High Performance Tension Controller HPTC Electrical Connection Manual

Similar documents
DCA - 10 / DCA TTS Systems

Operating and Maintenance Instructions

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

SX90 Process Controller

SCS AUTOMATION & CONTROL

Genset control and protection with safety system

IQM & IQML RANGE CONTROL AND MONITORING FACILITIES. Publication E420E issue 7/02

Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

Multifunctional time delay relay MFT U31S, MFT U41SE

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Installation, Operation and Maintenance Instructions

PHOENIX CONTACT - 01/2007

MINI MCR-SL-UI-REL(-SP)

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

PQ V ac. CONTROL PANEL 230V FOR ROLLING SHUTTERS Instructions Manual. Control panel for electric rolling shutters 230Vac TECHNICAL FEATURES

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

Manual Control Unit GFC 32

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Content. Time delay relays mounting position. Multifunctional time delay relay Clock-pulse generator time delay relay... 3.

Everything s possible. Modbus Communication. Reference Manual. DigiFlex Performance Servo Drives. MNCMMBRF-02

DEEP SEA ELECTRONICS PLC DSE103 MK II Speed Switch Operators Manual

Installation Instructions

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Power supply CP-C 24/5.0

Standards Update Notice (SUN) Issued: August 11, 2017

ABB industrial drives. Safety instructions ACS880 multidrive cabinets and modules

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

CU port USB 2.0 hub. Version: 1.1 Date:

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual

Installation Instructions

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

Functional data Factory settings Variable Setting Torque Inhibiting torque

MINI MCR-SL-UI-2I(-SP)(-NC)

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

STUDIO 1800 OPERATING INSTRUCTIONS MANUFACTURED IN THE UK

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

The accessory described in this manual is a high quality product that has been carefully designed and manufactured to guarantee optimal performance.

4100 and 4100/R Controllers

SMVector Additional I/O Module Installation and Operation Manual

ACCESS 9340/9360 Meter Input/Output Module

ST (6ES7132-6FD00-0BB1)

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

Manual Simatek Control Unit GFC 32

USER MANUAL. WBI414F21 AC current transducer

MINI MCR-SL-PT100-UI(-SP)(-NC)

Manual Control Unit GFC 16

EM-F-7G Safety Extension Module

USER MANUAL. WBI412F41 AC current transducer

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

Replacement and Calibration of Electronic Spare (PCB) Cassettes - Rosemount 2120 Vibrating Fork Liquid Level Switch

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

Model DPDT Switch Module

Type Quickstart (from device Version 2)

Application program: description and examples

USER MANUAL. WBV412U01 AC voltage transducer

APEX Junior Cased Weighing Indicator/Controller

7-day room temperature controller

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

Controlesta RCO-Compact

SoundwebTM. Installation Guide

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

TU531, TU532 Terminal Unit

Fieldbus Independent I/O Modules 1 AI DMS Manual

ATV32HU40N4 variable speed drive ATV32-4 kw V - 3 phase - with heat sink

Options for ABB drives. User s manual Prevention of unexpected start-up (option +Q957) for ACS880-07/17/37 drives

Installation Instructions

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

PHOENIX CONTACT - 07/2006

Table of Contents. Safety. Attention. Warnings

TECHNICAL MANUAL. Man / Auto. Ten Off / On x100 psi Tension lb X1000 lb 0.

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

POWERDRIVE, PROXIDRIVE, VARMECA

Installation Requirements for Conformance to Standards

Installation Instructions

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

Options for ABB drives, converters and inverters. User s manual FDIO-01 digital I/O extension module

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

CORTEX INDUSTRIAL SYSTEM CONTROLLER Dancer Position Control. Instruction Manual Model CORTEX-C00

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Installation Guide MODELS 522 / 526. Pressure Transducers TOLL FREE FAX Web Site.

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

Compact Universal Controllers

Installing and Configuring Rialto Analytic Appliances

Limit switches for Dial Thermometers and Pressure gauges

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Assembly instruction / User manual

Transcription:

High Performance Tension Controller HPTC Electrical Connection Manual TTS Systems Limited 14, Highpoint Business Village, Henwood, Ashford, Kent, TN24 8DH

Contents Electrical Overview... 3 Power Supply Connections... 4 Analogue Input Functions... 6 Connecting Analogue Inputs... 6 Analogue Output Functions... 9 Digital Input Functions... 11 Digital Output Functions... 14 Load Cell / Dancer Configurations... 17 Connecting Load Cells to V5-940 Module... 17 Connecting Load Cells to Analogue V5-921 Module... 20 General Safety... 21 EMC Regulations... 22 Hazardous Area Operations... 22 Contact Details... 22 2

Electrical Overview Electrical connections to the HPTC vary according to how you wish to use the controller in your application. If you wish to deviate away from the approach we have provided, please contact your systems engineer for further guidance. We strongly recommend that a qualified electrical installer carries out this work. Refer to your installers electrical schematic for application specific wiring detail. The following pages provide information on how to connect the controllers electrically. The minimum wiring required is: A 24 Volt DC Power Supply 3 Digital inputs 1 Analogue input source for the measured value 1 Analogue Output to the actuator, typically an E/P convertor The controller will be in hold mode when C2-1 is low. This permits access to certain parameters that can be only adjusted when the machine is not running. This also allows the analogue outputs to be switched OFF for example during a changeover when the expired reel needs to be free running. A present starting pressure can be applied to the brake which will be present in this mode. The control function will initiate when C2-1 is taken high. In normal use this input is under the control of the machine run relay contact however a manual switch can be used but is not recommended. The controller has two fail safe digital inputs that will need connecting. These may be hard wired to enable these inputs but be aware their functions will be ignored by the controller software. These are C2-2 [ Dead Stop / E-Stop] and C2-3 [Fast Stop / Web Break]. Dead Stop will send a 10V output to the analogue output[s] to put full air pressure onto a brake[s] meaning that the web could potentially break. Fast Stop will apply a percentage output over a period of time to the brake to bring under a more controlled situation such as a web break detection. If these inputs are relay controlled, then the fault must be cleared before the controller will function. 3

Power Supply Connections To power the controller a regulated 24 Volts DC supply rated at 600mA is required. Terminal Function C7-1 +24 Volts DC Regulated C7-2 24 Volts DC Return To power the auxiliary relays a regulated 24 Volts DC supply rated at 200mA is required. This can be powered in parallel with the main supply input as shown in the diagram. Terminal Function C4-1 +24 Volts DC Regulated C4-2 24 Volts DC Return 4

5

Analogue Input Functions External Set point 0...10 Volt DC signal representing the tension / demand value required. This input is only valid when the appropriate parameter in the system screens is set to external. Otherwise the value entered via the keyboard will be used. External Measured Value from Dancer / External Load Cell Source / Auxiliary input Accepts a potentially divided input from a potentiometer in the range 0...10 Volts DC provided the potentiometer has a value no less than 1k Ohm. A suitable supply can be obtained from the load cell excitation output. The wiring should be such that an increase in tension causes an increase in voltage. External Park / Holding Pressure An external potentiometer provides a 0...10 Volt DC signal which is proportional to the pressure required to park the unwind reel. Connecting Analogue Inputs 6

Assignment Terminal Function AE1.1 AE1.2 AE1.3 C3-1(X1) C3-2(X2) C3-3(X3) C3-4(X4) C3-5(X5) C3-6(X6) External Set point input (0..10V) Only connect if required Return for X1 Measured Value from Dancer / External Load Cell Source or Auxiliary input (0..10V) Only connect if required return for X3 External Park / Holding pressure set point (0..10V) Only connect if required return for X5 AE1.4 C3-7(X7) Not used C3-8(X8) return for X7 Not used 7

Connect the 0V of the external analogue signal source to the 0V of the analogue input concerned Connect the signal output of the signal source to the signal input of the analogue input. Always use two, paired terminals of the analogue input to connect a signal to the HPTC-U All auxiliary inputs are rated at 10 Volts DC and are high impedance and so should not load any circuits unnecessarily. It is recommended to use screened cable to limit possible interference If a potentiometer is required for a set point input provided it is a 1 K ohm version this could be supplied by the Load Cell excitation supply, but take care not to create any earth loops 8

Analogue Output Functions There are two analogue outputs provided. One is designated as Channel A and the second designated Channel B. The outputs function differently depending upon the chosen configuration. The analogue outputs provide 0...10 Volts DC at up to 100mA. These signals may be connected directly to a voltage driven actuator or voltage input on a drive. Alternatively, via a separate converter module to drive current driven actuators such as electromagnetic brakes and clutches for example TTS CDM[x] for example will power electromagnetic brakes up to 6 Amps. Connecting Analogue Outputs 9

Assignment Terminal Function AA1.1 C3-9(X9) Analogue output A C3-10(X10) Return for X9 AA1.2 C3-11(X11) Analogue output B C3-12(X12) Return for X11 Analogue Output Assignments Connect the signal input of the load to the signal terminal of the analogue output Connect the 0V of an external analogue load The use of screened lead is advised These analogue outputs can supply 0...10 Volts DC at up to 20mA 10

Digital Input Functions Machine Run: When the machine run contact is open, the integrator function is in park or holding mode. When 24 Volts DC is applied to the Machine Run input the HPTC-U is in control mode. In control mode the PID integrator adjusts the analogue output to a level which maintains the tension set point programmed into the controller. Fast Stop / Dead Stop / Web Break For safety reasons this input must have a signal connected for the controller to work normally. The removal of this input will cause the active channel to immediately go to maximum output and hence apply maximum braking force. The inactive channel will go to the preset park pressure. Removal of this signal will cause the analogue outputs to revert to the condition prior to the signal being applied. If no fast stop / web brake input is required, it must be wired to provide a continuous signal. When used on an unwind two channel application the active channel will be taken to maximum output for the duration the signal is missing from this input, and the inactive channel will have the normal parking pressure applied (the brake release for this channel will be operative). Splice call A pulse of 50mS or longer will, on the +ve edge initiate the splice sequence. See the paragraph Splice Call Logic below for a full explanation of the operation. To perform a changeover from active channel A to active channel B or back again the tension controller must be in synchronization with external equipment, to achieve this in the simplest way the presence or absence of a signal on the channel select input should be made in order to confirm the next channel to be made active (i.e. if channel A is currently in control there should be no signal on the channel select input, but some time before the splice routine is initiated this input should be provided with a 24V DC signal to confirm the next channel to be made active is channel B, which occurs on the leading edge of the signal to the splice call input. Similarly before changing back to channel A the channel select input must be removed before the leading edge of the next splice call pulse). A change from active A to active B will immediately freeze the output of A at the level it was at the exact point of the splice call, this is so that no sudden removal of tension causes a disturbance, at the same instant a timer will be initiated the purpose of which is to automatically inhibit the integral part of the control loop in order to prevent violent oscillations until the changeover is complete, the delay should be adjusted (within the system parameters), to the minimum acceptable. Also at the same instant the next channel to become active will be switched over to PD. control, no ramp times are included as it is important to achieve tension control as soon as possible. At the time determined by the commissioning engineer, after control is transferred the integral part of the control loop is re-enabled. Another timer, will after a short period, reduce (or increase) the last output setting of the now inactive channel to a preset parking pressure. The sequence is now complete and operation continues as normal. 11

Channel select With no signal applied channel A is the default. To select channel B this input should receive a 24V DC signal BEFORE the splice call signal is applied and remain high until the leading edge of the splice call has occurred. Park pressure brake A release Part of the roll change sequence. A 24V DC signal on this input removes the park pressure signal of analogue output A, but only when it is the inactive channel. Park pressure brake B release Performs a similar function to the signal above, but it is for channel B when it is inactive. Connecting Digital Inputs 12

Assignment Terminal Function E1.9 C2.1 Machine Run E1.10 C2.2 Dead Stop / Emergency Stop Must be wired or switched E1.11 C2.3 Fast Stop / Web Break Must be wired or switched E1.12 C2.4 Splice Call E1.13 C2.5 Channel Select (A=open) E1.14 C2.6 Channel A release E1.15 C2.7 Channel B release E1.16 C2.8 Not Implemented C2.9 Common return Digital Input Assignments If isolation is not required it is possible to use the HPTC supply or the output relay supply to feed the digital inputs, in which case the 0V connections need to linked, When connecting digital inputs you should carefully observe EMC precautions. Connect the 0V of an external 24 Volt DC supply with the 0V of the digital inputs The +24 Volt DC supply is connected to one of the digital inputs through the switch The current for each digital input is 6mA. The external signals may be switched using the +24 Volt DC supply as shown in the electrical diagrams The switched signal may be derived using the power supply 13

Digital Output Functions Volt Free Contacts This feature is not currently available on current software Using the facilities that are provided in the Material Manager program up to four outputs may be switched on or off depending upon the menu function selected. An example of where this function may be used is where a larger brake is to be used but where less torque is required therefore pads may be switched out of circuit e.g. this may be used when working with two different grades of paper or film. Connecting Digital Outputs These are Volt free relay contacts, rated at 24 Volts AC / DC @ 1 amp. 14

The HPTC is equipped with four digital relay outputs which are available on C6 as volt free dry contacts. To connect a digital relay output the procedure is:- Connect the 0V of an external 24V DC auxiliary supply with the 0V of the digital output auxiliary supply Connect the +24V of an external 24V DC auxiliary supply with the +24V of the digital output auxiliary supply Connect the load through the potential free contact of the relay output with a DC or AC source. These are only required if using brake pad switching on unwind stands to reduce torque requirement. A useful trick is to feed the 24 Volt DC relay coil supply (C4), via the emergency stop circuit, thus ensuring if the emergency stop is pressed all outputs will be removed, regardless of the state of the program. Connecting Digital Outputs Assignment Terminal Function A1.1 C6-1 Spare C6-2 Return A1.2 C6-3 Spare C6.4 Return A1.3 C6.5 Spare C6.6 Return A1.4 C6.7 Spare C6.8 Return Digital Output Assignments 15

16

Load Cell / Dancer Configurations There are two methods of connecting load cell feedback to the controller. 1. The HPTC may have an integrated load cell amplifier module installed type V5-940. Load cells must conform to full bridge, 350 Ohm, 10 Volt Excitation. 2. The load cell feedback is supplied from an external signal conditioning amplifier is connected to an analogue input. The input should be a calibrated range between 0 to 10 Volts The voltage is connected to terminals C3-3 and C3-4 This option is fitted to all HPTC Controllers Connecting Load Cells to V5-940 Module The external signals may be switched using the +24 Volt DC supply as shown in the electrical diagrams The switched signal may be derived using the power supply Connecting Full Bridge Load Cells 17

Assignment Terminal Function AE1.5 C10-1(Y1) Load Cell 1 [+Excitation supply] C10-2(Y2) Load Cell 1 [Positive input] C10-3(Y3) Load Cell 1 [Negative input] C10-4(Y4) Load Cell 1 [-Excitation supply (0V)] AE1.6 C10-5(Y5) Load Cell 2 [+Excitation supply] C10-6(Y6) Load Cell 2 [Positive input] C10-7(Y7) Load Cell 2 [Negative input] C10-8(Y8) Load Cell 2 [-Excitation supply (0V)] C10-9(Y9) Reserved C10-10(Y10) reserved C10-11(Y11) reserved C10-12(Y12) reserved Full Bridge Load Cell Assignments 18

The amplifier can measure signals of +/-30mV with minimum gain and +/-2mV with maximum gain. The tare adjustment can take away a tare of up to 20mV. The Wheatstone bridge signal conditioning amplifier creates 10 Volts internally. No wrap angle compensation is included as this should be considered when sizing the load cells for the application. It is important the full load output is a reasonably large proportion of the capability of the load cell, small ratios simply reduce the whole system accuracy Please refer to your load cell supplier for colour coding detail 19

Connecting Load Cells to Analogue V5-921 Module To connect a load cell feedback signal please refer to Connecting Analogue Inputs Section 20

General Safety HPTC's are the heart of an automation process therefore particular attention should be paid to the installation and the guidelines contained herein should be followed as closely as possible. Only authorised and suitably qualified personnel should install, setup and commission the controller. The personnel must also be aware of the general safety regulations applying to the application If it is found necessary to open the casing of the HPTC there is a risk of contact with high voltages therefore the entire installation should be isolated before proceeding. Both users and installers should take precautions to ensure that after a power shutdown there is no danger of restarting the system or continuing the interrupted program. Special attention should be given to Emergency Stop circuits, they should be designed with proper care and arranged so the HPTC cannot override the situation. If the installation or environment could be damaged or where there is a danger of personal injury from a malfunctioning HPTC an external parallel safety circuit should be provided. Fuses must only be replaced with the types mentioned in this manual, or if in doubt replace with an identical unit. The earth terminal on the HPTC (C9) should always be properly bonded with the Central Earth Point (CEP) of the installation with wiring of adequate capacity and colour coding. This manual should not be considered as definitive, where queries or contradictions occur it is important to contact the relevant bodies (supplier, Health & Safety Executive etc.), to clarify any uncertain areas. 21

EMC Regulations The HPTC is designed and built in accordance with the EMC guidelines for industrial measuring and operating equipment as applicable in the European Union as from the 1st of January 1996, both for industrial and household applications. To achieve conformity with the EMC regulations the equipment has been tested to the following standards. The compliance with these standards should ensure satisfactory operation in all normal environment. As the Controller will only be one part of an installation the associated equipment and wiring should also confirm to the regulations. EN61000-6-3 EN50082-2 EN61000-4-2 EN50140 and ENV50204 EN61000-4-4 EN61000-4-8 ENV50141 Interfering radiations (Emission) Interference radiation resistance (Immunity) (ESD) Immunity for static discharges. Immunity to Electromagnetic fields Test for fast electrical transit burst Immunity to Strong magnetic fields. Resistance against line related interferences generated by HF fields. Hazardous Area Operations In its existing form the HPTC is not suitable for operation within, or connected to equipment within a hazardous area. If this is required, please contact our help desk and we can advise accordingly. Contact Details Telephone +44 (0) 1233 624422 Fax +44 (0) 870 705 9678 Email Website HPTC Section www.tts-systems.com www.tts-systems.com/products/hptc Current Revision 1.00 Last revised 24 th August 2016 22