Intel Server Board S2600BP Intel Compute Module HNS2600BP Product Family

Similar documents
Basic Rail Kit Install Guide for Intel Server Chassis

Allen-Bradley Drives. Instructions. (For 6180 Industrial Computers)

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Dell OptiPlex All-in-One. Stand Installation Guide

Upgrading and Servicing Guide

User Guide for NUC8i5BEK, NUC8i3BEK. Intel NUC Kit NUC8i5BEK Intel NUC Kit NUC8i3BEK. User Guide

Intel NUC Kit DC53427HYE User Guide. Intel NUC Kit DC53427HYE

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK User Guide

Upgrading and Servicing Guide

Intel NUC Kit D54250WYKH & D34010WYKH User Guide. Intel NUC Kit D54250WYKH Intel NUC Kit D34010WYKH User Guide

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

Replacing the Gateway M305 Optical Drive

Intel NUC Kit NUC8i7HNK & NUC8i7HVK User Guide. Intel NUC Kit NUC8i7HNK Intel NUC Kit NUC8i7HVK. User Guide

Replacing the Power Supply

Intel NUC Kit NUC5i3MYHE & NUC5i5MYHE User Guide. Intel NUC Kit NUC5i3MYHE Intel NUC Kit NUC5i5MYHE User Guide

Intel NUC Kit DN2820FYKH User Guide. Intel NUC Kit DN2820FYKH User Guide

User Guide. Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNKP. Intel NUC7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ

Intel NUC Kit NUC6CAYS User Guide

Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

Replacing the Gateway M275 Keyboard

Dell OptiPlex 7460 All-in-One. Intel Optane card installation guide

Intel NUC Kit NUC7i3BNHX1 with Intel Optane Memory. Intel NUC Kit NUC7i5BNHX1 with Intel Optane Memory

OptiPlex XE3 Tower. Remote Power Switch Installation Guide. Regulatory Model: D18M Regulatory Type: D18M005

Replacing the RAID Battery Backup Unit Assembly on Series 3 FireSIGHT 3500 Defense Centers, Version 5.x

User Guide. Intel NUC 8 Business, a Mini PC with Windows 10 NUC8i7HNKQC. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7HVKVA

Precision 3930 Rack. Zoom card Installation Guide. Regulatory Model: D24M Regulatory Type: D24M003

Dell XPS 14z Owner s Manual

Cooling Module Install Guide: Intel Storage System SSR212MA A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/ Products

Intel NUC Kit NUC7i7BNH, NUC7i5BNH & NUC7i3BNH User Guide. Intel NUC Kit NUC7i7BNH Intel NUC Kit NUC7i5BNH Intel NUC Kit NUC7i3BNH User Guide

Installing a New Solo 1150 Hard Drive

Dell Inspiron N5110 Service Manual

Intel NUC7 Home, a Mini PC with Windows 10 NUC7i3BNHXF. Intel NUC7 Home, a Mini PC with Windows 10 NUC7i5BNHXF

Dell XPS L702X Service Manual

Replacing the Gateway 200ARC Keyboard

Replacing the Gateway M405 Keyboard

Dell Precision Hard Drive Assembly Installation Guide

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

SySTIUM TM TECHNOLOGIES Model 215

Upgrading and Servicing Guide

User Guide for NUC7CJYSAL. Intel NUC 7 Essential, a Mini PC with Windows 10 NUC7CJYSAL. User Guide

User Guide. Intel NUC 8 Enthusiast, a Mini PC with Windows 10 NUC8i7BEKQA. Intel NUC 8 Home, a Mini PC with Windows 10 NUC8i5BEKPA

Dell Latitude Solid State Drive Installation Guide

To connect the AC adapter:

Dell Precision 3430 Small Form Factor

ELECRAFT P3 HIGH-PERFORMANCE PANADAPTER P3SVGA OPTION INSTALLATION AND OPERATING INSTRUCTIONS. Rev B, March 20, 2012

User Guide for NUC7i3DNHNC. Intel NUC7 Business, a Mini PC with Windows 10 NUC7i3DNHNC. User Guide

User Guide. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNKP. Intel NUC 7 Enthusiast, a Mini PC with Windows 10 NUC7i7BNKQ

Upgrading and Servicing Guide

Intel NUC Kit NUC6CAYS User Guide

Release Notes. Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series. Prerequisites. Preparing Your Location

Intel Storage System JBOD2000S3 Product Family

Intel RAID Controller RS3UC080J

Replacement Keyswitch Assembly

Installing the Cisco MDS 9020 Fabric Switch

Upgrading and Servicing Guide

FlexPower Server User Guide

Installation Job Aid for Ethernet Routing Switch 3600 Series

Preparing to Install the VG248

Replacing the Hard Drive on a DVR

Veritas Appliance Hardware Service Procedure

MESOS Storage Series M4600H

Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i3BNHXF. Intel NUC 7 Home, a Mini PC with Windows 10 NUC7i5BNHXF

HP NetServer E 800 Installation Guide

Nvidia Quadro FX 5600 graphics card and auxiliary power adapter cable installation

Installing and Upgrading Memory and Virtual Private Network Modules

Wall-Mounting your HP TouchSmart. User Guide

H3C S12500 Routing Switch Series

Elecraft K3 KREF3 Output Level Modification

Chassis Overview. About the Cisco NCS 4016 Chassis. This chapter provides an overview of the Cisco NCS 4016 chassis and components.

Intel Compute Card User Guide v2.0. Intel Compute Card User Guide

IT ESSENTIALS V. 4.1 Module 2 Safe Lab Procedures and Tool Usage

Installation Job Aid for Ethernet Routing Switch 5900 Series

13 MMC for PC Option Modules

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

IntelliVue MP20/30. Hardware Upgrade Installation Guide. IntelliVue Patient Monitor MP20/30. Patient Monitoring M B *M B*

Chapter 2: Disassembly

Service Manual - Memory Upgrade

Veritas Appliance Hardware Service Procedure

Ollee Ultra Mini PC, a Mini PC with 32GB emmc and Windows 10 Pro MAPMG. Ollee Ultra Mini PC, a Mini PC with 120GB SSD and Windows 10 Pro MAPMG1

PowerLogic ION7300 Series

ELECRAFT K3 HIGH-PERFORMANCE METER TRANSCEIVER K3EXREF FREQUENCY LOCK OPTION INSTALLATION AND OPERATION. Revision A2, October 31, 2012

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Allworx 24x Service and Troubleshooting Guide

Viglen BX110. Chassis Product Guide. G r e a t Minds T h i n k C O M P U T E R S N E T W O R K S S O L U T I O N S

Removal and Installation8

IntelliVue Patient Monitors

Maintaining the ERX System

256 Kbytes (1771-DRS) 1 Mbyte (1771-DRS1) 4 Mbytes (1771-DRS4) Installation Data

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Dell XPS M1530 Service Manual

Gateway Profile 4 service guide

Dell Inspiron XPS and Inspiron 9100 Service Manual

XTM 1050 Replacement Parts Installation

Veritas Appliance Hardware Service Procedure

Metro-Optical Transport Access Nodes

Veritas Appliance Hardware Service Procedure

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

Upgrading and Servicing Guide

SCSI Cable Installation Instructions

Transcription:

Intel Server Board S2600BP Intel Compute Module HNS2600BP Product Family Quick Start Guide for Node Replacement A document providing instruction for the replacement of Intel Compute Modules using an Intel Server Board S2600BP Rev 1.00 Intel Server Products and Solutions

Warnings Heed safety instructions: Before working with your server product, whether you are using this guide or any other resource as a reference, pay close attention to the safety instructions. You must adhere to the assembly instructions in this guide to ensure and maintain compliance with existing product certifications and approvals. Use only the described, regulated components specified in this guide. Use of other products/components will void the UL listing and other regulatory approvals of the product and will most likely result in noncompliance with product regulations in the region(s) in which the product is sold. System power on/off: The power button DOES NOT turn off the Server Chassis AC power. To remove power from the Server Chassis, you must unplug the AC power cord from the wall outlet. Make sure the AC power cord is unplugged before you open the Server Chassis. Power down the Compute Module and remove it from the Server Chassis before performing any integration or service. Remove power feeds from the Server Board. Hazardous conditions, devices and cables: Hazardous electrical conditions may be present on power, telephone, and communication cables. Turn off the Compute Module remove it from the Server Chassis and disconnect all telecommunications systems, networks, and modems attached to the Server Board before servicing it. Otherwise, personal injury or equipment damage can result. Installing or removing jumpers: A jumper is a small plastic encased conductor that slips over two jumper pins. Some jumpers have a small tab on top that you can grip with your fingertips or with a pair of fine needle nosed pliers. If your jumpers do not have such a tab, take care when using needle nosed pliers to remove or install a jumper; grip the narrow sides of the jumper with the pliers, never the wide sides. Gripping the wide sides can damage the contacts inside the jumper, causing intermittent problems with the function controlled by that jumper. Take care to grip with, but not squeeze, the pliers or other tool you use to remove a jumper, or you may bend or break the pins on the board. Electrostatic Discharge (ESD) Electrostatic discharge can cause damage to your computer or the components within it. ESD can occur without the user feeling a shock while working inside the system chassis or while improperly handling electronic devices like processors, memory or other storage devices, and add-in cards. Intel recommends the following steps be taken when performing any procedures described within this document or while performing service to any computer system.

Where available, all system integration and/or service should be performed at a properly equipped ESD workstation. Wear ESD protective gear like a grounded antistatic wrist strap, sole grounders, and/or conductive shoes. Wear an anti-static smock or gown to cover any clothing that may generate an electrostatic charge. Remove all jewelry. Disconnect all power cables and cords before opening the Sever Chassis Power down the Compute Module and remove it from the Server Chassis, remove power feed from the Server Board before performing any integration or service Touch any unpainted metal surface of the chassis before performing any integration or service. Hold all circuit boards and other electronic components by their edges only. After removing electronic devices from the system or from their protective packaging, place them component side up on to a grounded anti-static surface or conductive foam pad. Do not place electronic devices on to the outside of any protective packaging. Caution: Slide/rail mounted equipment is not to be used as a shelf or a work space. Intel warranties that this product will perform to its published specifications. However, all computer systems are inherently subject to unpredictable system behavior under various environmental and other conditions. This product is not intended to be the sole source for any critical data and the user must maintain a verified backup. Failure to do so or to comply with other user notices in the product user guide and specification documents may result in loss of or access to data.

Before You Begin Before working with your server products please confirm that your server nodes are impacted by the issue describe in the Technical Advisory TA-1132. Observe the safety and ESD precautions found in the Warnings section at the beginning of this document. Tools and Supplies Needed Anti-static wrist strap and conductive foam pad (recommended) Phillips* (cross head) screwdriver (#2 bit) Flat Head screwdriver T30 Torx bit screwdriver System Reference All references to left, right, front, and back, assume the reader is facing the front of the compute module, or the side opposite that of the external I/O connectors of the server board.

Compute Module Replacement Procedure 1. Power down the server system by unplugging the AC power cord from the wall outlet. 2. Pull out the impacted nodes from the backside of the chassis. 3. Essential Component Removal of compute nodes. Identify all the components installed on your Intel Compute Node and follow the detailed steps below to remove each of the components 3.1 Air Duct Removal (Intel Compute Module) Please refer to chapter 3.1 in Node Replacement Guide or Chapter 1.1 air duct. 3.2 Processor Removal from Server Board Please refer to chapter 3.2 in Node Replacement Guide or Chapter 5.1 in processor. 3.3 Memory Module (DIMM) Removal Please refer to chapter 3.3 in Node Replacement Guide or Chapter 5.3 in memory. 3.4 Bridge Board Removal (Intel Compute Module) Please refer to chapter 3.4 in Node Replacement Guide or Chapter 5.7 in bridge board. 3.5 Add-in Card Removal (if customer had installed any Add-in cards) Please refer to chapter 3.5 in Node Replacement Guide or Chapter 5.4 in add-in card.

3.6 Intel Remote Management Module 4 Lite Removal (RMM4 Lite) (if customer had installed RMM4 Lite) Please refer to chapter 3.6 in Node Replacement Guide or Chapter 2.2.2 in RMM4 Lite. 3.7 Intel Storage Upgrade Key Removal (if customer had installed storage Upgrade key) Please refer to chapter 3.6 in Node Replacement Guide or Chapter 2.3.2 in Storage Upgrade Key. 4. Essential Component Installation of compute nodes Identify all the components removed from your Intel Compute Node and follow the detailed steps below to install each of the components. 4.1 Processor Assembly and Installation Please refer to chapter 4.1 in Node Replacement Guide or Chapter 1.2 in Processors. 4.2 Memory Module (DIMM) Installation Please refer to chapter 4.2 in Node Replacement Guide or Chapter 1.4 in memory. 4.3 Bridge Board Installation (Intel Compute Module) Please refer to chapter 4.3 in Node Replacement Guide or Chapter 1.5 in Bridge Board. 4.4 Intel Remote Management Module 4 Lite (RMM4 Lite) Installation Please refer to chapter 4.4 in Node Replacement Guide or Chapter 2.2.1 in RMM4 Lite. 4.5 Add-in Card Installation Please refer to chapter 4.5, 4.6 and 4.7 in Node Replacement Guide or Chapter 2.4, 2.5 and 2.6 in S2600BNP_Integration_and_Service_Guide for detail steps of how to install the Add-in card.

4.6 Intel Storage Upgrade Key Installation Please refer to chapter 4.8 in Node Replacement Guide or Chapter 2.3.1 in Storage Update Key. 4.7 Air Duct Installation (Intel Compute Module) Please refer to chapter 4.9 in Node Replacement Guide or Chapter 1.1.2 in Air duct. 5. Pull in the replaced nodes. 6. Insert the power cords, Power down the server system.