EDX-10 Series. Compact Recording System

Similar documents
EDX-10 Series. Compact Recording System

PCD-400A/430A. Sensor Interface. Carrier Wave Type Compact and Moderate Prices. Data Recorders/Analyzers MEASURING INSTRUMENTS

EDX-10 Series Compact Recording System

Specifications. Models. Models EDX-200A-2H EDX-200A-2H-0 EDX-200A-2H-1 EDX-200A-4H EDX-200A-4H-0 EDX-200A-4H-1 EDX-200A-4T

DC-204R DC-204Ra SMART DYNAMIC STRAIN RECORDER. 200kHz 2GB UPS. Strain DC voltage Temperature. TML Pam E-442B. capacity. High speed sampling

BX8 8-Channel Digital Amplifier

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

IPM650 Intelligent Panel-Mount Display

Specification for temperature sensor calibration setup

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

7-4-2 CP1W-MAD11/CPM1A-MAD11 Analog I/O Units

Expanding the Basic GL7000 Configuration

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

More Precision. optoncdt // Laser displacement sensors (triangulation)

System StrainSmart Data Acquisition System. Micro-Measurements FEATURES DESCRIPTION MODEL 5100B SCANNER SPECIFICATIONS

SCP for Plastics Processing

Isolated Process Current Output 3B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

DBK48. Multipurpose Isolated Signal-Conditioning Module. Description. Supports up to Sixteen 8B Modules

DINALOG A 144 x 36 A1400 Light-Strip Indicator

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

DM3100 Solutions. Application-specific Portable Data Capture Systems built on the DM3100 Data Platform. PC-based Data Logger. Digital Oscilloscope

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

MODEL 9250 Preliminary data sheet

6220 Ethernet-Based Voltage Measurement Module

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

BSL Hardware Guide for MP35 and MP30-1 -

Strain Gauge Measurement by Applying Displacement using Strain Indicator

DI-788 Data Acquistion System

AWG2300. USB Multifunction Arbitrary Waveform Generator SCICORE INSTRUMENTS, INC.

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

TML Pam E-3011C TML. Data Logger TDS-540. High Performance and Easy Handling

LAUREL ELECTRONICS, INC.

Multifunction Calibrator

USER MANUAL. AUTOLOG 3000 and PICAS Touch. Version: 2.21 Date: Page 1 of 145

Signal Conditioning Modules and Terminal Boards

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

GSV-1A4 M12/2 M12/2. Highlights

PRODIS. PD-ADC Digital Process Meter for analog Sensors. Digital Process Meters. Datasheet

EM2020 Selectable AC transducer A (UK)

6A27 6A40 6A68 6A154 6A175

6224 Ethernet-Based Strain Measurement Module

AO-1604LX-USB. Features. High-Resolution Analog Output Unit for USB AO-1604LX-USB 1. Ver.1.01

MANUAL PCE-123

More Precision. optoncdt // Laser displacement sensors (triangulation)

NX-series Temperature Control Unit NX-TC

More Precision. optoncdt // Laser displacement sensors (triangulation)

Strain Gage Measuring Amplifier GSV-3

Model SC500. Programmable Single-Channel Transducer Indicator/Conditioner DESCRIPTION FEATURES

P-25 3-pin plug to 20-hole receptacle. P-28 3 round crimp-style terminals. CM-39 2-pin conversion plug. P-70 4-pin plug to 2 twisted pair conductors,

Signal Doublers. VariTrans A 20300

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

ADAM-6200 Series. Feature. Transition and Vision on Remote DAQ Device 19-13

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

User Manual INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

Advanced NI-DAQmx Programming Techniques with LabVIEW

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Handy Calibrators

SCM5B. SLX200 Data Acquisition System. isolynx. Data Acquisition Systems. Visit our website Features

More Precision. optoncdt // Laser displacement sensors (triangulation)

More Precision. optoncdt // Laser displacement sensors (triangulation)

More Precision. optoncdt // Laser displacement sensors (triangulation)

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Specifications USB-1616HS

More Precision. optoncdt // Laser displacement sensors (triangulation)

E101 - Strain Gauge Transducer Display Module. Contents

Process displays For current and voltage

ECL150/ECL150e. Eddy-Current Displacement Sensor INSTRUCTION MANUAL. Measurement Systems from LION PRECISION

StrainSmart Data Acquisition System

Digital Indicator Solutions

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

User Manual CTP64-Rotate

Cube67 - Modular I/O station

AIO LN-USB. Features. N Series for USB Multifunction DAQ Unit (8ch AI, 2ch AO, 16ch DIO) AIO LN-USB 1. Ver.1.01

Temperature measurement board, optically isolated, 16/8/4 channels for thermocouples, Pt100, RTD, 18-bit

More Precision. optoncdt // Laser displacement sensors (triangulation)

WTX110. Legal-for-trade industrial weighing terminal. Special features. Data sheet

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

VIBBOX. 32, 48, or 64-Channel Sound & Vibration Solution Expansion to 256 Channels. Key Feature of Each VIBbox: Table 1. Key Features of VIBbox Models

DIGITAL PRESSURE SENSOR SCANNER CUM DATALOGGER

GE Fanuc IC694ALG221. Rx3i PacSystem

Time Counters mini "h", DC Version

Strain Gage Measuring Amplifier GSV-1

SINGLE-CHANNEL PROCESS CONTROLLERS & TEMP. DISPLAYS D3820/D3830 Series

LC0 DVP

Expandable Modular Data Acquisition System inet-400 Series

LAUREL ELECTRONICS, INC.

Voice Alarm System VX-3000 Series

D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

8 or 16 Channel Universal Input Touch Screen Data Logger

8 or 16 Channel Universal Input Touch Screen Data Logger

DIO-0808RN-USB. N Series for USB Isolated Digital I/O Unit(8ch Relay Output, 8ch DI) DIO-0808RN-USB 1. Ver.1.02

High-Temp PRT Module 2561

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use.

Transcription:

3-51 EDX-10 Series Compact Recording System Compact & lightweight, with a simple configuration, all channels synchronous 20 khz high-speed sampling (For 4 channels) Control Unit EDX-10B A unit controls measuring units and performs communication with PC via USB interface. The EDX-10 series compact recording system is measuring instruments that measure simply by being connected to a PC using the USB interface. The EDX-11A and EDX-14A measure strain-gage transducers, pressure, displacement, etc. The EDX-12A measures voltage, the EDX-15A measures force, pressure, displacement, and voltage, and the EDX-13A measures temperature with a thermocouple. A single unit for 4-channel measurement, 4 units for 16 channels, thus it is suitable for small-scale measurement. Up to 4 measuring units are powered by USB interface, no separated power supply is required. With stacked connection, no synchronization cable is required, therefore wiring-saving. Max. sampling frequency 20 k Hz for 4 channels of a single measuring unit in sync. Compact & lightweight Simple connection using USB interface The standard accessory, Dynamic Data Acquisition Software DCS-100A, makes it easier data monitoring or acquisition. Data is recorded as KS2, which is Kyowa standard file format. The optional Data Analysis Software reads the file. Sensors are easily connected with one-touch input cables or input adapters. Interfaces USB2.0 compliant Connector configuration: USB standard B receptacle Installed Measuring Units Max. 4 (16 channels) Sampling Frequencies 1 Hz to 20 k Hz (1 to 4 channels) 1 Hz to 10 k Hz (1 to 8 channels) 1 Hz to 5 k Hz (1 to 16 channels) 5 VDC by USB bus power or a AC adapter Current Consumption 140 ma or less (5 VDC) Approx. 170 g.0 W H.0 D mm Control Software DCS-100A Optional USB cable N-38 (1 m) Ground wire P-72 (5 m) DVD (Dynamic data acquisition software DCS-100A) AC adapter UN310-0515 (For U.S.A.: UN312-0520) Notes: 1. When power supply from a USB port, please connect the EDX-10B to the PC directly. No USB hub is required. 2. The AC adapter operates any 4 measuring units. 3. The combination of measuring units for power supply by USB port are as follows. USB ports USB 3.0 USB 2.0 EDX-11A units 0 1 2 0 1 Connection units Max. 4 Max. 2 Max. 2 Max. 1 3-51

Strain Measuring Unit EDX-14A A low power unit for measuring strain based on the DC bridge excitation. Low-power Strain/Voltage Measuring Unit EDX-15A A unit for measuring both strain and voltage. Measuring Targets Strain-gage transducers, strain gages* Measuring Range 10 k, 50 k 10-6 strain (2 steps) Applicable Bridge Resistance 120 Ω to 1 kω Bridge Excitation 1 VDC Gage Factor 2.00 fixed Current Consumption 140 ma or less (120 Ω load with all channels connected, at power supply 5 VDC).0 W H.0 D mm *Bridge boxes or input adapters are required for strain measurement. Optional Strain input cable U-124 (30 cm) Measuring Targets Strain-gage transducers, strain gages* Voltage Measuring Range 10 k, 50 k 10-6 strain (2 steps) 10, 50 V Applicable Bridge Resistance 120 Ω to 1 kω Bridge Excitation 1 VDC Gage Factor 2.00 fixed Current Consumption 150 ma or less (120 Ω load with all channels connected, at power supply 5 VDC).0 W H.0 D mm *Bridge boxes or input adapters are required for strain measurement. Optional input adapter UI-52A Bridge adapter for quarter bridge system UI-53A-120/350 Bridge adapter for quarter bridge system UI-54A-120/350 input adapter UI-55A Strain input cable U-124 (30 cm) Conversion adapter FV-1A x4 input adapter UI-52A Bridge adapter for quarter bridge system UI-53A-120/350 Bridge adapter for quarter bridge system UI-54A-120/350 input adapter UI-55A 3-52 3-52

3-53 3-53 Voltage Measuring Unit EDX-12A A unit for measuring voltage Thermocouple Measuring Unit EDX-13A A unit for measuring temperature by using thermocouples K T J N 200.0 to 1370.0 C 200.0 to 400.0 C 200.0 to 1200.0 C 200.0 to 1300.0 C 100.0 to 1370.0 C 100.0 to 400.0 C 100.0 to 1200.0 C 100.0 to 1300.0 C Optional BNC input cable U-125 (30 cm) input adapter UI-52A Terminal box 1piece, screwdriver 1piece Types (Resolution: 0.1 C ) Accuracy of internal reference contact compensator Note: The measurement accuracy does not include the accuracy of the internal reference contact compensator and thermocouples. Strain Measuring Unit EDX-11A A unit for measuring strain based on the DC bridge excitation. * When using strain gages, an optional bridge box or input adapter is required. Measuring Targets Voltage Channels 4 (Single end) Measuring Range 10 V, 50 V (2 steps) Current Consumption 110 ma or less (5 VDC).0 W H.0 D mm Measuring Targets Thermocouples Measuring Targets K, T, J, N (Resistance of thermocouple: 1 kω or less) (See the table below for details about the temperature measuring range, etc.) Check Functions Burnout check Sampling System Scanning Inside Sampling Frequencies Approx. 0.5 Hz, approx. 2.0 Hz Screw type terminal box Current Consumption 120 ma or less (5 VDC) Approx. 130 g.0 W H.0 D mm Optional ±1.0 C Input terminal temperature at equilibrium Ambient temperature: 25±10 C Mount the EDX-13A on the bottom when using it with measuring units other than the EDX-13A. ±2.0 C Input terminal temperature in equilibrium For temperatures other than those in the ambient temperature and operating temperature described above Measuring Targets Strain-gage transducers Strain gage Measuring Range 10 k, 50 k 10-6 strain (2 steps) Applicable Bridge Resistance 120 Ω to 1 kω Bridge Excitation 2 VDC Gage Factor 2.00 fixed Current Consumption 1 ma or less (120 Ω load with all channels connected, at power supply 5 VDC).0 W H.0 D mm Strain input cable U-124 (30 cm) input adapter UI-52A, UI-55A Bridge adapter for quarter bridge system UI-53A-120/350 Bridge adapter for quarter bridge system UI-54A-120/350

DCS-100A software for EDX-10B section For details of DCS-100A, see page 4-3. Controllable Units Interfaces Data Storage Channel Conditions Max. 4 (Max. 16 channels) USB Measured data is saved in the PC as KS2 file. Measurement ON/OFF, mode, range,, balance, calibration coefficient, offset, unit, CH name, measuring range, rated capacity, rated output, decimal point, chk.val.(up), chk.val. (Down), (Selection of any display item is possible.) Sampling Frequencies 1 Hz to 20 khz (1-2-5 series) (Depends on the measuring channels) Measuring Modes Manual, manual (Data points preset), interval, and analog trigger Manual Measurement Measurement is made from a press of the REC button to a press of the STOP button or to completion of recording to the data points preset. Interval Measurement Measurement is made automatically at preset intervals from the preset starting time. Analog Trigger Measurement Start and/or stop recording based on the specified trigger conditions. End Trigger Settable Delay Both start and stop, max. 262144 data items/channel *Delay differs with the number of measurement channels. Trigger Channels Any 1 channel Trigger Level Sets in physical quantity. Trigger Slope Up, down Static Measurement Every time the DCS-100A starts recording data, the DCS-100A additionally saves the movingaveraged measured data in a single CSV format file in manual and interval modes. Repetition Acquisition In long-term data acquisition, a specified amount of data (or time) is saved in KS2 file. *Workable in manual mode (Data points preset). Environment Settings Hardware Configuration Setting of device name and measuring unit Configuration of device names connected to EDX-10B. Reading of hardware configuration from EDX-10B. 3-54 3-54

3-55 EDX-10B EDX-11A EDX-12A EDX-14A 21.6 21.6 3.5 21.6 3.5 EDX-13A EDX-15A 21.6 3.5 21.6 3.5 21.6 3.5 3-55 EDX-10 Series Recommended products for combination Bridge box DBV-120A-4E/ET DBV-350A-4E/ET 3-123 Data Analysis Software DAS-200A 4-9

Simplified configuration of the EDX-10 series 3-56 Dynamic Data Acquisition Software DCS-100A series Power supply 100 to 240 VAC Optional adapter UN310-0515 Ground wire (Provided) USB EDX-10B Control Unit EDX-10B + Data Analysis Software DAS-200A Strain Measuring Unit EDX-11A/14A/15A + Voltage Measuring Unit EDX-12A/15A + USB cable N-38 (1 m) (Provided) Thermocouple Measuring Unit EDX-13A (With terminal) EDX-11A/14A/15A Strain input cable U-124 0.3 m Bridge adapter for quarter bridge EDX-12A UI-53A-120 120 UI-53A-350 350 UI-54A-120 120 UI-54A-350 350 Input cable U-126 0.5 m Note: 2 connectors to EDX. Select 2 strain or voltage units. Input cable U-126 0.5 m Note: 2 connectors to EDX. Select 2 strain or voltage units. BNC input cable EDX-13A Bridge box for quarter bridge system DBS-120B-8 DBS-350B-8 bridge box DBV-120A-8, DBV-350A-8 bridge box DBV-120A-4, DBV-350A-4 *1 Input adapter input adapter input adapter Voltage input box VI-8A UI-51A UI-52A UI-55A Optional Strain-gage transducers (Connector type) Load cell, pressure/ acceleration/ torque transducers, etc. Strain gages Strain-gage transducers (Cable bared at tip) Voltage Voltage-output sensors U-125 0.3 Input adapter input adapter UI-51A UI-52A Thermocouples *1. N-46 is attached to DBV-120A-4E and DBV-350A-4E. 3-56