DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm

Similar documents
Control different load types with one device

Control different load types with one device

DTE x 10A Trailing Edge Dimmer Installation Manual. contents

DBC x 10A HF Ballast Controller Installation Manual

DBC1220GL. 12 x 20A HF Ballast Controller Installation Manual. contents

Instruction Manual. Contents

DMC810GL. contents. Leading Edge Dimmer/HF Ballast Controller Installation Manual

Dynalite Multipurpose Controllers

DLE x 10A Leading Edge Dimmer Installation Manual

Control different load types with one device

PLPC905GL-3-KNX / PLPC905GL-3-HD-KNX / PLPC905GL-4-KNX / PLPC905GL-4-HD-KNX LightMaster Dimmer Actuator

SAVE THESE INSTRUCTIONS

DLE405 4 x 5A Leading Edge Dimmer Installation Manual

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

DLE1220GL-S. 12 x 20A Leading Edge Dimmer Installation Manual. contents

Control different load types with one device

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)

Switched Relay Controller - Relay Panel with Breakers

Network Devices & Commissioning Tools

Lighting Control Panel 16 and 24 INSTALLATION INSTRUCTIONS

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

OPLC Installation Guide

Compact controller for single room solutions

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

The identified danger could cause physical and property damage.

Installing the ILC LightSync 4.3 or 7 Touch Screen Station. Rev. B

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

Installing and Configuring Rialto Analytic Appliances

BCM2 Series Branch Circuit Monitors Quick Setup Guide

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Sophisticated yet simple energy-efficient lighting control solutions

Elapsed Timer Control Panel

Universal Safety Photo Eye UL MONITORED DEVICE

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

QUICK START. Installation & Programming Guide

EX-RC1 Remote I/O Adapter

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

INSTALLATION INSTRUCTIONS

Vision OPLC V TR6/V350-J-TR6

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Switched Mode Power Supply Operating manual PAP800

Model DMX8DIM Installation and Operations Manual

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

MAXIMA+ Series Rotary Level Indicator

PanelView Plus/VersaView CE Terminals and Display Modules

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Digital Lighting Systems, Inc.

H704-42(H)(E), H704-42/1(H)(E)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

PRO-1250D CT MID DIN rail three phase four wire energy meter.

MAXIMA + Series ROTARY LEVEL CONTROL

Installation and User Guide

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Abstract. GLV User Manual 1

INSTALLATION INSTRUCTIONS

Vision OPLC. V T38 Installation Guide. General Description

Standard Strip Series

NSD/M1 Installation Instructions

Quick Start Installation Guide

hp uninterruptible power system r12000 xr models installation instructions

NCH-1000 (Multiple Breaker Types) Installation Instructions

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L MONITORED DEVICE

Quick Start Installation Guide

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

Ethernet Adapter Installation Instructions

Installation Instructions

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34

WALLET-FRIENDLY INTENSITY

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

PLC Racks IC697CHS782/783

HomeWorks Remote Power Feed-Through Panels

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

Installing Power Modules

AB-2D AB-2D SPEAKER A,B OR A+B SELECTOR INSTALLATION & OPERATION GUIDE

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

S66 Series Electronic Fan Speed Control

PowerLogic High Density Metering System 1-Meter Enclosure

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

G12/G12x USER S MANUAL

Instruction Bulletin. Fiber Optic Switch Packs. SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION CONTENTS OF THE BOX

Dim levels for each system output may be controlled by either of the following methods:

GCI-5K INSTALLATION AND OPERATOR S MANUAL

MC 11 EB-2 Power supply cabinet with external bus, AC version

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Vision OPLC. General Description. Standard Kit Contents. Installation Guide Vision120. This guide provides basic information for Unitronics Vision120.

This guide provides basic information for Unitronics controller model V T2.

ZC Series Zone Monitoring Controllers

Nokeval. FD100 series. User Manual

Model# CKM18 Model# CKM36 Model# CKM48 WARNING

Power Supply Installation

Transcription:

Area for main photograph Area for insert photo W: 46.1mm up to 79 mm H: 46.1mm X: 12.6mm absolute on page Y: 132.6mm abs on page This insert has a shadow DMC2 Installation Guide Version 1.0

Contents DMC2 1 1 Product Overview 5 1.1 DMC2 Enclosure 6 1.1.1 Dimensions 6 1.1.2 Enclosure diagram 7 1.2 DSM2-XX 8 1.2.1 Dimensions / Diagrams 8 1.3 DMD31X Module 9 1.3.1 Dimensions 9 1.3.2 DMD31X module output wiring 10 1.4 DMP310-GL 11 1.4.1 Dimensions / Diagrams 11 1.5 DMR310 / DMR316 12 1.5.1 Dimensions / Diagrams 12 2 Installation 13 2.1 Installation requirements 13 2.2 Cabling 15 2.3 Mounting the DMC2 16 2.4 Inserting and connecting modules 17 2.4.1 DCM-DyNet 19 2.4.2 DSM2-XX 20 2.4.3 Control module installation 22 2.4.4 Wiring loom 24 3 Post-installation testing 25 3.1 Service LEDs and switch 25 3.2 Manual override keypad 26

About this Guide Overview Disclaimer Copyright This guide is designed to assist in the installation of the DMC2 Modular Controller. A working knowledge of Dynalite commissioning processes is required to effectively use this document. For more information on the commissioning process, consult the DMC2 Commissioning Guide. These instructions have been prepared by Philips Dynalite and provide information on Philips Dynalite products for use by registered owners. Some information may become superseded through changes to the law and as a result of evolving technology and industry practices. Any reference to non- Philips Dynalite products or web links does not constitute an endorsement of those products or services. 2015 Dynalite, DyNet and associated logos are the registered trademarks of Koninklijke Philips Electronics N.V. All other trademarks and logos are the property of their respective owners. DMC2 4

1 Product Overview The Philips Dynalite DMC2 is a versatile modular controller that consists of a power supply module, communication module, and up to two interchangeable control modules. The power and communication modules are listed below: DSM2-XX Single-phase or three-phase supply module that supplies power to the communications and control modules. DCM-DyNet Communications module that supports DyNet, DMX Rx, dry contact inputs and UL924 input. A variety of control modules provide simultaneous control of multiple load types and capacities: DMD Driver control module for 1-10V, DSI and DALI drivers. DMP Phase control dimmer module for Leading or Trailing Edge output, suitable for use with most types of dimmable electronic drivers. DMR Relay control module for most types of switched loads. The DMC2 can be surface or recess-mounted, and features a number of cabling knockouts to accommodate a variety of communication, supply and load configurations. DMC2 5 Product Overview

1.1 DMC2 Enclosure September 24, 2015 The DMC2 enclosure is a galvanized steel case with powder coated front covers. It includes mounting bays for power supply module, communication module and two output modules. 1.1.1 Dimensions DMC2 6 Product Overview

September 24, 2015 1.1.2 Enclosure diagram DMC2 7 Product Overview

1.2 DSM2-XX September 24, 2015 The DSM2-XX fits into the top module bay of the enclosure, and supplies power to the communication and control modules. 1.2.1 Dimensions / Diagrams DMC2 8 Product Overview

1.3 DMD31X Module September 24, 2015 The DMD31X module is a three-channel signal controller. Each channel is individually configurable to DALI Broadcast, 1-10V or DSI. 1.3.1 Dimensions DMC2 9 Product Overview

1.3.2 DMD31X module output wiring September 24, 2015 The control signal must be terminated into the top six terminals on the module. The power circuit must be terminated into the bottom six terminals as indicated in the diagram below. Ensure that each signal and power channel has been paired and segregated correctly. For installation involving 120 VAC circuits only: Wire all output circuits using conductors suitable for Class 1 / Light and Power circuits rated 150 V minimum. The signal control circuit conductors can be intermingled with the branch circuit wiring in the wire trough. The signal control circuit conductors can be considered as Class 2 conductors. Class 2 wiring methods can be used for the signal control circuit outside the DMC control panel. For installation involving 240 or 277 VAC circuits: Wire all output circuits using conductors suitable for Class 1 / Light and Power circuits rated 300V min. The signal control circuit conductors can be intermingled with the branch circuit wiring in the wire trough. The signal control circuit conductors are to be considered as Class 1 conductors. Class 1 / Light and Power wiring methods must be used for the signal control circuit outside the DMC control panel. DMC2 10 Product Overview

1.4 DMP310-GL September 24, 2015 The DMP310-GL is a phase-cut dimming controller, software-selectable between leading edge and trailing edge, and is compatible with most dimmable drivers. 1.4.1 Dimensions / Diagrams DMC2 11 Product Overview

1.5 DMR31X September 24, 2015 The DMR31X module is a three-channel relay controller, capable of controlling most types of switched loads, including lighting and motor control. 1.5.1 Dimensions / Diagrams DMC2 12 Installation

September 24, 2015 2 Installation The DMC2 enclosure and modules are shipped separately and assembled onsite. This section describes the requirements and procedure for mounting and assembly. Installation Overview 1. Confirm that all installation requirements are met 2. Remove knockout plates for cabling 3. Mount enclosure 4. Install modules 5. Connect cabling 6. Energize and test unit 2.1 Important Information WARNING: Isolate from mains supply before terminating or adjusting any terminals. No serviceable parts inside. Service by qualified personnel only. We recommend that you read this entire document prior to commencement of installation. Do not energize the DMC until all the installation steps detailed in this chapter are complete. Installation of the home and building automation and control system shall comply with HD60364-4-41 where applicable. Once assembled, powered and terminated correctly, this device will operate in basic mode. A new Philips Dynalite user interface on the same network will turn all output lighting channels on from button 1 and off from button 4 allowing testing of network cables and terminations. Advanced functions and custom presets can then be configured via the EnvisionProject commissioning software. If commissioning services are required, contact your local distributor for details. This device should only be operated from the type of supply specified on installed modules. This device must be earthed. Do not Megger test any circuitry connected to the dimming system, as damage to the electronics may result. WARNING: The DMC must be de-energized before terminating the control and data cables. DMC2 13 Installation

2.2 Installation requirements September 24, 2015 The DMC2 is designed for indoor use only. If installed in an outdoor location, the DMC2 must be housed in a suitable well-ventilated enclosure. Choose a dry location that will be accessible after the installation is complete. To ensure sufficient cooling, you must mount the DMC2 vertically, as shown below. The DMC2 requires an air gap of at least 200mm (8 inches) on all sides of the front cover for adequate ventilation. This gap also ensures that the device is serviceable while still mounted. During operation the DMC2 may emit some audible noise such as humming or relay chatter. Take this into account when choosing the mounting location. DMC2 14 Installation

2.3 Cabling September 24, 2015 Remove the required knockout plates for the supply cables before mounting the enclosure. The DMC2 includes the following cabling knockouts. Cables should enter the enclosure through the nearest knockout to the relevant module. Supply/Control: Top: 4 x 28.2mm (1.1 ) 2 x 22.2mm (0.87 ) Side: 7 x 28.2 (1.1 ) 7 x 22.2mm (0.87 ) Back: 4 x 28.2mm (1.1 ) 3 x 22.2mm (0.87 ) Data: Side: 1 x 28.2mm (1.1 ) Bottom:1 x 28.2mm (1.1 ) The 28.2mm (1.1 ) knockouts are suitable for 3/4 conduit, while the 22.2mm (0.87 ) knockouts are suitable for 1/2 conduit. The recommended cable for connections to the serial port is screened stranded RS485 compatible CAT-5E data cable with three twisted pairs. Refer to the Installation Instructions for the communication module for more cabling information. This cable must be segregated from mains and Class 1 cables as per local electrical code. If anticipated cable runs are over 600 meters for serial cables, consult your dealer for advice. Do not cut or terminate live data cables. The DSM2-XX module input terminals accept supply cables up to 16mm 2. Supply cables should have a capacity of 32A per phase for three-phase supply or up to 63A for single phase to allow the device to be loaded to its maximum capacity. The Earth bar is located in DMC unit near the top of case. If mounting the unit to a cable tray or a Unistrut-style product, you can route cables between the unit and the mounting surface to enter the enclosure via the knockouts on the rear face. Control/communication cables enter at the bottom of the enclosure. Never run control cables through the mains voltage section of the enclosure. WARNING: Do not remove any labels or stickers from cables, wiring, modules or other components in the DMC. Doing so may violate local safety regulations. DMC2 15 Installation

2.4 Mounting the DMC2 The DMC2 can be surface or recess mounted. September 24, 2015 Surface mounting uses four mounting points, indicated below: Recess mounting is supported by four mounting holes suitable for M6 (1/4 ) fasteners, two on either side of the enclosure as shown below. The minimum spacing between studs is 380mm (15 ), and the minimum mounting depth is 103mm (4.1 ). Ensure no dust or other debris enters the device during installation. Do not leave the front cover off for any length of time. Excessive dust may interfere with cooling. DMC2 16 Installation

September 24, 2015 2.5 Inserting and connecting modules Control modules fit in either mounting bay, and you can install any two modules in the same unit. Control modules are connected to the supply module with the supplied wiring loom, and to the communication bus with the ribbon cable connectors on the left-hand side of the enclosure. Install modules: 1. Mount the enclosure using one of the methods described in 2.3 Mounting the DMC2. 2. Mount the communication module below the high-voltage barrier. Refer to the instructions in 2.4.1 DCM-DyNet. 3. Mount the power supply module in the top of the enclosure. Refer to the instructions in 2.4.2 DSM2-XX. 4. Mount the control modules in the remaining module spaces. Any module can be mounted in any location and a location can be left empty. Refer to the instructions in 2.4.3 Control module installation, and the Quick Installation Guide provided with each module. DMC2 17 Installation

September 24, 2015 5. Connect the supplied wiring loom to the modules. Use only the loom supplied with the unit, and do not modify the loom in any way. Refer to 2.4.4 Wiring loom. 6. Check and retighten all terminals. Remove the required knockouts from the top cover plate, then reattach the cover plate to the unit and make sure all screws are tightened securely. Stick the labels provided with modules on the cover to indicate what module is installed in each location. 7. Reattach the bottom cover plate and make sure all screws are tightened securely. DMC2 18 Installation

2.5.1 Communication Module - DCM-DyNet September 24, 2015 The DCM-DyNet module is mounted in the bottom section of the enclosure, below the high-voltage barrier. Remove the protective film from the keypad before installing this module. Insert the DCM-DyNet: 1. Adjust the jumper located next to the control ribbon cable connector to select the required DyNet voltage: 12V (factory default) or 24V. 2. Connect the control ribbon cable from the module to the DMC communication bus. 3. Align the mounting tab with the slot on the left and slide the module into position. 4. Secure the module using the fixing screw on the right. The unit should sit securely with no movement. The DCM-DyNet installation is now complete. DMC2 19 Installation

September 24, 2015 2.5.2 Supply Module - DSM2-XX The DSM2-XX module is mounted in the top section of the enclosure. Insert the DSM2-XX: 1. Connect the 24VDC Class 2/SELV supply plug to the two-way socket behind the DMC communication bus socket. Note that the internal power supply is derived from phase L1. For correct operation of the unit, ensure that supply on phase L1 is always present. 2. Locate the tab and slide the module into position as shown. 3. Secure the module using the fixing screw on the right. The unit should sit securely with no physical movement. DMC2 20 Installation

September 24, 2015 4. Terminate the supply wires into the right-hand side of the terminals and to the Earth bar on the right-hand side of the enclosure. 5. Terminate the supply group of the wiring loom into the left-hand side of the terminals. Refer to 2.4.4 Wiring loom for more information. 6. Recheck all terminal screws and tighten as needed. The DSM2-XX installation is now complete. Note: Phase one power (L1) must be supplied for the DMC to operate. All internal modules receive power from phase L1. If this phase is not supplied, the device will not turn on (even if L2 and L3 are still available). DMC2 21 Installation

2.5.3 Control module installation September 24, 2015 Control Modules can be mounted in any available module location within the DMC unit. Insert the control module: 1. Mount the circuit breakers. Use only the circuit breakers provided in the installation kit, oriented so that they are isolated when switched toward the output side as shown. 2. Connect the SELV / Class 2 control ribbon cable between the module and the DMC communication bus. 3. Locate the tab and slide the module into position. 4. Secure the module using the fixing screw on the right side. The unit should sit securely with no physical movement. DMC2 22 Installation

September 24, 2015 5. Terminate the control module s supply input wires into the right side of the circuit breakers. 6. Terminate the corresponding Module group of the wiring loom into the left side of the circuit breakers. 7. Recheck all terminal screws and tighten. The control module installation is now complete. The lighting/load groups can be terminated into the module s output terminals. Note: Refer to 1.3.2 DMD31X module output wiring for further information before terminating DMD31X module loads. DMC2 23 Installation

September 24, 2015 2.5.4 Wiring loom The DMC wiring loom is designed to ensure correct wiring from the power supply module to the control modules. The terminations for each module are held in the required order with clearly labelled plastic brackets. Make sure the labels on each bracket correspond to the wiring on each module, as shown here. For modules requiring termination, remove the black insulating caps from the wires before terminating to the load and supply modules. Warning: Use only the wiring loom supplied with the unit, and do not break or modify the loom in any way. Take care to ensure that no wires are caught under the cover when closing the device. The black insulating caps on the harness are only to be removed when wired to a module. If any are not used, ensure they are securely attached and the connector underneath is not exposed. If the black caps are not available, the unterminated wires must be protected with a mains-rated isolating electrical terminator before the DMC is energized. DMC2 24 Post-installation testing

September 24, 2015 3 Post-installation testing If you need to energize the load circuits on the DMC before connecting it to the rest of the network, you can replace the cover and energize the device immediately. The default factory programming sets all channels to 100% output. For more information on testing and troubleshooting procedures, visit https://dynalite.org/ 3.1 Service LEDs and switch The DMC has a green and a red service LED. Only one LED is lit at a time: Green: DyNet Watchdog activated and network heartbeat signal detected Red: DyNet Watchdog deactivated or timed out (indicates possible network fault) The heartbeat signal is transmitted periodically over DyNet by other network devices such as gateways, allowing the DMC to easily tell if it is still connected to the rest of the network. For more information on configuring the DMC s Watchdog settings, refer to the DMC2 Commissioning Guide. The active service LED shows one of three patterns: Blinking slowly: Normal operation Blinking quickly: Normal operation, network activity detected Permanently ON: Fault The service switch activates the following functions: One press: Transmit network ID Two presses: Set all channels to On (100%) Press and hold for four seconds, then release: Reset the device DMC2 25 Post-installation testing

3.2 Manual override keypad September 24, 2015 WARNING: Manual overrides do not provide permanent isolation. Isolate at the supply before performing work on load circuits. Once the DMC2 has been fully installed and energized, you can remove the bottom cover plate and use the keypad on the DCM-DyNet module to test each module and channel in the device. Press the Module Select button to select the module for testing. If a module is not detected, the indicator will automatically skip to the next module. The CHANNEL light for each channel shows whether the channel is Off/unused (0%) or On (1-100%). Faulty channels are indicated by a flashing light. Press the channel number button to toggle the channel between Off (0%) and On (100%). The keypad times out after 30 seconds. At this point the keypad switches off but all channels remain at their current level. DMC2 26 Post-installation testing