Power Series Transfer Switch

Similar documents
Power Series Transfer Switch

Power Series Transfer Switch

Power Series Transfer Switch

Transfer Switches 5.1 Transfer Switch Equipment Product Selection Guide... Product Description... Application Description...

SECTION 16496E ATS MOLDED CASE WITH ATC 900 CONTROLLER

Transfer Switches 5.1 Transfer Switch Equipment Product Overview Product Selection Guide... Product Description... Application Description...

Transfer Switches Magnum-Based Designs

LOW VOLTAGE BYPASS/ISOLATION BREAKER BASED AUTOMATIC TRANSFER SWITCHES SECTION 16496D

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

Transfer Switches Magnum-Based Designs

Transfer Switches Contactor-Based Designs

Transfer Switches Magnum-Based Designs

Series TS Amp. Automatic Transfer Switches

ASCO SERIES 300 Service Entrance Power Transfer Switch

7000 SERIES Power Switching Solutions. Closed Transition Transfer Switching. Delayed Transition Transfer Switching

4000 SERIES Power Transfer Switches Product Features

Zenith ZT30 30-Cycle Automatic Transfer Switch

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

ASCO Series 300 Power Transfer Switches for Power Outage Protection

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

Medium-Voltage Circuit Breaker-Type Automatic Transfer Switches and Bypass/Isolation Switches

Power Switching & Controls for Business-Critical Continuity

Model KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

ASCO SERIES 200 Power Transfer Switches

SECTION SWITCHBOARDS

TS 880 AUTOMATIC TRANSFER SWITCHES

15-80 ka surge protection Hz line frequency <.5 ns response time Available in units noted from 15-1,200 Amps

Power Switching & Controls for Business-Critical Continuity

Moulded Case Circuit Breakers Selection Information

PD-Series. Emergency Standby. General Description. Available Modes of Operation. Standard Features. User Interface. Communication and Controls

FUSERBLOC from 30 to 800 A

Thermal-Magnetic / Magnetic Only Molded Case Circuit Breakers Introduction

VisoVac padmount fault interrupter

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

Model: KEP. Transfer Switch Standard Features. Automatic Transfer Switches Service Entrance Rated. Enclosed Contact Power Switching Units.

Series 300 POWER TRANSFER SWITCHES MAXIMUM RELIABILITY & EXCELLENT VALUE FEATURES

Experience, innovation and reliability

STANDARD SUBMITTAL PACKAGE

GE Zenith ZDEC Modular Paralleling Switchgear

SUGGESTED SPECIFICATION CLOSED TRANSITION AUTOMATIC TRANSFER SWITCH WITH LOAD BREAK BYPASS/ISOLATION OPERATION WITH RPTCS MICROPROCESSOR CONTROL

Bulletin 1494H Heavy Duty Safety Switches

Medium Voltage Metal-Enclosed Power Capacitor Banks

Maximum Reliability & Excellent Value. Features. UL Listed Withstand & Close-On Ratings. Series 300 Power Transfer Switches

SEL-710 Motor Protection Relay

251 Nuthatch Court Three Bridges, New Jersey Office: Fax: USER S MANUAL

soft load power transfer solutions for continuous, reliable power

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

ASCO Series 300 Generator Paralleling System

ASCO 7000 Series POWER TRANSFER SWITCH

SACE Emax 2 Specification guide

Cutler-Hammer. Westinghouse Transfer Switch Equipment. IQ Transfer

I-Line Panelboards. Innovative design, smart bus technology, and simple installation

Power Control Systems

JK Series POWER DISTRIBUTION. Solid State Starters Medium Voltage A

PDI Modular Compact Remote Power Panel

ASCO Power Transfer Load Centers. Power Switching & Controls for Business-Critical Continuity

SECTION DISTRIBUTION SWITCHBOARDS

S&C Micro-AT Source-Transfer Controls PHOTO SHEET. For use in S&C Metal-Enclosed Gear

IPS INTELLIGENT PUMP STARTER

Power Sensing Products

M-5072 Retrofit Kit For M-4272 Digital Motor Bus Transfer System

Metal-enclosed interrupter 5 kv-15 kv usa.siemens.com/siebreak

The ASCO 7000 Series. Protecting data centers, hospitals, airports, retail stores and other facilities

FP-5000 Feeder Protection

FP5000. Refer to for the latest information on this constantly evolving product

reliable company...caterpillar

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

SUGGESTED SPECIFICATION SINGLE OPERATOR OPEN TRANSITION AUTOMATIC TRANSFER SWITCH WITH RPTCS MICROPROCESSOR CONTROL

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

ATC-300+ Controller Modbus Communications Guide

4.3. Switchboards. Contents Description Pow-R-Line Drawout Molded Case Circuit Breaker Switchboards Product Selection...

EMS 1Ø, 120 ~ 230V, 1/10-25HP 3Ø, 200 ~ 600V, 1/2-300HP

SEM3 - Embedded Micro Metering Module

Disconnect Switches. Safe Switching and Disconnecting

SECTION 16450: NON-AUTOMATIC TRANSFER SWITCH / QUICK CONNECT GENERATOR SWITCHBOARD <S> <OM>

PHOENIX CONTACT Features

PanelFAST. Setting a new standard for immediate product availability with Square D Ready to Install (RTI) Panelboards

Medium Voltage Metal-Enclosed Harmonic Filter Systems

SIL-A. Overcurrent and Earth Fault Relay for Primary and Secondary Distribution. Main characteristics

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

Power Xpert Branch Circuit Monitor

H704-42(H)(E), H704-42/1(H)(E)

ASCO Medium Voltage Power Transfer Switches

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

soft load power transfer solutions for continuous, reliable power

GE Digital Energy Power Quality. Zenith ZTG Series. Low-Voltage Automatic Transfer Switches

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

FTA1350 WYE-DELTA CLOSED FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

SECTION ( ) LIGHTING CONTROL PANELBOARD

FTA750 LIMITED SERVICE FIRE PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES

ASCO Series 300 Power Transfer Switches

ASCO Series 300 Power Transfer Switches

Application Techniques CENTERLINE 2100 Motor Control Centers

Eaton s Innovative Technology Surge Suppression Guideform Specification High Exposure DIVISION 16 SECTION 16289

ASCO 7000 Series IEC Medium Voltage Power Transfer Switches

Transcription:

Service Entrance Rated Power Frame Type losed Transition Power Series Transfer Switch 1000-5000 mps Power Series 1 of 5 utomatic Transfer Switch, 100% Service Entrance Rated 1000 5000, up to 600V, 50/60 Hz 3 or 4 poles NEM 1 or 3R losed Transition with Inphase or Delayed UL1008 Listed S 22.2 No. 178 ertified ODES ND STNDRDS: UL1008 Listed NFP 70, 99, 110, 37 NE 700, 701, 702, 708 ISO9001, 8528, 3046, 7637, Pluses #2b, 4 NEM IS10, MG1, 250, IS6, 1 NSI 62.41 DESRIPTION: Generac s Service Entrance Power Series Transfer Switch integrates automatic power switching with required disconnecting, grounding, and bonding for use as service entrance equipment. The integrated service entrance power switch meets all National Electrical ode requirements for service entrance use in a compact package. The switches are rated for full load transfers in critical operating, emergency, legally required, and optional power systems. Designed with integral over current protection and a 100% rated disconnect breaker for unmatched safety, performance, and reliability. The full assembly is listed to UL 1008 with exceptional 3 cycle withstand and close on ratings. Generac s Power Frame Type Transfer Switch has short time ratings for selective coordination and a high speed switching time of < 3 cycles to minimize the effect of power disturbances. The control s color display and mimic bus diagrams simplifies programming, routine operation, data presentation, and setting adjustments. The intuitive, grouped data screens along with the supervisory and highly customizable data acquisition allow the ser to customize to their needs. Standard features include Modbus RTU, extensive user customizable input/ outputs, 450 event log with event capture for the most recent 12, with 3 phase sensing on both sources, plus load for voltage, frequency, sequencing, loss, and unbalance. Seismic: I 2009, 2010, I 2012, SE 7-05, SE 7-10, I-ES -156 (2012) IE 61000 EM Testing & Measuring S 22.2 No. 178 ertified n automatic closed transition transfer switch (make-before-break) requires the normal and emergency sources to be synchronized. The controller monitors the voltage and frequency of both power sources with an anticipatory algorithm; phase angles must be within 8 electrical degrees. synchronization timer is initiated (TST, 1-60 min adjustable) to complete the transfer and parallels 100ms or less. If the TST times out and the transfer switch has not reached synchronization, the transfer switch will remain connected to the current Source, and a failure to transfer alarm will be displayed. The switch can also be configured to operate in open transition mode if there is a fail to transfer in closed transition.

2 of 5 Power Series, Service Entrance Rated Power Frame Type, losed Transition STNDRD FETURES: High Withstand and lose on s Safe manual transfer under load Front ccess able or bus entry is Top, ottom or oth Isolated ompartments for improved safety 4.3 inch olor Display Mimic diagram with Source vailable and onnected LED indication Event logging and recording 450 time-stamped events System TEST pushbutton Programmable plant exerciser Field-selectable multi-tap transformer panel permits operation on a wide range of system voltages Modbus RTU VOLTGE ND FREQUENY SENSING: 3-Phase under and over voltage sensing on normal and emergency sources 3-Phase under and over voltage sensing on load Under and over frequency sensing on normal and emergency Selectable settings: single or three phase voltage sensing on normal, emergency and load 50 or 60Hz Phase sequence sensing for phase sensitive loads ONTTS: Source available: Source-1 Present, 2-N.O. & 2 N.. Source-2 Present, 2-N.O. & 2 N.. Switch position: Source-1 Position, 1-N.O. & 1-N.. Source-2 Position, 1-N.O. & 1-N.. Pre Transfer ontact: 1-N.O. & 1-N.. Standard ontrol Parameters vailable ONTROL INPUTS (4 STNDRD): ONTROL OUTPUTS (4 STNDRD): Monitor Mode Load sequence TS not in automatic ypass Timers Selective Load shed General alarm Lockout Load bank control TS in test Manual Retransfer On/Off Pre/post-transfer Engine test aborted Manual Retransfer Pre-transfer ooldown in process Slave In User remote control Engine start contact status Remote Engine Test Source 1 available (standard) Generator 1 start status Preferred Source Selection Source 2 available (standard) Generator 2 start status Go to Emergency Source 1 connected Emergency inhibit on Emergency Inhibit Source 2 connected Go to Neutral Up to 20 available with Expandable Input/Output Modules OPTIONL FETURES: Digital Multi-function Power Quality Metering Ethernet onnectivity Draw out construction Remote nnunciator Panel with ontrol Remote Multi-switch nnunciator Panel with ontrol TVSS Stainless steel cover for controller Selectable Retransfer Manual Generator Retransfer Space Heater with Thermostat Maintenance Selector Switch SERVIE ENTRNE RTED: For service entrance and other applications, Digitrip solid-state trip units can be integrated into the power switching section. This eliminates the need for separate upstream protective devices, saving cost and space. vailable with various combinations of long, short time, instantaneous, ground fault protection and communications. ontact factory for optional trip units.

Power Series Power Series, Service Entrance Rated Power Frame Type, losed Transition ontact Wear Indication 3 of 5 T-900 ontroller Source 2 Drawout Power ase Switch or reaker is Optional Keyed Switch for Service Entrance Option Transfer Switch mpere TRNSFER SWITH WITHSTND RTINGS: Systems oordination Information Withstand, losing and Interrupting s When Used with Upstream ircuit reaker 3 ycle 600V (k) 30 ycle 2 600V (k) 1000 100 85 1200 100 85 1600 100 85 2000 100 85 2500 100 85 3000 100 85 3200 100 85 4000 100 85 1 5000 85 1 1. UL 1066 short-time rating 2. s used for coordination with upstream breakers with short-time ratings

Power Series, Service Entrance Rated Power Frame Type, losed Transition UNIT DIMENSIONS: 1000 3200 Fixed-Mount NEM 1 1000 3200 Fixed-Mount NEM 3R 4 of 5 *For enclosures alternative than NEM 1 and 3R, contact factory. Power Frame Fixed-Mount Transfer Switches pproximate Dimensions in Inches (mm) mpere NEM 1 Enclosed Fixed-Mount Transfer Switch 1000-2000 3 90.00(2286.0) 32.00 (812.8) 48.00 (1219.2) 1050 (476) 1000-2000 4 90.00(2286.0) 32.00 (812.8) 48.00 (1219.2) 1250 (567) 2500-3200 3 90.00(2286.0) 44.00 (1117.6) 48.00 (1219.2) 1900 (863) 2500-3200 4 90.00(2286.0) 44.00 (1117.6) 48.00 (1219.2) 2000 (910) mpere NEM 3R Enclosed Fixed-Mount Transfer Switch 1000-2000 3 90.00(2286.0) 32.00 (812.8) 63.00 (1600.2) 1600 (726) 1000-2000 4 90.00(2286.0) 32.00 (812.8) 63.00 (1600.2) 1600 (726) 2500-3200 3 90.00(2286.0) 44.00 (1117.6) 63.00 (1600.2) 2400 (1090) 2500-3200 4 90.00(2286.0) 44.00(1117.6) 63.00 (1600.2) 2500 (1135) Standard Terminals mpere Normal, Emergency, and Load Neutral 1000-2000 (6) 3/0-750 MM (24) 4/0-500 MM 2500-3200 (9) 3/0-750 MM (36) 4/0-500 MM

Power Series Power Series, Service Entrance Rated Power Frame Type, losed Transition UNIT DIMENSIONS: 1000 3200 Drawout NEM 1 1000 3200 Drawout NEM 3R 5 of 5 *Seismic mounting brace adds an additional 3 inches to each side - front left and front right side and 3 inches additional to rear side. Power Frame Drawout Transfer Switches pproximate Dimensions in Inches (mm) mpere NEM 1 Enclosed Drawout Transfer Switch 1000-2000 3 90.00(2286.0) 32.00 (812.8) 60.00 (1524.0) 1600 (727) 1000-2000 4 90.00(2286.0) 32.00 (812.8) 60.00 (1524.0) 1900 (864) 2500-3200 3 90.00(2286.0) 44.00 (1117.6) 60.00 (1524.0) 2500 (1134) 2500-3200 4 90.00(2286.0) 44.00 (1117.6) 60.00 (1524.0) 2800 (1270) mpere Number of NEM 3R Enclosed Drawout Transfer Switch 1000-2000 3 90.00 (2286.0) 32.00 (812.8) 75.00 (1905.0) 2100 (953) 1000-2000 4 90.00(2286.0) 32.00 (812.8) 75.00 (1905.0) 2400 (1089) 2500 3200 3 90.00 (2286.0) 44.00 (1117.6) 75.00 (1905.0) 3000 (1362) 2500 3200 4 90.00 (2286.0) 44.00 (1117.6) 75.00 (1905.0) 3300 (1499) Standard Terminals mpere Normal, Emergency, and Load Neutral 1000-2000 (6) 3/0-750 MM (24) 4/0-500 MM 2500-3200 (9) 3/0-750 MM (36) 4/0-500 MM *For 4000 and 5000 dimensions, please contact factory. Generac Power Systems, Inc. S45 W29290 HWY. 59, Waukesha, WI 53189 generac.com 2015 Generac Power Systems, Inc. ll rights reserved. ll specifications are subject to change without notice. ulletin 0192580SY- /Printed in U.S.. 3/27/15