IMP-2MC ELECTRODE IMPEDANCE TESTER MULTICHANNEL

Similar documents
BUTT SET MODEL TT-200

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

2 in 1 LAN Tester and Multimeter Model:

Portable Conductivity Meter M1410. User Manual 1.002

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Mini Digital Multimeter

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE PTC-20 PELTIER TEMPERATURE CONTROL SYSTEM

BIPOLAR OPERATIONAL POWER SUPPLY

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TC-20 TEMPERATURE CONTROL SYSTEM

User's Guide. MiniTec TM Series Model MN25 MultiMeter

BOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY I INTRODUCTION

User's Guide. Digital Multimeter. Model MN42

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

PRe3. Two Channel Analog Pre-Amplifier

POCKET MULTIMETER Model No: MM18

User's Guide. Extech AM A AC Analog Clamp Meter

HS-27-Mini. Headstage preamplifier providing 27 channels of unity gain amplification.

STARTER 3000 Bench ph Meter Instruction Manual

Mini Digital Multimeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

BENCHMARK MEDIA SYSTEMS, INC.

User Guide. Moisture Meter. Model MO250

OPERATION MANUAL MODEL TT-LP

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

Electronic Loads. Installation & Operation Manual EL101/300 EL1000

DFI 9000 PORTABLE DIGITAL INDICATOR USER S GUIDE

MC-1 OPERATION MANUAL MINI CAMERA JW FISHERS MFG INC 1953 COUNTY ST. E. TAUNTON, MA USA

ATE QUICK START GUIDE. KEPCO An ISO 9001 Company. VOLTAGE/CURRENT STABILIZED POWER SUPPLY I INTRODUCTION

R Band Parametric Equalizer (6 Center Frequencies)

S300i. Two Channel Integrated Audio Amplifier

ETHOS Auto Ranging Digital Multimeter

Instruction Manual. CCP Supply Type 12AL SOUND & VIBRATION. Skovlytoften 33, 2840 Holte, Denmark

Model R5010. TRMS Digital Multimeter. Instruction Manual

Please use the Q & A utility to ask us any questions concerning the material being presented.

intan intan RHD Channel Amplifier Board RHD Channel Amplifier Board Description Features Applications TECHNOLOGIES, LLC

HS-27 Manual 5/2/2013. Neuralynx, Inc. 105 Commercial Drive, Bozeman, MT Phone Fax

1073N. Channel Amplifier. User Manual Issue 1.3

Mini Digital Multimeter

Large Display Salinity & Conductivity Pens &

HI 9828 Multiparameter Water Quality Meter...

User Guide True RMS Multimeter Extech EX205T

SMART SENSORS. Water quality sensors with built in digital & analog microtransmitters

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE HVA-100 HIGH VOLTAGE AMPLIFIER MODULE FOR EPMS SYSTEMS

Quicksilver 606 TR-606 CPU Upgrade

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter

User Guide. ExStik FL700. Fluoride Meter

Platinum RTD Thermometer MODEL NO

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

RPS-401A, RPS-426A Self-Contained Ultrasonic Sensor

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no.

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

Dissolved Oxygen Meter Kit DOK. Instruction Manual

MODEL 801R REMOTE CONTROL MICROPHONE PREAMPLIFIER

Research Grade Meters

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

HM21 Test Unit. Jandel Engineering Limited PORTABLE COMBINED CONSTANT CURRENT SOURCE AND VOLTMETER. Jandel Engineering Limited

Electrostatic Fieldmeter Model 775

40,000-Count Dual-Display Handheld LCR Meters Models 878B, 879B, and 880

Digital Multimeter User's Manual

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

STATIC METERS Models 211 & 212. SURVEYORSTAT Models 211XL & 212XL

CHAPTER 5. Voltage Regulator

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

Operating Instructions

Standard reference resistor Model CER6000

PLD Series +5V Laser Diode Drivers

Digital Clamp-on Meter Instruction Manual

Wilcoxon Research P702B/P702BF-1 operating guide Power unit/amplifier for piezoelectric transducers with internal amplifiers

Isolated Current Output 5B39 FEATURES APPLICATIONS PRODUCT OVERVIEW

Various regulation agencies require us to bring the following information to your attention. Please read carefully.

Mini Digital Multimeter Model MN15. User's Guide

Operating Instructions

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Model CR103J. DC Current and Voltage Calibrator/Standard ±0.01µA to ± mA ±0.1µV to ± V. Operating Manual

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Model DT-315P DIGITAL STROBOSCOPE INSTRUCTION MANUAL

HI ma Simulator

1523/1524 Reference Thermometers

Owner's Manual AC & BATTERY POWERED FET

Drexel University Electrical and Computer Engineering Department ECE 200 Intelligent Systems Spring Lab 1. Pencilbox Logic Designer

Operating Instructions ACM-100 Aircraft Cable Tension Meter

ph, ORP, and TDS ORP Continuous Monitor OPERATING INSTRUCTIONS 8. Warranty 9. Return of Goods

USER GUIDE. Salinity Meter Pen Style Water Quality Meter. Model EC170

MIDI CPU Hardware Rev K. User Manual

PRODUCT INSTRUCTIONS MODEL SR-2 SOIL RESISTIVITY METER

MODEL USB-DA12-8E Eight Channel Digital to Analog Converter USER MANUAL

Plasma Panel Replacement Guide DU-42PX12X

Network Upgrade for the LINK DAC III

User s Manual. Digital Baby Scales. Hopkins Featherweight Baby Scale # Hopkins Featherweight XL Baby Scale # # #688340

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Transcription:

MicroProbes for Life Science IMP-2MC ELECTRODE IMPEDANCE TESTER MULTICHANNEL User Instructions Version: January, 2016 18247-D Flower Hill Way Gaithersburg, MD 20879 Phone: +1 301 330-9788 Fax: +1 301 330-9667 w w w.microprobes.com support@microprobes.com

Table Of Contents Introduction 3 Specifications 4 Multichannel Connector Mapping 4 Control Layout 5 Front Panel 5 Back Panel 6 Operating Instructions Powering the Unit On and Off 6 Connecting Electrodes for Measurement 7 Measuring Electrode Impedance 8 Calibration 10 Connecting an External Signal 11 Testing the Internal Battery 12 Terms and Conditions 13 Contact information 13 6 2

Introduction The IMP-2MC Multichannel Electrode Impedance Tester is an instrument designed to quickly and conveniently measure the 1 khz impedance of 16-channel electrode arrays, accurate within a range of 1 kω to 5 MΩ. While the IMP-2MC is only capable of measuring one channel at a time, it features a multichannel cable and selection switch allowing for simple and convenient array connection and channel selection, without requiring repeated changes to lead connections. The IMP-2MC displays impedances in real time by way of an easy-to-read analog meter, making it an effective tool for tracking changes to impedance over time. In addition, the IMP-2MC is capable of delivering an externally-derived current or voltage to the electrode using a simple toggle switch, providing an easy way to bubble test, break down oxide layers, and clean electrodes to achieve lower impedances. The IMP-2MC is a fully-portable lightweight battery-powered unit featuring a carry handle that doubles as a stand, allowing the device to be tilted to multiple viewing angles. While principally designed to characterize high-impedance metal microelectrode arrays, the IMP-2MC is a general purpose device whose simple operation allows it to be a valuable tool in many different electrochemistry and medical laboratories. For instance, the IMP-2MC is an excellent instrument for matching the lower impedance values of electrodes used in differential EMG recordings. When differential recordings are done with electrode pairs having approximately the same impedance value, the common mode rejection factor will substantially increase, thus increasing the signal-to-noise ratio. 3

Specifications Frequency Testing current 1 khz sine wave < 24 na (0-5 MΩ range) < 240 na (0-500 kω range) < 2.4 µa (0-50 kω range) < 24 µa (0-5 kω range) Testing Range Error Power Requirements Battery Life Size Weight 1 kω to 5 MΩ < 10% Two 9V Alkaline > 50 h 9" w x 3.5" h x 7.5" d 1.5 lbs. Multichannel Connector Mapping 13 1 25 14 Note: Pins 19 through 25 are unused. 4

Control Layout Front Panel 4 7 8 1 ON OFF BATTERY TEST RANGE CHANNEL 2 3 REFERENCE ELECTRODE TEST EXT SIGNAL CALIBRATE EXT ELECTRODE IMPEDANCE TESTER MODEL IMP-2MC 5 6 9 10 11 12 1. Power Switch 2. Reference Electrode Input 3. Working Electrode Input Electrode Being Tested 4. Battery Test Toggle Up: Normal Operation Down: Displays Internal Battery Voltage 5. Mode Toggle Up: Impedance Measurement Down: Applies External Signal to Working Electrode 6. External Signal Input 7. Range Switch 8. Calibration Button 9. Calibration Knob 10. Channel Selection Switch 11. Multichannel Connector 12. Measurement Display 5

Back Panel P O S N E G 11 12 13. Internal Battery Housing (2 x 9V) 14. Internal Battery Measurement Plugs Operating Instructions Powering the Unit On and Off The IMP-2MC Electrode Impedance Tester requires battery power to function, supplied by two internal 9V batteries accessible from the rear of the unit. The Power Switch on the front of the unit must be turned on to perform measurement. It is recommended that the power switch be turned off when the unit is not in use to preserve battery power. 6

Connecting Electrodes for Measurement Electrode Impedance is typically measured using an electrochemical cell, featuring the electrode to be tested (the working electrode), an electrolyte bath, and a reference or counter electrode. An electrochemical cell is often constructed by pouring an appropriate electrolyte solution into a clean glass beaker or dish, and then mounting the working electrode (or an array of working electrodes) and a counter electrode to the dish so that they are immersed within the saline a short distance apart. Typical electrolyte solutions include normal saline or 1X PBS. Large stainless steel or platinum sheets, pins, or wires are commonly used as counter electrodes. Before connecting the working electrode to the unit, make sure that the Mode Toggle is in the UP or TEST position, and not in the EXT position. The IMP-2MC is capable of connecting to individual electrodes as well as arrays of multiple electrodes. Individual electrodes can by connected to the unit by connecting the working electrode to the Working Electrode Input plug and the counter or reference electrode to the Reference Electrode Input plug on the front of the unit. Arrays of electrodes are connected by way of the Multichannel Connector. Each IMP-2MC unit is typically shipped with a Connector Cable that plugs into the multichannel connector and terminates in an array connector selected by the user at purchase. Users wishing to assemble their own custom cable may do so using the connector mapping provided on the specifications page of this manual. Note that you should always use an external counter electrode when measuring array electrodes, and not the counter electrode within the array itself. This will allow the array counter electrode itself to be evaluated using the tester. 7

To select the electrode to be measured within the array, rotate the Channel Selection Switch to the desired channel number. The IMP-2MC is only capable of measuring one channel at a time within the array. The user should refer to the array documentation to determine which array electrode corresponds to each channel on the connector. Note that when connecting a single electrode into the Working Electrode Input plug, the Channel Selection Switch is bypassed and the device will perform the measurement regardless of selected channel. To ensure accurate measurement, make sure all connections are clean, tight, and corrosion-free. Use high-quality, well-insulated wire leads, and try to keep wires as short and tangle-free as possible. Double check to make sure that ONLY the electrodes are immersed in the electrolyte, and that electrolyte solution is not touching any connectors or exposed wire ends. Abnormally high or low impedances are commonly caused by broken wires, corroded clips or contacts, or short circuits. Measuring Electrode Impedance Before turning the unit on, ensure that both the Battery Test and Mode Toggles are set to the UP position for normal operation. It is also recommended that unit battery level and calibration be checked before each measurement session. Instructions for testing battery level and calibration are provided later. To begin impedance measurement, ensure that all connections are properly configured and turn the power switch on the unit to the ON position. Measurement will begin as soon as the unit is turned on, for either the array electrode selected on the channel switch or a single electrode plugged into the working electrode input. Measured 1 khz electrode impedance is displayed in real time on the analog Measurement Display. The scale of the display is changed by rotating the Range Switch to the desired measurement range decade. The table below provides a quick reference for the scale of the measurement display at each setting of the range switch. 8

DISPLAY UNIT IMPEDANCE RANGE 5k 50k 500k 5 MEG 0 10 20 30 40 50 0Ω 1kΩ 2kΩ 3kΩ 4kΩ 5kΩ 0Ω 10kΩ 20kΩ 30kΩ 40kΩ 50kΩ 0Ω 100kΩ 200kΩ 300kΩ 400kΩ 500kΩ 0Ω 1MΩ 2MΩ 3MΩ 4MΩ 5MΩ If one is unsure of the approximate impedance of an electrode, always start measuring with the meter on the highest range and reduce the range until a useable reading is attained (somewhere between 10 and 50 on the meter). Failure to do this may subject the electrode to as much as 1.2V RMS. To achieve the greatest accuracy, the range switch should be rotated until the needle settles between 10 and 50 on the display, without pushing beyond 50. If the needle pushes above 50 when the range switch is set at the maximum setting of 5 MEG, it indicates that the 1 khz impedance of the electrode is above 5 MΩ and thus beyond the range of measurement of the device. As the device measures and displays impedance in real time, a degree of drift is expected over time, particularly in the moments after the electrode is first immersed and connected due to motion artifact. To achieve the most accurate measurement, hold the electrode motionless and wait for the needle to cease motion and settle. Note that the real time measurement capability of the device makes it useful for applications where the user may wish to track a continually-changing impedance, such as an electrode immersed in a treatment or coating solution. 9

Calibration To maintain the most accurate measurement capabilities of the device, it should be calibrated before each session. The Calibration Knob on the device front panel can be used to adjust the reading of the device to a known resistance. For convenience, the device is equipped with an internal calibration resistor, though users wishing for greater accuracy may employ their own external standard resistor instead. To calibrate using the internal resistor, the user should press and hold the Calibration Button while the unit is powered on. While holding down the calibration button, gently twist the calibration knob in either direction until the needle within the measurement display points directly upward to the 25 position on the dial. The letters CAL are also printed at this position as a reminder. Repeat this procedure at each setting of the range dial to ensure calibration across the entire measurement range. To calibrate using your own external resistor, there is no need to hold down the calibration button. Simply connect your resistor to the electrode and reference inputs on the front panel of the unit using wires and clips, and begin normal measurement. Be sure to set the range knob to the proper setting for your resistor. If properly calibrated, the measurement display dial will indicate the exact resistance of the connected standard resistor. If it does not, twist the calibration knob until the needle reads the proper resistance. 10

Connecting an External Signal For convenience, the device can be configured to connect to an external signal source and apply that signal to the electrode and reference inputs. For example, connecting a 9V battery to the external signal inputs and activating this mode will result in 9V being applied across the working electrode. This has many potential applications, including electrochemical cleaning and bubble testing. As each electrode or array has different requirements for cleaning or testing, it is recommended that you refer to the documentation of your electrode or array for further instructions, to avoid electrode damage or destruction. To begin, connect the external device or battery to the External Signal Input. Note that this input is color coded: The green terminal in the external signal input connects to the green reference electrode input, while the red terminal in the external signal input connects to the red working electrode input. This is extremely important for applications where polarity is crucial, such as cleaning or bubbling, where applying the incorrect polarity to the electrode could result in electrode damage. To apply the external signal to either the working electrode input or the array electrode selected on the channel switch, press and hold the Mode Toggle in the downward EXT position. While the toggle is held downward, the external signal will be applied to the selected electrode. Once the toggle is released, the device immediately disconnects the external signal and returns to measurement mode. 11

Testing the Internal Battery To function properly, the IMP-2MC requires two 9V batteries with sufficient voltage to accurately drive the internal circuitry. Thus, to ensure accurate measurement, it is necessary to occasionally test the voltage of the internal batteries to identify when they are in need of replacement. For convenience, the unit features an internal voltammeter. Fresh internal batteries should last for an average of 75 hours of operation before replacement, though battery testing should be performed semi-regularly, particularly if the unit is accidentally left powered on for an extended time. To test the internal battery, power the unit on and flip the Internal Battery Test Toggle upwards to the BATTERY position. The measurement display should now indicate the voltage of the internal batteries, where the number 50 indicates 9V or a full battery. As the batteries are expended, the needle will drift downwards. Once the needle drops below the number 35 on the dial, the batteries should be replaced. Batteries can be accessed using the Internal Battery Housing on the rear of the device. For precise internal battery measurement, the unit is equipped with a set of Internal Battery Measurement Plugs on the rear of the unit, which offer direct access to the battery for the use of your own voltammeter. 12

Terms and Conditions Please inspect the package carefully upon arrival and report any damage to us within 7 days of receipt of the package. Unused items may be exchanged if items and packaging are undamaged and in good condition. Exchange must be made within 30 days of invoice date and with prior permission from our Customer Service Department. Please call 301-330-9788 or email support@microprobes.com to request a Return Material Authorization (RMA) number. We do not accepted returns after 90 days from invoice date. Custom design products are non-returnable. Contact Information M icroprobes for Life Science 18247-D Flower Hill Way Gaithersburg, MD 20879 Phone: +1 (301) - 330-9788 Fax: +1 (301) - 330-9667 support@microprobes.com www.microprobes.com Microprobes for Life Science Inc. 2015 All rights reserved 13