TCNM-ACBB1 Installation Manual

Similar documents
FACTORY AUTOMATION MANUAL CBX800

CBX800 INSTALLATION MANUAL

SC4000. Reference Manual

CBX800 INSTALLATION MANUAL

IDENTIFICATION DS4800 APPLICATIONS ADVANTAGES

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

TN-5308 Quick Installation Guide

FLEX Ex Spring Clamp Terminal Base

PTC-101-M12 Hardware Installation Guide

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

8-Port IP40 IEEE802.3af PoE Unmanaged Industrial Switch User s Manual

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

TRC-190 User s Manual

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

IMC-21GA Quick Installation Guide

Industrial Ethernet Switch

MobileView Junction Box

EX-RC1 Remote I/O Adapter

485DRCI. Industrial RS-232 to RS-422/485 Converter B&B ELECTRONICS PRODUCT INFORMATION. Specifications Serial Technology

EDS-G205A-4PoE Hardware Installation Guide

EX-RC1 Remote I/O Adapter

Incremental encoders Solid shaft with clamping or synchro flange pulses per revolution

EX-RC1 Remote I/O Adapter

USER MANUAL. RC-54DL KNET Auxiliary Control Panel MODEL: P/N: Rev 2

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

MS-5000: MiniStar Reader

INJ-24A Series Quick Installation Guide

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

Hardened 4-Port 10/100/1000M DIN-Rail Mount Switch GATB. User's Manual (V1.0 Version)

Moxa Industrial Media Converter PTC-101-M12 Hardware Installation Guide

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.


PTC-101 Quick Installation Guide

PHOENIX CONTACT - 12/2007

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

Junos WebApp Secure 5.0 Hardware Guide

PI-EX-ME-2NAM/COC-24VDC


IMC-21A Quick Installation Guide

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

IMC-21 Quick Installation Guide

FACTORY AUTOMATION MANUAL VB14N BARCODESCANNER

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

MS-7000: SuperStar Reader

PHOENIX CONTACT - 05/2007

Absolute encoders - bus interfaces

1. Safety Precautions (Read these precautions before use.)

MOXA Industrial Media Converter

Common to all H3DS. Installation of Screw-Less Clamp Models. Tools. Applicable Wires. Applicable Screwdriver. Applicable Wire Sizes

Expansion Module HZS 541-1S

Programmable temperature transducer from Pt1000 sensor to current loop 4-20 ma Instruction Manual

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

PI-EX-ME-2NAM/COC-120VAC

CSMIO-MPG. 6-axis Manual Pulse Generator (MPG) Module. Rev copyright 2014 CS-Lab s.c.

RMB Peripheral Units Installation Guide

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

This Datasheet for the IC670GBI002 24VDC BUS INTERFACE UNIT.

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

485DRCI. Industrial RS-232 to RS-422/485 Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

MODEL: R2K-1 SEN TRONIC AG. R2K Series

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

TRC-190 User s Manual

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

Display Panel BAT 100 LSN. en Operation Guide

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

TruPortal Output Expansion Board Quick Reference

ICF-1150 Series Quick Installation Guide

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

MS-3000 MicroStar Reader

EA500. Installation Instructions Transponder

TRANSDUCER T4311, T4411

Rhino PSM Power Supplies. Operating Instructions

A30 QuickStart Guide. Publication # (Rev C)

DS4300 INSTALLATION MANUAL

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

MOXA EtherDevice Switch EDS-205 Hardware Installation Guide

PT-7728/7828 Quick Installation Guide

MGate 5111 Quick Installation Guide

DS2100N. Reference Manual

This guide provides basic information for Unitronics Models V230/260/280/290 (Non-color Screens).

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

Transcription:

The TCNM-ACBB1 is a connection box that can be used as an accessory to facilitate system connections for installation and device replacement of several Banner family reading devices. System cabling is made through spring clamp terminal blocks inside the TCNM-ACBB1 while the reading device is connected to the TCNM-ACBB1through a 25 pin connector on the housing. A 9-pin connector placed inside the TCNM-ACBB1 facilitates connection between an external PC and the auxiliary serial interface of the reading device for configuration or data monitoring. TCNM-ACBB1 can also house an accessory Backup and Restore Module to make system maintenance extremely quick and easy. Sep 2013 p/n 174477 Rev. A

General View 1 Indicator LEDs 2 Cover screws (2) 3 Compression connectors (4) 4 25-pin device connector 1 Power switch (on/off) 2 Auxiliary port connector 3 Mounting holes (2) 4 ID-NET termination resistance switch 5 Indicator LEDs 6 Backup module connector 7 Spring clamp terminal blocks 8 RS485 termination resistance switch 9 Power source selector 10 Shield to protection earth selector 11 Chassis grounding selector Safety Precautions ATTENTION: READ THIS INFORMATION BEFORE INSTALLING THE PRODUCT POWER SUPPLY This product is intended to be installed by Qualified Personnel only. This device is intended to be supplied by a UL Listed NEC Class 2 power source. Total power consumption is given by adding the TCNM-ACBB1 power consumption to that of all the devices powered through the TCNM- ACBB1 (reading device, P.S.,I/O). Refer to the manual of the connected devices for details about minimum/maximum supply voltage and power consumption. Each TCNM-ACBB1 supports only 1 single reading device + system accessories. Supposed Reading Device Models The TCNM-ACBB1 can be connected to the following readers using the 25-pin connector. TCNM-AD TCNM-EX 2 p/n 174477 Rev. A

TXHNM-SP Opening the TCNM-ACBB1 To install the TCNM-ACBB1 or during normal maintenance, it is necessary to open it by unscrewing the two cover screws. Disconnect the TCNM-ACBB1 from the power supply during this operation. Mechanical Installation TCNM-ACBB1 can be mounted to various wooden or plastic surfaces using the two self-threading screws (3.9 x 45 mm) and washers provided in the package. Mounting to other surfaces, such as concrete walls or metallic panels, requires user-supplied parts (screws, screw anchors, nuts, etc). A mounting template is included in the package to facilitate hole drilling alignment. TCNM-ACBB1 can also be mounted to a DIN rail or a Bosch Frame using the mounting accessories. The diagram below gives the overall dimensions of the TCNM-ACBB1 and shows the two mounting through-holes. 3 p/n 174477 Rev. A

Electrical Connections and Setup The following figure shows a typical layout. The dotted line in the figure refers to an optional (temporary) hardware configuration in which a portable PC can be quickly connected to the TCNM-ACBB1 (and consequently to the reading device auxiliary interface) through the internal 9-pin connector. This allows monitoring of the data transmitted by the reading device or configuration through the utility program (see the reading device Installation Manual for more details). The reading device auxiliary interface signals are also available on the internal spring clamp connectors. After making system cabling and switch settings, connect the reading device to the 25-pin connector on the TCNM-ACBB1 housing. Switch ON the TCNM-ACBB1 power switch. The Power LED turns on (blue) when the power connection has the correct polarity. The Power LED turns on (red) in case of wrong polarity. After system functioning has been verified, close the TCNM-ACBB1 using the two cover screws. Power Supply Power is supplied to the TCNM-ACBB1 through the Vdc and GND pins provided on the spring clamp connector. The power switch switches the power supply ON or OFF for both the TCNM-ACBB1 and the connected reading device. The power switch does not control power to the Vdc/GND, +V/-V spring clamps, therefore any devices connected to these signals (i.e. external trigger, encoder, etc.), are live and are not protected from polarity inversion. Disconnect the power supply when working inside the TCNM- ACBB1. 4 p/n 174477 Rev. A

Power Switch ON/OFF Positions and Connections Vdc is electrically connected to +V, just as GND is electrically connected to -V. This is useful for supplying external trigger, inputs and outputs from the TCNM-A CBB1 power source, however +V and -V signals should not be used as power supply inputs to the TCNM-ACBB1. The power supply must be between 10 and 30 Vdc only. System Wiring To avoid electromagnetic interference: - Connect TCNM-ACBB1 Protection Earth (Earth) to a good earth ground. - Connect the reading device chassis to earth ground through the jumper, (default setting). - Connect the Network Cable Shield (Shield) to Filtered Earth through the jumper (default setting). The connection and wiring procedure for TCNM-ACBB1 is described as follows: 1) Open the TCNM-ACBB1 by unscrewing the two cover screws. 2) Verify that the TCNM-ACBB1 power switch is off. 3) Unscrew the compression connectors and pass all the system cables through them into the TCNM-ACBB1 housing. 4) To connect the power and input/output signals: a. Prepare the individual wires of the system cables by stripping the insulation back approximately 1 cm. b. Using a device such as a screwdriver, push down on the lever directly next to the clamp. c. Insert the wire into the clamp and release the lever. The wire will now be held in the spring clamp. 5) Tighten the compression connector nuts so that the internal glands seal around the cables. 5 p/n 174477 Rev. A

System Cable Connections Use flexible stranded wire and meet the following specifications. All positions: 24-16 AWG 0.2-1.5 mm² The TCNM-ACBB1 spring clamp connector pinouts are indicated in the pinout table. Refer to the reading device installation manual for signal details. Pinouts Group Name Function Input Power Vdc Power Supply Input Voltage + External Trigger Input GND Power Supply Input Voltage - Earth Protection Earth Ground V+ Power Source External Trigger I1A I1B External Trigger A (polarity insensitive) External Trigger B (polarity insensitive) -V Power Reference External Trigger Generic Input +V Power Source Inputs I2A I2B Input 2 A (polarity insensitive) Input 2 B (polarity insensitive) -V Power Reference Inputs Outputs +V Power Source Outputs -V Power Reference Outputs O1+ Output 1 + O1- Output 1 - O2+ Output 2 + O2- Output 2 - Auxiliary Interface TX Auxiliary Interface TX RX SGND Auxiliary Interface RX Auxiliary Interface Reference ID-NET REF Network Reference ID+ ID-NET Network + ID- ID-NET Network - Network Shield Network Shield Cable 6 p/n 174477 Rev. A

Main Interface RS232 RS485FD RS485HD TX TX+ RTX+ RTS TX- RTX- RX CTS *RX+ *RX- SGND SGND SGND The input power signals Vdc, GND, and Earth as well as the network signals REF, ID+, ID-, and Shield are repeated to facilitate system cabling. In this way, the power and network busses can enter and exit the TCNM-ACBB1 from different spring clamps but be physically connected together. Power Source Jumper Settings For most applications, input power is provided through the dedicated spring clamp connectors inside the TCNM-ACBB1. However, TCNM-ACBB1 may accept power from the connected reading device through the 25-pin connector. This is useful, for example, to pass power to connected accessories such as Encoder. See the relative reading device Reference Manual for details. To power TCNM-ACBB1 from the reading device, place the power source jumper in the "power from device" position as indicated. Power Source Jumper Settings Shield to Protection Earth Jumper Settings The network cable shield (Shield) can be connected to Earth Ground (Earth) either directly or through a filter circuit. If the jumper is left open, the network cable shield (Shield) is floating. Shield to Protection Earth Jumper Settings Chassis Grounding Jumper Settings Select the reading device chassis grounding method by positioning a jumper. In this way the reading device chassis can be connected to earth ground (only if pin Earth is connected to a good earth ground). 7 p/n 174477 Rev. A

For all reading devices, the chassis can alternatively be connected to the power supply ground signal (GND) or it can be left floating (remove the jumper). Chassis Grounding 9-Pin Reading Device Auxiliary Serial Interface Use the reading device auxiliary serial interface available on the internal TCNM-ACBB1 9-pin connector for configuration or data monitoring. Connect the device to a PC or Laptop using a straight through cable or a USB-RS232 converter. The connector pins are listed in the following table. TCNM-ACBB1 9-pin Female Connector Pinout Pin Name Function 2 TX Auxiliary RS232 3 RX Auxiliary RS232 5 SGND Auxiliary Reference Ground 1, 4, 6, 7, 8, 9 N.C. Network Bus Termination The ID-NET termination resistance switch enables or disables the insertion of the bus termination resistor for ID-NET network applications. ID-NET Termination Resistance Switch In ID-NET network applications, enable the termination resistor (ON) on the first and last devices of the chain. On all the other devices, disable this resistor (OFF). The RS485 HD termination resistance switch enables or disables the insertion of the bus termination resistor for RS485 Half Duplex Multidrop applications. 8 p/n 174477 Rev. A

RS485 HD Termination Resistance Switch In Multiplexer applications, enable the termination resistor (ON) ONLY on the last device of the chain, the farthest away from the Multiplexer (assuming the Multiplexer is the first device of the chain). On all the other devices, disable this resistor (OFF). TCNM-ACBB1 Backup and Restore Module (Accessory) The TCNM-ACBB1 Backup and Restore Module (separate accessory) provides configuration parameter backup. It can easily be installed by aligning it over its corresponding connector in the TCNM-ACBB1 and pushing down until correctly seated. When closed, the plastic support inside the TCNM-ACBB1 cover holds the module in place. For further details see the TCNM-ACBB1 manual. TCNM-ACBB1 Accessory Mounting 9 p/n 174477 Rev. A

Indicator LEDs There are five Indicator LEDs that signal power and I/O activity and are visible from the outside cover. The Power LED is blue when power is correctly applied to the TCNM-ACBB1 and the power switch is turned on. This LED is red if power polarity is incorrect. In this case, the connected reading device and optional Backup Module are protected. If external I/O devices are powered through TCNMACBB1(connected to +V/-V), they are not protected from polarity inversion. The remaining four LEDs signal activity on the relative I/O lines. Their meaning depends on the software configuration of the connected reading device. Specifications Electrical Supply Voltage 10 to 30V dc Consumption 0.5 to 0.3 A User Interface LED Indicators Power ON/Polarity Error (blue/red) Trigger (amber/yellow) IN2 (green) OUT1 (amber/yellow) OUT2 (green) Physical Features Mechanical Dimensions 138 x 128 x 62 mm (5.4 x 5 x 2.4 inches) Limited Current Consumption TCNM-ACBB1 + reading device consumption (see related manual) 2.5 A max. Weight about 380 grams (13.40 ounces) 10 p/n 174477 Rev. A

Environmental Features Operating Temperature 0 to 50 C (+32 to 122 F) Storage Temperature -20 to 70 C (-4 to 158 F) Humidity max. 90% non condensing Vibration Resistance (EN 60068-2-6) 2 hours on each axis 14 mm @ 2 to 10 Hz 1.5 mm @ 13 to 55 Hz 2 g @ 70 to 200 Hz Shock Resistance (EN 60068-2-27) 30 g; 11 ms 3 shocks on each axis Protection Class (EN 60529) IP65 (when compression connectors and reading device are correctly connected) The features given are typical at a 25 C ambient temperature (if not otherwise indicated). * for details about minimum/maximum supply voltage refer to the manual of the connected reading device, since the minimum supply voltage required may be >10. 11 p/n 174477 Rev. A