Dell EMC Networking S4148-ON and S4128-ON

Similar documents
Dell EMC Networking S4148-ON and S4128-ON

Dell EMC Networking S6010-ON

Dell Networking S4048-ON

Cisco Nexus Switch Configuration Guide for Dell SC Series SANs. Dell Storage Engineering August 2015

Dell Networking S6000

Arista 7050SX-96-F. Switch Configuration Guide for Dell PS Series SANs. A Dell Deployment and Configuration Guide

Cisco Nexus 5648Q. Switch Configuration Guide for Dell PS Series SANs

Dell Networking S3048-ON

Cisco Nexus 5648Q. Switch Configuration Guide for Dell EMC SC Series SANs

Huawei CloudEngine 6850

Dell Networking N4000 Series and Dell PowerConnect 8100 Series

Cisco Nexus 9372PX. Switch Configuration Guide for Dell EMC SC Series SANs. A Dell EMC Deployment and Configuration Guide

Dell Networking S60 and Dell Force10 S60

Cisco Nexus 9372PX. Switch Configuration Guide for Dell PS Series SANs. A Dell EMC Deployment and Configuration Guide. Dell EMC Engineering June 2017

Huawei CloudEngine 6850

Dell Networking N2000 Series

Dell EMC Networking Deploying Data Center Bridging (DCB)

Dell Force10 S4810 Switch

Dell Force10 S4810 Switch

Configuring Link Level Flow Control

Configuring Link Level Flow Control

Dell PS Series DCB Configuration Best Practices

Deploying FCoE (FIP Snooping) on Dell PowerConnect 10G Switches: M8024-k, 8024 and 8024F. Dell Networking Solutions Engineering March 2012

PowerEdge FX2 - Upgrading from 10GbE Pass-through Modules to FN410S I/O Modules

Configuring Link Level Flow Control

Configuring Link Level Flow Control

Best Practices for a DCB-enabled Dell M-Series Blade Solution with EqualLogic PS-M4110

Dell PowerEdge M1000e Blade Enclosure and Dell PS Series SAN Design Best Practices Using Dell S-Series and M-Series Networking

Configuring FCoE NPV. FCoE NPV Overview. FCoE NPV Benefits

Dell EMC Ready Stack: Microsoft Hyper-V on PowerEdge 14G Servers and Unity Storage

Deployment of Dell M8024-k Blade Switch in Simple Mode with Cisco Nexus 5k Switch

Planning and Preparation Guide

Best Practices for Deploying a Mixed 1Gb/10Gb Ethernet SAN using Dell Storage PS Series Arrays

Lenovo NE1032 and NE1032T Switch

Using Switches with a PS Series Group

Dell and Emulex: A lossless 10Gb Ethernet iscsi SAN for VMware vsphere 5

Dell Networking MXL / PowerEdge I/O Aggregator with Cisco Nexus 5000 series NPV mode and Cisco MDS 9100 fabric switch Config Sheets

Using Switches with a PS Series Group

A Dell Interoperability Whitepaper Victor Teeter

Best Practices for Mixed Speed Devices within a 10 Gb EqualLogic Storage Area Network Using PowerConnect 8100 Series Switches

Configuring Virtual Port Channels

Best Practices for Sharing an iscsi SAN Infrastructure with Dell PS Series and SC Series Storage using VMware vsphere Hosts

Deployment of Dell M6348 Blade Switch with Cisco 4900M Catalyst Switch (Simple Mode)

Dell Networking MXL and PowerEdge I/O Aggregator with Cisco Nexus 5000 series fabric mode Config Sheets

Dell EqualLogic Best Practices Series. Best Practices for Dell EqualLogic SANs Utilizing Cisco Nexus

Configuring Priority Flow Control

Configuring Network QoS

Configuring Queuing and Flow Control

LAN Ports and Port Channels

Boot and Network Configuration Deployment using Server Template with Dell EMC OpenManage Essentials (OME)

Reference Architectures for designing and deploying Microsoft SQL Server Databases in Active System800 Platform

Application Notes for Force10 Networks C-Series C300 Switch connected to Avaya Distributed Office in a Converged VoIP and Data Network - Issue 1.

DEPLOYING A STACK OF DELL M-SERIES BLADE SWITCHES IN SIMPLE SWITCH MODE (SSM)

Data Migration from Dell PS Series or PowerVault MD3 to Dell EMC SC Series Storage using Thin Import

Best Practices for Configuring DCB with VMware ESXi 5.1 and Dell EqualLogic Storage

Configuring Interfaces

Best Practices for Configuring Data Center Bridging with Windows Server and EqualLogic Storage Arrays

Management Software AT-S101. User s Guide. For use with the AT-GS950/8POE Gigabit Ethernet WebSmart Switch. Version Rev.

Switch Configuration Example for Q-SYS Platform Extreme Networks Summit X450-G2 Series

Configuring Virtual Port Channels

Dell PowerEdge Configuration Guide for the M I/O Aggregator 9.5(0.1)

FCoE Cookbook for HP Virtual Connect

T PCT. Smart PoE Switch REV

Dell EMC Ready Stack: VMware IaaS on PowerEdge MX Servers and PowerMax Storage

UCS deployment guide for Nimble Storage

VMware ESXi Host Configuration

iscsi Boot from SAN with Dell PS Series

Configuring Virtual Port Channels

NetApp HCI with Mellanox SN2010 Switch Quick Cabling Guide

EqualLogic Storage and Non-Stacking Switches. Sizing and Configuration

Lenovo RackSwitch G8272. Release Notes. For Cloud Network Operating System 10.3

Configuring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections:

Configuring Virtual Port Channels

Configuring Network QoS

Configuring Fabric QoS Mapping

Dell PowerEdge FN I/O Aggregator. Command Line Reference Guide 9.8(0.0)

Cisco UCS 6324 Fabric Interconnect

Changing default password of root user for idrac9 by using Dell EMC License Manager

Configuring Queuing and Flow Control

17TB and 26TB Data Warehouse Fast Track for Microsoft SQL Server 2014 using PowerEdge R730 Server and Dell Storage PS Series PS6210S

Cisco Nexus B22 Blade Fabric Extender for IBM

VxRack System SDDC Enabling External Services

Peplink SD Switch User Manual. Published on October 25th, 2018

April Brocade VDX 6740 Deployment Guide for VMware EVO:RAIL

Configuring Voice VLAN

Switch Configuration Example for Q-SYS Platform Cisco Catalyst 3650 and 3850 Series

Dell EMC XC Series Networking Deployment and Best Practices Guide v2.0

FIBRE CHANNEL OVER ETHERNET

TL-SL2210/TL-SL2218/TL-SL2428/TL-SL2452. Smart Switch REV

Configuring Priority Flow Control

Cisco Nexus 9000 Series NX-OS FC NPV Configuration Guide, Release 9.x

Configuring Priority Flow Control

Configuring a Dell EqualLogic SAN Infrastructure with Virtual Link Trunking (VLT)

Emulex Universal Multichannel

Switch Configuration Example for Q-SYS Platform HP 1910 and HP 1920

Configuring Interfaces

Management Software AT-S79. User s Guide. For use with the AT-GS950/16 and AT-GS950/24 Smart Switches. Version Rev.

Best Practices for Deployments using DCB and RoCE

Cisco Nexus 7000 Series NX-OS Quality of Service Command Reference

Ethernet Switch Setup for Q-SYS HP 1910 and 1920 Series (Gigabit only)

Transcription:

Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs Abstract This document illustrates how to configure Dell EMC Networking S4148-ON and S4128-ON switches for use with Dell PS Series storage using Dell EMC best practices. October 2017 Dell EMC Configuration and Deployment Guide

Revisions Revisions Date October 2017 Revision Initial release The information in this publication is provided as is. Dell Inc. makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any software described in this publication requires an applicable software license. 2017 Dell Inc. or its subsidiaries. All Rights Reserved. Dell, EMC, Dell EMC and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners. Dell believes the information in this document is accurate as of its publication date. The information is subject to change without notice. 2 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Table of contents Table of contents 1 Introduction... 5 1.1 Document conventions... 5 1.2 Audience... 5 1.3 Switch details... 6 1.4 Cabling diagram... 7 2 Dell EMC recommended switch configuration... 8 2.1 Hardware configuration... 8 2.1 Check firmware version... 8 2.2 Delete startup configuration... 8 2.3 Switch profiles (only for S4148-ON and its variants)... 9 2.4 Configure unified ports on S4148U-ON... 9 2.5 Configure out of band (OOB) management port... 9 2.6 Configure login credentials... 10 2.7 Configure QSPF+ and QSFP28 ports to 4 x 10GbE breakout ports... 10 2.8 Enable switch ports... 10 2.9 iscsi enable... 11 2.10 Enable Jumbo frames and flow control (optional)... 11 2.11 Configure spanning tree on edge ports... 11 2.12 Configure port channel for link aggregation... 12 2.13 Configure port channel member ports... 12 2.14 Save configuration... 12 2.15 Configure additional switch... 12 3 Configure Data Center Bridging (DCB) (optional)... 13 3.1 Disable iscsi... 13 3.2 Disable 802.3x flowcontrol on all ports... 13 3.3 Enable DCB... 13 3.4 Create tagged VLAN for all ports and port-channels... 13 3.5 Create QoS policy map with dot1p values as trusted... 14 3.6 Create PFC dot1p traffic class... 14 3.7 Configure network QoS policy map... 14 3.8 Configure ETS policies... 15 3.9 Create ETS policy-map for bandwidth allocations... 15 3.10 QoS policy... 15 3.11 Apply policies and VLAN ID to all switch edge ports (except port-channel member ports)... 16 3 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Table of contents 3.12 Apply policies and VLAN ID on port channel and its member ports... 16 3.13 iscsi enable... 17 3.14 Save configuration... 17 3.15 Show commands to verify DCBx, ETS, and PFC status on individual ports... 17 3.16 Configure additional switches... 17 4 Reverting from DCB to non-dcb configuration (optional)... 18 4.1 Disable DCB... 18 4.2 Disable iscsi... 18 4.3 Remove DCB policies and apply standard flow control on edge ports... 18 4.4 Remove DCB policies and apply standard flow control on port-channel member ports... 19 4.5 Revert to default VLAN ID on switch and arrays... 19 4.6 Removing ETS, PFC, and other policies from switch configuration... 20 4.7 iscsi enable... 20 4.8 Save configuration... 20 4.9 Reload... 20 4.10 Verify DCB status... 20 4.11 Configure additional switch... 20 A Technical support and resources... 21 A.1 Related resources... 21 4 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Introduction 1 Introduction This document illustrates how to configure Dell EMC Networking S4148-ON and S4128-ON switches for use with Dell PS Series storage using Dell EMC best practices. The recommended configuration uses link aggregation groups (LAGs) for inter-switch connections. The host servers and storage controllers can be connected to the switches using the QSFP+ and QSFP28 ports with appropriate breakout cables. The switches are interconnected to each other using 40GbE cables or 100GbE cables. Optional steps are provided in section 3 to enable Data Center Bridging (DCB). Note: If you are following the Rapid EqualLogic Configuration steps at http://en.community.dell.com/techcenter/storage/w/wiki/3615.rapid-equallogic-configuration-portal-bysis.aspx, use sections 1 and 2, or 1 and 3 (DCB environment) in this Switch Configuration Guide. Note: For more information on PS Series SAN design recommendations, see the Dell PS Series Configuration Guide. 1.1 Document conventions Table 1 lists the formatting conventions used in this document. Document conventions Format Description Example Bold User input OS#show version Bold italic User input (variable) OS#my password <Italic> <brackets> Separate variables <ip address> <mask> 1.2 Audience This switch configuration guide describes an optimal configuration following Dell EMC best practices for a PS Series iscsi SAN and is intended for storage or network administrators and deployment personnel. 5 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Introduction 1.3 Switch details Table 2 provides an overview of the switch configuration. Switch specifications Dell EMC Networking S4148-ON/S4128-ON Switch vendor Switch model Switch firmware Dell EMC S4148U-ON, S4148F-ON, S4148FE-ON, S4148T-ON, S4128F- ON, and S4128T-ON 10.3.1 or later Note: For proper functionality, the switch must be at the switch firmware version shown in Table 2 before proceeding with this configuration. Using previous firmware versions may have unpredictable results. Note: The latest firmware updates and documentation can be found at Dell.com/support. 6 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Introduction 1.4 Cabling diagram The cabling diagram shown in Figure 1 represents the Dell EMC recommended method for deploying servers and PS Series arrays. Cabling diagram 7 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Dell EMC recommended switch configuration 2 Dell EMC recommended switch configuration The steps in this section show how to configure two Dell EMC Networking S4148-ON/S4128-ON switches with a Link Aggregation Group (LAG). The switches are interconnected using two of the 40 GbE Quad Small Form-factor Pluggable (QSFP+) ports. They can be also connected using a 100GbE (QSFP28) interconnect, and the LAG is configured for Dynamic Link Aggregation Control Protocol (LACP). This example uses physical ports 28 and 30 for the host server and storage controller connections. 2.1 Hardware configuration 1. Power on the two switches. 2. Connect a serial cable to the serial port of the first switch. 3. Using PuTTY or another terminal utility, open a serial connection session to the switch. 4. Open the terminal emulator and configure it to use the serial port (COM1, COM2). Configure serial communications for 115200 N, 8, 1 and no flow control. 5. Connect the (QSFP+) LAG cables between the switches by connecting physical port 28 on switch 1 to physical port 28 on switch 2, and physical port 30 on switch 1 to physical port 30 on switch 2. See this configuration in Figure 1. 2.1 Check firmware version OS10# show version Note: If the active version displayed here is not 10.3.1.x or later, visit Dell.com/support and download the latest update for the switches. 2.2 Delete startup configuration Note: The following commands will delete all configuration settings. OS10# delete startup-configuration Proceed to delete startup-config [confirm yes/no(default)]yes OS10# reload System configuration has been modified. Save? [yes/no]no Proceed to reboot the system? [confirm yes/no]yes Note: The switch will reboot. After the startup configuration is deleted, the factory default password is admin. 8 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Dell EMC recommended switch configuration 2.3 Switch profiles (only for S4148-ON and its variants) On the S4148-ON switch and its variants, switch port profiles determine the available front-panel Ethernet ports and supported breakout interfaces on uplink ports. Refer to the switch user s guide to determine which switch profile fits for your environment. Note: Changing switch profiles will delete all configuration information from the switch except for the management port configuration. Save and reload the switch for the new switch profile to take effect. OS10# configure terminal switch-port-profile 1/1 profile-<number> Warning: Switch port profile will be applied only after a save and reload. All management port configurations will be retained but all other configurations will be wiped out after the reload. exit OS10# copy running-configuration startup-configuration OS10# reload Proceed to reboot the system? [confirm yes/no]yes 2.4 Configure unified ports on S4148U-ON Note: This section applies to the S4148U-ON switch only. Skip this section if using other switches. This section configures unified ports on S4148U-ON switches to Ethernet ports. Refer to the switch user s guide for further details. Port-group 1/1/1-1/1/6 refers to the first 24 SFP+ ports on the switch. Use the following commands to convert these ports to Ethernet port. OS10# configure terminal port-group 1/1/<port-group-number> OS10(conf-pg-1/1/1)# mode Eth 10g-4x OS10(conf-pg-1/1/1)# exit Repeat the prior steps for port-group 1/1/1 to 1/1/6. Note: QSFP+ and QSFP28 ports are by default in Ethernet mode. They can be configured by configuring port-group 1/1/7-1/1/10 using the prior commands. Refer to the S4148-ON switch user s guide for more information. 2.5 Configure out of band (OOB) management port interface mgmt 1/1/1 OS10(conf-if-ma-1/1/1)# no ip address dhcp OS10(conf-if-ma-1/1/1)# ip address <ipaddress>/<subnet> OS10(conf-if-ma-1/1/1)# exit 9 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Dell EMC recommended switch configuration 2.6 Configure login credentials username admin password $0$<password> 2.7 Configure QSPF+ and QSFP28 ports to 4 x 10GbE breakout ports QSFP+ and QSFP28 ports on S4148-ON and S4128-ON switches can be configured as breakouts to be used with 10GbE iscsi storage or server network adapters. To configure these ports as 4 x 10GbE ports, use the following commands. interface breakout 1/1/<port-number> map 10g-4x exit OS10# Use the following command to check port interface status: OS10# show interface status 2.8 Enable switch ports Switch ports are enabled and are configured for switchport mode access by default for S4148-ON and S4128-ON switches. If choosing to reconfigure the ports, use the following steps. Option 1: Enable ports individually by entering the port number. OS10# configure terminal interface ethernet 1/1/1 Note: For ports configured as 4 x 10GbE breakout ports, use the following command in which 1/1 represents the switch number, xx represents port number, and yy represents sub port number: OS10(conf)#interface ethernet 1/1/xx:yy OS10(conf-if-eth1/1/1)# switchport mode access OS10(conf-if-eth1/1/1)# no shutdown OS10(conf-if-eth1/1/1)# exit Option 2: Enable multiple ports at once using the range parameter. OS10# configure terminal interface range ethernet 1/1/1 1/1/54 10 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Dell EMC recommended switch configuration Note: For ports configured as 4 x 10GbE breakout ports, use the following command in which 1/1 represents the switch number, xx represents port number, and yy represents sub port number: OS10(conf)#interface range ethernet 1/1/xx:yy-1/1/xx:yy OS10(conf-range-eth1/1/1-1/1/54)# switchport access mode OS10(conf-range-eth1/1/1-1/1/54)# no shutdown OS10(conf-range-eth1/1/1-1/1/54)# exit 2.9 iscsi enable The steps in this section enable iscsi auto-detection of attached storage arrays and switch autoconfiguration. PS Series and SC Series storage arrays are detected by the switch when iscsi is enabled. The switch will auto-configure for Jumbo frames with MTU 9216 and flowcontrol receive on, and transmit off for all the ports. The ports detected to be connected to the storage units will be auto-configured as spanning-tree edge ports with unicast storm control disabled. iscsi enable iscsi session-monitoring enable 2.10 Enable Jumbo frames and flow control (optional) Note: This step is optional because iscsi auto-detection and auto-configuration enabled in the previous step will enable Jumbo frames with MTU 9216 and enable receive flowcontrol on all ports, once PS Series or SC Series storage ports are detected on the switch. interface range ethernet 1/1/1 1/1/54 OS10(conf-range-eth1/1/1-1/1/54)# mtu 9216s OS10(conf-range-eth1/1/1-1/1/54)# flowcontrol receive on OS10(conf-range-eth1/1/1-1/1/54)# flowcontrol transmit off 2.11 Configure spanning tree on edge ports OS10(conf-range-eth1/1/1-1/1/54)# spanning-tree port type edge OS10(conf-range-eth1/1/1-1/1/54)# exit Note: Spanning tree is enabled by default. If there is a need to reconfigure it, use the following command. no spanning-tree disable exit 11 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Dell EMC recommended switch configuration 2.12 Configure port channel for link aggregation These commands create a port channel or link aggregation used as an interconnect between two switches. interface port-channel 1 OS10(conf-if-po-1)#mtu 9216 OS10(conf-if-po-1)#no shutdown OS10(conf-if-po-1)#exit 2.13 Configure port channel member ports This configuration guide uses ports 1/1/28 and 1/1/30 as port channel member ports. They are configured using following commands. Note: All port channel member ports need to be of same speed. For example, when using 40GbE ports for port channel, do not add any member ports with a different port speed such as 100GbE or 10GbE. interface range ethernet 1/1/28,1/1/30 OS10(conf-range-eth1/1/28,1/1/30)# no switchport OS10(conf-range-eth1/1/28,1/1/30)# channel-group 1 mode active OS10(conf-range-eth1/1/28,1/1/30)# mtu 9216 OS10(conf-range-eth1/1/28,1/1/30)# flowcontrol receive on OS10(conf-range-eth1/1/28,1/1/30)# flowcontrol transmit off OS10(conf-range-eth1/1/28,1/1/30)# exit exit 2.14 Save configuration OS10#copy running-configuration startup-configuration OS10#reload System configuration has been modified. Save? [yes/no]: yes Proceed to reboot the system? [confirm yes/no]:yes 2.15 Configure additional switch Repeat the commands from section 2 to configure the second switch. Note: The preceding procedure places all switch ports in the default VLAN. If preferring to place ports in a non-default VLAN, refer to the switch documentation. 12 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Configure Data Center Bridging (DCB) (optional) 3 Configure Data Center Bridging (DCB) (optional) To enable DCB mode on the switch, use the commands in this section. Note: Complete the switch configuration steps in section 2 before configuring the switch for DCB mode. 3.1 Disable iscsi OS10# configure terminal no iscsi enable no iscsi session-monitoring enable exit 3.2 Disable 802.3x flowcontrol on all ports OS10# configure terminal interface range ethernet 1/1/1 1/1/54 OS10(conf-range-eth1/1/1-1/1/54)# no flowcontrol receive OS10(conf-range-eth1/1/1-1/1/54)# no flowcontrol transmit OS10(conf-range-eth1/1/1-1/1/54)# exit 3.3 Enable DCB dcbx enable 3.4 Create tagged VLAN for all ports and port-channels Note: You must supply a VLAN ID. The valid range is 2-4093. The following commands will configure single VLAN ID. If desired, multiple VLAN IDs can be created on the switch and assigned to ports. interface vlan <vlan-id> OS10(conf-if-vl-<vlan-id>)# mtu 9216 OS10(conf-if-vl-<vlan-id>)# no shutdown OS10(conf-if-vl-<vlan-id>)# exit 13 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Configure Data Center Bridging (DCB) (optional) 3.5 Create QoS policy map with dot1p values as trusted policy-map type qos <trust-policy-map-name> OS10(config-pmap-qos)# class class-trust OS10(config-pmap-c-qos)# trust dot1p OS10(config-pmap-c-qos)# exit OS10(config-pmap-qos)# exit 3.6 Create PFC dot1p traffic class The following commands configure a network QoS class map and the iscsi traffic class. class-map type network-qos <iscsi-class-map-name> OS10 (config-cmap-nqos)# match qos-group 4 OS10 (config-cmap-nqos)# exit 3.7 Configure network QoS policy map policy-map type network-qos <policy-map-name> OS10(config-pmap-network-qos)# class <iscsi-class-map-name> OS10 (config-pmap-c-nqos)# pause OS10 (config-pmap-c-nqos)# pfc-cos 4 OS10 (config-pmap-c-nqos)# exit OS10(config-pmap-network-qos)# exit policy-map type application <qos-policy-map-name> OS10(config-pmap-application)# class class-iscsi OS10 (config-pmap-c-app)# set qos-group 4 OS10 (config-pmap-c-app)# set cos 4 OS10 (config-pmap-c-app)# exit OS10(config-pmap-application)# exit 14 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Configure Data Center Bridging (DCB) (optional) 3.8 Configure ETS policies qos-map traffic-class <queue-map-name> OS10(config-qos-map)# queue 0 qos-group 0-3,5-7 OS10(config-qos-map)# queue 4 qos-group 4 OS10(config-qos-map)# exit class-map type queuing <LAN-traffic-map-name> OS10(config-cmap-queuing)# match queue 0 OS10(config-cmap-queuing)# exit class-map type queuing <iscsi-traffic-map-name> OS10(config-cmap-queuing)# match queue 4 OS10(config-cmap-queuing)# exit 3.9 Create ETS policy-map for bandwidth allocations policy-map type queuing <queuing-policy-name> OS10(config-pmap-queuing)# class <LAN-traffic-map-name> OS10(config-pmap-c-que)# bandwidth percent <bandwidth-percentage> OS10(config-pmap-c-que)# exit OS10(config-pmap-queuing)# class <iscsi-traffic-map-name> OS10(config-pmap-c-que)# bandwidth percent <bandwidth-percentage> OS10(config-pmap-c-que)# exit OS10(config-pmap-queuing)# exit Note: The sum of the bandwidth percentages must equal 100. Monitor the LAN and SAN performance in your environment to determine optimal bandwidth settings. 3.10 QoS policy system qos OS10(config-sys-qos)# service-policy input type qos <trust-policy-map-name> OS10(config-sys-qos)# service-policy type application <qos-policy-map-name> OS10(config-sys-qos)# ets mode on OS10(config-sys-qos)# exit 15 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Configure Data Center Bridging (DCB) (optional) 3.11 Apply policies and VLAN ID to all switch edge ports (except portchannel member ports) interface range ethernet 1/1/1-1/1/27,1/1/29,1/1/31-1/1/54 OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# switchport mode trunk OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# switchport trunk allowed vlan <vlan-id> OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# service-policy input type network-qos <policy-map-name> OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# service-policy output type queuing <queuing-policy-name> OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# ets mode on OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# qos-map traffic-class <queue-map-name> OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# priority-flow-control mode on OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# exit 3.12 Apply policies and VLAN ID on port channel and its member ports interface port-channel 1 OS10(conf-if-po-1)# switchport mode trunk OS10(conf-if-po-1)# switchport trunk allowed vlan <vlan-id> OS10(conf-if-po-1)# no shutdown OS10(conf-if-po-1)# exit This configuration guide uses ports 1/1/28 and 1/1/30 as port channel member ports. They are configured using the following commands. Note: All port channel member ports need to be of same speed. For example, when using 40GbE ports for the port channel, do not add any member ports with a different port speed such as 100GbE or 10GbE. interface range ethernet 1/1/28,1/1/30 OS10(conf-range-eth1/1/28,1/1/30)# service-policy input type network-qos <policy-map-name> OS10(conf-range-eth1/1/28,1/1/30)# service-policy output type queuing <queuingpolicy-name> OS10(conf-range-eth1/1/28,1/1/30)# ets mode on OS10(conf-range-eth1/1/28,1/1/30)# qos-map traffic-class <queue-map-name> OS10(conf-range-eth1/1/28,1/1/30)# priority-flow-control mode on OS10(conf-range-eth1/1/28,1/1/30)# exit exit 16 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Configure Data Center Bridging (DCB) (optional) 3.13 iscsi enable iscsi enable iscsi session-monitoring enable exit 3.14 Save configuration OS10# copy running-configuration startup-configuration 3.15 Show commands to verify DCBx, ETS, and PFC status on individual ports OS10# show lldp dcbx interface ethernet 1/1/<port-number> OS10# show lldp dcbx interface ethernet 1/1/<port-number> pfc detail OS10# show lldp dcbx interface ethernet 1/1/<port-number> ets detail 3.16 Configure additional switches Repeat the commands from section 3 to configure DCB on additional switches. 17 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Revert from DCB to non-dcb configuration (optional) 4 Revert from DCB to non-dcb configuration (optional) One method to revert from a DCB configured switch to a non-dcb configured switch is to delete the current configuration (startup-config) and follow the steps in section 2. If deleting the current configuration is not an option, use the following procedure to unconfigure DCB and enable standard flow control. Note: This is a disruptive operation that requires downtime. The arrays will temporarily lose communication with each other. Power off all arrays and hosts connected to the SAN before proceeding with these steps. 4.1 Disable DCB OS10# configure terminal no dcbx enable 4.2 Disable iscsi no iscsi enable no iscsi session-monitoring enable 4.3 Remove DCB policies and apply standard flow control on edge ports interface range ethernet 1/1/1-1/1/27,1/1/29,1/1/31-1/1/54 OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# no priority-flow-control OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# no qos-map traffic-class OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# no ets OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# no service-policy output type queuing <queuing-policy-name> OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# no service-policy input type network-qos <policy-map-name> OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# no switchport trunk allowed vlan <vlan-id> OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# no switchport mode OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# switchport mode access OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# flowcontrol receive on OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# flowcontrol transmit off OS10(conf-range-eth1/1/1-1/1/27,1/1/29,1/1/31-1/1/54)# exit 18 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Revert from DCB to non-dcb configuration (optional) 4.4 Remove DCB policies and apply standard flow control on portchannel member ports interface range ethernet 1/1/28,1/1/30 OS10(conf-range-eth1/1/28,1/1/30)# no priority-flow-control OS10(conf-range-eth1/1/28,1/1/30)# no ets OS10(conf-range-eth1/1/28,1/1/30)# no qos-map traffic-class OS10(conf-range-eth1/1/28,1/1/30)# no service-policy output type queuing <queuing-policy-name> OS10(conf-range-eth1/1/28,1/1/30)# no service-policy input type network-qos <policy-map-name> OS10(conf-range-eth1/1/28,1/1/30)# flowcontrol receive on OS10(conf-range-eth1/1/28,1/1/30)# flowcontrol transmit off OS10(conf-range-eth1/1/28,1/1/30)# exit interface port-channel 1 OS10(conf-if-po-1)# no switchport trunk allowed vlan <vlan-id> OS10(conf-if-po-1)# switchport access vlan 1 OS10(conf-if-po-1)# exit 4.5 Revert to default VLAN ID on switch and arrays Once DCB is disabled on the switch, the PS Series arrays will no longer use the VLAN ID that was configured when DCB was enabled. The arrays will revert to the default or native VLAN. Therefore, a valid VLAN must be configured for all host servers, switches, and PS Series array members. A valid VLAN can use the default or native VLAN ID (typically 0 or 1) or a specific VLAN can be configured (for example, VLAN 100). If a nondefault VLAN is configured, any ports connected to the arrays must be configured as untagged. The prior steps in sections 4.3 and 4.4 revert the switch ports to default native vlan 1. Use the following command to remove VLANs other than vlan 1 from the switch configuration. no interface vlan <vlan-id> 19 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Revert from DCB to non-dcb configuration (optional) 4.6 Remove ETS, PFC, and other policies from switch configuration no policy-map type queuing <queuing-policy-name> no class-map type queuing <LAN-traffic-map-name> no class-map type queuing <iscsi-traffic-map-name> system qos OS10(config-sys-qos)# no ets OS10(config-sys-qos)# no service-policy input type qos <trust-policy-map-name> OS10(config-sys-qos)# no service-policy type application <qos-policy-map-name> OS10(config-sys-qos)# exit no policy-map type network-qos <policy-map-name> no policy-map type qos <trust-policy-map-name> policy-map type application <qos-policy-map-name> OS10(config-pmap-application)# no class class-iscsi OS10(config-pmap-application)# exit no qos-map traffic-class <queue-map-name> no class-map type network-qos <iscsi-class-map-name> no class-map type application <qos-policy-map-name> 4.7 iscsi enable iscsi enable iscsi session-monitoring enable exit 4.8 Save configuration OS10# copy running-configuration startup-configuration 4.9 Reload OS10# reload Proceed to reboot the system? [confirm yes/no]:yes Note: The switch will reboot. 4.10 Verify DCB status OS10# show lldp dcbx interface ethernet 1/1/<port-number> 4.11 Configure additional switch Repeat the commands from section 4 to disable DCB on any additional switches. 20 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703

Technical support and resources A Technical support and resources Dell.com/support is focused on meeting customer needs with proven services and support. Dell TechCenter is an online technical community where IT professionals have access to numerous resources for Dell EMC software, hardware, and services. Storage Solutions Technical Documents on Dell TechCenter provide expertise that helps to ensure customer success on Dell EMC storage platforms. A.1 Related resources Referenced or recommended publications: Dell PS Series Configuration Guide Dell EMC Storage Compatibility Matrix For PS Series best practices white papers, reference architectures, and sizing guidelines for enterprise applications and SANs, refer to PS Series Technical Documents. 21 Dell EMC Networking S4148-ON and S4128-ON Switch Configuration Guide for Dell PS Series SANs SCG3703