Model INSTRUCTION MANUAL DIGITAL MULTIMETER

Similar documents
OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER MAS830 MAS830L

ETHOS Auto Ranging Digital Multimeter

Mini Digital Multimeter

POCKET MULTIMETER Model No: MM18

OPERATING INSTRUCTION

Mini Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Digital Multimeter User's Manual

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

Autoranging True RMS Multimeter User Manual

Mini Digital Multimeter Model MN15. User's Guide

Mini Digital Multimeter

Model A Mini AC/DC Clamp Meter. User's Guide

2 in 1 LAN Tester and Multimeter Model:

User's Guide. Digital Multimeter. Model MN42

Autoranging Mini Multimeter

7032 Digital-Analog Multimeter

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Model R5010. TRMS Digital Multimeter. Instruction Manual

USER MANUAL. True RMS Multimeter. Extech EX430A

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

AutoRanging Digital MultiMeter

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

User Guide True RMS Multimeter Extech EX205T

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

Bench Multimeter. Users Manual

User s Guide. 600A AC Clamp Meter. Model 38387

MS2115B Dual Display Digital Clamp Meter Operation Manual ZERO MIN RANGE HOLD

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

True RMS Digital Bench Multimeter Model:

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

WARNING CAUTION 1. SAFETY

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

User's Guide. Digital Multimeter plus IR Thermometer. Extech 450 Patented

Autoranging Multimeter Extech EX503

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

USER MANUAL. True RMS Multimeter plus IR Thermometer. Extech EX470A

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patent Pending

Mini Multimeter with Non-Contact Voltage Detector (NCV)

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patented

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

True RMS Industrial Multimeter Extech EX520

Industrial Multimeter Extech EX510

True RMS Multimeter with IR Thermometer

TENMA INSTRUCTION MANUAL MULTI-TESTER

Autoranging Mini Multimeter Model MN16A

True RMS Multimeter with IR Thermometer

700 Series 200 Amp Clamp Meters

Digital Clamp Meter User Manual

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

DIGITAL MULTIMETER 4 1/2 digits, True RMS Model : DM-9027T

Variable Temperature Digital Solder and Testing Station

True RMS Industrial Multimeter Extech EX530

Digital Clamp-on Meter Instruction Manual

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

True RMS Multimeter with IR Thermometer

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

Digital Multimeter Instruction Manual

Digital Clamp-on Meter Amp Plus. Instruction Manual

Monarch Instrument 2002 all rights reserved MONARCH INSTRUMENT. True RMS Multimeter. Instruction Manual. Monarch 120

Digital Clamp-on Meter Instruction Manual

Model OPERATING MANUAL

User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer

Wireless TRMS Multimeter and Insulation Tester

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

USER'S MANUAL DCL-650

Wireless TRMS Multimeter

User's Guide. Extech AM A AC Analog Clamp Meter

SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide

DC / AC True RMS Watt Clamp DMM

AC/DC TRUE RMS CLAMP METER ACM-2036

MTP INSTRUCTION MANUAL

Model 3526-B Digi-Probe Multimeter

Digital Clamp-on Meter Amp Plus. Instruction Manual

Wireless TRMS Multimeter and Insulation Tester

9040/9040UK. Users Manual. Phase Rotation Indicator

Wireless TRMS Multimeter

Model. True RMSmA Clamp Meter. Instruction Manual

OPERATING MANUAL INDUSTRIAL MULTIMETER CMM-40

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

EARTH RESISTANCE & RESISTIVITY TESTER

Earth Resistance and Resistivity Tester

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

High Precision Quad Output DC Power Supply

Elma 5800 English usermanual Page 35-49

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

W Warning To avoid electrical shock, remove test leads and any input signals from the Model 707 Loop Calibrator before opening the case.

Digital Clamp-on Meter Instruction Manual

Transcription:

Model 57040 INSTRUCTION MANUAL DIGITAL MULTIMETER

SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CAT ) and pollution 2. Follow all safety and operating instructions to ensure that the meter is used safely and is kept in good operating condition. Full compliance with safety standards can be guaranteed only with test leads supplied. If necessary, they must be replaced with the type specified in this manual. SAFETY SYMBOLS Important safety information, refer to the operating manual. Dangerous voltage may be present. Earth ground. Double insulation (Protection class II). Fuse must be replaced with rating specified in the manual. MAINTENANCE Before opening the case, always disconnect test leads from all energized circuits. For continued protection against fire; replace fuse only with the specified voltage and current ratings: F 200mA/250V(Quick Acting) Never use the meter unless the back cover is in place and fastened completely. Do not use abrasives or solvents on the meter. Clean using a damp cloth and mild detergent only. -1-

DURING USE Never exceed the protection limit values indicated in specifications for each range of measurement. When the meter is linked to measurement circuit, do not touch unused terminals. Never use the meter to measure voltages that might exceed 600V above earth ground in category installations. When the value scale to be measured is unknown beforehand, set range selector at the highest position. Before rotating the range selector to change functions, disconnect test leads from the circuit under test. When carrying out measurements on TV s or switching power circuits, always remember that there may be high amplitude voltage pulses at test points, which can damage the meter. Always is careful when working with voltages above 60V dc or 30V ac rms. Keep fingers behind the probe barriers while measuring. Before attempting to insert transistors for testing, always be sure that test leads have been disconnected from any measurement circuits. Components should not be connected to the hfe socket when making voltage measurements with test leads. Never perform resistance measurements on live circuits. GENERAL DESCRIPTION The meter is a battery operated handheld 3-1/2 digital multimeter for measuring DC and AC voltage, DC current, Resistance, Diode, Transistor, Temperature and Continuity Test. -2-

FRONT PANEL -3-

FRONT PANEL DESCRIPTION Display 3 1/2 digit, 7 segment, 15mm high LCD. Rotary switch This switch is used to select functions and desired ranges as well as to turn on/off the meter. Hold button When this button is pushed, the display will keep the last reading and symbol will appear on the LCD until pushing it again. 10A jack Plug in red test lead connector for 10A measurement. COM jack Plug in connector for black (negative) test lead or plug in the black plug with k type thermocouple. V ma jack Plug in connector for red (positive) test lead for voltage, resistance and current (except 10A) measurements or plug in the red plug with k type thermocouple. SPECIFICATIONS Accuracy is specified for a period of one year after calibration and at 18 to 28 (64 F to 82 F) with relative humidity to 80%. GENERAL Maximum voltage between :CAT 600V terminals and earth ground Fuse protection :F 200mA/250V Power :9V battery, NEDA 1604 or 6F22 Display : LCD, 1999 counts, updates 2-3/ sec. Measuring method :Dual-slope integration A/D converter Overrange Indication :Only figure 1 on the display Polarity indication : - displayed for negative polarity Operating Environment :0 to 40 Storage temperature :-10 to 50. -4-

Low battery indication : appears on the display Size :138mm 69mm 31mm Weight : Approx.170g. DC VOLTAGE Range Resolution Accuracy 200mV 100 V 0.5% of rdg 2 digits 2V 1mV 0.5% of rdg 2 digits 20V 10mV 0.5% of rdg 2 digits 200V 100mV 0.5% of rdg 2 digits 600V 1V 0.8% of rdg 2 digits Overload Protection: 250V rms. For 200mV range and 600V dc or rms. ac for other ranges. DC CURRENT Range Resolution Accuracy 2mA 1 A 1% of rdg 2 digits 20mA 10 A 1% of rdg 2 digits 200mA 100 A 1.5% of rdg 2 digits 10A 10mA 3% of rdg 2 digits Overload Protection: F 200mA/250V fuse. (10A range unfused) AC VOLTAGE Range Resolution Accuracy 200V 100mV 1.2 % of rdg 10 digits 600V 1V 1.2 % of rdg 10 digits Overload Protection: 600V dc or rms. ac for all ranges. Frequency range: 40Hz to 400Hz. Response: Average responding, calibrated in rms. of a sine wave. DIODE & CONTINUITY Range Description If continuity exists (about less than 1.5k ), built-in buzzer will sound. Show the approx. forward voltage drop of the diode. Overload Protection: 250V dc or rms. ac. -5-

TRANSISTOR hfe TEST (0-1000) Range Test Range Test Current Test Voltage NPN & PNP 0-1000 Ib=10 A Vce=3V RESISTANCE Range Resolution Accuracy 200 0.1 0.8% of rdg 3 digits 2k 1 0.8% of rdg 2 digits 20k 10 0.8% of rdg 2 digits 200k 100 0.8% of rdg 2 digits 2M 1k 1.0% of rdg 2 digits Maximum Open Circuit Voltage: 3.2V Overload Protection: 250V dc or rms. ac for all ranges. TEMPERATURE Range Resolution Test Range Accuracy 1-20 to 0-0 to 400 400 to 1000 10% of rdg 2digits 1.0% of rdg 3digits 2.0% of rdg TEMPERATURE Range Resolution Test Range Accuracy F 1 F -4 F to 32 F 32 F to 752 F 752 F to 1832 F 10% of rdg 2digits 1.0% of rdg 3digits 2.0% of rdg OPERATING INSTRUCTIONS DC VOLTAGE MEASUREMENT 1. Connect the red test lead to the V..mA jack and the black lead to the COM jack. 2. Set rotary switch at desired DCV position. If the voltage to be measured is not known beforehand, set range switch at the highest range position and then reduce it until satisfactory resolution is obtained. 3. Connect test leads across the source or load being measured. 4. Read voltage value on the LCD display along with the polarity of the red lead connection. -6-

DC CURRENT MEASUREMENT 1. Connect the red test lead to the V..mA jack & the black test lead to COM jack. (For measurements between 200mA & 10A, remove red lead to 10A jack.) 2. Set the rotary switch at desired DCA position. 3. Open the circuit in which the current is to be measured, and connect test leads in series with the circuit. 4. Read current value on LCD display along with the polarity of red lead connection. AC VOLTAGE MEASUREMENT 1. Connect the red test lead to V.. ma jack and the black test lead to the COM jack. 2. Set the rotary switch at desired ACV position. 3. Connect test leads across the source or load being measured. Read voltage value on the LCD display. 4. DIODE TEST 1. 2. 3. Connect the red test lead to V..mA jack and the black test lead to the COM jack (The polarity of red lead is positive +.). Set the rotary switch at position. Connect the red test lead to the anode of the diode to be tested and the black test lead to the cathode of the diode. The approx. forward voltage drop of the diode will be displayed. If the connection is reversed only figure 1 will be shown. TRANSISTOR TEST 1. Set the rotary switch at hfe position. 2. Determine whether the transistor under testing is NPN or PNP and locate the emitter base and collector leads. Insert the leads into proper holes of the hfe socket on the front panel. 3. Read the approximate hfe value at the test condition of base current 10 A and Vce 3V. -7-

RESISTANCE MEASUREMENT 1. Connect the red test lead to V.. ma jack and black test lead to the COM jack. (The polarity of red lead is positive +.) 2. Set the rotary switch at desired range position. 3. Connect test leads across the resistor to be measured and read LCD display. 4. If the resistance being measured is connected to a circuit, turn off power and discharge all capacitors before applying test probes. AUDIBLE CONTINUITY TEST 1. Connect red test lead to V..mA, black test lead to 2. 3. COM. Set range switch to position. Connect test leads to two points of circuit to be tested. If continuity exists, built-in buzzer will sound. MEASURING TEMPERATURE 1. If the meter is the function, set the rotary switch at. Position. If it is the F function, set the rotary switch at F Position. The LCD display will show the current environment temperature. 2. Connect the red lead of K type thermocouple into the V..mA jack and the black lead of K type thermocouple into the COM jack. 3. Read temperature value on the LCD display. WARNING: To avoid electric shock, be sure the thermocouple has been removed before changing to another function measurement. BATTERY & FUSE REPLACEMENT If appears on display, it indicates that the battery should be replaced. Fuse rarely needs replacement and blows almost always as a result of operator s error. To replace battery fuse (200mA/250V), remove the 2 screws in the bottom of the case. Simply remove old battery and replace with a new one. Be careful to observe battery polarity. -8-

WARNING Before attempting to open the case, always be sure that test leads have been disconnected from measurement circuits. Close case and tighten screws completely before using the meter to avoid electrical shock hazard. ACCESSORIES Operator s instruction manual Set of test leads 9 volt battery. NEDA 1604 6F22 type K type thermocouple Holster