SIMATIC. Component based Automation - WinLC PN Addendum to WinAC Basis V3.0. Foreword. Introduction to CBA and WinAC PN 2. Routing with WinLC PN 3

Similar documents
Siemens Distributor SIMATIC. Component based Automation Creating PROFInet Components

SIMATIC NET for SIMOTION

SIMATIC. Windows Logic Controller (WinLC) Preface, Contents. Product Overview 1. Setting Up WinLC Software 2

SIMATIC. Windows Automation Center. WinAC Basis. Overview. Preface. Product Overview 1. Installing the Components of. WinAC Basis

SIMATIC. PDM V5.2 The Process Device Manager. Preface, Contents. Product Introduction 1. Starting SIMATIC PDM 2 Configuring Networks and Devices 3

Aotewell SIMATIC S7-PDIAG for S7-300 and S Configuring Process Diagnostic Getting St

SIMATIC Easy Motion Control. Getting Started Edition 02/2003. First Steps in Commissioning

AUA Wrapper for Simatic Logon Service

Siemens SIMATIC. Windows Automation Center WinAC Pro. Preface, Contents Product Overview and Installation. Getting Started 2.

SIMATIC. Process Control System PCS 7 Operator Station. Preface, Contents. The PCS 7 OS 1 Introduction to PCS 7 OS Configuration

SIMATIC. Windows Automation Center WinAC Basis V4.1. User Manual. Version: 05/2004 A5E Siemens Automation

SIMATIC Automation License Manager Manual 02/2008 A5E

Siemens Distributor SIMATIC. WinAC MP for MP370 V3.1. Preface, Contents. Product Overview. Transferring WinAC MP to the Multi Panel

SIMATIC. Component Based Automation SIMATIC imap STEP 7 AddOn Creating PROFINET components. Preface. Creating PROFINET components in STEP 7

SIMATIC. Windows Logic Controller WinLC RTX 3.1. Preface, Contents. Product Overview 1. Setting Up the WinLC RTX Software

SIMATIC. Windows Automation Center RTX WinAC RTX V4.0. User Manual A5E

SIMATIC. TeleService for S7, C7, and M7 Remote Maintenance for Automation Systems. Preface, Contents. Introducing TeleService

SIMATIC. TeleService V6.0 Service Software for SIMATIC S7 and C7. Preface, Contents. TeleService Introduces Itself. Installing Software and Hardware 2

SIMATIC PC. Panel PC Industrial Lite Without Operating System. Preface, Table of Contents

Siemens Drives & PLCs

SIMATIC. Communications processor CP 340 first commissioning steps. Getting Started 04/2005 A5E

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC PC. Panel PC 577 Installation Using the Docu & Drivers CD 10/2005. Preface, Table of Contents. Introduction 1.

Siemens Spares SIMATIC. Process Control System PCS 7 Communication Blocks Contents. Communication blocks 1 Index.

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Commissioning PC Stations - Manual. and Quick Start SIMATIC NET. PC software Commissioning PC Stations - Manual and Quick Start.

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

SIMATIC NET. S7-CPs for PROFIBUS Configuring and Commissioning

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

SIMOTION. SIMOTION SCOUT Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler. Function Manual 05/2009

Programming Interface Description of the Functions

SIMATIC. Automation system BRAUMAT/SISTARClassic V5.3 Block library basic. Preface, Content. Blocks in SIS_USR. Appendix. Manual

Configuration limits for products of the SIMATIC NET PC Software V8.1 SIMATIC NET

SIMATIC. Process Control System PCS 7 Help for SIMATIC PDM (V8.1 SP1) Preface 1. Using SIMATIC PDM 2. Installation 3. PDM Exportfile Converter 4

Readme SiVArc V14 SP1 Update 6

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

SIMATIC. Industrial software WinAC RTX F Introduction 1. Selecting suitable hardware 2. Installing/removing the WinAC RTX F 2009 software

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2

SIMOCODE pro. Read me SIMOCODE ES. Introduction 1. Installation notes 2. Installation/License key/ Uninstallation 3.

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E

Configuration limits for products of the HARDNET-PB DP-Base 1

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

SIMATIC. PCS 7/505 OS Setup Guide for V6.1. Preface, Contents. Introduction 1. Install the Software. Update a project from V6.0 to V6.

SIMATIC. Windows Automation Center RTX WinAC RTX Introduction 1. Product overview 2. Installation 3. Getting started 4

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

SIMATIC. Process Control System PCS 7. Preface, Contents. Basics of PCS 7. Plant Description. Creating a Project. Configuring Hardware

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

SIMATIC. Process Control System PCS 7 Help for SIMATIC PDM (V8.0.2) Preface 1. Using SIMATIC PDM 2. Installation 3. PDM Exportfile Converter 4

SIMATIC. Process Control System PCS 7 PC Configuration and Authorization A B C. Preface, Contents PC Components of a PCS 7 Plant 1

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

SIMATIC. Configuring Hardware and Communication Connections STEP 7 V5.2. Preface, Contents Basics of Configuring Hardware with STEP 7

SIMATIC HMI. Configuring Graphics Displays. Product Brief. Edition 12/01. Table of Contents. Introduction. Commissioning Operating Units

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

S7-300 Programmable Controller

SIMATIC. Process Control System PCS 7 Getting Started Part 1. Preface, Contents. Requirements for Getting Started 1.

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

SITOP UPS1600 under STEP 7 V5. SITOP UPS1600 under STEP 7 V5. Introduction. Safety notes. Description 3. Assigning the IP address

Contents, Foreword. Basic software SIMATIC D7-SYS CFC. STEP 7 option packages for D7-SYS SFC. Index. Manual. Edition

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

B.Data V6.0 Installation SIMATIC. B.Data V6.0 Installation. Introduction. Installing B.Data. Setting up B.Data Web 3

SIMATIC. Process Control System PCS 7 V7.0 SP1 Software Update With Utilization of New Functions (PCS 7 V6.x to V7.0 SP1) Preface.

SIMATIC. SIMATIC Logon V User management and electronic signatures 1. Hardware and Software Requirements 2. Scope of delivery 3.

SIMATIC Process Control System PCS 7 PC Configuration and Authorization Manual Appendices Edition 04/2004 A5E

Block Library Motor Starter SIRIUS for SIMATIC PCS 7

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

SIMATIC. Function modules FM 351 First Steps in Commissioning. Purpose of the Getting Started. Requirements 2

SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Functions 1. Software installation 2. Operation. Configuration Manual

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SIMATIC. WinCC Readme Runtime Professional. Validity 1. Improvements in Update 7 2. Improvements in Update 6 3. Improvements in Update 5 4

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

SIMATIC. Process Control System PCS 7 Help for SIMATIC PDM (V9.1) Security information 1. Preface 2. Using SIMATIC PDM 3.

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

Cycle and response times SIMATIC. S Cycle and response times. Preface. Documentation guide. Program processing 2. Cyclic program processing 3

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

SINAUT ST7. SINAUT ST7cc Control Center A I. Manual. Introduction to ST7cc. Installation. Preparation. Working with ST7cc Config

Software Kit. Automatic Door Controls. SIDOOR Software Kit. Introduction 1. General safety instructions. Installation. Uninstalling the software 4

B.Data V6.0 SP1 Installation SIMATIC. B.Data V6.0 SP1 Installation. Introduction 1. Installing B.Data. Setting up B.Data Web

PROFIsafe SITRANS. Pressure transmitter SITRANS P, DS III PROFIsafe series. Product Information 7MF4*34 04/2008 A5E

SIMATIC. PROFINET System Description. Preface. Guide to the PROFINET Documentation. PROFINET overview 2. Setting Up PROFINET 3

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect - Client. Preface. Requirements for operation 1

SIMATIC PC. Panel PC 677 and PC 877 Installation Using the Docu & Drivers CD 04/2005. Preface, Table of Contents. Introduction 1.

Preface 1. Device Management System 2. Contact Information 3. User Manual Device Management System. English. Release

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

SIMATIC HMI. WinCC V7.4 WinCC/Options for Process Control. Overview of process control system options 1. OS Project Editor 2.

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

MCIS DNC Cell/Plant SINUMERIK. Motion Control Information System MCIS DNC Cell/Plant. Introduction 1. Prerequisite. Installation 3.

Preface Master Data System Contact Information SIPLUS CMS

SIMATIC. Process Control System PCS 7 SIMATIC BATCH. Preface, Contents Introducing the Product and Installation

Siemens Drives & PLCs

SIMOTION. Motion Control Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler 4.

ST (6ES7132-6FD00-0BB1)

Transcription:

SIMATIC Component based Automation - WinLC PN Addendum to WinAC Basis V3.0 Manual Foreword 1 Introduction to CBA and WinAC PN 2 Routing with WinLC PN 3 Installing WinLC PN 4 Commissioning WinLC PN 5 Notes on Using WinLC PN 6 Technical Data for WinLC PN 7 Index Edition 07/2001 A5E00097465-01

Safety Guidelines This manual contains notices intended to ensure personal safety, as well as to protect the products and connected equipment against damage. These notices are highlighted by the symbols shown below and graded according to severity by the following texts:!!! Danger indicates that death, severe personal injury or substantial property damage will result if proper precautions are not taken. Warning indicates that death, severe personal injury or substantial property damage can result if proper precautions are not taken. Caution indicates that minor personal injury can result if proper precautions are not taken. Caution indicates that property damage can result if proper precautions are not taken. Notice draws your attention to particularly important information on the product, handling the product, or to a particular part of the documentation. Qualified Personnel Only qualified personnel should be allowed to install and work on this equipment. Qualified persons are defined as persons who are authorized to commission, to ground and to tag circuits, equipment, and systems in accordance with established safety practices and standards. Correct Usage Note the following:! Warning This device and its components may only be used for the applications described in the catalog or the technical description, and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. This product can only function correctly and safely if it is transported, stored, set up, and installed correctly, and operated and maintained as recommended. Trademarks SIMATIC, SIMATIC HMI and SIMATIC NET are registered trademarks of SIEMENS AG. Third parties using for their own purposes any other names in this document which refer to trademarks might infringe upon the rights of the trademark owners. Copyright Siemens AG 2001 All rights reserved The reproduction, transmission or use of this document or its contents is not permitted without express written authority. Offenders will be liable for damages. All rights, including rights created by patent grant or registration of a utility model or design, are reserved. Disclaimer of Liability We have checked the contents of this manual for agreement with the hardware and software described. Since deviations cannot be precluded entirely, we cannot guarantee full agreement. However, the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions. Suggestions for improvement are welcomed. Siemens AG Bereich Automatisierungs- und Antriebstechnik Geschaeftsgebiet Industrie-Automatisierungssysteme Postfach 4848, D- 90327 Nuernberg Siemens Aktiengesellschaft Siemens AG 2001 Technical data subject to change. A5E00097465

Contents 1 Foreword 1-1 2 Introduction to Component based Automation and WinAC PN 2-1 2.1 Product Overview...2-1 2.2 Introduction to WinAC PN...2-3 3 Routing with WinLC PN 3-1 4 Installing WinLC PN 4-1 4.1 Requirements...4-1 4.2 Installing WinLC PN...4-2 4.3 Uninstalling WinLC PN...4-3 5 Commissioning WinLC PN 5-1 5.1 Introduction...5-1 5.2 STEP 7/SIMATIC imap and WinLC PN are installed on the same PC...5-1 5.3 STEP 7/SIMATIC imap are installed on the local PC, while there is at least one WinLC PN on a remote PC...5-3 5.4 STEP 7/SIMATIC imap and WinLC PN are installed on the local PC, while there is at least one WinLC PN installed on a remote PC...5-5 6 Notes on Using WinLC PN 6-1 7 Technical Data for WinLC PN 7-1 8 Index Figures Figure 1-1 SIMATIC Customer Support Hotline...1-3 Figure 2-1 WinLC PN as a Direct User in PROFINet...2-4 Figure 2-2 WinLC PN as a Proxy for other DP slaves...2-5 Figure 3-1 Routing with WinLC PN...3-2 Figure 5-1 STEP 7/SIMATIC imap and WinLC PN are installed on the local PC...5-1 Figure 5-2 STEP 7/SIMATIC imap are installed on the local PC, while WinLC PN is on the remote PC...5-3 Figure 6-1 Setting the IP address and subnet mask under STEP7/Configure hardware...6-2 Figure 6-2 Setting the IP address and subnet mask in SIMATIC imap...6-3 Tables Table 7-1 Technical Data for WinLC PN...7-1 A5E00097465 i

Foreword 1 Aim of this Documentation This document provides the information required to use WinAC PN for Component based Automation. WinAC PN performs the same functions as WinAC Basic Version 3.0, plus the additional features of PROFINet capability, routing capability and support for Windows 2000 Professional. This document is intended for use by engineers, programmers and maintenance personnel with a general knowledge of automation systems and knowledge of Component based Automation and WinAC Basic version 3.0. Basic Knowledge Required We assume that you are familiar with the following documentation: Component based Automation and PROFINet documentation (on the Component based Automation CD-ROM) WinAC Basic version 3.0 documentation (on the WinAC PN V1.0 CD-ROM) Applicability of this Manual This manual applies to WinAC PN version 1.0. Scope of this Documentation This manual describes the functions of WinAC PN as used in Component based Automation. It provides the following information: Integration of WinAC PN into Component based Automation Routing with the WinAC PN Windows Logic Controller Technical Data for WinLC PN A5E00097465 1-1

Foreword Further Support If you have any questions on how to use the products described in this manual that are not answered here, please contact your local Siemens dealer or office. http://www.ad.siemens.de/partner Training Center We can also provide suitable courses to help you get started with WinAC PN and Component based Automation. Please contact your regional or the central training center. Tel: +49 (911) 895 3200.. http://www.sitrain.com SIMATIC documentation on the Internet / Siemens Intranet On the Internet, you can find free documentation at: http://www.ad.siemens.de/support Use the Knowledge Manager at this site to quickly search for the information you require. There is also a Documentation user group for your questions or suggestions concerning Siemens documentation. 1-2 A5E00097465

Foreword SIMATIC Customer Support Hotline Accessible round the clock from anywhere in the world: Figure 1-1 SIMATIC Customer Support Hotline Worldwide (Nuremberg) Technical Support (Toll free) Local time: Mon.-Fri. 7:00 to 17:00 Tel: +49 (180) 5050 222 Fax: +49 (180) 5050 223 E-mail: techsupport@ad.siemens.de GMT: +1:00 Europe / Africa (Nuremberg) Authorization Local time: Mon.-Fri. 7:00 to 17:00 Tel: +49 (911) 895-7200 Fax: +49 (911) 895-7201 E-mail: authorization@nbgm.siemens.de GMT: +1:00 Worldwide (Nuremberg) Technical Support (There is a charge for this service, which can only be accessed with a SIMATIC card) Local time: Mon.-Fri. 0:00 to 24:00 Tel: +49 (911) 895-7777 Fax: +49 (911) 895-7001 GMT: +1:00 America (Johnson City) Technical Support and Authorization Local time: Mon.-Fri. 8:00 to 19:00 Tel: +1 423 461-2522 Fax: +1 423 461-2289 E-mail: simatic.hotline@sea.siemens.co m GMT: 5:00 Asia / Australia (Singapore) Technical Support and Authorization Local time: Mon.-Fri. 8:30 to 17:30 Tel: +65 740-7000 Fax: +65 740-7001 E-mail: simatic.hotline@sea.siemens.co m.sg GMT: +8:00 The languages used on SIMATIC Hotlines are generally German and English, although French, Italian and Spanish are also spoken on the Authorization Hotline. A5E00097465 1-3

Foreword Service & Support on the Internet In addition to our documentation service, you can also access our complete knowledge base online on the Internet. http://www.ad.siemens.de/support There you will find: Latest product information, FAQs (Frequently Asked Questions), downloads, tips and tricks. The Newsletter provides latest information on your products. The Knowledge Manager helps you find the documents you need. Users and specialists from around the world share their experience and knowledge in the Forum. You can find your local partner for Automation & Drives in our contacts database. The Service section provides information on local service, repairs, spare parts and much more. 1-4 A5E00097465

Introduction to Component based 2 Automation and WinAC PN 2.1 Product Overview What is component based automation? As part of Totally Integrated Automation (TIA), Component based Automation is a concept for implementing modular, distributed automation applications based on open standards. This concept meets the demand for increased modularization in the field of plant and machine construction by extensively distributing the intelligent processing required. Component based Automation allows different types of programmable controller to be used as standardized automation components - known as PROFINet components - in large-scale systems. Component based Automation is implemented by the PROFINet standard for programmable controllers in combination with the SIMATIC imap engineering tool. What is PROFINet? To implement Component based Automation, TIA uses the PROFINet standard published by the PROFIBUS User Organization e.v. (PNO). The PROFINet standard defines a cross-vendor communication, automation and engineering model. PROFINet has the following objectives: Open, distributed automation across networks Integrated communication via field bus and Ethernet Use of open IT standards Programmable controllers that conform to the PROFINet standard must offer certain communication interfaces based on Microsoft DCOM (Distributed Component Object Model). A5E00097465 2-1

Introduction to Component based Automation and WinAC PN What is SIMATIC imap? SIMATIC imap is a cross-vendor engineering tool for configuring PROFINet applications. It brings together distributed automation applications in a graphical format so that they can be displayed for the entire plant. All the PROFINet components needed are provided in a standardized format in the form of library elements. Every PROFINet component is a discrete automation function with inputs and outputs which, in turn, can be combined with other functions. These interconnections use Ethernet or PROFIBUS communication links. SIMATIC imap can download the contents of PROFINet components and the associated interconnections to the devices in the plant. During commissioning and while the plant is in operation, you can use SIMATIC imap to look up process data and diagnostic data concerning the devices, and modify parameters and project data for testing purposes. The new engineering tool can also integrate device-specific programming and configuration tools. Product Range The product range for Component based Automation based on the PROFINet standard comprises: PROFINet devices that conform to the PROFINet standard. SIMATIC imap - the engineering tool for Component based Automation. It is used to configure plants and provide a link to device-specific programming, configuration and diagnostic tools. A wide range of existing automation and field devices from various vendors can also be used as PROFINet components. The PNO has also published a specification for the communication mechanisms and engineering model. This allows other devices to be made PROFINetcompliant, and proprietary configuration and programming tools to be linked to SIMATIC imap. 2-2 A5E00097465

Introduction to Component based Automation and WinAC PN 2.2 Introduction to WinAC PN What are WinAC Basic V3.0 and WinLC? WinAC Basic V 3.0 is the SIMATIC software package for PC-based control. It incorporates the Windows Logic Controller, SIMATIC Computing and the Tool Manager. The Windows Logic Controller (WinLC) is a PC-based automation system that allows you to carry out process control tasks from your PC. What is WinAC PN? WinAC PN (PN = PROFINet) performs the same functions as WinAC Basic V 3.0, the only difference being that WinAC PN has been extended to include the following functions for use in Component based Automation: PROFINet capability Routing capability Support for Windows 2000 Professional Note WinAC PN does not support Windows NT. A5E00097465 2-3

Introduction to Component based Automation and WinAC PN PROFINet capability WinLC PN supports the PROFINet standard and participates as a direct user in PROFINet communication functions. Figure 2-1 WinLC PN as a Direct User in PROFINet 2-4 A5E00097465

Introduction to Component based Automation and WinAC PN WinLC PN can also act as linking element for other non PROFINet-compliant DP slaves: Typical examples include distributed peripherals such as ET 200S and ET 200X, which do not support the PROFINet standard. They can, however, be connected to WinLC PN and thus be integrated into PROFINet and Component based Automation. WinLC PN thus acts as a proxy for DP slaves that do not support the PROFINet standard. Figure 2-2 WinLC PN as a Proxy for other DP slaves Routing capability In most automation systems, the programming unit can only be operated via the bus cable (subnet) connected directly to the automation system. In large-scale, networked systems, this requires the programming unit to be connected to a number of different bus cables (subnets) before a remote automation system can be accessed online. STEP 7 V5.1 SP 2 and WinAC PN now allow you to access automation systems online using the PG/PC beyond the boundaries of an individual subnet in order to download user programs or a hardware configuration, or to run testing and diagnostic functions, for example. A5E00097465 2-5

Introduction to Component based Automation and WinAC PN Communication with Industrial Ethernet You will need the following PC module and the associated software and licenses (SIMATIC NET V 6.0) to operate WinLC PN on an Industrial Ethernet: a standard Ethernet card, e.g. a 3COM card. Communication with PROFIBUS-DP To use WinLC PN with PROFIBUS-DP, you will have to add a CP (communication processor) to your PC to allow it to be connected to PROFIBUS-DP. The following CPs are suitable: CP 5611 or CP 5613. You can also use the CP (communication processor) integrated into SIMATIC PGs/PCs to connect to PROFIBUS-DP. The drivers for the above CPs are supplied on the WinAC PN CD-ROM. Order number The order number for WinAC PN is 6ES7 671-0VC01-0YX0. 2-6 A5E00097465

Routing with WinLC PN 3 Introduction WinLC PN V1.0 supports routing, in contrast to the standard version of the Windows Logic Controller in WinAC Basic V3.0. Definition of Routing The routing function allows you to access S7 stations online from your PG/PC beyond the limits of an individual subnet. This means that you can access an intelligent DP slave from the Industrial Ethernet via WinLC PN. Typical applications include: Loading user programs Loading a hardware configuration Running testing and commissioning functions. To do this, special routing tables are automatically generated for the network transitions when the network is configured. These routing tables contain special system data, and must be downloaded at the individual network transitions, i.e. to WinLC PN. When the programming unit subsequently goes online, the route to the selected programmable controller can be found via the network transitions. A5E00097465 3-1

Routing with WinLC PN Routing with WinLC PN With WinLC PN, the term routing is used exclusively to describe accessing the DP slaves incorporated into the WinLC PN DP master system. Routing functions that require a connection to be established via the WinLC PN from a PROFIBUS station to a remote communication partner are not supported. This means that routing from PROFIBUS-DP via the WinLC PN to the Industrial Ethernet is not possible, for example. Figure 3-1 Routing with WinLC PN 3-2 A5E00097465

Installing WinLC PN 4 4.1 Requirements Software Requirements To install WinLC PN, you will need the following: Windows 2000 Professional, service pack 1 You must be logged on with administrator rights. Additional Software Products: You will need the following software to use WinLC PN in Component based Automation: SIMATIC imap version 1.0 for configuring PROFINet STEP 7 version 5.1, service pack 2 or later, for configuration and programming Softnet S7 for Industrial Ethernet (TCP/IP) version 6.0 (part of SIMATIC NET V 6.0) for access via Industrial Ethernet Hardware Requirements Your computer should have at least the following minimum configuration in order to install the WINAC PN components: A PC with Pentium III processor, 450 MHz or faster 128 MB RAM Color monitor, keyboard and mouse (or other pointer) Hard disk with 135 MB free A5E00097465 4-1

Installing WinLC PN 4.2 Installing WinLC PN Recommended Order for Installation We recommend that you install the components in the following order: STEP 7 (optional) WinLC PN Softnet S7 for Industrial Ethernet (TCP/IP) V 6.0 SIMATIC imap (optional) Note If you are using WinLC PN on a remote PC and download the data to the WinLC PN via an Industrial Ethernet, then it is not necessary to install STEP 7 and SIMATIC imap on this PC. Installing WinLC PN Follow the instructions below to install WinLC PN: 1. Insert the WinAC PN CD into the CD-ROM drive on your computer. 2. Use the Windows Start menu (Start > Run) to open the Run dialog box. 3. In the Run dialog box, click on the Browse button and select the installation program (setup.exe) on the CD-ROM. 4. Click on the Open button to accept the Setup.exe program in the Run dialog box. 5. Click on OK to confirm and start the installation program. 6. Follow all the instructions that appear on screen. 7. In the SIMATIC WinAC PN V1.0 Setup: Components dialog, select the components that you wish to install. Select the CP that you wish to install in order to connect to PROFIBUS-DP (CP 5611/CP 5613). In this way, you will install all the drivers for communication via PROFIBUS-DP. 4-2 A5E00097465

Installing WinLC PN 8. Insert the authorization diskette into drive A when the software prompts you to do so. Detailed information on installing the authorization diskette can be found in the WinAC Basic documentation. Result: WinAC PN is installed on your PC and is entered at index 2 on the PC station. This index corresponds to a virtual slot on the PC and tallies with the slot defined in STEP 7/Configure hardware. Note Make sure that index 2 on the PC station is not already assigned to a CP. Click on the component configuration tool on the right of the taskbar for an overview of the procedure for assigning the index on the PC. 4.3 Uninstalling WinLC PN Uninstalling WinLC PN Follow the instructions below to uninstall WinLC PN: 1. Open the Control Panel and double-click on the Add/Remove Programs option. 2. Select the SIMATIC Windows Logic Controller PN V1.0 entry from the list of installed software. Click on the Add / Remove button to uninstall the software. 3. If the Remove released file dialog box appears, click on the "No" button if you are in doubt. Caution If the authorization for the WinLC PN software is transferred or uninstalled incorrectly, it may be irretrievably lost. The readme file on the authorization diskette contains guidelines for installing, transferring and uninstalling your authorization for the WinLC PN software. If you do not follow these guidelines, the authorization for the WinLC PN software may be irretrievably lost. Without this authorization, you can neither download programs to WinLC PN nor modify any programs already downloaded to WinLC Basic. Please read the notes in the readme file on the authorization diskette and follow the instructions for transferring and uninstalling authorizations. A5E00097465 4-3

Commissioning WinLC PN 5 5.1 Introduction Configuration Options with WinLC PN The following section describes the procedure for commissioning your WinLC PN. We differentiate between the three following scenarios: STEP 7/SIMATIC imap and WinLC PN are installed on the local PC STEP 7/SIMATIC imap are installed on the local PC, while WinLC PN is on the remote PC STEP 7/SIMATIC imap and WinLC PN are installed on the local PC, while there is at least one WinLC PN installed on a remote PC 5.2 STEP 7/SIMATIC imap and WinLC PN are installed on the same PC Definition The following diagram illustrates the configuration process for a local PC with WinLC PN and STEP 7/SIMATIC imap installed: Figure 5-1 STEP 7/SIMATIC imap and WinLC PN are installed on the local PC A5E00097465 5-1

Commissioning WinLC PN Procedure 1. Use the commissioning wizard to configure the CPs for connecting to the Industrial Ethernet and PROFIBUS. To run the commissioning wizard, select Start > SIMATIC > SIMATIC NET > Commissioning Wizard. Result: The SIMATIC NET Commissioning Wizard opens. 2. Click on Next and follow the instructions. 3. Please note the following points when making the settings for the Ethernet module: Select Use module in configured PC station for production. Select an index of 3 or higher since index 2 is reserved for the WinLC PN. The index corresponds to a virtual slot in the PC, and must be the same slot that you defined using STEP 7/Configure hardware. 4. Please note the following points when making the settings for the PROFIBUS module: Select Use module for programming only. 5. Click on Next or Finish until you exit the commissioning wizard. 6. Use Start > Settings > Control Panel > Set PG/PC Interface to make the following settings: Select the CP_L2_1 application as the access point, then set the interface parameters on the CP that you use to connect to PROFIBUS-DP. Then select the S7ONLINE (STEP 7) -> PC internal (local) application as the access point. 7. Create the CBA component in SIMATIC imap. Information on this topic can be found in the SIMATIC imap documentation. 8. Before you download the program to the WinLC PN, make sure that the station name in the component configuration tool is the same as the PC station name in SIMATIC imap. Component configuration tool: Click on the icon on the right of the taskbar to start the component configuration tool. Click on the Station name button to set the station names. The default station name is PCStation. SIMATIC imap: In SIMATIC imap, you can change the name of the PC station via the Properties window in the network view. 9. Select Online > Download Selected Device > All to download the program to the WinLC PN in SIMATIC imap. 10. Select Online > Download Selected Device > All to download the program to the intelligent DP slaves in SIMATIC imap. 5-2 A5E00097465

Commissioning WinLC PN 5.3 STEP 7/SIMATIC imap are installed on the local PC, while there is at least one WinLC PN on a remote PC Definition The following diagram illustrates the configuration process with a local PC on which STEP 7 and SIMATIC imap are installed.the WinLC PN is installed on a remote PC that is linked via the Industrial Ethernet. There is no WinLC PN installed on the local PC. Figure 5-2 STEP 7/SIMATIC imap are installed on the local PC, while WinLC PN is on the remote PC Procedure on the remote PC with WinLC PN 1. Use the commissioning wizard to configure the CPs for connecting to Industrial Ethernet and PROFIBUS. To run the commissioning wizard, select Start > SIMATIC > SIMATIC NET > Commissioning Wizard. Result: The SIMATIC NET Commissioning Wizard opens. 2. Click on Next and follow the instructions. 3. Please note the following points when making the settings for the Ethernet module: Select Use module in configured PC station for production. Select an index of 3 or higher since index 2 is reserved for WinLC PN. The index corresponds to a virtual slot in the PC, and must be the same slot that you set using STEP 7/Configure hardware. 4. Please note the following points when making the settings for the PROFIBUS module: Select Use module for programming only. A5E00097465 5-3

Commissioning WinLC PN 5. Click on Next or Finish until you exit the commissioning wizard. 6. Use Start > Settings > Control Panel > Set PG/PC Interface to make the following settings: Select the CP_L2_1 application as the access point, then set the interface parameters on the CP that you use to connect to PROFIBUS-DP. Then select the S7ONLINE (STEP 7) -> PC internal (local) application as the access point Procedure on the local PC with STEP 7/SIMATIC imap (no WinLC PN installed on the PC) 1. Use the commissioning wizard to configure the CPs for connecting to the Industrial Ethernet. To run the commissioning wizard, select Start > SIMATIC > SIMATIC NET > Commissioning Wizard. Result: The SIMATIC NET Commissioning Wizard opens. 2. Click on Next and follow the instructions. Please note the following points when making the settings for the Ethernet module: Select Use module for programming only. This setting is needed in order to be able to download data to the remote WinLC. 3. Click on Next or Finish until you exit the commissioning wizard. 4. Select Start > Settings > Control Panel > Set PG/PC Interface to set the PG/PC interface to S7ONLINE (STEP 7) -> TCP/IP. 5. Create the CBA component in SIMATIC imap. Information on this topic can be found in the SIMATIC imap documentation. 6. Select Special > Assign PG / PC in your project in SIMATIC imap. 7. Select the IP interface from Interface parameter settings on the PG/PC. Detailed information on this dialog can be found in the SIMATIC imap documentation and in the Online Help. 8. Select Online > Download Selected Device > All to download the program to the WinLC PN on the remote PC in SIMATIC imap. 9. Select Online > Download Selected Device > All to download the program to the intelligent DP slaves in SIMATIC imap. 5-4 A5E00097465

Commissioning WinLC PN 5.4 STEP 7/SIMATIC imap and WinLC PN are installed on the local PC, while there is at least one WinLC PN installed on a remote PC Definition The following diagram illustrates the configuration process with a local PC on which the WinLC PN and STEP 7/SIMATIC imap are installed. There is a further WinLC PN installed on a remote PC and connected via Industrial Ethernet. Procedure on the remote PC with WinLC PN 1. Use the commissioning wizard to configure the CPs for connecting to Industrial Ethernet and PROFIBUS. To run the commissioning wizard, select Start > SIMATIC > SIMATIC NET > Commissioning Wizard. Result: The SIMATIC NET Commissioning Wizard opens. 2. Click on Next and follow the instructions. 3. Please note the following points when making the settings for the Ethernet module: Select Use module in configured PC station for production. Select an index of 3 or higher since index 2 is reserved for WinLC PN. The index corresponds to a virtual slot in the PC, and must be the same slot that you set using STEP 7/Configure hardware. 4. Please note the following points when making the settings for the PROFIBUS module: Select Use module for programming only. 5. Click on Next or Finish until you exit the commissioning wizard. A5E00097465 5-5

Commissioning WinLC PN 6. Use Start > Settings > Control Panel > Set PG/PC Interface to make the following settings: Select the CP_L2_1 application as the access point, then set the interface parameters on the CP that you use to connect to PROFIBUS-DP. Then select the S7ONLINE (STEP 7) -> PC internal (local) application as the access point Procedure on the local PC with WinLC PN and STEP 7/SIMATIC imap 1. Use the commissioning wizard to configure the CPs for connecting to Industrial Ethernet and PROFIBUS. To run the commissioning wizard, select Start > SIMATIC > SIMATIC NET > Commissioning Wizard. Result: The SIMATIC NET Commissioning Wizard opens. 2. Click on Next and follow the instructions. 3. Please note the following points when making the settings for the Ethernet module: Select Use module in configured PC station for production. Select an index for the CP. Index 2 is reserved for the WinLC PN. The index corresponds to a virtual slot in the PC, and must be the same slot that you set using STEP 7/Configure hardware. 4. Please note the following points when making the settings for the PROFIBUS module: Select Use module for programming only. 5. Click on Next or Finish until you exit the commissioning wizard. 6. Use Start > Settings > Control Panel > Set PG/PC Interface to make the following settings: Select the CP_L2_1 application as the access point, then set the interface parameters on the CP that you use to connect to PROFIBUS-DP. Then select the S7ONLINE (STEP 7) -> PC internal (local) application as the access point 7. Create the CBA component in SIMATIC imap. Information on this topic can be found in the SIMATIC imap documentation. 5-6 A5E00097465

Commissioning WinLC PN 8. Before you download the program to the WinLC PN, make sure that the station name in the component configuration tool is the same as the PC station name in SIMATIC imap. Component configuration tool: Click on the icon on the right of the taskbar to start the component configuration tool. Click on the Station name button to set the station names. The default station name is PCStation. SIMATIC imap: In SIMATIC imap, you can change the name of the PC station via the Properties window in the network view. 9. First select Online > Download Selected Device > All to download the program to the local WinLC PN in SIMATIC imap. Note You must first transfer the data to the local WinLC PN before you can access the remote WinLC PN, since this is how the local WinLC PN obtains the SDBs that it needs to transmit (route) the data to the remote WinLC PN. 10. Then select Online > Download Selected Device > All to download the program to the remote WinLC PN in SIMATIC imap. 11. Select Online > Download Selected Device > All to download the program to the intelligent DP slaves in SIMATIC imap. A5E00097465 5-7

Notes on Using WinLC PN 6 Notes on configuring WinLC PN using STEP 7/Configure hardware Please note the following points when configuring the WinLC PN with STEP 7: Configure the WinLC PN as a PC station. A CP for connecting the WINLC PN to PROFIBUS-DP is automatically contained in the DP master for the PC station. In Configure hardware, double click on the DP master to open, and then define the properties of the CP for connecting to PROFIBUS-DP. A5E00097465 6-1

Notes on Using WinLC PN Setting the IP address of the CP for connection to an Industrial Ethernet To do this, you must assign an IP address and a subnet mask to the CP for connecting to the Industrial Ethernet, both using Configure hardware and in SIMATIC imap. 1. Under Configure hardware, select the CP properties > Properties > Parameters dialog box to set the IP address and subnet mask for the CP for connecting to the Industrial Ethernet. Note The properties of the Ethernet interface must tally with the properties that you entered using the commissioning wizard. Figure 6-1 Setting the IP address and subnet mask under STEP7/Configure hardware 6-2 A5E00097465

Notes on Using WinLC PN 2. In SIMATIC imap, select the WinLC PN and right click to select the properties. 3. Enter the IP and subnet addresses in the General dialog box. Figure 6-2 Setting the IP address and subnet mask in SIMATIC imap A5E00097465 6-3

Technical Data for WinLC PN 7 Introduction This chapter contains the most important technical data for WinLC PN as used in Component based Automation. Note Further technical data concerning WinLC PN can be found in the manual for WinAC Basic version 3.0. Technical data Tabelle 7-1 Technical Data for WinLC PN WinLC PN Engineering System STEP 7, V 5.1, service pack 2 Possible communication ports (via communication Industrial Ethernet processors added to the PC) PROFIBUS-DP MPI Hardware configuration Routing capability Number of interconnections Total Per PROFINet component Number of PROFINet devices that can be connected to WinLC PN Transmission frequency (property of the interconnection in SIMATIC imap) Max. response time before substitute values are applied As for WinLC in WinAC Basic Yes Max. 1500 Max. 100 inputs / 100 outputs Max. 60 DP slaves Multiples of 10 ms 2 x transmission frequency x ping factor; the ping factor is set to 10 by default) A5E00097465 7-1

Index Aim of this Documentation 1-1 Applicability of this manual 1-1 Basic knowledge required 1-1 Commissioning 5-1 Communication 2-6 Component based Automation 2-1 Configuring CP with STEP 7/Configure hardware 6-1 Customer Support 1-3 Further support 1-2 Hardware requirements 4-1 Hotline 1-3 Industrial Ethernet 2-6 Installation 4-2 Order 4-2 Internet 1-4 Order number 2-6 Process control 2-3 Product range 2-2 PROFIBUS User Organization e.v. (PNO) 2-1 PROFIBUS-DP 2-6 PROFINet 2-1 PROFINet standard 2-1 Routing 3-1 Scope of this Documentation 1-1 Service 1-4 Setting the IP address 6-2 SIMATIC Customer Support Hotline 1-3 SIMATIC documentation on the Internet 1-2 SIMATIC imap 2-2 Software requirements 4-1 Support 1-4 Technical data 7-1 Totally Integrated Automation 2-1 Training Center 1-2 Uninstalling 4-3 WinAC Basic 2-3 WinAC PN 2-3 A5E00097465 Index-1