RS232C/RS485 Data can be easily monitored by LAN

Similar documents
Phone: Fax: Web:

Network Instrumentation Module Communications box NX-CB1 Communications adapter NX-CL1/NX-CR1 Terminal adapter NX-TL1/NX-TR1

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

MODEL: R2K-1 SEN TRONIC AG. R2K Series

Model Number Structure

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

PROGRAMMABLE CONTROLLER FP3/FP10S THERMOCOUPLE INPUT UNIT

Conductive Level Controller

Communication & Networking

Preface. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation.

Automationdirect.com

Analog Input/Output Modules

Programmable Relay ZEN V2 Units

Network Instrumentation Modules NX Digital Output Modules NX-DY1/DY2

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

VAT series controller and transmitter. Manual

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

S8VE (60/90/120/180/240-W Models)

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Maximum Value for OEMs SM. NX70 Serial Communications Unit (SCU) User Manual

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

PC RELAY TERMINAL/ PC TERMINAL

See instructions to download and install the latest version of LinkBoxMB and the user's manual at


See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

PRESET HOUR METER. FEATURES 1. Preset function equipped in half size (24 48 mm inch). 2. Display has backlight for instant recognition.

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Instruction Manual LX7/LX7s

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

PFXGP4503TAD. Pro-face Xycom GP4000 PFXGP4503TAD

1. Safety Precautions (Read these precautions before use.)

MODEL: GR8-EM. Communication Adaptor GR8 Series

POWER ROCKER SWITCH. Standard actuator type Wide actuator type UL/C-UL, ENEC/VDE UL/C-UL, ENEC/VDE


Suitable for detecting transparent films or transparent bottles

DIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Cam Positioner H8PS. Plastic body, 2 m (6.56 ft.) cable Metal body, 2 m (6.56 ft.) cable

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

Package Contents. GP Options (Made by Digital)

User Guide TL-SG1024D 24-Port Gigabit Desktop/Rackmount Switch

DIGITAL INDICATING CONTROLLER

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Safety Relay Unit (I/O Unit Type)

Most Powerful Compact PLC!

Modbus Digital Remote I/O. ARM Series. Modbus Sensor Connector Type Digital Remote I/O. Features. User Manual For Communication. Ordering Information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

RT-1 PC RELAY TERMINAL RT-1 PC TERMINAL

BGS (at min. setting) BGS (at max. setting)

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

Module Type Controller SRV. PLC/Host Communication Instruction Manual IMS01P05-E5 RKC INSTRUMENT INC.

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 2-port RS422/485 Modbus Gateway

DPOM8-24/20 DIN RAIL POWER OVER MODBUS MODULE. Mounting and operating instructions

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

AI561 Analog Input Module

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

7032 Digital-Analog Multimeter

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Message Runner KP3H. Text Display. Small messages on your machine. Compact DIN 36 x 72 profile. Green and orange character display.

Mini Energy Web Server

PFXGP4601TAD. Pro-face Xycom GP4000 PFXGP4601TAD

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

INTELLIGENT SERVER. Model: BMS-LSV6E

Contact form. Operating Force. Plunger SPDT 204g Dust- Proof (in closed position) Plunger SPST-NC 204g Dust- Proof (in closed position)

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

One step ahead in performance and mounting ease

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

DX561 Digital Input/Output Module

Handheld Reader Writer

Vane Type Photoelectric Switches with Self-contained Amplifier

Model Number Structure

LC0 DVP

Model Number Structure

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

MODEL: WL40EW2F. Wireless I/O WL40F Series

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

RXTP ROOM TEMPERATURE

DC562, digital input/output module,

FL MC 2000E (SM40) LC

Operating instructions. Switching amplifier DN0210 DN / / 2015

TOS-SN-1 Extended Panel Operation Manual

Industrial 1-port RS422/485 Modbus Gateway

Transcription:

KS SIGNAL CVERTER (AKS) RSC/RS8 Data can be easily monitored by LAN KS SIGNAL CVERTER FEATURES The connectors are located on the front panel. Easy to connect Easy to operate Can be connected to the LAN without the need of switching between RSC and RS8 signals Easy-to-install DIN-rail-mountable type KW7M Eco-POWER METER Up to 99 meters RS8 LAN KWM Eco-POWER METER KS Signal Converter PC Compliance with RoHS Directive PRODUCT TYPES Main unit Options * Included with product Setting software Manual * Customer registration is required to download data. Rated voltage Signal conversion specifications Model number KS Signal Converter V DC Ethernet RSC/RS8 AKS0 Product name Descriptions Model number Power supply unit for FP0 Input: 00 to 0 VAC, Output: VDC, 0.7 A AFP06 Power supply cable for FPΣ* piece, m length AFPG80 Screwdriver for terminal block Using when wiring Phoenix terminal AFP0806 Product name Descriptions Remarks Configurator WD IP address searching tool software for KS You can download from our website (free of charge)* Product name Descriptions Remarks KS Signal Converter User s manual Detailed explanation of KS Signal Converter usage (pdf) You can download from our website (free of charge)* Phone: 800.89.0 - Fax: 888.7.77 - Web: www.clrwtr.com - Email: info@clrwtr.com

SPECIFICATIS General specifications Rated voltage Operating voltage range Inrush current Current consumption Allowed momentary power off time Fuse Terminal screw specifications Interface: Ethernet Ethernet is a registered trademark of Xerox Corporation. specifications Interface: RSC and RS8 Notes:. COM and COM can be used simultaneously.. When connecting a commercially available device, please confirm operation using the actual device. In some case, the number of stations, transmission distance, and communication speed vary depending on the connected device.. The values for the transmission distance, communication speed and number of stations should be within the values noted in the graph.. Number of TCP connections on the Ethernet side that can be connected to COM and COM.. Length of time until the communication from the Ethernet side cuts off due to no response from each remote unit. In case of 6s or more, time can be set in units of s. 6. Length of time until the signal converter side automatically ends the connection when the state of no communication from the Ethernet side with communication established exceeds the set time. 7. In case of setting 0: No disconnected, it cuts the connection automatically when no communication continues for two hours. 8. For transport layer protocol of Ethernet, MODBUS TCP (RTU, ASCII) can be selected in addition to TCP (from the main unit firmware V.0 or higher). KS SIGNAL CVERTER (AKS) V DC 90 to 0%V of rated voltage A or less 00 ma or less 0 ms Built-in type Ambient temperature 0 to C Storage temperature Ambient humidity Breakdown voltage (initial) Insulation resistance (initial) Vibration resistance Shock resistance 00 V AC minute 00 MΩ or higher (00 V DC using an insulation resistance meter) M 0 to +7 C 0 to 8% RH (at 0 C, non-condensing) RS8 terminals Combined power supply and ground terminals 0 to Hz, cycle/min.: double amplitude of 0.7 mm, hour on axes 9 m/s or more, times on axes Dimensions 60 90 Weight Interface Connector shape Transmission specifications cable Transmission speed Transmission method Max. segment length IEEE80.u, 0BASE-T/00BASE-TX RJ 0 Mbps/00 Mbps Base band 00 m Category UTP cable Protocol MODBUS TCP (RTU, ASCII), TCP/IP* 8 Functions Approx. 80 g Auto negotiation function, MDI/MDI-X, Auto crossover function Interface RSC (non-insulated) RS8 (insulated) Conversion COM port* COM COM style : communication : N communication Number of connectable stations station 99 stations max. method Full duplex Half duplex Synchronous method Start-stop synchronization Transmission distance m Max. 00 m *, speed 00, 800, 9600, 900, 800, 7600 and 00bps Number of connectable connections* COM receive time out* Setting range: 0 ms to 00 s Setting range: 0 ms to 00 s Non-communication time before disconnection* 6 Setting range: 0 to 800 s (Not disconnected when set to 0.) * 7 Conversion and transmission format Serial Ethernet conversion Data length Parity Stop bit End code 8 bits fixed Odd/Even/None bit/ bits CR, CR+LF, None Command/Response system Number of stations 99 70 0 0 700 000 Transmission distance (m) For transmission speed. kbps For transmission speed 7.6 kbps 00 Phone: 800.89.0 - Fax: 888.7.77 - Web: www.clrwtr.com - Email: info@clrwtr.com

LINK /ACT KS SIGNAL CVERTER (AKS) PARTS NAMES AND DIMENSIS (mm) CAD Data setting switch MODE.0 POWER RESET ERROR SPEED Connector for LAN: RJ Status display LED Input/Output display LED (LAN) The CAD data of the products with a CAD Data mark can be downloaded from Panasonic website. (9.) 60.0 NO Reset switch Labeling location Tolerance: ±.0 setting switch OFF RSC SG + - RS8 + C 8 Input/Output display LED (RSC/RS8) 90.0 - E Signal Converter KS DIN hook Expansion hook (V DC) Power connector Power cable (option): AFPG80 Terminal block for RSC/RS8 Terminal screwdriver: AFP0806 Tightening torque: 0. to 0. N m TERMINAL ARRANGEMENT Be sure to wire correctly according to the terminal arrangement and wiring diagrams. LAN Connector Connector: RJ Cable: UTP (Category or more) This unit recognizes automatically the cable, cross or straight. Select cable according to the connected devices. Power supply connector Use the attached power supply cable (AFPG80) to connect power supply. Mark Attached power supply cable + Brown V DC Blue 0V Green Function earth Notes:. Please use twisted lines for power supply line (brown and blue) in order to reduce the noise effect from outside.. Please use a power supply of the insulation type with built-in protection circuit in order to protect against an abnormal voltage from power supply line.. Regulator on the unit is non-insulation type.. Use power supply voltage within the range of allowable voltage. Rated voltage Operating voltage range V DC.6 to 6.V DC RSC/RS8 terminal block RSC RS8 SG E Terminal shape Terminal No. 6 7 8 No. 6 7 8 Functions RSC RSC RSC SG RS8 RS8 RS8 RS8 RS8 E Terminal name Phone: 800.89.0 - Fax: 888.7.77 - Web: www.clrwtr.com - Email: info@clrwtr.com

KS SIGNAL CVERTER (AKS) COMMUNICATI SETTING You can set communication conditions by two methods, using the communication set switches on the front of main unit and using the setting software (Configurator WD). Set by the communication set switches Use set switch and set switch to set communication setting. MODE OFF set switch O N set switch set switch set switch MODE Item OFF Transmission speed Below table Setting method Software Hardware * Parity Not available Available Parity Even number Odd number Stop bit Vacant MODE MODE MODE Transmission speed OFF OFF OFF 00bps OFF OFF 00bps OFF OFF 800bps OFF 9600bps OFF OFF 900bps OFF 800bps OFF 7600bps 00bps Notes:. Only when MODE of switch is set to (Hardware), and switches setting is available.. When MODE of switch is set to OFF (Software), and switches setting is not available.. Data length is fixed with 8 bit.. Setting conditions are read when power turns on. You should set them before power turns on. If you change the settings while power turns on, some malfunctions might be occurred.. When setting by hardware (communication set switches), RSC and RS8 communication settings are set as same. If individual setting for RSC and RS8 is required, use the setting software. Set by setting software Configurator WD You can download the setting software Configurator WD from our website. Please refer to the help in Configurator WD for the way to set. Note: In case of setting by Configurator WD, MODE of switch should be set to OFF (software). CAUTIS FOR SAFETY Please use correctly only after you have thoroughly read User s Manual, Instruction Manual, and Catalog. Phone: 800.89.0 - Fax: 888.7.77 - Web: www.clrwtr.com - Email: info@clrwtr.com

KS SIGNAL CVERTER (AKS) CAUTIS BEFORE USING Do not use the Unit in the following environments. Where the unit will be exposed to direct sunlight and where the ambient temperature is outside the range of 0 to C. Where the ambient humidity is outside the range of 0 to 8% RH (at 0 C non-condensing) and where condensation might occur by sudden temperature changes Where inflammable or corrosive gas might be produced Where the unit will be exposed to excessive airborne dust or metal particles Where the unit will be exposed to water, oil or chemicals Where organic solvents such as benzene, paint thinner, alcohol, or strong alkaline solutions such as ammonia or caustic soda might adhere to the product Where direct vibration or shock might be transmitted to the product, and where water might wet the product Places unaffected by power transmission lines, high voltage equipment, power cables, power equipment, radio transmitters and any other equipment that would generate high switching surge. Please use the Unit according to the specifications described in this manual. Otherwise, it may malfunction or cause fire and an electric shock. Connect to the power supply in compliance with the rating. Refer to the wiring diagram to ensure proper wiring for the power supply, input and output. Do not perform wiring or installation with a live line. It may also lead to circuit burnout or fire. Do not add voltage and current to an output terminal from outside. Static electricity Discharge static electricity touching the grounded metal etc. when you touch the unit. Excessive static electricity might be generated especially in a dry place. Cleaning Wipe dirt of the main unit with soft cloth etc. When thinner is used, the unit might deform or be discolored. Power supply Connect a breaker to the voltage input part for safety reasons and to protect the device. Do not turn on the power supply or input until all wiring is completed. Do not add abnormal voltage directly, otherwise it might damage internal circuit. Before power on Please note the following points when turning on power at the first time. Confirm there are neither wiring rubbish nor especially an electrical conduction when installed. Confirm neither the power supply wiring, the I/O wiring nor the power-supply voltage are wrong. Tighten the installation screw and the terminal screw surely. Use an electric wire applicable to the rated current. Others Please note that it might take time to approve the communication again after power on and breaking the communication. This product is designed to be used only with our options. Options from other companies are not compatible. Phone: 800.89.0 - Fax: 888.7.77 - Web: www.clrwtr.com - Email: info@clrwtr.com