UPS PRO MODERNÍ DATOVÁ CENTRA Rastislav Smatana AC Power Sales Manager CZ&SK
VERTIV BY THE NUMBERS SALES $4.4B EMPLOYEES ~20,000 CUSTOMERS INCLUDE America Movil, AT&T, China Mobile, Ericsson, Facebook, Nokia, Microsoft, Reliance, Verizon, Vodafone, DTAG, Amazon, Google... Offering Geography End Market 16% 17% 28% 39% Power Mgmt Services Infrastructure Mgmt & Solutions Thermal Mgmt 5% 4% 18% 28% 45% US & Canada Asia Europe Latin America Middle East / Africa 18% 21% 61% Data Centers Communications Commerical & Industrial Broad range of power, thermal, and infrastructure management portfolio Global, well-established footprint and supply-chain network Serve vital applications in data centers, communication networks, and commercial/industrial environments
OUR GLOBAL PRESENCE US and Canada Manuf. and Assembly Locations 13 Service Centers 80+ Service Field Engineers 965+ Technical Support/Response 145+ Customer Experience Centers/Labs 5 WORLDWIDE Manuf. and Assembly Locations 28 Service Centers 255+ Service Field Engineers 3,135+ Technical Support/Response 415+ Customer Experience Centers/Labs 14 Asia Pacific Manuf. and Assembly Locations 5 Service Centers 95+ Service Field Engineers 945+ Technical Support/Response 75+ Customer Experience Centers/Labs 3 Latin America Manuf. and Assembly Locations 1 Service Centers 7 Service Field Engineers 350 Technical Support/Response 60 Customer Experience Centers/Labs 2 Europe, Middle East and Africa Manuf. and Assembly Locations 9 Service Centers 60+ Service Field Engineers 535+ Technical Support/Response 100+ Customer Experience Centers/Labs 4
LIEBERT TRINERGY TM CUBE 150 KW UP TO 3.4 MW Proven track record (>6 year) To evolve our technology to the utmost level To further improve the current Trinergy thanks to customer feedback To offer a real alternative to rotary UPS in very large data centers
LIEBERT TRINERGY TM CUBE MARKET DIFFERENTIATORS Hot scalability Flexible design Circular redundancy Continuous operation up to 55 C Average operating efficiency up to 98.5% 150 kw 3.4 MW in a single UPS system, up to 27 MW in parallel Proven track record: > 400 MW with Liebert Trinergy Cube > 1.2 GW with Trinergy platform
LIEBERT TRINERGY CUBE 150-3400 KW PRODUCT ID CARD Liebert Trinergy Cube Features and Benefits T-free three-level power converter topology, VFI efficiency up to 96.8% VFD efficiency up to 99% and above Dynamic online (VI) efficiency up to 98% and above Average operating efficiency up to 98.5% Up to 3.4 MW in a single unit Up to 27.2 MW in a parallel system Hot scalable: no interruption to the power of the critical load during maintenance or power upgrade Symmetrical output PF up to 1 Circular Redundancy mode for maximum energy saving at partial load Lithium-ion battery compatible Touch screen display as standard Centralized and distributed parallel configurations capability Vertiv TM LIFE TM Services native
LIEBERT TRINERGY TM CUBE ENHANCED EFFICIENCY 1. Neutral point clamped three level inverter 2. DC variable speed fans 3. Up to 96.8% CORE efficiency in VFI 4. Average operating efficiency 98.5% increase the premium efficiency achieved with the current Trinergy TM of an additional 1.5% 5. Reduced heat dissipation reduced cooling requirements 6. Neutral carbon footprint reduced CO 2 emissions are achieved through the savings in energy dissipation Key enhancements: More powerful DSP for increased calculation capability to run the new features/algorithms. Power converter topology (three level T-type) to improve the efficiency of the power train. New mechanical design and cooling for a higher power density. New connection method between the cores and I/O BOX to improve the system flexibility and operation in field. Results: Faster detection and reaction from improved dynamic response. Higher efficiency with regards to the technology used in the current products. Higher footprint Energy-density Trinergy TM Cube 400kW @ 25 C within 675 mm x 910 mm footprint.
LIEBERT TRINERGY TM CUBE THREE FUNCTIONING MODES Maximum Power Control (VFI) > 96.5% Maximum Energy Saving (VFD) > 99% High Efficiency & Power Conditioning (VI) > 98.5% Average operating efficiency: 98.5%
LIEBERT TRINERGY CUBE DYNAMIC ONLINE (VI) VI Mode Class 1 Transfer < 0.5 ms Output Voltages Input Voltages High efficiency and power conditioning: Inverter used as active filter to provide the reactive power Compensates load THDi, PF and voltage sags and swells 98.5% efficiency in typical conditions Class 1 transfer under most stringent conditions: Network fault (voltage variation, high/low impedance mains failures) Load fault (downstream short circuit) Type of load connected (transformer) >50% reduction in yearly operating cost compared to a standard online UPS
LIEBERT TRINERGY CUBE CIRCULAR REDUNDANCY Circular Redundancy UPS load 100% 75% 50% A special logic detects the number of modules needed to supply the load maintaining the redundancy The modules not needed work in a special standby mode that grants the reliability of the system A special algorithm checks that each module operates in standby mode for the same amount of time Same ageing of module components is granted thanks to the auto-detection of operating time of each module
LIEBERT TRINERGY CUBE CIRCULAR REDUNDANCY Circular Redundancy UPS load 25% A special logic detects the number of modules needed to supply the load maintaining the redundancy The modules not needed work in a special standby mode that grants the reliability of the system A special algorithm checks that each module operates in standby mode for the same amount of time Same ageing of module components is granted thanks to the auto-detection of operating time of each module
LIEBERT TRINERGY CUBE PATENTS Uninterruptible Power Supply System with Fast Transfer for Undervoltage Source Line Failures. U.S. Patent Publication: US20140097690 A1 International PCT Pat. App. No. PCT/IB2013/058548 Techniques For Communicating Data Amongst Controllers in a Power Supply System. US patent Publication No.: US-2014-0277810-A1 International PCT Pat. App. No. PCT/IB2014/059766 New Diagnosis Concept for an Uninterruptible Power Supply German patent publication: DE102010044440 A1
LIEBERT TRINERGY TM CUBE THREE DIMENSIONS OF MODULARITY Vertical Modularity: Service 400 kw or 200 kw core while the UPS system continues protecting the load Orthogonal Modularity: Up to 27.2 MW in a parallel system 3.4 MW Horizontal Modularity: Up to 3.4 MW in a single unit 27.2 MW
NEW BATTERY OPTION: LI-ION Li-Ion Key benefits vs VRLA: Footprint and weight reduced by about 70% at the same load power and runtime 10+ years expected life Fast recharge/discharge BMS included as standard Optimized TCO Compact solution Fast recharge High discharge current High energy density Long Expected life 0ºC 40ºC Wide operative Temperature Range
LI-ION BATTERY PRODUCT DESCRIPTION Feature Brand Block Capacity Block Energy Cell type Li-Ion Battery Samsung SDI 67 Ah 2.036 kwh Nickel Manganese Oxide (NMC) Cells per Block 8 Minimum Cell Voltage Max Cell Voltage String Voltage Range Recharge Battery Monitoring System (BMS) Runtime Design Life UPS Compatibility 3.0 V/cell 4.2 V/cell 408 571 V 0.3C (22 Ampere) Included as Standard 5 minutes 15 years Liebert EXL S1 Liebert Trinergy Cube Weight: 545 kg 2055 mm 15
LIEBERT TRINERGY TM CUBE LITHIUM ION COMPATIBILITY Liebert Trinergy Cube can operate with Li-ion batteries thus adapting to all possible requirements in terms of runtime, life expectancy and TCO and showing extreme flexibility. UPS Core Cabinet 136S (17 blocks) - 63Ah 1P 2P 3P 4P 5P 6P 7P 8P Liebert Trinergy Cube PF 0.9 200 kva 8.9 18.8 28.3 37.8 47.2 57.2 66.8 76.3 400 kva N/A 8.9 14 18.8 23.6 28.3 33 37.7 UPS Core Cabinet 136S (17 blocks) - 63Ah 1P 2P 3P 4P 5P 6P 7P 8P Liebert Trinergy Cube PF 1 200 kva 6.6 17 25.5 34 42.5 51 59.5 68.7 400 kva N/A 6.6 12.6 17 21.2 25.5 29.7 34