Data Cable for GSP-2900 Fixed Satellite Phone. Installation Instructions. Revised July 2004

Similar documents
1993 SPECIFICATIONS CSJ , ETC. & SPECIAL SPECIFICATION ITEM 6132 ARTERIAL TRAFFIC MANAGEMENT SYSTEM

1. Mount the echo and tremolo control switches under the keyboard shelf, in a position convenient for the organist.

Integrated Battery Control System LBCS Step-by-Step Setup Guide

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

Product Manual. USB BAY-4 Port Serial DB- 9 RS-232 Adapter with FTDI Chipset. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-BAY4

Appendix A Cable Pinouts

Cable Pinouts. SRP I/O Module

Connector and Cable Specifications

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

Product Manual. USB 2.0 to Serial High- Speed RS-232 Industrial Adapter. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-COM-M

Installation Manual. Table of Contents

USB Port USB Serial DB-9 RS-232 Adapter FTDI Chipset. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USB2-4COM-M

Mini USB to RS-232 Serial Adapter DB-9 Male Converter. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USBG-232MINI.

-C5RS-LC RS232 EXTENDER

ST-C5VRS-600 VIDEO AND RS232 EXTENDER Installation and Operation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Megatouch FORCE Monitor Chassis Board Replacement

Bluetooth TO Serial CONVERTER E-P132-B

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999

Cable and Port Specifications

Bluetooth to RS-232 Converter. RT-132B Bluetooth Adaptor Operation Manual

Cable and Port Specifications

RS-232 Driver Module

Older Compaq UPS Family - Identifying Serial Communication Cables

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

Hardware Manual PCMCIA DUAL RS EDITION MAY 1999

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

ME778C-RJ45 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-45. Line: RJ-45 INTERFACE MODULE (REAR CARD) Serial: 10-Pin RJ.

Service & Maintenance

Voice Evacuation Control Panel Main Circuit Board Replacement Product Installation Document

Building the Communication Cable

Installation Instructions

Serial Link Generic Tank Mode Installation Manual. Pro Fuel Management System. RE Rev C July 00

SuperBus 2000 Phone Interface/Voice Module Installation Instructions

ICP PANEL-TEC PEX3000 II

MultiConnect Adapters

8 Port USB to RS- 232/422/485 Octal Adapter. Product Manual. Coolgear, Inc. Version 1.1 April 2018 Model Number: USB-8COMi-RM.

DIN Rail Mounted Dial-up Modem Users Manual

Enclosure TS-530 User Manual

6 foot USB to RS-232 Serial Adapter DB-9 Male, FTDI Chipset. Product Manual. Coolgear Version 1.0 January 2018 Model Number: USBG-232MM

Instructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only)

721EX Access Controller Installation

Installing the Cisco AS5400XM Universal Gateway

ANC Series RS-422 Serial Communications Adapter

Perle SMI Media Converter Installation Guide

USB to DB25 RS232 Adapter User Manual. Features. Windows 7/ Vista / 2003 / XP / 2000 Driver Installation

3G Cell Modem Installation and User Guide

USER MANUAL. MODEL 1018 High Speed Short Range Modem w/ Extra Controls SALES OFFICE (301) TECHNICAL SUPPORT (301)

DGH A3000 Configuration Guide For use with DGH Modules

Wrenchman, Inc Old Hwy. # 8 Suite # 122 New Brighton, Minnesota (651)

Product Manual. 8-Port RS-232 USB to Serial Adapter Data Control Box. Coolgear, Inc. Version 1.1 September 2017 Model Number: USB-8COM

NPort S8000 Series Quick Installation Guide

Quick Installation Guide

INSTALLATION INSTRUCTIONS

USER MANUAL FOR GS100/GS1003G

DATA CONNECT ENTERPRISE

24-Port Gigabit Ethernet Switches

Optical Multiplexer. Quick Start Guide

Installation Instructions

ANIxx. Installation Manual.

Quick Installation Guide

SC532A 9-PIN PERIPHERAL TO RS232 INTERFACE INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS

Model:UT-8814 USB/RS-232 Commercial interface converter. Instruction Manual

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

8-Port RS-232 PCIe Card

Installation OVERVIEW

Product Manual. Single Port RS-232 USB Serial Adapter Optical- ISO Surge Protection. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-COM-Si-M

ZLAN5200. User Manual

ME930C-RJ11 MAIN MODULE (FRONT CARD) MAIN MODULE. Line: RJ-11 INTERFACE MODULE (REAR CARD) Serial: DB25 CONN. SW1 RJ-11 CONN.

Module Connectors and Cable Specifications

Lightning Stitch Assembly

Installation and Configuration Quick Guide GoRugged M1000 MP

ETH-4X1-G / 2X1-G / 2X1

ZM24x Quick-Connect Industrial Modem. User s Manual

USB-COM Plus ISO (USB-COMi SI-M)

The Analyst. RS422/RS232 Tester. (Standard Model) User Manual

Product Manual. 2 Port USB to RS-422 /485 Optical Isolated Adapter. Coolgear, Inc. Version 1.1 March 2018 Model Number: USB-2COMi-Si-M

BeagleBone Black USB Expansion RS232 Module Cape Coolgear, Inc. Version 1.1 September 2017 Model Number:

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version

Quick Installation Guide

NPort 6150/6250 Series Quick Installation Guide

USER MANUAL HPS-120. About this product: Your Communications Solutions Provider

Sender Receiver Sender

CC186 AND CC186/2 STAND-ALONE OR SYSTEM CLOCK

INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS)

InnoMedia ipbx-400. Quick Install Guide.

Replacing the Power Supply

Removing and Replacing Parts

Users Manual Ocean Sensor Systems Wave Staff III

FC-25/50DA Main Circuit Board Replacement Product Installation Document

Cable and Port Specifications

Power connections 3) Power from 2024 to Control box (The valve harness connected) Ground (0V) +24 V. The voltage between pins 1 & 2 in JPT# 123

EP/2 Installation Instructions

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

Cable Specifications. Interface Specifications. Fiber-Optic Specifications APPENDIXB

USER MANUAL. MODEL 1000P Non-Powered Short Haul Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Installation Instructions for: Channel Thermocouple Amplifier

FP-1000PW. Thermal Printer User s Manual. Fujitsu Isotec Limited. KA02066-Y Standard Model Built-in Power Supply Model FP-1000

Transcription:

Data Cable for GSP-2900 Fixed Satellite Phone Installation Instructions Revised July 2004 1

This document provides step-by-step instructions enabling the user to install the GSP- 2900 Data Cable Kit. 1. Determine that the GSP-2900 contains software version 5.1.2.2A or higher. If this software is not present, the GSP-2900 it will not be data capable. Contact your point of purchase or Globalstar Customer Care for more information. 2. Disconnect power from the GSP-2900 by removing the power cord from the outlet AND disconnecting the backup battery. 3. Remove the front cover of the GSP-2900 by loosening the four thumbscrews (black in colour) this will allow access to the interface board. 4. Locate the small five-pin header connector on the board. (See picture below) and connect the mating 5 pin connector on the FUT data cable to the header. Ensure that the polarity is correct. Do not force, as breakage will result. Plug the RJ-11 male into the Telco test jack on the side of the interface board. 2

5. It is necessary to route both the power/rj-11 (phone) and data cables out of the FUT through the same opening. Disconnect the black power/rj-11 cable. Next, remove the Philips screw holding the P clip strain relief in place, and remove the red rubber grommet from the cable. Install the supplied P clip onto the FUT data cable, and position it with the flat side facing you. Reinstall the metal P clip on the black power/rj-11 cable with the flat side away from you. Install the Philips screw through both P clips and tighten securely. 6. Apply RTV silicone sealant to waterproof the cable exit area.(important) 7. Reconnect the power and RJ-11 wires to the 4 place terminal block 8. Replace the cover on the GSP-2900 and tighten the four thumbscrews securely. 9. Route the data cable along with the power/rj-11 cable to the NID (Network Interconnect Device) box mounting location. 10. Mount the gray NID (Network Interconnect Device) in a convenient location near the existing power/rj-11 NID. 3

11. Open the inner cover on the NID (Network Interconnect Device) to facilitate ground connection 12. It is vital to ground the NID (Network Interconnect Device) to prevent lightning and/or static discharge from damaging your computer equipment. See picture below for location of ground wire in NID box. The ground wire should be a solid copper wire of at least 12 gauge. This wire should be connected to a ground rod or copper water pipe, which is buried in the ground. 13. Once proper ground connection is completed, close the inner door and secure with 3/8 nut driver or socket. 14. Connect a serial cable to the female DB-9 provided in the NID box. This cable should be routed through the black rubber grommet on the lower right side of the NID. Proper strain relief should also be applied (ty-rap) The serial cable should be NO MORE than 60 feet (18.3 Meters) between the computer and the GSP-2900. Longer cables may cause data errors and reduced performance. You may use a Category 5 type of cable with the necessary connectors to increase distance between the GSP-2900 and your computer. 4

For extremely long distances a RS-422 to RS-232 balanced line converter may be required. 15. Re-connect the back-up battery and power supply. Ensure that the GSP-2900 is working correctly by listening for dial tone on the desk set. You may also place a test call to verify proper operation. Dial #8378 to access a toll free voice only test number from within the N. American service area. 16. Install the Globalstar packet data modem driver using the provided CD. The baud rate between the GSP-2900 and computer MUST be set at 19200 for the computer to communicate with the GSP-2900. The CD for GSP-2900 will configure this setting automatically. For Windows XP you must install the modem driver manually. Contact Globalstar or your local dealer for support. 17. Connect to Globalstar Data Services by dialing #777 from the computer via Dial up Networking Schematic Diagram of Data Cable NID box for static and lightning discharge protection. Must be grounded!!! DB-9 Female connector (In NID Box) RJ-11 1 RI 4 RLSD AMP 5 pin Header 1 GND 2 TXD 3 RXD 4 RTS 5 CTS NID BOX (grey) DB-9 female in NID box 5 = GND 3 = RXD 2 = TXD 7 = CTS 8 = RTS 1 = RLSD 9 = RI Pin outs for DB-9 Shown Connections shown are on interface board in GSP-2900 Must be connected to earth ground. Ground wire to be supplied by Customer/Installer 5