the cable short. Up to 14 A may flow via the cable for the power supply. Ensure a sufficiently dimensioned core cross-section. Use original ifm cables E3M131, E3M132 or E3M133. 9

8 Set-up 8.1 Put the sensor into operation To put the sensor into operation follow the instructions below. 1. Switch off the power supply. 2. Use MCI cable to connect sensor and illumination unit. 3. Connect sensor with Ethernet cable. 4. Connect the sensor with the sensor cable for CAN bus and power supply. > > The sensor cable connects the power supply and CAN with the sensor. 5. Connect illumination unit with power supply. 6. Connect CANfox USB interface with PC via USB and with CAN via adapter cable. 7. Establish power supply. During the first set-up the sensor connects with the illumination unit. Connection may take up to 60 s. 9 Approvals/standards The CE Declaration of Conformity is available on our website. Alternativ steht die CE-Konformitätserklärung auch im Internet zur Verfügung. www.ifm.com Datenblatt-Suche z.b. O3M Zulassungen 10 Note on the software This unit contains (maybe modified) Open Source software which is subject to special licensing terms. For copyright information and licensing terms please refer to: www.ifm.com/int/gnu For software subject to the GNU General Public License or the GNU Lesser General Public License the source code can be requested against payment of the copying and shipping costs. 10

11