Siprotec 7ST61 / 7ST63

Similar documents
SIPROTEC. Numerical Overhead Contact Line Protection for AC Traction Power Supply 7ST6. Preface. Introduction 1. Functions 2

Perfect protection smallest space

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

Perfect protection smallest space

SIPROTEC 5 Application Note

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

Sicat CMS. Features. Catenary monitoring system for overhead contact line systems. siemens.com/rail-electrification

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

Products for digital substations SIPROTEC 6MU805. Merging Unit for conventional instrument transformer. Integrated PRP, HSR. siemens.

Protection relays.

SIPROTEC 4 7SD61 Differential Protection Relay for Two Line Ends

Bus Bar Protection Relay B-PRO 4000

Relays for Various Protection Applications / 7SV600

Substation Automation Products. Line differential protection RED670 Relion 670 series

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Feeder protection relay SPAA 121 C. Product Guide

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

SIPROTEC easy 7SJ45 Numerical Overcurrent Protection Relay Powered by CTs

XE2 DC current relay for loss of excitation protection. Manual XE2 (Revision A)

Sicat CMS. siemens.com/mobility. Catenary monitoring system for overhead contact line systems

SIPROTEC 4 7SJ64 Multifunction Protection Relay with Synchronization

Product Families and Positioning. Protection Portfolio

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

XU1-DC DC voltage relay. (June 1998) Manual XU1-DC (Revision New)

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

SIPROTEC 4 6MD66 High-Voltage Bay Control Unit

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

SIPROTEC 4 7SA522 Distance Protection Relay for Transmission Lines

XG2 Generator-/Mains Monitor. Manual XG2 (Revision A)

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

02/11/2015

SIPROTEC 5 V7.8 Protection, automation and monitoring for digital substations

SIMOCODE 3UF Motor Management and Control Devices

GE Multilin 350 Feeder Protection Relay Specifications

XU1-E Earth fault voltage relay. (August 1996) Manual XU1-E (Revision New)

SIPROTEC Compact Overcurrent Protection 7SJ81 for Low-Power CT and VT Applications

Numerical motor protection in medium voltage networks Motor Protection and Control REM620

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

Accessories / 7XV5662

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

DGBV-EP DIGITAL GENERATOR AND GENERATOR-TRANSFORMER UNIT PROTECTION. Field of application

Feeder/ Motor Protection Relay VAMP 40

Synchro-check relay. Application

MiCOM P521. Fast feeder differential protection

MiCOM P122C Time-Overcurrent Protection

SIPROTEC 7SV600 Numerical Circuit-Breaker Failure Protection Relay

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

BN1-400 Mains decoupling relay. (February 2000) Manual BN1-400 (Revision New)

Earth-fault Relay SPAJ 110 C. Product Guide

SIPROTEC 7SC805. Merging Unit for conventional instrument transformer. Products for digital substations.

MiCOM P521. Fast Feeder Differential Protection

SENTRON 3VL Molded Case Circuit Breakers

SIPROTEC 5 Application Note. Breaker-and-a-half solutions. SIP5-APN-002, Edition 2.

Transformer Protection Relay

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

Content REF615 Technical Presentation

Relion 615 series Feeder Protection and Control REF615 Ver. 2.0 Technical Presentation

GPM500 Generator Protection Module

Substation Automation Products. Line distance protection REL670/650 Relion 670 and 650 series

SIPROTEC 4 7SS52 Distributed Numerical Busbar and Breaker Failure Protection

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

IRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)

NPW800R RETROFITTING. Power and Volatge Protection Relay

SIPROTEC 4 7SD52/53 Multi-End Differential and Distance Protection in One Relay

5SL Miniature Circuit Breakers

PHOENIX CONTACT Features

Protection Relays PHASE & RESIDUAL OVERCURRENT

Substation Automation Products. High impedance differential busbar protection REB650 Relion 650 series

EDR-3000 Eaton Distribution Relay

MiCOM P521. Fast Feeder Differential Protection. Protection Relays. MiCOM P521 CUSTOMER BENEFITS

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

Configuration and Interoperability Guide for IEC for the SEL-751 Feeder Protection Relay. July 10, 2015

Advanced Line Differential Protection, Automation, and Control System. Combine subcycle line protection with traveling-wave fault locating

EDR-3000 Eaton Distribution Relay

SACE Emax 2 Specification guide

Substation Automation Products. Transformer protection RET670/650 Relion 670 and 650 series

ACOS 300. Reliable protection for network and constructions in medium- and high voltage

SIPROTEC 5 Application Note

CSP1-L Cable and Line Differential Protection System Performance and functional outline

Miniature Circuit Breakers for Railway Applications

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Contact protection relay

Modular Two-Wire Telecontrol System

Microprocessor protection and automation devices

e 2 TANGO -400 Overcurrent Relay K Catalogue EN

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

Generator Protection. Page

7SR242 Duobias Multi-Function 2-Winding Transformer Protection Relay

3 Pole Contactors with AC operating coils

Application Notes on Generator Protection Schemes

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

FP-5000 Feeder Protection

Substation Automation Products. Generator protection REG670/650 Relion 670 and 650 series

Feeder protection relay SPAA 341 C. Product Guide

SIPROTEC 5 Application Note

PRON NA60-CBA. IEC Communication Protocol User Guide PRON NA60-CBA. Version Page: 1 of 13 PRON NA60-CBA IEC

Siemens Vacuum Recloser 3AD. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SITOP in the SIMATIC Design

Transcription:

Siprotec / Numerical overhead contact line protection for AC traction power supply siemens.de/rail-electrification The numerical overhead contact line protection relay Siprotec / is a selective and quick responding protection device for overhead contact lines fed from one or multiple points in AC traction power supplies. The relay possesses all functions required to protect a section of the overhead contact line and can therefore be deployed universally. Features Integration of protection, control, measurement and automation functions into a single unit Shortest tripping times due to adaptive protection algorithms Efficient operation due to a universal tool for all tasks Adaptation to different modes by parameter-set switchover Flexible availability of all common communication protocols

Overview The Siprotec / numerical overhead contact line protection relay is a member of the Siprotec product family, which stands for excellent quality and powerful protection relays and is characterized by the following features: Powerful 3-bit microprocessor system Completely numerical data processing and control, from the measurement of voltages and currents to the switching decision logic of the circuit-breaker Complete galvanic and interference-immune isolation of the internal processing circuitry from the measurement, control and power supply circuits of the switchgear via measured value trans formers, binary input and output modules, and DC and AC voltage converters Simple operation via integrated operator panel or connected personal computer with operating software Digsi Storage of fault indications and instantaneous values for fault recording An integrated equipment concept arises from integration into the Siprotec family, e. g. with line, transformer and busbar differential protection. The Siprotec / protection relays offer the following basic functions as standard: Distance protection Time overcurrent protection Emergency time overcurrent protection Thermal overload protection Defrosting protection (depending on product version) Trip circuit supervision Control function (Standard for ) Monitoring functions CFC (Continuous Function Chart) for implementation of user defined functions (Standard for ) In addition to these, the following functions are available as options: High-speed overcurrent protection Voltage protection Circuit-breaker failure protection Inrush restraint Automatic reclosure function Synchronism and voltage check Fault locator (even for fast tripping) Calculation of the circuit-breaker load Teleprotectionz 1 5 6 3 7 8 Siprotec combined protection and control unit 1 Indiviudal parameterizable LEDs for display of any process or device information RS3 operator interface 3 Keyswitch for switching between local and remote control and between interlocked and non-interlocked operation Illuminated LC display 5 Navigation keys 6 Keys for control of the switching devices 7 Numerical operating keys 8 Four individual programmable function keys

Basic functions Distance protection (1) Distance protection function with three zones, high measuring accuracy, and flexible options for adaptation to power system conditions Impedance characteristic combined or polygonal The direction characteristics forward, reverse and non-directional can be set for each distance zone Characteristics with separate setting of reach ( impedance Z or reactance X), angle and load delimitation ( resistance R) Instantaneous tripping when switching onto a fault Control functions Closing and opening of switching devices manually via local control keys (), programmable function keys, via the system interface (e. g. station control system Sitras SCS or IEC 61850) or via the operator interface (by means of personal computer and Digsi operator program) Feedback of the switching states via the CB auxiliary contacts (for commands with feedback) Plausibility monitoring of circuit-breaker positions and interlocking conditions for switching Time overcurrent protection (50/51) Full-value, non-directional overcurrent-time protection (definite/inverse-time) in three stages (very high current I>>>, high current I>>, overcurrent I>) Fast tripping when switching onto a fault Emergency time overcurrent protection (51) Back-up protection upon measuring voltage failure Single-stage back-up overcurrent-time protection (I> DMT) Instantaneous tripping when switching onto a fault Thermal overload protection (9) Overhead line temperature calculated by means of a thermal model of the object being protected Catenary switchover Adjustable thermal warning stage Ambient temperature measurement possible Defrosting protection (87) (depending on product version) Differential protection for de-icing current with parameterizable characteristic Back-up protection with two-level definite-time characteristic Trip circuit supervision (7TC) Integrated trip circuit supervision Monitoring functions Monitoring of internal measuring circuits, the auxiliary power supply and the hardware and software, thus increasing reliability Monitoring of the signal of the overhead line voltage (fuse failure monitoring) Monitoring of ambient temperature sensing Monitoring of the tripping circuit possible Display of the operational impedances and direction User defined functions Freely programmable combinations of internal and external signals to implement user-definable logic functions in CFC All common logic functions Delay times and limit queries Further functions Battery-backed clock that can be synchronized via the synchronization signal (DCF 77, IRIG B by means of satellite receiver), binary input or system interface Constant calculation and indication of the operating measurements on the front display Writing of all parameters into a non-volatile memory so the setting values are retained even in the event of auxiliary power failure Fault value storage for the last eight power system faults (fault in the network), with real-time assignment Event store for storing the last 00 operational and 80 fault indications Communication with the control system possible via serial interfaces (depending on order variant), or optionally via data line, modem, or fiber-optic cable Commissioning aids such as connection and direction check and circuit-breaker check 3

Optional functions High-speed overcurrent protection (50HS) Shortest tripping times (< ms) on exceeding tripping threshold Fault current tripping possible already in the first zero crossing of the current (in 16.7 Hz power systems) Voltage protection (7/59) Two overvoltage stages for the overhead contact line ( U>>, U> ) Two undervoltage stages for the overhead contact line ( U<<, U<) Circuit-breaker failure protection (50BF) With independent current levels for monitoring the current flow Tripping by two independent, settable monitoring time levels Starting by tripping command of each integrated protection function External starting possible Inrush restraint Distinction between operation and fault by means of harmonic analysis With blocking option for certain protection functions Distance protection (from zone Z) Overcurrent-time protection and emergency definitetime tripping Au tomatic reclosure function (79) Single or multiple reclosing (up to eight shots) With separate dead and operative times for the first two shots Testing of synchronism before reclosing (in combination with synchronism and voltage check function) Synchronism and voltage check (5) Check of synchronous conditions before connection Alternatively check of absence of voltage before connection Fast measurement of voltage U diff, of phase-angle difference ϕ diff, and frequency difference f diff Switching on asynchronous power system conditions with advance calculation of synchronization instant possible Settable minimum and maximum voltage Check of synchronous conditions or absence of voltage even before planned closure of the circuit-breaker possible Fault location Calculation of fault location upon tripping, release of starting or high-speed tripping Output of the fault location as linear data (kilometers, miles, % of line length) or impedance data (Ω) New technology ALM (Advanced location modelling) also enables fault location in systems with autotransformers Calculation of the circuit-breaker load Measurement and summation of the interrupted currents Monitoring with current-time function and logging of current-time integrals and short-circuit data Load-depending calculation of circuit-breaker maintenance based on the operating cycle diagram Alarm indication on limit violation Further functions Switching statistics: counting of the tripping and closing commands initiated by the device Teleprotection: information exchange with opposite line-end to increase selectivity Communication Four serial interfaces are available for communication with external operating and control systems. Operator interface (front side) Service interface System interface Interface for time synchronization Communication interface Connections Protocols (System interface) RS3; RS85; fibre optic; Ethernet (electrical / optical) IEC 61850, Ed. 1 and Ed. IEC 60870-5-103, Profibus FMS/DP, Modbus, DNP 3.0

Operation Siprotec 7ST6 can be operated via the operator panel on the front of the unit the Digsi user interface of your PC connected locally to the operator interface or via modem to the service interface of the relay the Web Interface at option IEC 61850 Siprotec 7ST6 operator panel Routine operator actions can be performed while using the on ergonomic principles designed operator panel as well as settings of individual parameters and display information required for network management and general diagnostics can be made. Depending on the version, the operator panel of the relay can be arranged as a -line display or a graphic display. Digsi operating and diagnostics software on PC Digsi can be used for easy parameterization and operation of the Siprotec devices on a PC. Digsi uses Windows techniques familiar from other applications for operator guidance. So the operator is working in a familiar system environment. On the user interface only device-specific relevant parameters are offered during configuration and routine operation. Numerous tools, such as context menus, dropdown lists for selection, permissible parameters, limit setting for digital values, and tooltips make an easy parameterization of the Siprotec devices possible. Web Interface With the option for the protocol IEC 61850 there comes a Web Interface for operation. This Web Interface interacts fully with the devices. Additional functions that are available via the Web Interface: Polling errors, messages, logs Downloading fault-reports Display current measured values And much more... Operator panels of Siprotec protection relay (top) and Siprotec combined protection / control unit (cutaway, bottom) Fault display with diagnostic software Sigra 5

Application area AC 5 kv; 50 Hz -Q1 -T15 -Q0 -T1 Siprotec 1 7 9 50 50BF 51 59 7TC 79 Typical configuration of an AC contact line feeder with a numerical overhead contact line protection relay (contains optional functions) AC x 5 kv; 50 Hz -Q1 -T15 -Q0 -T1 Siprotec 1 7 9 50 50BF 51 59 7TC 79 Typical configuration of an AC contact line feeder in the autotransformator system with a numerical overhead contact line control and protection relay (contains optional functions) 6

Technical data 9,5 17 3 5 50 0 5 66 Side view Siprotec / Rear view Siprotec Rear view Siprotec Dimensions of Siprotec / (dimensions in mm) Ambient conditions Technical data (depending on product version) Climatic stress according to IEC 6055-6 Recommended temperature during operation* [ C] -5...+55 Permissible humidity stress on 56 days a year (relative humidity)* annual average on 56 days a year 75 % 93 % Installation altitude above sea level [m] 1,000 * other values on request Nominal (system) frequency adjustable Current / voltage inputs number of current inputs nominal current of current inputs number of voltage inputs nominal voltage of voltage inputs (adjustable) Power consumption per phase at I N = 1 A at I N = 5 A [Hz] [Hz] [A] [V] [VA] [VA] 16.7 5; 50 or 60 1 or 3 1 or 5 1 or 3 80 15 approx. 0.05 approx. 0.3 Mechanical design Weight [kg] [kg] 6 10 Binary inputs / outputs number of inputs number of outputs 1 38 or 7 36 Degree of protection acc. to IEC 6059 IP51 Fast tripping shortest tripping time [ms] < Standards IEC 6055 (product standards) ANSI / IEEE C37.90.0/.1/. UL 508 DIN 5735 T.303 7

Electrical data Auxiliary voltage (depending on product version) Rated auxiliary voltage [V DC] [V DC] [V DC] / 8 60 / 110 / 15 110 / 15 / 0 / 50 Binary inputs Quantity 1 (configurable) 38 (configurable) Rated voltage range [V DC]...50 Output relays Number (version with one transformer) (version with three transformers) NO contact (normal) 1 16 30 NO contact / NC contact (switchable) NO contact (fast) Making power [W or VA] 1,000 1,000 1,000 Breaking power ohmic at L/R 50 ms [W] [W or VA] 30 VA 0 5 30 VA 0 5 1,000 W or VA Switching voltage AC [V] 50 50 00 Switching voltage DC [V] 50 50 300 Continuous current per contact [A] 5 5 5 Total continuous current for grouped contacts [A] 5 5 Max. DC inrush current with a closing time of 0.5 s for NO contacts [A] 30 30 30 References Since the market introduction in 00 more than 1,700 devices of the Siprotec / overhead contact line control and protection relay are successfully in service all over the world. Siemens AG 016 All rights reserved Siprotec /63 / Product Information Nr. A6Z0811088957 / Version 1..0 Siemens AG Mobility Division Otto-Hahn-Ring 6 81739 Munich Germany For further information please contact: Siemens AG Mobility Division Turnkey Projects & Electrification Rail Electrification Mozartstraße 33b 9105 Erlangen Germany electrification.mobility@siemens.com www.siemens.com/rail-electrification Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features which may not always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested performance features are binding only when they are expressly agreed upon in the concluded contract.