WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

Similar documents
High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

Standard-Signal Isolation Amplifiers. VariTrans A 21000

VariTrans P The Problem The variety of tasks results in a large number of different devices.

VariTrans P Standard-Signal Isolators

Signal Doublers. VariTrans A 20300

SensoTrans DMS A 20220

SensoTrans DMS P 32200

Indicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator

Alarm Unit DG 3200 Control And Monitor Standard Signals

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-120VAC

PHOENIX CONTACT - 12/2007

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

Contact protection relay

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Intrinsically Safe Barriers

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

PHOENIX CONTACT - 05/2007

Extract from the online catalog

QUINT-PS AC/24DC/10

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Operating Instructions

MINI MCR-SL-CVS NC

QUINT-PS/ 1AC/24DC/ 5

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

Process Analysis Systems. Stratos Pro A4 MSPH/MSPH. Chem Energy Pharm Food Water. Connection

MINI MCR-SL-PT100-UI-200

Installation / Control Technique

Process display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction.

5 Fieldbus Technology

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

RM35LM33MW liquid level control relay RM35-L V AC/DC

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

RM17TG. Main. Product or component type. Product specific application. Relay monitored parameters. Switching capacity in VA 250 V AC

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

SR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Extract from the online catalog

DT1102 V (PS) Fully Configurable Galvanic Isolator. Operating Instructions

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Operating Instructions VEGAMET 381

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

ETD-BL-1T-OFF-CC- 10S

Power Supply HARTING pcon

MINI MCR-SL-UI-2I(-SP)(-NC)

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

RM35LM33MW liquid level control relay RM35-L V AC/DC

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

PHOENIX CONTACT - 07/2006

SR2B202BD compact smart relay Zelio Logic - 20 I O - 24 V DC - clock - display

SITOP in the SIMATIC Design

Cradle relay AC. Electrical data Operating data (coil circuit) U N. Explosion protection Marking ATEX. II 2G Ex db e IIC Gb I M2 Ex db e I Mb I N

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Faults on the system Proximity switch connection technology:

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids

RM35TF. Main. Product or component type. Product specific application. Relay monitored parameters 250 V AC 5 A AC

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Connection of OXY module with oxygen sensor (SE 706, Mettler Toledo InPro 6800, Hamilton Oxyferm) Model used: Stratos Pro A401N OXY/ V AC/DC

MINI MCR-SL-PT100-UI(-SP)(-NC)

RM17UAS. Product datasheet Characteristics. voltage control relay RM17-U - range V DC. Main. Complementary. Price* : 70.

Operating Instructions

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Power Supply HARTING pcon

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

RE7YA12BU time delay relay for star-delta starter s - 24 V AC DC - 2OC

SR2B121BD compact smart relay Zelio Logic - 12 I O - 24 V DC - clock - display

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

SITOP 3-phase 24 V DC, 20 to 40 A

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

RM35TF V AC

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Liquipoint T FTW31, FTW32

SIPLUS S7-200 PS 203. Overview

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

STEP-PS/1AC/24DC/1.75

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

MODEL 9250 Preliminary data sheet

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

Transcription:

Modular Housings for Hazardous Areas For transmission of 0(4)... 20-mA signals from hazardous areas or supply of intrinsically safe 2-wire transmitters. The Task The power supply/isolator is used to supply intrinsically safe 2-wire transmitters. It supplies the transmitter with power and transmits the measurement signal to the output with high accuracy. The Advantages The provides Safe Isolation and high insulation from the input to the output and to the power supply. The Technology An additional measurement current input allows use as a highly accurate standardsignal isolator in hazardous areas. High supply voltage, good hazardous area ratings and the simple LiveZero (4...20 ma) / Dead Zero (0...20 ma) switching allow universal applications. The achieves an extraordinarily high transmission accuracy for hazardous-area applications. The control range of the measuring circuit extends to the negative values and allows strictly linear transmission also in the zero range. The encapsulation technique allows maximum operating safety, long-time stability, and disruptive strength even under extreme conditions. Warranty 5 years! Defects occurring within 5 years from delivery are remedied free of charge at our works (carriage and insurance paid by sender). 228

Repeater Power Supplies Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings The Facts Universal use for 2-wire transmitters or as standardsignal isolators Low stockkeeping costs with many application possibilities Safe Isolation according to EN 61140 Protection of maintenance staff and subsequent devices against non-permitted high voltages 3-port isolation Protection against incorrect measurements or damage to the equipment due to parasitic voltages High transmission accuracy Exact transmission of measured values Explosion protection according to ATEX Trouble-free use in hazardous areas Output 0... 20 ma or 4... 20 ma, switchable Universal adaptation to the following devices Measuring circuit with linear zero crossing No transmission loss in the zero range Modular housing 22.5 mm Straightforward installation due to compact design 5-year warranty Modular Housings Product Line Devices Order No. A2 24 V AC/DC 229

Modular Housings for Hazardous Areas Specifications Operation as a repeater power supply Input 4... 20 ma, intrinsically safe (current loop) Output 4... 20 ma/0... 20 ma, switchable 1) loop Intrinsically safe supply voltage 20 V, constant for 0... 22 ma, floating, resistant to continuous short-circuit, current limited to 30 ma, residual ripple < 10 mv pp Operation as isolation amplifier Input 2) 0... 20 ma, intrinsically safe 4... 20 ma, intrinsically safe Output 0... 20 ma 4... 20 ma/0... 20 ma, switchable 1) Overload capacity (at input) 300 ma, limited by diode 1 V, 13 ohms Input voltage drop 300 mv Output data Load 12 V Offset < 10 µa Residual ripple at output 10 mvpp Transmission behavior Transmission error (at output) Cutoff frequency Temperature coefficient (at output) 0.1% meas. val. 1 khz, 3 db 1 µa/k (reference temperature 23 C) 24 V AC/DC AC 15 % +10 %, 48... 62 Hz, approx. 3.3 VA DC 15% +20%, approx. 2.2 W 1) Additional error at output 10 µa 2) Transmission of negative signals up to approx. 3% full scale 230

Repeater Power Supplies Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Specifications (continued) Isolation Galvanic isolation 3-port isolation between input, output and power supply Test voltage 4 kv AC (current loop, input / output / power supply) Working voltages 1000 V AC/DC current loop, input against output and power supply (basic insulation) 800 V AC/DC output against power supply with overvoltage category II and pollution degree 2 according to EN 61010-1. For applications with high working voltages, you should ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks. For hazardous area applications the maximum working voltage is 250 V. Protection against Safe Isolation according to EN 61140 by reinforced insulation in accordance with electric shock EN 61010-1. Working voltages with overvoltage category II and pollution degree 2: up to up to 600 V AC/DC across current loop, input, and output / power supply, as well as 250 V AC/DC across output and power supply. For applications with high working voltages, you should ensure there is sufficient spacing or isolation from neighboring devices and protection against electric shocks. For hazardous area applications the maximum working voltage is 250 V. Modular Housings Standards and approvals Explosion protection II (1) G [EEx ia] IIC current loop, input intrinsically safe, PTB 99 ATEX 2047, for further details see certificates of conformity at our website: www.knick.de EMC 89/336/EEC directive 3) Other data Ambient temperature Operation: 10... +60 ºC Transport and storage: 30... +80 ºC Design Modular housing, width 22.5 mm, screw terminals See dimension drawings for further measurements Ingress protection Housing IP 40, terminals IP 20 Mounting With snap-on mounting for 35 mm top hat rail according to EN50022 or M4 screw mounting, see dimension drawings for conductor cross section Weight Approx. 250 g 3) Deviations are possible while there is interference 231

Modular Housings for Hazardous Areas Block Diagram + v i loop Z 24 V + input 13 Ø Z 15 V + output Application Example Hazardous area 2-wire transmitter loop Safe area Output circuit Input e.g. PCS, recorder 232

Repeater Power Supplies Isolation Amplifiers Transmitters Indicators Process Analytics Portable Meters Laboratory Meters Sensors Fittings Dimension Drawings and Terminal Assignments 22.5 Ø 4.4 88 1 9 5 1 loop ; Input + 5 loop + 9 Input 89 80 3 11 7 76.6 75 53 81 3 Output + 7 Output ; jumper 11 Jumper (for output 0... 20 ma: jumper 7 11) 4 8 Screw mounting with extending lugs Snap-on mounting for 35 mm top-hat rail (EN 50022) 99 4 8 Modular Housings M3x8 connecting screws with self-releasing clamping pieces, max. conductor cross-section 2 x.1.5 mm 2 solid or 2 x 1.0 mm 2 stranded wire with ferrule All dimensions in mm! 233