Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Similar documents
Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

GSV-1A4 M12/2 M12/2. Highlights

GSV-2MSD-DI DMS-Data Logger

Strain Gage Measuring Amplifier GSV-1

GSV-3USBx2 3,5mV/V 4,2V

Strain Gage Measuring Amplifier GSV-3

Version: 16/12/2013. GSV-2MSD-DI Data Logger Instruction manual

Multi-axis force-torque-sensor K6D27

GSV-6BT GSV-6BT. Description

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

Technical data. Your advantages

MODEL 9250 Preliminary data sheet

digiclip Data sheet DF31DP Special features B en

DC-204R DC-204Ra SMART DYNAMIC STRAIN RECORDER. 200kHz 2GB UPS. Strain DC voltage Temperature. TML Pam E-442B. capacity. High speed sampling

Analog Modules AS-i IP65, M12

6-Channel measuring amplifier GSV-6BT

digiclip Data sheet DF31CAN Special features B en

Characteristics and functioning

Inductive displacement measurement system model series IE25P with programmable analogue interface

User Manual CTP64-Rotate

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Operation Manual for Sensor Interface LCV-USB2

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

BP16 Backplane for MAL Amplifiers

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

OPERATION MANUAL - DS-MOD-

LVX Control Unit. Features:

AS-Interface I/O Module

6A27 6A40 6A68 6A154 6A175

Characteristics and functioning

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Cube67 - Modular I/O station

EDX-10 Series. Compact Recording System

Analog Modules AS-i, IP67, M12

the Interactive Catalog

SAI Active Universal Pro

Technical data. Your advantages

Assembly Instructions scancontrol 2700/2750 (500)

Issue 03/2013. The Electronic Load

RTC 300/RTC 600 Installation instructions scan

Data Sheet for Linear Sensors

Time Counters mini "h", DC Version

Electrical Interface 21MTC

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

EDX-10 Series. Compact Recording System

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Temperature measurement board, optically isolated, 16/8/4 channels for thermocouples, Pt100, RTD, 18-bit

6224 Ethernet-Based Strain Measurement Module

Technical data. General specifications. Indicators/operating means

User Manual AD101B. Digital Transducer Electronics Amplifiers Hardware and Functions. I en

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

6-Axis Force and Torque in All Six Axes 50N/1Nm to 50kN/5kNm Capacities Compact Size. Specifications

SoundwebTM. Installation Guide

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Precision thermometer Model CTR2000

Technical Data. C-DIAS-MULTI l/o MODULE CIO 013

DCA - 10 / DCA TTS Systems

BX8 8-Channel Digital Amplifier

Data sheet * * Digital 2-channel transmitter for direct connection to bus-capable automation devices. Design and mode of operation

E101 - Strain Gauge Transducer Display Module. Contents

PO Box 409 Hanover, MD TEL (410)

PMIX (selectable sensor types)

Hand-held thermometer Model CTH7000

VE-53 Sensor Uniaxial / Triaxial Surface and Downhole Velocity Sensor. Operation Manual

standard, short, preferential, top

SCP for Plastics Processing

POSIROT. PRAS26 Magnetic Angle Sensor. Magnetic Angle Sensors. Datasheet

POSIROT. PRAS2EX Magnetic Angle Sensor. Magnetic Angle Sensors (Dust-Ex-proof) Datasheet

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Blue Point Engineering

Modular controllers CECX

Isolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

High-speed 2-channel IN / 2-channel OUT data I/O system

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

Data Sheet for Joysticks

Precision thermometer Model CTR5000

IPM650 Intelligent Panel-Mount Display

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

PC-CARD-DAS16/12 Specifications

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

Installation Instructions for: Channel Thermocouple Amplifier

CANcheck. Installation Tester for CAN/CANopen Networks MANUAL ENGLISH

IB080QM65VA3 Part Number

VersaMax IP I/O Module

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE HVA-100 HIGH VOLTAGE AMPLIFIER MODULE FOR EPMS SYSTEMS

D-Series Inclinometer

Precision Hand-held Thermometer

PC-CARD-DAS16/16 Specifications

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Mechanical, analog system comprising sensor and processor for accurately recording the position of gripper jaws.

User Manual INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

Expansion Module HZS 541-1S

Analogue Input Module. user manual All Models

Strain Gauge Converter

USB-2527 Specifications

System StrainSmart Data Acquisition System. Micro-Measurements FEATURES DESCRIPTION MODEL 5100B SCANNER SPECIFICATIONS

Transcription:

Strain gauge Measuring Amplifier GSV-A8 Instruction manual GSV-A8, GSV-A8USB, GSV-A6USB GSV-A8USB SubD5 (front side) GSV-A8USB M2 (front side) GSV-A6USB (rear side) GSV-A8USB K6D (front side) Version: 9.06.203

Contents Strain gauge Measuring Amplifier GSV-A8... Description...3 Advantages...3 Terminal assignment...4 Wiring diagram for quarter bridges and half bridges...4 Pin assignment for 37-pin Sub-D...5 Assignment for GSV-A8 without USB port...5 Assignment for GSV-A8USB with USB port...6 Assignment for GSV-A6USB with USB port...7 Activating the bridge completion for strain gauge quarter bridges...8 Accessories...8 Technical data...9

Description The measuring amplifier GSV-A8USB is a DC voltage measuring amplifier with USB interface. The resolution is 6 bit with a total sampling rate of 250kHz. The integrated A/D measurement card NI USB 620 has 6 analogue input channels and digital inputs/outputs which are led outside on a 37-pin Sub-D socket. To upgrade to 6 channels, a second, structurally identical housing without A/D measuring card is connected to the basic unit via a 37-pin flat ribbon cable. Several 6-channel devices can be evaluated using the software. The analogue input signals from the strain gauges are amplified by 8 or 6 precision measuring amplifiers GSV-L to ± 5 volt and digitalised by the integrated A/D card with USB interface. A supplement for quarter bridges 350 ohm, and for half bridges 20, 350 or 000 ohm is included in the GSV-USB and can be activated via solder bridges. The benefit of the GSV-L measuring amplifier used is the low-noise amplification and automatic analogue zero adjustment. The zero adjustment is triggered via a switch or via software. The zero point is stored internally and is available again after a voltage interruption. Due to the automatic zero adjustment, the low-noise amplifier and the optimally adjusted Bessel filter, high input amplifications can also be set for the A/D digital converter in order to record the smallest signals. The supply voltage is 2...24V DC and is supplied via a plug-in power supply provided. Advantages Features: USB port, 6 Bit, 250kHz total sampling rate, 8x strain gauge input, 8x analogue input ±0 V, 8x IO Optional 6x strain gauge input Zero adjustment across 00% of the measuring range Integrated bridge completion 350 ohm can be activated through solder bridges, Analogue filter 250Hz, optional 2.5kHz or 0kHz compact dimensions and low weight, simple connection of strain gauge full, half and quarter bridges via 5-pin M2 or Sub- D5 plug connectors, automatic zero adjustment with tare switch across 00% of the measuring range (3.5mV/V), high limit frequencies up to 0kHz per channel as an order option (250Hz standard) Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, info@me-systeme.de, www.me-systeme.de 3

low-noise input stage for high measurement resolution, high amplification of the output signal possible through automatic zero adjustment, low current consumption and supply with car supply voltage, stable strain gauge supply for up to 4 parallel 350 ohm full bridges per channel. Terminal assignment Socket Spring contacts Pin No. Terminal assignment ME SAC-5P (Top view) +U S positive bridge power supply brown brown 2 -U S negative bridge power supply white white 3 +U D positive differential input green blue 4 -U D negative differential input yellow black 5 AUX quarter bridge completion 350Ω, grey grey Table : Terminal assignment round connector 5-pin M2 Socket Spring contacts Pin No. Terminal assignment ME SAC-5P (Top view) GND (-Us) for shielding 8 2 4 3 5 9 5 Table 2: Terminal assignment Sub-D 5 socket Plug Pin contacts 5 -U S negative bridge power supply white white 6 +U S positive bridge power supply brown brown 8 +U D positive differential input green blue 5 -U D negative differential input yellow black 4 AUX quarter bridge completion 350Ω grey grey Pin No. Terminal assignment SAC-5P (Top view) Supply voltage 2...24 V DC brown 2 4 3 2 not assigned white 3 GND supply voltage blue 4 Tare black Table 3: Connection for voltage supply, M8 plug connector Wiring diagram for quarter bridges and half bridges To connect quarter or half bridges, the measuring amplifier must be configured accordingly. The supplement resistors are connected by closing the solder bridges. For closed solder bridges, the connection of strain gauge full bridges is possible but reduces the sensitivity to the supplied calibration by approx. % and is independent of the terminal resistance of the strain gauge. 4 Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, info@me-systeme.de, www.me-systeme.de

Strain gauge quarter bridges are connected in three-wire technology. As a result, the influence of the supply cable on the zero point and the zero point drift is compensated. Quarter bridge Half bridge +Us brown +Us brown - Aux -Ud +Ud grey 5 black 4 blue 3 + Aux -Ud +Ud grey 5 black 4 blue 3 + -Us white 2 -Us white 2 5-pin round connector 5-pin round connector +Us 6 +Us 6 - Aux -Ud +Ud 4 5 8 + Aux -Ud +Ud 4 5 8 + -Us Shield 5-pin Sub-D socket 5 -Us Shield 5-pin Sub-D socket 5 Pin assignment for 37-pin Sub-D 9 37 20 Assignment for GSV-A8 without USB port PIN GSV-A8 CH - Channel 2 CH2 - Channel 2 3 CH3 - Channel 3 4 CH4 - Channel 4 5 CH5 - Channel 5 6 CH6 - Channel 6 Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, info@me-systeme.de, www.me-systeme.de 5

7 CH7 - Channel 7 8 CH8 - Channel 8 20-27 GND / Ground 35 Tare - function - Display by error LED All pins not listed are not connected / n.c. Assignment for GSV-A8USB with USB port PIN GSV-A8USB NI-620-USB AI 8 Input ±0V 2 AI 9 Input ±0V 3 AI 0 Input ±0V 4 AI Input ±0V 5 AI 2 Input ±0V 6 AI 3 Input ±0V 7 AI 4 Input ±0V 8 AI 5 Input ±0V 9 CH - Channel 0 CH2 - Channel 2 CH3 - Channel 3 2 CH4 - Channel 4 3 CH5 - Channel 5 4 CH6 - Channel 6 5 CH7 - Channel 7 6 CH8 - Channel 8 Output ±5V AI 0 Input assigned Output ±5V AI Input assigned Output ±5V AI 2 Input assigned Output ±5V AI 3 Input assigned Output ±5V AI 4 Input assigned Output ±5V AI 5 Input assigned Output ±5V AI 6 Input assigned Output ±5V AI 7 Input assigned 20-27 Ground Analogue ground AI GND Analogue ground 28 P0.0 Digital input 29 P0. Digital input 30 P0.2 Digital input 3 P0.3 Digital input 32 P.0 Digital output 33 P. Digital output 34 P.2 Digital output 6 Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, info@me-systeme.de, www.me-systeme.de

35 Tare reserved P.3 Reserved for Tare -Function Display by error LED 36 D GND Digital ground All pins not listed are not connected / n.c. Assignment for GSV-A6USB with USB port The measuring amplifier GSV-A6USB consists of x GSV-A8 and x GSV-A8USB. Both devices are connected via a flat ribbon cable at the rear. PIN GSV-A6USB NI-620-USB Channel 9 Output ±5V AI 8 Input assigned 2 Channel 0 Output ±5V AI 9 Input assigned 3 Channel Output ±5V AI 0 Input assigned 4 Channel 2 Output ±5V AI Input assigned 5 Channel 3 Output ±5V AI 2 Input assigned 6 Channel 4 Output ±5V AI 3 Input assigned 7 Channel 5 Output ±5V AI 4 Input assigned 8 Channel 6 Output ±5V AI 5 Input assigned 9 Channel Output ±5V AI 0 Input assigned 0 Channel 2 Output ±5V AI Input assigned Channel 3 Output ±5V AI 2 Input assigned 2 Channel 4 Output ±5V AI 3 Input assigned 3 Channel 5 Output ±5V AI 4 Input assigned 4 Channel 6 Output ±5V AI 5 Input assigned 5 Channel 7 Output ±5V AI 6 Input assigned 6 Channel 8 Output ±5V AI 7 Input assigned 20-27 Ground Analogue ground AI GND Analogue ground 28 P0.0 Digital input 29 P0. Digital input 30 P0.2 Digital input 3 P0.3 Digital input 32 P.0 Digital output 33 P. Digital output 34 P.2 Digital output 35 Tare reserved P.3 Reserved for Tare -Function Display by error LED 36 D GND Digital ground All pins not listed are not connected / n.c. Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, info@me-systeme.de, www.me-systeme.de 7

Activating the bridge completion for strain gauge quarter bridges For closed solder bridges, connecting quarter bridges to 350 ohm is possible. The use of half and full bridges is also possible with closed solder bridges. The measurement result for full bridges is then displayed too small by approx. % to 2%. Optionally, the measuring amplifier is supplied with 20 ohm or 000 ohm bridge completion. Accessories Sensor-actuator cable with M2 plug connector Earthing plug (included in scope of delivery) Connector GSV-A8-37T for connecting devices GSV-A8USB and GSV-A8, (included in the scope of delivery for GSV-A8USB) 8 Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, info@me-systeme.de, www.me-systeme.de

Technical data Accuracy class 0, % Inputs Measurement range 2 (optional 3.5) mv/v Resolution of the input signal 6 bit Strain gauge inputs Full bridge 70... 50000 ohm ohm Common mode rejection for 60Hz common-mode signal 95-0 db Measuring frequencies Total sampling rate 250 khz Analogue filter 250, optional 2500 or 0000 Hz Outputs Analogue output Output resistance Bridge supply voltage 5 volt Zero adjustment Tolerance Duration Resolution on falling edge after at least 4ms high level (3.5V... 30V) Supply Supply voltage Power consumption 24V (2V) DC Temperature range Nominal temperature range Storage temperature range Drift of zero point Drift of sensitivity Dimensions ±5 47 <5, type <2.5 <90...28 300-0 +65-20 +65 < 0.05 < 0.0 volt ohm mv ms V DC ma C C %/0 C %/0 C L x W x H 75 x 38 x 45 mm x mm x mm Protection class AD converter IP40 Type NI USB 620, Input voltages -0...+0 V Number of digital inputs 4 Number of digital outputs 4 Counter timer 2 (32 Bit) Tel +49 (0)3302 78620 60, Fax +49 (0)3302 78620 69, info@me-systeme.de, www.me-systeme.de 9

Subject to modifications. All details describe our products in a general form. They constitute neither warranty of characteristics in the sense of 459, Paragraph 2, of the German Civil Code nor grounds for liability. Made in Germany Copyright 999-203 ME-Meßsysteme GmbH