General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

Similar documents
General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

CPU 1214C. Overview. Design. The compact CPU 1214C has:

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

Supply voltage. Input current. Encoder supply. Memory

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

General information. Supply voltage

Product type designation. General information. Supply voltage. Input current

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

Product type designation. General information. Supply voltage

SIPLUS CPU 313C-2DP. Function

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

Product type designation

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Display. Control elements. Supply voltage

General information. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage

Central processing units CPU 221, CPU 222, CPU 224, CPU 224 XP, CPU 224 XPsi, CPU 226

CPU 224. The compact high-performance CPU With 24 inputs/outputs on board Expandable with up to 7 expansion modules Design

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

o SIPLUS LOGO! MODULAR BASIC VARIANTS

Product type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

General information. Supply voltage. Input current

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

Programming package STEP 7 V5.2 SP1 or higher with HSP 0126

100 ms. 30 µs; Time per I/O byte. 24 V DC No; Power supply via system power supply. Not relevant for 400 series (300 series set)

General information. Supply voltage. Input current

SIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.

Siemens AG SIMATIC S Micro Controller for Totally Integrated Automation. Catalog ST 70 N April 2009 SIMATIC. Answers for industry.

Product type designation. General information. Supply voltage. Input current. Power loss

Data sheet CC 03, Commander Compact (603-1CC21)

Overview. Application. Function. Technical specifications. Home

Data sheet VIPA CPU 115DP (115-6BL22)

SIMATIC S /2 Introduction

TM221M16R controller M IO relay

Product type designation. General information. Supply voltage

Product type designation. General information. Supply voltage. Input current. Power losses

Product type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory

SIMATIC S /2 3/4 3/22 SIPLUS 3/26 3/33 SIPLUS

Data sheet CPU 013C (013-CCF0R00)

Data sheet CPU 115 (115-6BL02)

Supply voltage. Input current. Power loss. Memory. Battery. CPU processing times

CPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS

TM221CE24R controller M IO relay Ethernet

TM221CE40T controller M IO transistor PNP Ethernet

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

CM597 Ethernet Communication Module

TM221ME32TK controller M IO transistor PNP Ethernet

TM221M16TG controller M IO transistor PNP spring

Product type designation. Display. Control elements

TM221M32TK controller M IO transistor PNP

FEATURES DESCRIPTION FEATURES

AI561 Analog Input Module

TM221CE40R controller M IO relay Ethernet

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

CPU 412H. Function. Parameterizable properties

DI572 Digital Input Module

Data sheet VIPA CPU M13C (M13-CCF0000)

DC562, digital input/output module,

DC561, digital input/output module,

TM200CE24T controller M IO transistor Source+ Ethernet

SIPLUS S7-200 PS 203. Overview

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

TM221ME16T controller M IO transistor PNP Ethernet

AO561 Analog Output Module

Data sheet VIPA CPU 214PG (214-2BE03)

DX561 Digital Input/Output Module

Transcription:

Data sheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40...+70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG40-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC 10 DO 24 V DC 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Product type designation Engineering with Programming package Display with display Supply voltage Rated value (DC) 24 V DC permissible range, lower limit (DC) permissible range, upper limit (DC) Load voltage L+ Rated value (DC) permissible range, lower limit (DC) permissible range, upper limit (DC) Input current Current consumption (rated value) Current consumption, max. Inrush current, max. Encoder supply 24 V encoder supply 24 V Output current for backplane bus (5 V DC), max. Power loss Power loss, typ. Memory Type of memory Work memory integrated CPU 1214C DC/DC/DC STEP 7 V13 SP1 or higher No 20.4 V 28.8 V 24 V 20.4 V 28.8 V 500 ma; CPU only 1 500 ma; CPU with all expansion modules 12 A; at 28.8 V DC L+ minus 4 V DC min. 1 600 ma; Max. 5 V DC for SM and CM 12 W RAM 100 kbyte Page 1/8 21.01.2016 Copyright Siemens AG

expandable Load memory integrated Plug-in (SIMATIC Memory Card), max. Backup present without battery CPU processing times for bit operations, typ. for word operations, typ. for floating point arithmetic, typ. CPU-blocks Number of blocks (total) OB Number, max. Data areas and their retentivity retentive data area in total (incl. times, counters, flags), max. Flag Number, max. Address area Process image Inputs, adjustable Outputs, adjustable Hardware configuration Number of modules per system, max. No 4 Mbyte 2 Gbyte; with SIMATIC memory card ; maintenance-free 0.085 µs; / instruction 1.7 µs; / instruction 2.3 µs; / instruction DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used Limited only by RAM for code 10 kbyte 8 kbyte; Size of bit memory address area 1 kbyte 1 kbyte 3 communication modules, no signal board can be used, 8 signal modules Time of day Clock Hardware clock (real-time clock) Backup time 480 h; Typical Deviation per day, max. 60 s/month at 25 C Digital inputs Number of digital inputs 14; Integrated of which inputs usable for technological 6; HSC (High Speed Counting) functions integrated channels (DI) 14 m/p-reading Page 2/8 21.01.2016 Copyright Siemens AG

Number of simultaneously controllable inputs all mounting positions Input voltage up to 40 C, max. 14 Rated value (DC) for signal "0" for signal "1" Input delay (for rated value of input voltage) for standard inputs 24 V 5 V DC at 1 ma 15 VDC at 2.5 ma parameterizable 0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four at "0" to "1", min. 0.2 ms at "0" to "1", max. 12.8 ms for interrupt inputs parameterizable for counter/technological functions Cable length parameterizable Single phase: 3 @ 100 khz & 3 @ 30 khz, differential: 3 @ 80 khz & 3 @ 30 khz shielded, max. unshielded, max. Digital outputs Number of digital outputs 10 of which high-speed outputs integrated channels (DO) 10 Short-circuit protection Limitation of inductive shutdown voltage to L+ (-48 V) Switching capacity of the outputs with resistive load, max. on lamp load, max. Output voltage for signal "0", max. for signal "1", min. Output current for signal "1" rated value for signal "0" residual current, max. Output delay with resistive load 500 m; 50 m for technological functions 300 m; For technological functions: No 4; 100 khz Pulse Train Output No; to be provided externally 0.5 A 5 W 0.1 V; with 10 kohm load 20 V 0.5 A 0.1 ma "0" to "1", max. 1 µs "1" to "0", max. 3 µs Switching frequency of the pulse outputs, with resistive load, max. Cable length 100 khz Page 3/8 21.01.2016 Copyright Siemens AG

shielded, max. unshielded, max. 500 m 150 m Analog inputs Number of analog inputs 2 integrated channels (AI) 2; 0 to 10V Input ranges Voltage Input ranges (rated values), voltages 0 to +10 V Input resistance (0 to 10 V) 100k ohms Cable length shielded, max. 100 m; twisted and shielded Analog outputs Number of analog outputs 0 Analog value generation Integration and conversion time/resolution per channel Resolution with overrange (bit including sign), 10 bit max. Integration time, parameterizable Conversion time (per channel) 625 µs Encoder Connectable encoders 2-wire sensor 1. Interface Interface type PROFINET Physics Ethernet Isolated automatic detection of transmission rate Autonegotiation Autocrossing Functionality PROFINET IO Controller PROFINET IO Device ; Also simultaneously with IO-Device functionality PROFINET IO Controller Transmission rate, max. 100 Mbit/s Services Number of connectable IO Devices, max. 16 PROFINET IO Device Services Shared device Page 4/8 21.01.2016 Copyright Siemens AG

Number of IO Controllers with shared device, max. Protocols Supports protocol for PROFINET IO PROFIBUS AS-Interface Protocols (Ethernet) TCP/IP Further protocols MODBUS Communication functions S7 communication supported as server as client Open IE communication TCP/IP ISO-on-TCP (RFC1006) UDP Web server supported User-defined websites Number of connections overall Test commissioning functions Status/control Status/control variable Variables Forcing Forcing Diagnostic buffer present Traces Number of configurable Traces 2 ; CM 1243-5 required 16; dynamically Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters 2; Up to 512 KB of data per trace are possible Integrated Functions Number of counters 6 Counting frequency (counter) max. 100 khz Frequency meter controlled positioning Number of position-controlled positioning axes, max. 8 Page 5/8 21.01.2016 Copyright Siemens AG

Number of positioning axes via pulse-direction 4; With integrated DO interface PID controller Number of alarm inputs 4 Number of pulse outputs 4 Limit frequency (pulse) 100 khz Potential separation Potential separation digital inputs Potential separation digital inputs 500V AC for 1 minute between the channels, in groups of 1 Potential separation digital outputs Potential separation digital outputs between the channels No between the channels, in groups of 1 EMC Interference immunity against discharge of static electricity Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 Test voltage at air discharge 8 kv Test voltage at contact discharge 6 kv Interference immunity to cable-borne interference Interference immunity on supply lines acc. to IEC 61000-4-4 Interference immunity on signal cables acc. to IEC 61000-4-4 Interference immunity against voltage surge on the supply lines acc. to IEC 61000-4-5 Interference immunity against conducted variable disturbance induced by high-frequency fields Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 Emission of radio interference acc. to EN 55 011 Limit class A, for use in industrial areas ; Group 1 Limit class B, for use in residential areas ; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 Degree and class of protection Degree of protection acc. to EN 60529 IP20 Standards, approvals, certificates CE mark Ambient conditions Free fall Page 6/8 21.01.2016 Copyright Siemens AG

Drop height, max. (in packaging) 0.3 m; five times, in dispatch package Ambient temperature during operation min. -40 C; = Tmin; Startup @ -25 C max. 70 C; = Tmax; Tmax > +55 C number of simultaneously switched-on digital inputs 7, digital outputs 5, analog inputs 2 (no adjacent points) with horizontal mounting position; Tmax > +60 C number of simultaneously switched-on digital inputs 7, digital outputs 5, analog inputs 1 (no adjacent points) with horizontal mounting position Ambient temperature during storage/transportation min. -40 C max. 70 C Vibrations Vibrations 2G wall mounting, 1G DIN rail Operation, tested according to IEC 60068-2-6 Shock test tested according to IEC 60068-2-27 ; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms Extended ambient conditions relative to ambient temperature-atmospheric Tmin... Tmax at 1080 hpa... 795 hpa (-1000 m... +2000 m) // pressure-installation altitude Tmin... (Tmax - 10K) at 795 hpa... 658 hpa (+2000 m... +3500 m) // Tmin... (Tmax - 20K) at 658 hpa... 540 hpa (+3500 m... +5000 m) Relative humidity With condensation, tested in accordance 100 %; RH incl. condensation/frost (no commissioning under with IEC 60068-2-38, max. condensation conditions) Resistance against biologically active substances / ; Class 3B2 mold, fungus and dry rot spores (with the conformity with EN 60721-3-3 exception of fauna). The supplied connector covers must remain on the unused interfaces during operation! against chemically active substances / ; Class 3C4 (RH < 75%) incl. salt spray according to EN conformity with EN 60721-3-3 60068-2-52 (degree of severity 3). The supplied connector covers must remain on the unused interfaces during operation! against mechanically active substances / ; Class 3S4 incl. sand, dust. The supplied connector covers conformity with EN 60721-3-3 must remain on the unused interfaces during operation! Configuration Programming Programming language LAD FBD SCL Cycle time monitoring adjustable Dimensions Page 7/8 21.01.2016 Copyright Siemens AG

Width Height Depth Weights Weight, approx. 110 mm 100 mm 75 mm 415 g last modified: 19.01.2016 Page 8/8 21.01.2016 Copyright Siemens AG