CableSmart Series Nonmetallic Raceway

Similar documents
With its tamper-resistant design, the

The 5400 Series Raceway from The Wiremold

The 5500 Series from The Wiremold Company

5500 Series Nonmetallic Raceway

WIREMOLD Nonmetallic Raceway

This attractive raceway conceals and

This attractive raceway conceals and

The 400, 800, and 2300 Series, from

This attractive raceway conceals and

The 2400 Series Raceway from

Al uminum Raceway is sleek, clean and

In response to market demand, The Wiremold

This Wiremold aluminum raceway system meets the

2400 & 2400D Series Steel Raceway

AL4400 Series Isoduct Aluminum Raceway

F E A T U R E S & B E N E F I T S. New Tele-Power Pole Extenders make transporting and installing power poles a snap, literally.

WIREMOLD Aluminum Raceway

Vista Point5 Architectural Column

POKE-THRU FINISHES. Black Painted Flange with Nonmetallic Black Cover. Brass Flange with Nonmetallic Brass Cover. Brass Painted Flange and Cover

The 3000 Series Steel Raceway provides wiring capacities for

WIREMOLD. Bring Wire & Cable Down to Business. Tele-Power Poles

F E A T U R E S & B E N E F I T S

Ratchet-Pro Slide Cover

WIREMOLD WMFB Series Floor Boxes

25DTP4DG Tele Power Pole. Features Made in USA. Material, Color, and Finish. Dimensions and Weight

WIREMOLD Steel Raceway

WIREMOLD Tele-Power Poles

3000 Series Raceway shown utilizing data inserts and electrical devices. FEATURES & BENEFITS

25DTP412 12'5" Tele-Powr Pole. Features Made in USA. Material, Color, and Finish. Dimensions and Weight

The Industry Standard In Two-Piece Steel Raceway Available Factory Prewired FEATURES & BENEFITS

Wireless Enclosures from Wiremold/Legrand

Hubbell Metal Raceway HBL6750 Series Product Applications

Bring technology connections to the point-of-use F E A T U R E S & B E N E F I T S

WIREMOLD. innovative wire and cable management

F E A T U R E S & B E N E F I T S

ORTRONICS CLARITY HIGH DENSITY COPPER SOLUTION MAXIMIZE YOUR CABLING DENSITY, REDUCE YOUR FOOTPRINT. designed to be better.

WIREMOLD Steel Raceway

WIREMOLD. Integrating A/V with the Collaborative Space. Meeting Room Solutions

WIREMOLD Table Boxes. Table Boxes bring technology to the point-of-use

Hubbell Metal Raceway HBL3000 Series Product Applications

PHYSICAL INFRASTRUCTURE QUICK SKU FINDER

Power/Data Instructions. Genius. Movable Walls. September

6000 Series Steel Raceway

WIREMOLD. Two-Piece Steel Surface Raceway. Steel Raceway

Steel Plugmold Multioutlet Systems

Interconnect Product CATALOG Q700

WIREMOLD. Evolution Series Wall Boxes. Evolution Series Wall Boxes. New work and old work applications

SM (SURFACE MOUNTED) WIREWAY: I SERIES

68-HP Floor Box. Universal 3-Gang Design Provides Superior Capacity and Mounting Flexibility

Cat.6/5e UTP Patch Panels with 45 Jack

WIREMOLD Meeting Room Solutions

TELEPHONE FLUSH WALL PLATE

ORTRONICS SNAP CLARITY TERMINATED COPPER CABLING SYSTEMS & PORT REPLICATION. designed to be better.

BUILDING NETWORK SOLUTIONS GUIDE

Evolution Series Floor Boxes. Raised Floors Concrete Floors Wood Floors. n Durable 180

Haworth Power Technical Sheets January 2018

Tarleton State University. Specifications

WORK AREA OUTLETS WORK AREA OUTLETS. Work Area Outlets

A. System design shall be completed by a Registered Communications Distribution Designer (RCDD).

FPT4 Series Poke-Through: 2 Power and 6 Communications

4000 Series. Two-Piece Steel Surface Raceway Available Factory Prewired. Steel Raceway

M204SMB Surface Mount Box Instructions

COMPUTER NETWORK WIRING SYSTEMS FOR PLCs

U-SERIES SPECIFICATION GUIDE

Electrical Accessories

Category 5e Solutions

UNDERCARPET CABLING SYSTEM For Power and Communications

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

Siemon PON Fiber Cabling Solutions

9/27/04 cci Cablecom Inc. 1

UNSHIELDED TWISTED PAIR and FOILED TWISTED PAIR SOLUTIONS for the WORK AREA

F E A T U R E S & B E N E F I T S. ED1652 August 2011 For latest specs visit

Compact Module. Category 6 UTP Cabling System

A Complete Floor Box System for Concrete

B Y R N E 8 - T R A C O V E R V I E W. 1) Introduction. 2) Universally Recognized. 3) Circuitry/Keying

Cabling Infrastructure

Government of Prince Edward Island Structured Cabling Standards August 24, 2009

ORIGINAL CABLE PLATES

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version

Installing the ILC LightSync 4.3 or 7 Touch Screen Station. Rev. B

TIA/EIA 568A Sub-system HORIZONTAL CABLING

Termination for 568A and 568B pin configurations.

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA

Privacy Wall - Power & Data Box (Field Installed) Modular & Hardwire Versions

DATACOM CABINETS SOLUTION GUIDE

Pop-Up Number(s) : to 03, to 08, to 13,

Standard Configuration - 4) 15 amp power receptacles 1) Cutout for configurable telecom plates. Door Finishes - UL Listed

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

2015 ECA TELECOM OPTIONS REVIEW

Copper. Patch Panels COPPER CONNECTIVITY. pg. 40. Clarity 10G Patch Panels. Clarity. Patch Panels. Special Application. Patch Panels.

Computer Network Design Guide Existing Systems 1 / 6

PRODUCT BROCHURE. Steel City 665-AV2 floor box 2" KOs for audiovisual applications pull preterminated AV cables through conduit

UMass Lowell. October 1, Network and Voice Infrastructure Specifications Prepared by Network Engineering and Network Project Management

Ethernet Media. Technical Data. Cable Spools 2. Cordsets & Patchcords 5. Patchcords & Field Attachables 10

Modular Connectors 75

SNAP Compact Fiber Optic Patch Panel

Compact Module. Enhanced Category 5 UTP Cabling System

Distribution Devices - Outlets, Jacks, & Plates

ZoneMaster Series Surge Protection Devices

Ground Power Modules. And Accessories For Healthcare Facilities. Technical Bulletin NAE /

Transcription:

CableSmart Series Nonmetallic Raceway Dual-Channel 40N2 Series Nonmetallic Raceway System FIBER OPTIC CAT5 Wiremold CableSmart 40N2 Series Raceway is a large capacity nonmetallic raceway system that offers separate channels for power and communications cabling within a single cover. With its tamper-resistant design, the 40N2 Series Raceway is an ideal solution for schools, office settings, or any installation where greater security is a requirement. 40N2 Series Raceway featuring 40N2F31 Device Bracket. F E A T U R E S & B E N E F I T S n Extremely tamper-resistant. Perfect for school applications or anywhere additional security is a priority. n 2" [51mm] bend radius compliant fittings. These fittings snap onto overlap raceway base and cover for an aesthetic installation. Fittings are culus verified for a 2" [51mm] bend radius and exceed the recommendations of TIA/EIA-569. They provide cable protection in lay-in and pull-through cable installations. n Available prewired. Manufactured to job site lengths, raceway comes completely prewired, ready to install. Jobs can be packaged by area, floor, or building and shipped per job site requirements. n Electrical device identification for prewired jobs. Eliminates guesswork and circuit tracking to speed additions and renovations. n Pre-punched mounting holes. Faster and easier installation. n Ivory and white finish. Blends with any decor. Paintable using latex paint. n New transition fitting options. Used to transition to PN03, PN05 and PN10 Series Latching Raceways. n Made of PVC material. Lightweight and easy to cut. n High capacity device box options. 40N2F55 C-Box allows both power and data devices to be installed in the power channel, greatly increasing cable fill capacity for data cabling. n Corner drop feed. Provides solution for feeding horizontal runs of raceway. n Datacom connectivity options. Accepts industry standard and proprietary devices from a wide range of manufacturers to provide a seamless and aesthetically pleasing interface for voice, data, audio, and video applications at the point of use. n UL and cul Listed component raceways. File E90378 Guide RJTX, Fittings: File E90377 Guide RJYT. Meets Article 388 of NEC and meets Section 12-600 of CEC. ED1146R8 Updated August 2009 For latest specs visit www.wiremold.com

40N2 Series Raceway System Layout 40N2F05 40N2F20 40N2F17 40N2B08 40N2C08 40N2F19 40N2F14 40N2F15 40N2F21 40N2F06 40N2F31 40N2F31 PSB1 40N2F11 NOTE: Illustration is for showing product applications only. 40N2 RACEWAY WIRE FILL CAPACITIES FOR POWER 40N2 Series Raceway Wire Fill Capacities NUMBER OF MAX. NUMBER OF WIRE SIZE O.D. CONDUCTORS CONDUCTORS BOTH THHN/THWN Inches [mm] Comp. A Comp. B COMPARTMENTS Power 14 AWG 0.111 [2.8] 20 20 28 Wiring 12 AWG 0.130 [3.3] 18 18 36 With or 10 AWG 0.164 [4.2] 17 17 24 Without 8 AWG 0.216 [5.5] 15 15 20 Devices 6 AWG 0.254 [6.5] 5 5 10 40N2 RACEWAY WIRE FILL CAPACITIES FOR DATA/COMMUNICATIONS CABLE CATEGORY/ O.D. Section C Section D TYPE DESIGNATION Inches [mm] 40% Fill* 40% Fill* UNSHIELDED 4-pair, 24 AWG Cat 3 0.190 [4.8] 45 24 TWISTED PAIR 4-pair, 24 AWG Cat 5e 0.210 [5.3] 37 19 4-pair, 24 AWG Cat 6 0.250 [6.3] 26 13 4-pair, 24 AWG Cat 6a** 0.354 [9.0] 13 6 25-pair, 24 AWG 0.410 [10.4] 9 5 COAXIAL RG6/U 0.270 [6.9] 22 11 FIBER ZipCord 0.118 x 0.236 [3 x 6] 103 55 Round 4 Strand 0.187 [4.8] 46 24 Round 6 Strand 0.256 [6.5] 25 13 * 40% cable fill is the maximum designed cable fill based on TIA/EIA 569-A. ** Category 6 augmented (6a) cable for 10 gigabit ethernet max allowed cable diameter per addenda No. 11 ANSI TIA/EIA 568-B.2. Section A 3.22 in. 2 [2080mm 2 ] Section B 1.71 in. 2 [1100mm 2 ] 4.0" [102mm] 2.0" [51mm] Section C 3.22 in. 2 [2080mm 2 ] Section D 1.71 in. 2 [1100mm 2 ] 2

40N2 Series Raceway Profile 40N2B08* 2" Two- Compartment Base [51mm] 8' [2.45m] 4" [102mm] Two equal compartments. Use with 40N2 Cover only. 40N2B08 available in 8' [2.4m] lengths with pre-punched mounting holes. *Add V suffix for Ivory finish or WH suffix for White finish. 40N2C08* 8' [2.45m] 1/2" [12.7mm] 2 3/16" [56mm] Full Width Cover Use with 40N2B08 Base. 40N2C08 available in 8' [2.4m] lengths. 40N2 Series Raceway Fittings 40N2FWC 2 5/8" [67mm] Wire Clip Used to retain cables in raceway during installation. 40N2F15* 8 9/16" [217mm] 2" [51mm] Bend Radius Full Capacity Tee Branches raceway at right angles. Provides separation of services and 2" [51mm] full capacity bend radius control for UTP and fiber optic installations. 40N2F05* 5/8" [15.9mm] 40N2F06* Base Clip Covers seam where two lengths of 40N2B08 Raceway Base come together. Cover Clip Covers seam where lengths of 40N2C08 Cover come together. 12 15/16" [329mm] 40N2F17* 4 1/2" [114mm] 2" [51mm] Bend Radius Full Capacity Internal Elbow 90 internal corner with integral dividers. Provides 2" [51mm] full capacity bend radius controlfor UTP and fiber optic installations. Ideal for lay-in or pull-through installations. 40N2F11* 6 5/8" [168mm] 5/8" [15.9mm] 2" [51mm] Bend Radius Full Capacity Flat Elbow 90 flat corner with integral dividers to provide 2" [51mm] full capacity bend radius control for UTP and fiber optic installations. Ideal for lay-in or pull-through installations. *Add V suffix for Ivory finish or WH suffix for White finish. 40N2F19* 4 1/2" [114mm] 40N2F20* 2 11/16" [68mm] 11/16" [17.5mm] 2" [51mm] Bend Radius Full Capacity External Elbow 90 external corner with integral dividers. Provides 2" [51mm] full cpacity bend radius for UTP and fiber optic installations. Ideal for lay-in or pull-through applications. Blank End Fitting Closes off runs of CableSmart 40N2 Series Raceway. Can be used to feed raceway using 1/2" or 3/4" trade size conduit. Holes for conduit must be drilled. 3

40N2 Series Raceway Fittings 40N2F21* Divided Entrance End Fitting Divided fitting to feed 40N2 Series 6" [152mm] Raceway. Includes 3/4", 1", 1 1/4", and 1 1/2" trade size KOs on back and top. 40N2F55 6 3/8" [162mm] 1 3/16" [30mm] High Capacity Device Box Required for mounting power or datacom devices into a divided raceway application. Use one per device location. 40N2F31* 7 5/16" [186mm] 2 3/16" [56mm] 5 1/4" [133mm] NOTE: CM-EPLA End Plates are required when using Wiremold communication modules and Pass & Seymour inserts. S2-EPL End Plates are required when using Ortronics Series II inserts. To mount Tracjack inserts, use 5507-4TJ or 5507-6TJ Faceplates. Twin Cover Device Bracket Use for power or communications devices in a single compartment. Accepts 5507 Series Faceplates. For use with: Ortronics TracJack Individual Jack System, Ortronics Series II Front-Loading, Module System, Pass & Seymour Activate Series Front-Loading Inserts, and Wiremold CM2 Series Open System Communication Modules. 40N2F74* 2 15/16" [74mm] 6 1/8" [156mm] Divided Transition Fitting Makes transition from 40N2 Series Raceway to PN03, PN05, and PN10 Series Raceways. *Add V suffix for Ivory finish or WH suffix for White finish. TRANSITION FITTINGS TO EXISTING WIRING OR OTHER WIREMOLD RACEWAYS CONNECTION REQUIRED FROM TO CAT. NO. 1/2" or 3/4" trade size conduit 40N2 40N2F20 or armored cable 3/4", 1", 1 1/4" & 1 1/2" 40N2 40N2F21 trade size conduit or armored cable 40N2 Series Raceway PN03, PN05, 40N2F74 PN10, PN20 4

5507 Series Faceplates 5507AD* Modular Furniture Adapter Mounts Activate modular furniture bezels and other modular furniture adapters. Not for use with rectangular (decorator) style devices. 5507B* Blank Faceplate Covers unused compartments in device brackets. 5507FRJ* 5507-4TJ* Flush Dual RJ11/RJ45 Faceplate Same as 5507RJ except the connectors are recessed to provide a flush installation. Ortronics Faceplate Mounts Ortronics datacom inserts. Accepts four Ortronics TracJack Devices. 5507D* Duplex Faceplate Covers duplex style devices. Accepts 106 Frame. 5507-6TJ* Ortronics Faceplate Mounts Ortronics datacom inserts. Accepts six Ortronics TracJack Devices. 5507R* Rectangular Faceplate Covers rectangular style devices. 5507S* Rectangular Spacer Mounts commercial device plates. Installs between the device bracket and the device. 5507SW* Switch Faceplate Covers standard toggle switches. 5507T1* Single Receptacle Faceplate Covers single receptacles 1.59" [40.4mm] diameter. 5507T2* Single Receptacle Faceplate Covers single receptacles 1.41" [35.8mm] diameter. 5507RJ* Dual RJ11/RJ45 Connector Faceplate Mounts one or two RJ keystone type connectors has one opening and a KO for the other. CM-EPLA* S2-EPL* CM-ARA* ARA-S2* End Plates Includes two outlet identification labels with clear covers and two matching screw covers. Required for mounting Pass & Seymour Activate and Wiremold CM2 Series Open System communication modules into 40N2 Series device brackets. End Plates Includes two outlet identification labels with clear covers and two matching screw covers. Required for mounting Ortronics Series II modules into 40N2 Series device brackets. Angled Raceway Adapter For use with multi-channel raceway device brackets and WallSource device mounting brackets. Angled exit provides additional mounting depth required for A/V connections as well as ensuring the required bend radius for UTP and fiber optic cabling. Holds two CM2 Series modules or two Pass & Seymour 2A inserts. Fits 5507 Series Faceplate opening. Angled Raceway Adapter For use with multi-channel raceway device brackets and WallSource device mounting brackets. Angled exit provides additional mounting depth required for A/V connections as well as ensuring the required bend radius for UTP and fiber optic cabling. Holds two Ortronics Series II modules.fits 5507 Series Faceplate opening. NOTE: All face plates have a standard measurement of 4 1/4" x 1 7/8" [108mm x 34mm]. * Add V suffix for Ivory finish or WH suffix for White finish. 5

NOTES 6

NOTES 7

DATACOM CONNECTIVITY OPTIONS Now you have a wide range of options for providing datacom connectivity into Wiremold/Legrand Pathways. They are: Ortronics TracJack and Series II Modular Connectivity Solutions Pass & Seymour Activate Modular Inserts Open System Communication Modules Ortronics Connectivity TracJack Individual Jack System Front-loading, snap-in design supports future moves adds and changes Inserts for voice, data, audio, and video Available Category 3, 5e, 6, USOC 6-position, and other media Flat or angled 45 exit configurations Choice of 13 colors and color matched to Wiremold Systems Universal T568A/B wiring format Series II Front-Loading, Module System Module design features easy snap-in front-loading design Linear 110 punch down format for easy termination Inserts for voice, data, audio, and video Available Category 3, 5e, 6, USOC 6-position, and other media Available in flat or angled 45 exit configurations Color matched to Wiremold Systems For detailed product selection refer to the Ortronics Catalog or visit www.ortronics.com. Pass & Seymour Legrand Network Wiring Activate Series Front-Loading Inserts Modular inserts for voice, data, audio and video applications Front-load, snap-in design Color and texture matched to Wiremold Systems Available Category 3, 5e, 6, as well as 6-position USOC Universal T568A/B wiring format For detailed product selection refer to the Pass & Seymour Network Wiring Catalog or visit www.passandseymour.com. Open Connectivity Solutions Wiremold Open System Communications Modules Accommodate a wide range of manufacturers communications outlets including keystone jacks, as well as proprietary solutions from Avaya (Systimax) and NORDX Modules insert into a wide range of Wiremold Systems Pre-punched faceplates accept common communication devices NOTE: For more information on integrating connectivity into Wiremold Cable Management Systems contact the Wiremold Applications Engineering Team or your local Wiremold Sales Representative. Wiremold/Legrand U.S. and International: 60 Woodlawn Street West Hartford, CT 06110 1-800-621-0049 FAX 860-232-2062 Outside U.S. 860-233-6251 Canada: 570 Applewood Crescent Vaughan, Ontario L4K 4B4 1-800-723-5175 FAX 905-738-9721 Copyright 2009 Wiremold/Legrand All Rights Reserved ED1146R8 Updated August 2009 For latest specs visit www.wiremold.com