Fieldbus Independent I/O Modules 4 AI Pt100/ RTD , (/xxx-xxx) Manual

Similar documents
Fieldbus Independent I/O Modules 2 AI 4-20 ma, Single-Ended Manual

Fieldbus Independent I/O Modules 8 DI DC 24 V 3.0 ms, Manual

Fieldbus Independent I/O Modules 4 AI DC 0-10 V, Single-Ended Manual

Fieldbus Independent I/O Modules 1 AI DMS Manual

Fieldbus Independent I/O Modules 2 DI DC 24 V 3.0 ms, High-Side Switching (/xxx-xxx) Manual

Fieldbus Independent I/O Modules SSI Transmitter Interface Manual

Fieldbus Independent I/O Modules 4 DO DC 24 V 0.5 A, High-Side Switching (/xxx-xxx)

Fieldbus Independent I/O Modules End Module (/xxx-xxx) Manual

Fieldbus Independent I/O Modules Field Side Connection Manual

Fieldbus Independent I/O Modules 24 V DC Power Supply/Fuse/Diagn Manual

Fieldbus Independent I/O Modules 2 AO 4-20 ma Manual

Fieldbus Independent I/O Modules Bluetooth RF Transceiver Quick Start

Fieldbus Independent I/O Modules Serial Interface RS 232 C (/xxx-xxx) Manual

WAGO Remote IO with Fanuc Robot using EtherNet/IP Protocol Application note

Redundant ethernet communication with WAGO Ethernet-Controller Application note

Using WAGO Series 750 DeviceNet IO with an A-B ControlLogix 1756-DNB Scanner Application note

Using WAGO Series 750 DeviceNet IO with an A-B SLC SDN Scanner Application note

Using the WAGO as Remote I/O with an Omron SYSMAC CJ2 Series PLC. Application note. A116700, English Version 1.1.0

Using the WAGO as Remote I/O with a ControlLogix Ethernet/IP Bridge Module Application note

Manual Version WAGO TO-PASS 761. Telecontrol Modules. 761-xxx. System Description

Configuring National Instruments Lab View with WAGO I/O Application note

Using WAGO Series 750 EtherCAT coupler with CoDeSys SP Win V3 Application note

Application Note. Building. Automation WAGO-I/O-PRO V2.3. openvpn with Linux based Devices A500880_en. Version 1.1.1

Library for Building Automation. Module Descriptions for KNX IP Master

Application note. WAGO-I/O-SYSTEM 750 DALI Multi-Master Module Configuration of a DALI Lighting System via WAGO- I/O-PRO V2.

Application Note. WAGO-I/O-SYSTEM 750 Connecting energy meters with M-Bus interface to the WAGO-I/O-SYSTEM

The HART Module on the WAGO ETHERNET Controller Application Note

Safety I/O Modules PROFIsafe 4FDO 0,5A/4FDI 24V DC PROFIsafe / Manual

Application Note. a HART Tool-routing with Emerson AMS HART over TH LINK PROFIBUS for Asset Management 1.0.0

Using the WagoAppEtherNetIP_Adapter library with a CompactLogix Controller A500930

Application Note. Connection of an WAGO ETHERNET Coupler/Controller to a S controller

WAGO-I/O-SYSTEM 750 CODESYS-2-Library WagoLibWakeOnLan.lib Wake on lan Remote wake up of network devices

Quick Install Manual BACnet /IP Controller

Manual. WAGO-I/O-SYSTEM DI 24VDC 3.0ms Channel Digital Input Module 24 V DC, High-side switching. Version 1.1.0

Fieldbus Independent I/O Modules Incremental Encoder Interface Manual

Port 100Base-TX Industrial Eco Switch

Library Description. DALI_647_SpecialSensor_02.lib Specific Sensor Solutions. Version 1.0.1

WAGO-I/O-SYSTEM 750 2DI 24V DC VDC,

Application Note. Enable port forwarding for PFC. A500840, English Version 1.0.0

Manual / Electronic Circuit Breaker DC 24 V, A. Version 1.0.0

Fieldbus Independent I/O Modules DALI/DSI Master Module Manual

Libraries for Building Automation. Function Blocks and Data Types for the BACnet Controller

Libraries for Building Automation. Module Descriptions for the WINSTA Sunblind Box /

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

M-BUS MASTER OEM MODULE MBUS-M13

Using PROFIsafe modules in combination with PROFIBUS-DP and PROFINET Application note

Documentation. KM10xx. Terminal Modules with Digital Inputs. Version: Date:

Documentation. KM2604 and KM2614. Four channel relay module. Version: Date:

AI561 Analog Input Module

Manual. WAGO-I/O-SYSTEM 750 CANopen ECO Fieldbus Coupler MCS kbaud... 1 MBaud; digital and analog signals 2.0.0

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

DeviceNet TM Fieldbus Coupler 125 Kbaud Kbaud; digital and analog signals

MINI MCR-SL-UI-2I(-SP)(-NC)

Library for Building Automation. Function block descriptions for time- switching functions

Library Description. MBUS_649_01.lib WAGO M-Bus Library. Version 1.0.1

Library for Building Automation

MINI MCR-SL-PT100-UI(-SP)(-NC)

Documentation KM2002, KM2004, KM2008. Terminal modules with digital outputs, 24 V, 0.5 A. Version: Date:

PROFIsafe modules V2 ipar 75x-66x/ WAGO Safety-Editor-75x Quickstart

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

AX521 Analog Input/Output Module

MINI MCR-SL-UI-REL(-SP)

AO561 Analog Output Module

This data sheet is only valid in association with the IL SYS INST UM E user manual.

WagoLib_CAN_Gateway_02.lib

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

AX522 Analog Input/Output Module

AO523 Analog Input Module

Modular I/O System. DeviceNet

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

CU port USB 2.0 hub. Version: 1.1 Date:

MINI MCR-SL-PT100-UI-200

Using power measurement module with TIA A500671

Documentation KL channel Digital Output Terminal, 24 V DC, 2 x 4 A/1 x 8 A. Version: Date:

Libraries for Building Automation. Function Block Description for DALI Multi-Master Module

MINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description

Library for Building Automation. Library Description for for the WAGO BACnet Library BACnet_02.lib

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

TU531, TU532 Terminal Unit

PHOENIX CONTACT - 05/2007

750 XTR Series TAKING IT TO THE EXTREME THE STANDARD FOR 750 XTR

WAGO-I/O-SYSTEM 750 IO-Link Master

AI531 Analog Input Module

Printview: End module for internal data bus extension - Item No.:

Manual. WAGO-I/O-SYSTEM 750 Programmable Fieldbus Controller ETHERNET /100 Mbit/s; digital and analog signals. Version 1.1.

Modular I/O-System ETHERNET TCP/IP

MINI MCR-SL-RPS-I-I. Repeater power supply, active. Data sheet. 1 Description

WAGO-I/O-SYSTEM 750 IO-Link Master

Operating instructions. Standstill monitor A / / 2011

Redundancy unit CP-A RU

TF501, TF521 Terminal Bases

Modular I/O-System ETHERNET TCP/IP

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

Address. Supply 24 V 0 V Fieldbus connection RJ-45. Fieldbus connection RJ-45. Configuration and programming interface. Pack. System Data.

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

MINI MCR-SL-CVS NC

PHOENIX CONTACT - 01/2008

Transcription:

Fieldbus Independent 4 AI Pt100/ RTD 750-460, (/xxx-xxx) Manual Version 1.0.2

ii General Copyright 2006 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße 27 D-32423 Minden Phone: +49 (0) 571/8 87 0 Fax: +49 (0) 571/8 87 1 69 E-Mail: info@wago.com Web: http://www.wago.com Technical Support Phone: +49 (0) 571/8 87 5 55 Fax: +49 (0) 571/8 87 85 55 E-Mail: support@wago.com Every conceivable measure has been taken to ensure the correctness and completeness of this documentation. However, as errors can never be fully excluded, we would appreciate any information or ideas at any time. E-Mail: documentation@wago.com We wish to point out that the software and hardware terms as well as the trademarks of companies used and/or mentioned in the present manual are generally trademark or patent protected.

Content iii Content 1 Important Comments...4 1.1 Legal Principles...4 1.1.1 Copyright...4 1.1.2 Personnel Qualification...4 1.1.3 Intended Use...4 1.2 Symbols...5 1.3 Number Notation...5 1.4 Safety Notes...6 1.5 Scope...6 2...7 2.1 Analog Input Modules...7 2.1.1 750-460, (/xxx-xxx) [4 AI Pt100/ RTD]...7 2.1.1.1 View...7 2.1.1.2 Variations...7 2.1.1.3 Description...8 2.1.1.4 Display Elements...9 2.1.1.5 Schematic Diagram...9 2.1.1.6 Technical Data...10 2.1.1.7 Process Image...11 2.1.1.7.1 for Pt Resistance Sensors...11 2.1.1.7.2 for Ni Resistance Sensors...12

4 Important Comments Legal Principles 1 Important Comments 1.1 Legal Principles 1.1.1 Copyright To ensure fast installation and start-up of the units described in this manual, we strongly recommend that the following information and explanations are carefully read and abided by. This manual is copyrighted, together with all figures and illustrations contained therein. Any use of this manual which infringes the copyright provisions stipulated herein, is not permitted. Reproduction, translation and electronic and photo-technical archiving and amendments require the written consent of WAGO Kontakttechnik GmbH & Co. KG. Non-observance will entail the right of claims for damages. WAGO Kontakttechnik GmbH & Co. KG reserves the right to perform modifications allowed by technical progress. In case of grant of a patent or legal protection of utility patents all rights are reserved by WAGO Kontakttechnik GmbH & Co. KG. Products of other manufacturers are always named without referring to patent rights. The existence of such rights can therefore not be ruled out. 1.1.2 Personnel Qualification 1.1.3 Intended Use The use of the product detailed in this manual is exclusively geared to specialists having qualifications in PLC programming, electrical specialists or persons instructed by electrical specialists who are also familiar with the valid standards. WAGO Kontakttechnik GmbH & Co. KG declines all liability resulting from improper action and damage to WAGO products and third party products due to non-observance of the information contained in this manual. For each individual application, the components supplied are to work with a dedicated hardware and software configuration. Modifications are only permitted within the framework of the possibilities documented in the manuals. All other changes to the hardware and/or software and the nonconforming use of the components entail the exclusion of liability on part of WAGO Kontakttechnik GmbH & Co. KG. Please direct any requirements pertaining to a modified and/or new hardware or software configuration directly to WAGO Kontakttechnik GmbH & Co. KG.

Important Comments 5 Symbols 1.2 Symbols Danger Always abide by this information to protect persons from injury. Warning Always abide by this information to prevent damage to the device. Attention Marginal conditions must always be observed to ensure smooth operation. ESD (Electrostatic Discharge) Warning of damage to the components by electrostatic discharge. Observe the precautionary measure for handling components at risk. Note Routines or advice for efficient use of the device and software optimization. More information References on additional literature, manuals, data sheets and INTERNET pages 1.3 Number Notation Number Code Example Note Decimal 100 normal notation Hexadecimal 0x64 C notation Binary '100' '0110.0100' Within ', Nibble separated with dots

6 Important Comments Safety Notes 1.4 Safety Notes Warning Switch off the system prior to working on bus modules! In the event of deformed contacts, the module in question is to be replaced, as its functionality can no longer be ensured on a long-term basis. The components are not resistant against materials having seeping and insulating properties. Belonging to this group of materials is: e.g. aerosols, silicones, triglycerides (found in some hand creams). If it cannot be ruled out that these materials appear in the component environment, then additional measures are to be taken: - installation of the components into an appropriate enclosure - handling of the components only with clean tools and materials. Attention Cleaning of soiled contacts may only be done with ethyl alcohol and leather cloths. Thereby, the ESD information is to be regarded. Do not use any contact spray. The spray may impair the functioning of the contact area. The and its components are an open system. It must only be assembled in housings, cabinets or in electrical operation rooms. Access must only be given via a key or tool to authorized qualified personnel. The relevant valid and applicable standards and guidelines concerning the installation of switch boxes are to be observed. ESD (Electrostatic Discharge) The modules are equipped with electronic components that may be destroyed by electrostatic discharge. When handling the modules, ensure that the environment (persons, workplace and packing) is well grounded. Avoid touching conductive components, e.g. gold contacts. 1.5 Scope This manual describes the Analog Input Module 750-460, (/xxx-xxx) 4 AI Pt100/ RTD of the modular. Handling, assembly and start-up are described in the manual of the Fieldbus Coupler. Therefore this documentation is valid only in the connection with the appropriate manual.

750-460, (/xxx-xxx) [4 AI Pt100/ RTD] 7 View 2 2.1 Analog Input Modules 2.1.1 750-460, (/xxx-xxx) [4 AI Pt100/ RTD] 2.1.1.1 View 4-Channel Analog Input Module for RTDs 2- conductor connection 13 14 Error AI 1 Error AI 3 +R 1 A B C D +R1 +R2 -R1 -R2 Error AI 2 Error AI 4 Data contacts +R 2 -R 1 +R3 +R4 -R 2 +R 3 -R3 -R4 +R 4 -R 3 -R 4 750-460 Fig. 2.1.1-1: 4-: 4-Channel Analog Input Module 750-460 g046000e 2.1.1.2 Variations Item-No. Designation Description Pt resistance sensors 750-460 4 AI PT100/RTD 4- Channel Analog Input Module, Pt 100 Measuring range: -200 C... +850 C 750-460/000-003 4 AI PT1000/RTD 4- Channel Analog Input Module, Pt 1000 Measuring range: -200 C... +850 C Ni resistance sensors 750-460/000-005 4 AI Ni 1000/RTD 4- Channel Analog Input Module, Ni 1000 Measuring range: -60 C... +250 C

8 750-460, (/xxx-xxx) [4 AI Pt100/ RTD] Description 2.1.1.3 Description The 750-460 analog input module allows Pt or Ni Resistive Temperature Devices, RTDs, to be measured in the field. It can also be used to measure resistances in the field. Depending on the operating mode, the resistance value is converted to a temperature or directly sent out by the module. A microprocessor within the module is used for converting and linearizing the measured resistance value into a numeric value proportional to the temperature of the selected resistance sensor. The analog input module is a 2-conductor device and has 4 input channels. Four devices may be directly connected to the module. The shield (screen) is directly connected to the DIN rail. A capacitive connection is made automatically when snapped onto the DIN rail. A broken wire, short-circuit or overrange are indicated by a red error LED per channel. An optocoupler is used for electrical isolation between the bus and the field side. Any configuration of the input modules is possible when designing the fieldbus node. Grouping of module types is not necessary. Attention This module has no power contacts. For field supply to downstream I/O modules, a supply module will be needed. The analog input module 750-460 and its variations can be used with all couplers/controllers of the (except for the economy types 750-320, -323, -324 and -327).

750-460, (/xxx-xxx) [4 AI Pt100/ RTD] 9 Display Elements 2.1.1.4 Display Elements A B A B 13 14 C D C D Fig. 2.1.1-2: Display Elements g045302x LED Channel State Function A red B red C red D red 1 2 3 4 off on off on off on off on Normal operation Overrange/underflow of the admissible measuring range, broken wire Normal operation Overrange/underflow of the admissible measuring range, broken wire Normal operation Overrange/underflow of the admissible measuring range, broken wire Normal operation Overrange/underflow of the admissible measuring range, broken wire 2.1.1.5 Schematic Diagram +R 1 1 5 +R 2 +R A D Logic -R 1 2 6 -R 2 270pF Function Error +R 3 3 7 +R 4 -R 10nF 4 -R 3 -R 4 8 Shield 750-460 Fig. 2.1.1-3: 4-Channel Analog Input Module 750-460 g046001e

10 750-460, (/xxx-xxx) [4 AI Pt100/ RTD] Technical Data 2.1.1.6 Technical Data Module Specific Data Number of inputs 4 Voltage supply Current consumption max. (internal) Sensor types Sensor connection Temperature range via system voltage DC /DC 65 ma Pt 100 (factory preset), optionally orderable variants for Pt 1000, Ni 1000 2-wire Resolution 0,1 C Conversion time Measuring error 25 C Temperature coefficient Isolation Measured current typ. Bit width -200 C... +850 C (Pt) -60 C... +250 C (Ni) 250 ms <± 0.2 % of full scale value <± 0.01 % /K of full scale value 400 V (System/Supply) 0.5 ma 4 x 16 bits data 4 x 8 bits control/status (option) Dimensions (mm) W x H x L 12 x 64* x 100 * from upper edge of 35 DIN rail Weight ca. 55 g Standards and Regulations (cf. Chapter 2.2 of the Coupler/Controller Manual) EMC-Immunity to interference (CE) acc. to EN 50082-2 (96) EMC-Emission of interference (CE) acc. to EN 50081-1 (93) Approvals (cf. Chapter 2.2 of the Coupler/Controller Manual) CUL US (UL508) Conformity Marking More Information Detailed references to the approvals are listed in the document "Overview Approvals ", which you can find on the CD ROM ELECTRONICC Tools and Docs (Item-No.: 0888-0412) or in the internet under: www.wago.com! Documentation!! System Description

750-460, (/xxx-xxx) [4 AI Pt100/ RTD] 11 Process Image 2.1.1.7 Process Image Some fieldbus systems can process input channel status information by means of a status byte. This status byte can be displayed via the starting tool WAGO-I/O-CHECK 2. However, processing via the coupler / controller is optional, which means that accessing or parsing the status information depends on the fieldbus system. Attention The representation of the process data of some I/O modules or their variations in the process image depends on the fieldbus coupler/-controller used. Please take this information as well as the particular design of the respective control/status bytes from the section "Fieldbus Specific Design of the Process Data" included in the description concerning the process image of the corresponding coupler/controller. 2.1.1.7.1 for Pt Resistance Sensors Pt resistance sensors (Measuring range: -200 C... +850 C) 750-460 Evaluation of Pt 100 750-460/000-003 Evaluation of Pt 1000 To evaluate the platinum resistance sensors, the measured values of the resistance are converted and sent as temperature values. All temperature values are represented in a standard numeric format. The possible numerical range matches the defined temperature range of the Pt sensors from -200 C to +850 C. In the Pt 100 or Pt 1000 setting, the temperature values of the sensors are represented with a resolution of 1 digit per 0.1 C within a word (16 bits). Thus, 0 C corresponds to the numeric value 0x0000 and 100 C to 0x03E8 (dec. 1000). Temperature values below 0 C are represented in two s complement binary form. The analog input module 750-460 transmits 16-bit measured values per channel as well as 8 optional status bits to the coupler/controller. However, accessing the status byte depends on the fieldbus system being used.

12 750-460, (/xxx-xxx) [4 AI Pt100/ RTD] Process Image 750-460 (Pt 100) and 750-460/000-003 (Pt 1000) Temperature Numerical value 1) byte Error Status- LED C binary hex. dec. hex. AI 1, 2 <-200.00 '1000.0000.0000.0001' 0x8001-32767 0x41 on -200.00 '1111.1000.0011.0000' 0xF830-2000 0x00 off -100.00 '1111.1100.0001.1000' 0xFC18-1000 0x00 off 0.00 '0000.0000.0000.0000' 0x0000 0 0x00 off 100.00 '0000.0011.1110.1000' 0x03E8 1000 0x00 off 200.00 '0000.0111.1101.0000' 0x07D0 2000 0x00 off 500.00 '0001.0011.1000.1000' 0x1388 5000 0x00 off 750.00 '0001.1101.0100.1100' 0x1D4C 7500 0x00 off 800.00 '0001.1111.0100.0000' 0x1F40 8000 0x00 off 850.00 '0010.0001.0011.0100' 0x2134 8500 0x00 off >850.00 '0010.0001.0011.0100' 0x2134 8500 0x42 on Broken wire against R L '0010.0001.0011.0100' 0x2134 8500 0x42 on 1) Temperature values below 0 C are represented in two s complement binary form. The measured value can exceed the range from 2000 to 8500 until the limitation applies. 2.1.1.7.2 for Ni Resistance Sensors Ni resistance sensors (Measuring range: -60 C... +250 C) 750-460/000-005 Evaluation of Ni 1000 To evaluate the nickel resistance sensors, the measured values of the resistance are converted and sent as temperature values. All temperature values are represented in a standard numeric format. The possible numerical range matches the defined temperature range of the Ni sensors from -60 C to +250 C. In the Ni 1000 setting, the temperature values of the sensors are represented with a resolution of 1 digit per 0.1 C within a word (16 bits). Thus, 0 C corresponds to the numeric value 0x0000 and 100 C to 0x03E8 (dec. 1000). Temperature values below 0 C are represented in two s complement binary form. The analog input module transmits 16-bit measured values per channel as well as 8 optional status bits to the coupler/controller.

750-460, (/xxx-xxx) [4 AI Pt100/ RTD] 13 Process Image 750-460/000-005 (Ni 1000) Temperature Numerical value 1) byte Error Status- LED C binary hex. dec. hex. AI 1, 2 <-60.0 '1000.0000.0000.0001' 0x8001-32767 0x41 on -60.0 '1111.1101.1010.1000' 0xFDA8-600 0x00 off -50.0 '1111.1110.0000.1100' 0xFE0C -500 0x00 off 0.0 '0000.0000.0000.0000' 0x0000 0 0x00 off 50.0 '0000.0001.1111.0100' 0x01F4 500 0x00 off 100.0 '0000.0011.1110.1000' 0x03E8 1000 0x00 off 150.0 '0000.0101.1101.1100' 0x05DC 1500 0x00 off 200.0 '0000.0111.1101.0000' 0x07D0 2000 0x00 off 250.0 '0000.1001.1100.0100' 0x09C4 2500 0x00 off >250.0 '0010.0001.0011.0100' 0x2134 8500 0x42 on Broken wire against R L '0010.0001.0011.0100' 0x2134 8500 0x42 on 1) Temperature values below 0 C are represented in two s complement binary form. The measured value can exceed the range from 600 to 2500 until the limitation applies.

WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 D-32385 Minden Hansastraße 27 D-32423 Minden Phone: 05 71/8 87 0 Fax: 05 71/8 87 1 69 E-Mail: info@wago.com Internet: http://www.wago.com