OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER MAS830 MAS830L

Similar documents
OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

ETHOS Auto Ranging Digital Multimeter

POCKET MULTIMETER Model No: MM18

Mini Digital Multimeter

Mini Digital Multimeter

OPERATING INSTRUCTION

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Autoranging True RMS Multimeter User Manual

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

Digital Multimeter User's Manual

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

Mini Digital Multimeter Model MN15. User's Guide

2 in 1 LAN Tester and Multimeter Model:

User's Guide. Digital Multimeter. Model MN42

Model A Mini AC/DC Clamp Meter. User's Guide

Mini Digital Multimeter

Model R5010. TRMS Digital Multimeter. Instruction Manual

USER MANUAL. True RMS Multimeter. Extech EX430A

Bench Multimeter. Users Manual

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Autoranging Mini Multimeter

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

User s Guide. 600A AC Clamp Meter. Model 38387

User Guide True RMS Multimeter Extech EX205T

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

AutoRanging Digital MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter

7032 Digital-Analog Multimeter

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

MS2115B Dual Display Digital Clamp Meter Operation Manual ZERO MIN RANGE HOLD

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

True RMS Digital Bench Multimeter Model:

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

Digital Clamp-on Meter Instruction Manual

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

User's Guide. Digital Multimeter plus IR Thermometer. Extech 450 Patented

Autoranging Multimeter Extech EX503

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

WARNING CAUTION 1. SAFETY

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Industrial Multimeter Extech EX510

True RMS Multimeter with IR Thermometer

True RMS Multimeter with IR Thermometer

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

USER MANUAL. True RMS Multimeter plus IR Thermometer. Extech EX470A

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patent Pending

Mini Multimeter with Non-Contact Voltage Detector (NCV)

True RMS Industrial Multimeter Extech EX520

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patented

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

Autoranging Mini Multimeter Model MN16A

Variable Temperature Digital Solder and Testing Station

Digital Clamp-on Meter Amp Plus. Instruction Manual

TENMA INSTRUCTION MANUAL MULTI-TESTER

Digital Multimeter Instruction Manual

DIGITAL MULTIMETER 4 1/2 digits, True RMS Model : DM-9027T

Digital Clamp-on Meter Instruction Manual

True RMS Industrial Multimeter Extech EX530

700 Series 200 Amp Clamp Meters

Digital Clamp Meter User Manual

Digital Clamp-on Meter Amp Plus. Instruction Manual

DC / AC True RMS Watt Clamp DMM

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

True RMS Multimeter with IR Thermometer

User's Guide. Extech AM A AC Analog Clamp Meter

Monarch Instrument 2002 all rights reserved MONARCH INSTRUMENT. True RMS Multimeter. Instruction Manual. Monarch 120

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

Wireless TRMS Multimeter

Model OPERATING MANUAL

Wireless TRMS Multimeter and Insulation Tester

Model 3526-B Digi-Probe Multimeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

MTP INSTRUCTION MANUAL

Wireless TRMS Multimeter and Insulation Tester

SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide

AC/DC TRUE RMS CLAMP METER ACM-2036

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

Wireless TRMS Multimeter

Model UT371/372 OPERATING MANUAL

EARTH RESISTANCE & RESISTIVITY TESTER

OPERATING MANUAL INDUSTRIAL MULTIMETER CMM-40

9040/9040UK. Users Manual. Phase Rotation Indicator

User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

High Precision Quad Output DC Power Supply

USER'S MANUAL DCL-650

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

Earth Resistance and Resistivity Tester

Model. True RMSmA Clamp Meter. Instruction Manual

Digital Clamp-on Meter Instruction Manual

Digital Clamp-on Meter Instruction Manual

Transcription:

OPERATOR S INSTRUCTION MANUAL MAS830 MAS830L DIGITAL MULTIMETER

SAFETY INFORMATION This multimeter has been designed according to IEC -1010 concerning electronic measuring instruments with an overvoltage category (CATⅡ) and pollution 2. Follow all safety and operating instructions to ensure that the meter is used safely and is kept in good operating condition. Full compliance with safety standards can be guaranteed only with test leads supplied. If necessary, they must be replaced with the type specified in this manual. SAFETY SYMBOLS Important safety information, refer to the operating manual. Dangerous voltage may be present. Earth ground. Double insulation (Protection class II). CAT II Fuse must be replaced with rating specified in the manual. Measurement category II, it is for measurements performed on circuits directly connected to the low voltage installation. MAINTENANCE Before opening the case, always disconnect test leads from all energized circuits. For continue protection against fire; replace fuse only with the specified voltage and current ratings: F 200mA/250V(Quick Acting) Never use the meter unless the back cover is in place and fastened completely. Do not use abrasives or solvents on the meter. To clean it using a damp cloth and mild detergent only. -1-

DURING USE Never exceed the protection limit values indicated in specifications for each range of measurement. When the meter is linked to measurement circuit, do not touch unused terminals. Never use the meter to measure voltages that might exceed 600V above earth ground in category Ⅱ installations. When the value scale to be measured is unknown beforehand, set the range selector at the highest position. Before rotating the range selector to change functions, disconnect test leads from the circuit under test. When carrying out measurements on TV or switching power circuits always remember that there may be high amplitude voltages pulses at test points, which can damage the meter. Always is careful when working with voltages above 60V dc or 30V ac rms. Keep fingers behind the probe barriers while measuring. Before attempting to insert transistors for testing, always be sure that test leads have been disconnected from any measurement circuits. Components should not be connected to the hfe socket when making voltage measurements with test leads. Never perform resistance measurements on live circuits. GENERAL DESCRIPTION The meter is a portable 31/2 digital multimeter for measuring DC and AC voltage, DC current, Resistance, Diode, Transistor and Continuity Test with battery operated. The Back light of display is optional. -2-

FRONT PANEL -3-

FRONT PANEL DESCRIPTION Display 3 1/2 digit, 7 segment, 15mm high LCD. Back light (ONLY MAS830L) When this button is pushed, the Back light of display is on. After about 5 seconds, the Back light is self-off. The Back light is on again, just push this button once. ƒ Rotary switch This switch is used to select functions and desired ranges as well as to turn on/off the meter. Hold button When this button is pushed, the display will keep the last reading and symbol will appear on the LCD until pushing it again. 10A jack Plug in connector for red test lead for 10A measurement. COM jack Plug in connector for black (negative) test lead. VWmA jack Plug in connector for red (positive) test lead for voltage, resistance and current (except 10A) measurements. SPECIFICATIONS Accuracy is specified for a period of one year after calibration and at 18 to 28 (64 F to 82 F) with relative humidity to 80%. GENERAL Maximum voltage between :CATⅡ600V terminals and earth ground Fuse protection :F 200mA/250V Power :9V battery, NEDA 1604 or 6F22 Display : LCD, 1999 counts, updates 2-3/ sec. Measuring method :Dual-slope integration A/D converter Overrange Indication :Only figure 1 on the display Polarity indication : - displayed for negative polarity Operating Environment :0 to 40

-4- Storage temperature :-10 to 50. Low battery indication : appears on the display Size :138mm 69mm 31mm Weight : Approx.170g. DC VOLTAGE Range Resolution Accuracy 200mV 100mV ±0.5% of rdg ± 2 digits 2V 1mV ±0.5% of rdg ± 2 digits 20V 10mV ±0.5% of rdg ± 2 digits 200V 100mV ±0.5% of rdg ± 2 digits 600V 1V ±0.8% of rdg ± 2 digits Overload Protection: 250V rms. For 200mV range and 600V dc or rms. ac for other ranges. DC CURRENT Range Resolution Accuracy 200mA 0.1mA ±1% of rdg ± 2 digits 2mA 1mA ±1% of rdg ± 2 digits 20mA 10mA ±1% of rdg ± 2 digits 200mA 100mA ±1.5% of rdg ± 2 digits 10A 10mA ±3% of rdg ± 2 digits Overload Protection: F 200mA/250V fuse. (10A range unfused) AC VOLTAGE Range Resolution Accuracy 200V 100mV ±1.2 % of rdg ± 10 digits 600V 1V ±1.2 % of rdg ± 10 digits Overload Protection: 600V dc or rms. ac for all ranges. Frequency range: 40Hz to 400Hz. Response: Average responding, calibrated in rms. of a sine wave. DIODE & CONTINUITY Range Description If continuity exists (about less than 1.5kW), built-in buzzer will sound.

Show the approx. forward voltage drop of the diode. -5- Overload Protection: 250V dc or rms. ac. RESISTANCE Range Resolution Accuracy 200W 0.1W ±0.8% of rdg ± 3 digits 2kW 1W ±0.8% of rdg ± 2 digits 20kW 10W ±0.8% of rdg ± 2 digits 200kW 100W ±0.8% of rdg ± 2 digits 2MW 1kW ±1.0% of rdg ± 2 digits Maximum Open Circuit Voltage: 3.2V Overload Protection: 250V dc or rms. ac for all ranges. TRANSISTOR hfe TEST (0-1000) Range Test Range Test Current Test Voltage NPN & PNP 0-1000 Ib=10mA Vce=3V OPERATING INSTRUCTIONS DC VOLTAGE MEASUREMENT 1. Connect the red test lead to the V.W.mA jack and the black lead to the COM jack. 2. Set rotary switch at desired DCV position. If the voltage to be measured is not known beforehand, set range switch at the highest range position and then reduce it until satisfactory resolution is obtained. 3. Connect test leads across the source or load being measured. 4. Read voltage value on the LCD display along with the polarity of the red lead connection. DC CURRENT MEASUREMENT 1. Connect the red test lead to the V.W.mA jack and the black test lead to COM jack. (For measurements between 200mA and 10A, remove red lead to 10A 2. jack.) 3. Set the rotary switch at desired DCA position. Open the circuit in which the current is to be measured, 4. and connect test leads in series with the circuit. Read current value on LCD display along with the

polarity of red lead connection. -6- AC VOLTAGE MEASUREMENT 1. 2. 3. 4. Connect the red test lead to V.W. ma jack and the black test lead to the COM jack. Set the rotary switch at desired ACV position. Connect test leads across the source or load being measured. Read voltage value on the LCD display. RESISTANCE MEASUREMENT 1. Connect the red test lead to V. W. ma jack and black test lead to the COM jack. (The polarity of red lead is positive +.) 2. Set the rotary switch at desired W range position. 3. Connect test leads across the resistor to be measured and read LCD display. 4. If the resistance being measured is connected to a circuit, turn off power and discharge all capacitors before applying test probes. DIODE TEST 1. Connect the red test lead to V.W.mA jack and the black test lead to the COM jack (The polarity of red lead is positive +.). 2. Set the rotary switch at position. 3. Connect the red test lead to the anode of the diode to be tested and the black test lead to the cathode of the diode. The approx. forward voltage drop of the diode will be displayed. If the connection is reversed,only figure 1 will be shown. TRANSISTOR TEST 1. Set the rotary switch at hfe position. 2. Determine whether the transistor under testing is NPN or PNP and locate the emitter,base and collector leads. Insert the leads into proper holes of the hfe socket on the front panel. 3. Read the approximate hfe value at the test condition of

base current 10mA and Vce 3V. -7- NOTE: To avoid electrical shock, remove test leads from measurement circuits before testing a transistor. AUDIBLE CONTINUITY TEST 1. Connect red test lead to V.W.mA, black test lead to 2. COM. Set range switch to position. 3. Connect test leads to two points of circuit to be tested. If continuity exists, built-in buzzer will sound. BATTERY & FUSE REPLACEMENT If appears on display, it indicates that the battery should be replaced. Fuse rarely need replacement and blow almost always as a result of operator s error. To replace battery & fuse (200mA/250V) remove the 2 screws in the bottom of the case. Simply remove the old, and replace with a new one. Be careful to observe battery polarity. WARNING Before attempting to open the case, always be sure that test leads have been disconnected from measurement circuits. Close case and tighten screws completely before using the meter to avoid electrical shock hazard. ACCESSORIES Operator s instruction manual Set of test leads Gift box 9 volt battery. NEDA 1604 6F22 006P type Holster (option)

-8- CAUTION: Using this appliance in an environment with a strong radiated radio-frequency electromagnetic field (approximately 3V/m), may influence its measuring accuracy. The measuring result can be strongly deviating from the actual value. If there is any cracking or break shown on the enclosure or cable please do stop use it. Never use the meter to measure current if the circult to be measured might contain voltage exceeding 250V. PRECISION MASTECH ENTERPRISES CO. Room 1708-09, Hewlett Centre, 54 Hoi Yuen Road, Kwun Tong, Kowloon, Hong Kong. Tel: 852-23430007 Fax:852-23436217 E-mail: info@p-mastech.com SHENZHEN HUAYI MASTECH CO., LTD. East Wing, 8/F., Block 4, Saige Science and Technology Industrial Garden, Hua Qiang Bei Rd. Shenzhen Tel: 0755-83769588 Fax: 0755-83768150 E-mail: info@mastech.com.cn DONGGUAN HUAYI MASTECH CO., LTD. Yulianwei Industrial Area, Qingxi Town, Dongguan, China Tel: 0769-7318228 Fax: 0769-7318225 â

HYS004608 A1